Survival Tips For Tube Equipment:
To prolong tube life, observe these simple recommendations:
After using the equipment, allow sufficient time for it to properly cool down prior to
moving it. A properly cooled gear prolongs tube life due to the internal components
being less susceptible to the damage caused by vibration.
Allow the tube to warm up to room temperature before turning it on. The heat
generated by the tube elements can crack a cold glass housing.
Protect the gear from dust and moisture. If liquid gets into, or if the gear is dropped or
otherwise mechanically abused, it must be checked out in an authorized service
center before using it.
Proper maintenance and cleaning in combination with routine checkups by your
authorized service center or dealer, will ensure the best performance and longest life
for your tube audio gear.
EQ1ch Tube Equalizer MCAudioLab6
Power
Use this switch to turn the unit on and off.
Controls primary AC power to the unit. The primary power is applied to the EQ1ch circuits
when the Power switch is in the up position. The power toggle switch connect or disconnect
the phase wire of mainAC power supply (IEC connector on the rear). When off, the apparatus
is not completely disconnected from AC power source. Detach IEC power cord if EQ is
unutilized for a long period.
GROUND LIFT
When it is activated unlinks pin 1 from signal ground (GND) to avoid hum. Ground lift acts on
XLR out connector only.
EARTH LIFT
This switch will lift the main earth connection of the chassis from signal ground (GND) so you
can avoid hum noise. Chassis is permanently earth connected via centarl pin of IEC socket.
The earth is always connected with a standard plug on the rear of each unit.
AC Plug
TP1ch uses a standard, detachable IEC power cord. Insert the AC power cord firmly into this
socket.
caution: please check to see what voltage your EQ1ch is set to. The voltage setting is marked
on the serial badge on the rear panel. Make sure the voltage is properly set for your area
before applying AC power to the unit. Check that this complies with your local supply; if not,
please notify MCAudioLab before powering up. Your EQ1ch has been factory set to the
correct mains voltage for your country. If you plan to take the unit to countries with a different
mains voltage you will need to send the EQ1ch to the MCAudioLab Service Center for the
correct transformer primaries wiring conversion and fuse changing.
Do not attempt to defeat the safety ground connection!
Fuse
This unit employs an external AC line fuse (easy access to change your fuse, as necessary )
to help protect it from damages due to overload conditions. If the fuse fails, replace it. If the
fuse fails repeatedly, discontinue use of the unit and contact MCAudioLab for service
information.
Remove the power cord before checking or changing the fuse.
To avoid any permanent damage replace fuse with the same rate and type only:
a 2A(5 x 20mm type) fuse is required for operation at 230V;
a 4A(5 x 20mm type) fuse is required for operation at 115V.
CAUTION: Tube replacement should be performed only by qualified service personnel who are
familiar with the dangers of hazardous voltages that are present in tube circuitry.