In t
h
If t
h
fir
e
pe
r
Do
va
p
ot
h
W
H
Do
Im
m
ap
p
an
y
F
h
e Commonw
e
Installation
m
gas fitter;
A CO detect
o
appliance is i
h
e informatio
n
e
or explosion
r
sonal injury
o
not store o
r
p
ors and liq
u
h
er applianc
e
H
AT TO DO IF
Open windo
w
Do not touc
h
Do not try t
o
Extinguish
a
Do not use t
Immediately
phone. Foll
o
If you cann
o
department.
NOT use this
m
ediately call
a
p
liance and to
y
gas control,
w
F
ULLVIE
W
e
alth of Massa
c
m
ust be perfor
m
o
r shall be inst
a
nstalled.
WAR
N
n
in this man
u
may result c
a
o
r loss of life.
r
use gasoli
n
u
ids in the v
i
e
.
YOU SMELL
G
w
s.
h
electrical s
w
o
light any ap
p
a
ny open flam
e
he phone in
y
call your gas
o
w the gas su
o
t reach your
g
WAR
N
appliance if a
n
a
qualified ser
v
replace any p
w
hich has bee
n
W
DIREC
T
HO
D
c
husetts:
m
ed by a licens
e
a
lled in the roo
m
N
ING
u
al is not follo
w
a
using prope
r
n
e or other fl
i
cinity of thi
s
G
AS
w
itches.
p
liance.
e
.
y
our building.
supplier fro
m
pplier’s instr
u
g
as supplier,
c
N
ING
n
y part has be
e
v
ice technicia
n
art of the con
t
n
under water.
T
VENT
G
Mo
d
ME OW
N
D
OCUMENT
e
d plumber or
m
where the
w
ed exactly,
a
r
ty damage,
ammable
s
or any
m
a neighbor'
s
u
ctions.
c
all the fire
e
n under wate
r
n
to inspect th
e
t
rol system an
d
G
AS FIRE
d
el FV-3
3
N
ER’S
M
NO. F
V
33i-
O
WA
R
tion,
erty
addi
vice
TH
E
TH
E
a
s
A q
u
er
m
Do
n
por
s
plia
n
Do
n
cra
c
sho
u
Me
n
Do
n
pla
c
hea
t
ma
r
r
.
e
d
The
the
a
Fue
l
Gas
PLACE I
N
3
i
M
ANUA
L
O
M-1110
R
NING: Impr
o
service or m
a
damage. Ref
e
tional informa
t
agency or the
E
SE INSTRU
C
E
HOMEOWN
E
F
O
u
alified installe
r
m
ust perform in
n
ot store or us
e
s
and liquids in
n
ce.
n
ot operate thi
s
c
ked or broken
u
ld do replace
m
n
dota gas firepl
n
ot burn wood,
c
e. This firepla
t
source. It is
a
r
y heat supply.
installation m
u
a
bsence of lo
c
l
Gas Code,
A
and Propane
N
SERT H
L
o
per installati
o
a
intenance ca
n
e
r to this man
u
t
ion consult a
q
gas supplier.
CAUTION
C
TIONS ARE
E
R.
O
R YOUR SA
F
r
, service age
n
stallation and
s
e
gasoline or o
t
the vicinity of
t
WARNIN
G
s
appliance wit
. A licensed o
r
m
ent of glass.
WARNIN
G
aces are heat
paper or othe
ce is designed
a
dvisable to ha
v
u
st conform
w
c
al codes, wit
h
A
NSI Z223.1,
o
Installation Co
d
EATER
o
n, adjustment
,
n
cause injury
o
u
al. For assis
t
q
ualified instal
TO REMAIN
F
ETY
n
cy, or the gas
s
ervice.
t
her flammabl
e
t
his or any oth
e
G
h the glass re
m
r
qualified per
s
G
producing app
r materials in t
h
as a supplem
e
v
e an alternati
v
w
ith local code
s
h
the current
N
o
r the current
N
d
e, CSA B149
.
,
altera-
o
r prop-
t
ance or
ler, ser-
WITH
suppli-
e
va-
e
r ap-
m
oved,
s
on
liances.
h
is fire-
e
nt
v
e pri-
s
or, in
N
ational
N
atural
.
1

2 | Page
85-03-00811
TableofContents
SAFETY AND WARNING INFORMATION ..........................................................................................3
SPECIFICATIONS................................................................................................................................4
CONGRATULATIONS .........................................................................................................................5
BUILDING PERMIT AND INSTALLATION INSPECTION APPROVAL REQUIREMENTS.................5
BEFORE YOU BEGIN..........................................................................................................................6
REMOTE CONTROL TRANSMITTER FUNCTIONS.............................................................................................................6
REMOTE TRANSMITTER OPERATING INSTRUCTIONS..................................................................7
TO TURN ON THE APPLIANCE:............................................................................................................................................7
TO TURN OFF THE APPLIANCE, PRESS THE ON/OFF BUTTON..................................................................................7
MODE KEY................................................................................................................................................................................7
FLAME HEIGHT........................................................................................................................................................................7
FAN SPEED CONTROL............................................................................................................................................................7
AUX (ACCENT-LIGHT)............................................................................................................................................................7
SECONDARY BURNER...........................................................................................................................................................7
MANUAL BYPASS OF THE REMOTE SYSTEM.................................................................................8
TEMPERATURE INDICATOR (OF OR OC)...........................................................................................8
KEY LOCK FUNCTION........................................................................................................................8
LOW BATTERY POWER DETECTION ...............................................................................................8
OPERATING DURING POWER OUTAGES ........................................................................................8
“FIRST TIME” PILOT LIGHTING INSTRUCTIONS.............................................................................9
INITIALIZING THE REMOTE CONTROL SYSTEM...........................................................................................................10
SYNCHRONIZING RECEIVER AND TRANSMITTER........................................................................................................10
IPI/STANDING PILOT SYSTEM INFORMATION ..............................................................................10
IPI MODE. ................................................................................................................................................................................10
STANDING PILOT MODE......................................................................................................................................................10
FV33I DOOR REMOVAL AND INSTALLATION..................................................................................9
BLOWER SYSTEM INFORMATION..................................................................................................12
BLOWER OPERATION...........................................................................................................................................................12
MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM................................13
MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY..............................15

3 | Page
85-03-00811
SAFETY AND WARNING INFORMATION
READ and UNDERSTAND all instructions carefully before starting the appliance. FAILURE TO FOLLOW these instruc-
tions may result in a possible fire hazard and will void the warranty.
Any safety screen or guard removed for servicing must be replaced before operating this appliance.
DO NOT USE this appliance if any part has been under water. Immediately CALL a qualified service technician to inspect
the appliance and to replace any part of the control system and any gas control, which has been underwater.
THIS UNIT IS NOT FOR USE WITH SOLID FUEL.
Installation and repair should be PERFORMED by a qualified service person. The appliance and venting system should
be INSPECTED before initial use and at least annually by a professional service person. More frequent cleaning may be
required due to excessive lint from carpeting, bedding, material, etc. It is IMPERATIVE that the unit’s control compart-
ment, burners, and circulating air passageways ARE KEPT CLEAN to provide for adequate combustion and ventilation
air.
Always KEEP the appliance clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
NEVER OBSTRUCT the flow of combustion and ventilation air. Keep the front of the appliance CLEAR of all obstacles
and materials for servicing and proper operation.
Due to high temperature, the appliance should be LOCATED out of traffic areas and away from furniture and draperies.
Clothing or flammable material SHOULD NOT BE PLACED on or near the appliance.
Children and adults should be ALERTED to the hazards of high surface temperature and should STAY AWAY to avoid
burns or clothing ignition. Young children should be CAREFULLY SUPERVISED when they are in the same room as the
appliance.
These units MUST use one of the vent systems described in the Installing Your Fireplace section of the Installers Guide.
NO OTHER vent systems or components MAY BE USED.
This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chim-
ney serving a separate solid fuel-burning appliance. Each gas appliance MUST USE a separate vent system. Common
vent systems are PROHIBITED.
If the vent-air intake system is disassembled for any reason, reinstall per the instructions provided for the initial installa-
tion.
The vent system assembly for this fireplace must be periodically examined by a qualified service agency.
INSPECT the external vent cap on regular basis to make sure that no debris is interfering with the airflow. The flow of
combustion and ventilation air not to be obstructed
DO NOT abuse the glass door by striking the glass, slamming the door shut, etc.
Use only authorized parts and materials obtained from Johnson Gas Appliance Company when replacing defective or
damaged glass.
DO NOT USE abrasive cleaners on the glass door assembly. DO NOT ATTEMPT to clean the glass door when it is hot.
Turn off the gas before servicing this appliance. It is recommended that a qualified service technician perform an ap-
pliance check-up at the beginning of each heating season.
DO NOT place furniture or any other combustible household objects within 36 inches of the fireplace front.

85-0
3
Inpu
t
Mini
m
Orifi
c
Mani
Mani
Mini
m
A
ir s
h
EFFI
C
FLU
E
......
.
NET
SAF
E
GAS
ELE
C
LIST
Gas
a
tion
a
and
c
INSE
R
GLAS
S
NOT
IN T
H
APP
L
INTE
Certi
f
room
T
H
R
E
T
h
af
t
m
a
m
o
b
y
T
h
th
e
ra
t
HI
c
o
3
-00811
t
rating (Btu/
h
m
um input (B
t
c
e size (DMS
fold pressur
e
fold pressur
e
m
um inlet pr
e
h
utter setting
s
C
IENCIES ....
.
E
VENT LINE
R
.
..................
.
WEIGHT......
.
E
T
Y
..............
.
REQUIREME
N
C
TRICAL REQ
U
INGS - INTE
a
ppliances m
u
a
l Standards I
c
ertified by I
n
R
T INCLUDES CE
S
,THERMOSTATI
E: LPG CON
H
IS FIREPL
A
L
IANCE CER
T
RTEK TESTIN
f
ied under AN
S
installations a
n
C
H
ESE INST
R
E
MAIN WITH
T
h
is appliance
t
ermarket, p
e
a
nufactured
h
o
bile home,
w
y
local codes.
h
is appliance
e
type(s) of g
t
ing plate.
GH ALTITU
D
o
ntact the Me
n
SPECI
F
h
r) 0-610 m
t
u/hr) 0-610
m
) 0-610 m (f
r
e
(in. w.c./kP
a
e
(in. w.c./kP
a
e
ssure (in. w.
c
s
(in)
.
..................
R
..................
.
..................
.
..................
.
..................
N
TS.............
U
IREMENTS
RTEK TESTI
N
u
st be tested
nstitute - AN
S
n
tertek Testi
n
RAMIC COMBU
S
C REMOTE ELE
C
VERSION KI
A
CE INSERT.
T
IFICATION A
N
G SERVICES
,
S
I Z21.88 (200
5
n
d mobile ho
m
AUTION
R
UCTIONS
A
T
HE HOMEO
W
may be insta
e
rmanently lo
c
h
ome (USA o
w
here not pro
is only for us
e
as indicated
o
D
E INSTALL
A
n
dota techni
c
F
ICATIO
N
m
r
ont/rear)
a
) > High Fire
a
) >Low Fire
c
./kPa)
........ .EXCE
E
........ .CO-LI
N
........ Minim
u
........ .165 lb
s
........ .AGA C
ACTI
VA
........ .SUPP
L
N
A
L.
P
...... 12
0
N
G SERVICE
S
and certified
S
I Gas Applia
ng
Services. 8
S
TION SYSTEM,
C
TRONIC IGNITI
O
T, # HA-82-0
N
D TESTING
A
,
ICBO#AA647
5
) CSA 2-33
m
es. UL307B
a
A
RE TO
W
NER.
lled in an
c
ated,
nly) or
hibited
e
with
o
n the
A
TION INFO
R
c
al service de
N
S MOD
E
Na
3
1
3
1
5
E
DS D.O.E. E
F
N
EAR - 4” DI
A
u
m Vent Len
g
s
.
ERTIFIED, E
L
VA
TED WITH
T
L
Y PRESSURE
A
T. GAS:
P
. GAS:
0
Volts AC, 2
S
TESTED TO:
by a nationa
nce Safety S
t
431 Murphy
D
DUAL HOT AIR
B
O
N, AGA CERTI
F
0411, MUST
A
GENCY
-4
(2005) “Vente
d
a
pproved for "
m
NOT
E
of loc
a
A
NSI
Prop
a
da.
WAR
N
crack
e
place
m
R
MATION:
P
partment for
s
E
L FV-33i
tural Gas
P
3
1,000
1
0,000
49/45
3
.5/0.87
.7/0.42
5
.0/1.24
1/16”
F
FICIENCY R
E
A
METER EXH
A
g
th is 10 feet
L
ECTRONIC I
G
T
HERMOSTA
T
: GAS INL
E
7" W.C.
11" W.C.
Amps
A
NSI Z21.8
8
lly reco
g
nize
d
t
andards. .
T
D
rive, Middle
t
B
LOWERS, PRE
M
F
IED SAFETY SY
S
BE PURCH
A
d
Gas Fireplac
e
m
obile homes,
a
E
:This installa
t
a
l codes, you
m
Z223.1-latest
a
ne Installation
N
ING: Do not
e
d or broken.
m
ent of glass.
P
rior to installi
s
pecific venti
P
ropane Gas
31,000
13,000
3
/
64
”/
3
/
64
”
10.0/2.49
6.3/1.57
11.0/2.74
¼”
E
QUIREMEN
T
A
UST & 3” D
I
. Maximum V
e
G
NITION IPI
T
IC REMOTE
E
T: 3/8" N.P
.
[5.0" W.
C
[11" W.C
8
-2005 – CS
A
d
testin
g
and
T
he Mendota
t
on, WI 5356
M
IUM 8-PIECE FI
B
S
TEM.
A
SED SEPA
R
e
Heaters" not
a
fter first sale
o
t
ion must conf
o
m
ust comply w
edition in the
Code, CSA B
operate this
a
A licensed
o
ng at altitude
s
ng requirem
e
T
S (A.F.U.E.)
I
AMETER IN
L
e
nt Len
g
th is
SYSTEM
CONTROL.
.
T.
C
. MIN., 11"
W
. MIN., 13"
W
A
2.33-2005
–
certification
a
Gas Fireplac
e
2.
B
ER LOG SET &
R
ATELY TO
C
for use with s
o
o
f home, not f
o
o
rm to local co
d
ith the Nation
a
U.S.A. and th
e
149 Installati
o
a
ppliance with
o
r qualified p
e
s
higher than
e
nts and vent
i
L
ET
70 feet.
W
.C. MAX.]
W
.C. MAX.]
–
CAN/CGA 2.
ag
ency to A
m
e
Insert has
b
COALS, NEO-CE
R
C
ONVERT T
O
o
lid fuel. Appr
o
o
r recreational
v
d
es. In the ab
s
a
l Fuel Gas C
o
e
Natural Gas
a
o
n Codes in C
a
the glass rem
e
rson should
d
7500 feet, p
l
i
ng restrictio
n
4 | Pag
e
17-M91
m
erican Na-
b
een tested
R
AM
O
BURN LP
G
o
ved for bed-
v
ehicles."
s
ence
o
de,
a
nd
a
na-
oved,
d
o re-
l
ease
n
s.
e
G

5 | Page
85-03-00811
CONGRATULATIONS
You are the owner of a world-class heat producing gas direct vent sealed combustion fireplace insert.
This elegant, highly efficient Fireplace will be a constant source of comfort and fascination. It will be the focal point of
beauty and interest in your home.
The Mendota Gas Fireplace insert is a true heating appliance incorporating the traditional aesthetics of fireplace fire view-
ing with the controllability and fuel efficiency of a home gas furnace. Of particular interest is the low fuel consumption and
brilliant fire viewing afforded by the realistic Premium Fiber wood fire-like combustion system.
Carefully read the following instructions prior to actual installation. Proper Mendota Gas Fireplace insert installation and
operation will give you years of safe, trouble free comfort and enjoyment.
If you have any questions regarding installation or operation of your Mendota Fireplace insert please contact your local
dealer.
...CAUTION...
Due to high temperatures, the Fireplace insert should be located away from furniture and draperies. Children and adults
should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the Mendota Gas Fireplace insert.
Clothing or other flammable material should not be placed on or near the Fireplace insert.
Any safety screen or guard removed for servicing an appliance must be replaced prior to operating this appliance.
This Mendota Gas Fireplace Insert is a powerful and efficient heating unit. It has been designed as a major source of
supplemental heat. As with any mechanical appliance there can be component shut downs. It is advisable to have an
alternate heat supply.
Installation, repair and any adjustments to logs or burner must be done by a qualified service person. The appliance
should be inspected before use and at least annually by a professional service person. More frequent cleaning may be
required due to excessive lint from carpeting, bedding material, carbon build-up, etc. It is imperative that control com-
partments, burners and circulating air passageways of the appliance be kept clean. The burner and pilot flames and logs
should be visually checked periodically.
DO NOT use this appliance if any part has been under water or exposed to moisture corrosion. Immediately call a quali-
fied service technician to inspect the Fireplace and replace any part of the control system and any gas control, which has
been under water. DO NOT use this fireplace if the burner does not light immediately. Turn unit off and call Mendota ap-
proved service person if there is any delay in burner light off.
It is Johnson Gas Appliance Company's policy that no responsibility is assumed by the Company or by any of its em-
ployees or representatives for any damages caused by an inoperable, inadequate, or unsafe condition which is the result,
either directly or indirectly, of any improper operation, installation or servicing procedures.
Building Permit and Installation Inspection Approval Requirements
All installations of Mendota Fireplaces and Inserts must comply with all the requirements stated in this Installation and
Operating Instructions Manual. The Dealer and/or installer must also obtain all required Building Permits and Inspection
Approval from the local building inspection department or the local body having jurisdiction. In order to validate warranty
coverage, Mendota may require facsimile copies of the Building Permit and Inspection Approval forms. Failure to provide
adequate proof that the installation conforms to all local requirements and the requirements stated in the Installation and
Operating Instructions Manual will void all applicable warranty.
INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH HOMEOWNER.
HIGH ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes higher than 7500, please con-
tact the Mendota technical service department for specific venting requirements and venting restrictions.

85-0
3
BE
F
Read
the i
n
Re
m
NO
T
Rem
com
m
Iden
t
Tran
s
1
2
3
4
3
-00811
F
ORE Y
O
this entire m
a
n
structions ma
y
m
ote Con
t
T
E: The Rec
e
ote Transmit
t
m
and has be
e
t
ify the four f
u
s
mitter:
1
. ON/OFF
K
turns the
s
When thi
s
and the s
y
lot light w
Switch” i
s
2
. THERM
O
tem is O
N
Thermost
a. Man
u
The r
o
heigh
able.
b. Nor
m
will s
t
creas
incre
a
butto
n
the S
E
will tu
turn
o
this
m
the fi
r
juste
d
can b
The
A
after
s
c. Sma
r
tions
mod
e
set p
o
temp
e
3
.UP/DOW
N
Fan Speed
4
.MODE S
E
Height, Fa
n
O
U BEGI
N
a
nual before y
o
y
result in pro
p
t
rol Trans
e
iver will “bee
p
t
er Key is pre
e
n received.
u
nction butto
n
K
EY: This bu
s
ystem ON o
s
button is pr
e
y
stem is OF
F
ill stay ON if
t
s
in the ON p
o
O
STAT KEY:
T
N
, will allow t
h
at.
u
al Mode: In
t
o
om temper
a
t control, sec
m
al Thermos
t
t
ay functionin
g
es 1
o
F abov
e
a
se the Set P
n
until the de
s
E
T POINT T
E
rn on 5 minu
t
o
ff 12-1/2 min
m
ode. The fla
m
r
eplace is fun
d
after 5 min
u
e turned On
o
A
ccent Light
c
s
tartup.
r
t Thermost
a
except the fl
a
e
. The Smart
o
int temperat
u
e
rature, the
S
N
KEY: This
k
and to toggle
b
E
LECTION
K
n
Speed, Acc
e
N
o
u use your ne
w
p
erty damage,
b
mitter Fu
p
” once ever
y
ssed, signali
n
n
s on the Re
m
tton
r OFF.
e
ssed
F
, the pi-
t
he “Standing
o
sition.
T
his button,
w
h
e selection o
t
his mode, th
e
a
ture rise has
ondary burn
e
t
at: In this m
o
g
until the ro
o
e
the Set Poi
n
oint Temper
a
s
ired temper
a
E
MPERATU
R
t
es after firep
utes after th
e
m
e height ca
n
ctioning, fan
s
u
tes of startu
p
o
r Off at any
t
c
an be turned
a
t: In this mo
d
a
me height a
d
Thermostat
f
u
re and the a
S
mart Functio
k
ey is used to
i
b
etween Acce
n
K
EY: This key
nt Light and S
w
fireplace (e
s
b
odily injury,
o
nctions
y
time a
n
g that the
m
ote
Pilot
w
hen presse
d
f three mode
s
e
room temp
e
no effect on
t
e
r On/OFF co
o
de, the firepl
o
m temperat
u
n
t Temperatu
r
a
ture, Press t
h
a
ture is displ
a
R
E window. T
lace startup
a
e
flames turn
o
n
be adjuste
d
s
peed can b
e
p
. Secondary
t
ime after sta
on or off an
y
d
e, all other f
u
d
justment are
f
unction adju
s
ctual room t
e
n automatica
i
ncrease or de
c
n
t Light ON/
O
is used to tog
g
econdary Bur
n
s
pecially the s
e
o
r even death.
d
after the O
N
s
: Manual O
p
e
rature is ign
o
t
his mode.
A
ntrol and Ac
c
ace
u
re in-
r
e. To
h
e UP
a
yed in
he fan
a
nd will
o
ff, in
d
while
e
ad-
burner
rtup.
y
time
u
nc-
allowed. Ma
n
s
ts the flame
h
e
mperature.
A
lly modulate
s
c
rease the Set
P
O
FF and Secon
d
g
le between th
e
n
er.
O
e
ction “Safety
N
/OFF KEY is
p
eration, Nor
m
o
red and the
f
A
ll other functi
c
ent Light ON
n
ual flame h
e
h
eight in acc
o
A
s the room t
s
the flame d
o
P
oint Tempera
t
d
ary Burner O
N
e
various func
t
O
FF
MANUAL
MODE
MAX
Hi
OFF 76°F
Precautions”
o
pressed an
d
m
al Thermos
t
f
ireplace can
ons such as
f
/OFF control
s
e
ight adjustm
e
o
rdance to th
e
emperature
g
o
wn.
t
ures, Flame
H
N
/OFF.
t
ion icons : Fl
a
O
N
NOR
M
THERM
O
H
MAX
7
ON
o
n page 2). F
a
d
the
t
at and
be turned O
N
f
an speed co
n
s
will be man
u
e
nt is not all
o
e
difference
b
g
ets closer to
H
eight and
a
me
N
M
AL
O
STAT
i
F
7
6°
6 | Pag
e
a
ilure
t
o follo
w
sys-
Smar
t
N
indefinitely.
n
trol, flame
u
ally controll
-
o
wed in this
b
etween the
the set point
SMART
SMART
MODE
68
SMART 76°F
e
w
t
-

85-0
3
R
E
TO
T
1.
P
2.
S
M
a
b
c
TO
T
Fla
m
heig
h
the fl
Fan
Aux
(
may
level
Seco
n
3
-00811
E
MOTE T
R
T
URN ON TH
E
P
ress the ON
/
S
elect the Th
e
M
ode), ON (
m
a
. In OFF (
M
b
. In ON (N
o
is greater
c
. In SMAR
T
than the
R
T
URN OFF T
H
MOD
E
Pressin
ble fun
c
On/Off
a
m
e Hei
g
ht: 6
Height
once
w
creme
n
ton is
p
pilot li
g
pilot lig
h
t function is
ame height r
e
Speed Cont
r
speed
s
Key to
Key to
will co
n
(
Accent-Li
g
h
t
Press
and
P
single
A
cce
n
Recei
v
A
cce
n
use the AU
X
.
n
dar
y
Burne
r
ture.
P
Burn
e
Burn
e
Burn
e
Level
R
ANSMI
T
E
APPLIANC
E
/
OFF button.
e
rmostat Mo
d
m
eaning nor
m
M
anual Mode
)
o
rmal Therm
o
than the Ro
o
T
(Smart Mo
d
R
oom Tempe
H
E APPLIA
N
E
KEY
g the MODE
c
tions: Flame
a
nd Second
a
flame heigh
t
Icon is dis
p
w
ill increase
o
n
ts. If the fla
m
p
ressed, all
b
g
ht will also
e
ht will remai
n
not available
e
gulates aut
o
r
ol: The fan
s
and OFF.
T
index to the
turn ON, O
F
n
firm recepti
o
t
): This functi
o
ing the UP k
e
P
ressing the
D
“beep” will
c
n
t Light Dim
m
v
er. Turn th
e
n
t Light. Onc
X
function to
r
: This functi
o
P
ressing the
U
e
r and Pressi
n
e
r. The flame
e
r On or Off.
T
mode.
T
TER OP
E
:
The transmi
t
d
e by pressin
g
m
al Thermost
a
)
, the applian
c
o
stat Mode),
t
o
m Temperat
u
d
e), the appli
a
rature.
N
CE, press t
h
KEY toggles
Height, Fan
S
a
ry Burner O
n
t
Levels are
p
layed, press
o
r decrease t
h
m
e height is
a
b
urners will t
u
e
xtinguish. If
n
ON. Note: I
f
for manual
a
o
matically.
speed can
T
o activate t
h
fan control i
c
F
F or adjust t
h
o
n of the com
m
o
n controls t
h
e
y in this mo
d
D
OWN key w
c
onfirm rece
p
m
er control i
s
e
Dimmer Co
e
you set y
o
turn the Acc
e
o
n controls t
h
U
P Key in thi
s
n
g the DOW
N
level will not
c
T
he flame le
v
ERATIN
G
t
ter display
w
g
the Therm
o
a
t) or Smart (
m
c
e will ignite
a
t
he appliance
u
re.
a
nce will only
h
e ON/OFF
b
between the
S
peed, Aux (
A
n
/Off.
available.
W
ing the Up
o
h
e flame hei
g
a
t Level 1 an
d
u
rn OFF. If i
n
in Standing
f
in SMART
m
a
djustment. I
n
be adjusted
h
is function,
p
c
on. Use the
h
e fan speed
m
and.
h
e Mendota
A
d
e will TURN
ill TURN OF
F
p
tion of the c
o
s
located adj
a
ntrol Knob t
o
o
ur desired
b
e
nt Light On
h
e Secondar
y
s
mode will
T
N
Key will T
U
c
hange whe
n
v
el can only
b
G
INSTR
U
w
ill show all a
c
o
stat Key: OF
m
eaning Sm
a
a
nd start on
H
will only igni
t
ignite if the
S
b
utton.
various avail
A
ccent Light
)
W
hile the Fla
m
o
r Down but
t
g
ht by 1 of 6
d
the Down
b
n
IPI mode,
t
Pilot Mode,
t
m
odel, the fla
m
n
SMART mo
d
through six
p
ress the M
O
UP/Down A
r
. A single “b
e
A
ccent Light f
ON the Acc
e
F
the Accent
o
mmand. N
o
a
cent to the
o
dim or brig
h
b
rightness le
v
or Off at tha
y
Burner’s O
T
URN ON th
e
U
RN OFF the
n
you turn th
e
b
e changed i
n
U
CTIONS
c
tive icons o
n
F (meaning
M
a
rt Mode).
H
I.
t
e if the Set
T
S
et Temperat
u
a-
)
m
e
t
on
in-
b
ut-
t
he
t
he
m
e
d
e,
(6)
O
DE
r
row
e
ep”
unction.
e
nt Light
Light. A
o
te: The
Remote
h
ten the
v
el, you
t preset
N/OFF fea-
e
Secondary
Secondary
e
Secondary
n
the Flame
7
5
n
the screen.
M
anual
T
emperature
u
re is greate
r
5
r
7 | Pag
e
e

85-0
3
M
A
If th
e
thre
e
feat
u
spe
e
To t
u
swit
c
TE
M
1.Pr
e
2.Si
m
Ke
3.Lo
o
o
C
)
KE
Y
To p
r
with
t
“MO
D
the “
M
Duri
n
b
efo
r
LO
W
1.
T
o
t
t
b
2.
R
t
t
e
T
T
r
OP
This
the
A
batt
e
ond
a
pow
e
This
redu
c
3
-00811
A
NUAL B
Y
e
remote tran
e
position slid
e
u
re of the sys
t
e
d and the Ac
c
u
rn off the ap
p
c
h on the rec
e
M
PERAT
U
e
ss the ON/
O
m
ultaneously
,
y.
o
k at the LC
D
)
is being displ
Y
LOCK
F
r
event unsuper
v
t
his remote co
n
D
E KEY” an
d
M
ODE KEY”
n
g KEY LOC
K
r
e you can use
t
W
BATT
E
T
ransmitter
B
o
n various fa
c
he number o
f
eries are low
,
b
attery powe
r
R
eceiver Ba
t
he batteries
h
hese batterie
e
ven when n
o
T
he batterie
s
T
o replace or
r
ies in correct
ERATIN
G
electronic ig
n
A
C power is i
n
e
ries. During
t
a
ry Burner O
N
e
r, will not fu
n
appliance is
d
c
ed by appro
x
Y
PASS
O
smitter is mi
s
e
r switch on
t
t
em and the
a
c
ent Light m
a
p
liance, if the
e
iver to the O
U
RE IND
I
O
FF Key and
T
,
Press both
t
D
display to v
e
ayed. If not, r
e
F
UNCTI
O
v
ised children
n
trol system.
T
d
the “UP KE
Y
and the “UP
K
K
mode, none
o
t
he Remote T
r
E
RY PO
W
B
atteries: T
h
c
tors: quality
o
f
changes to
t
,
a Battery Ic
o
r
is lost. Whe
n
t
teries: The l
h
ave been in
s
s every heati
o
t in use. Thi
s
s
are to be i
n
add batterie
s
polarity posi
t
G
DURIN
G
n
ition system
n
terrupted du
t
he power o
u
N
/OFF functi
o
n
ction.
d
esigned an
d
x
imately 5%
w
O
F THE R
E
s
placed or lo
s
t
he receiver t
o
a
ppliance’s
m
a
y turn on.
remote cont
r
FF Position.
I
CATOR
T
urn Off the
F
t
he MODE K
e
e
rify that you
r
e
peat step 2.
O
N
from operatin
g
T
o activate the
Y
”. To deactiva
t
K
EY”.
o
f the Keys wi
l
r
ansmitter.
W
ER DET
E
h
e life span o
f
o
f the batteri
e
t
he room the
r
o
n will appea
r
n
the batterie
s
ife span of th
s
talled in the
r
ng season e
v
s
is a normal
c
n
stalled in th
e
s
, remove the
t
ions and clo
s
G
POWE
R
utilizes the
s
ring a power
u
tage, the ap
p
o
ns will be a
v
d
tested to be
w
hen the blo
w
E
MOTE
S
s
t, the applia
n
o
the ON po
s
m
ain burner w
i
r
ol is misplac
e
(oF or oC
)
F
ireplace.
e
y and the Th
r
desired indi
c
g
the fireplace
,
KEY LOCK
fu
t
e the KEY L
O
l
l function. Yo
E
CTION
f
the remote
c
e
s used, the
n
r
mostat set p
o
r
on the LCD
s
are replace
d
e receiver b
a
r
eceiver. Th
e
v
en if you ha
v
c
haracteristi
c
e
receiver w
Glass Fram
e
s
e the batter
y
R
OUTA
G
s
upplied 110
V
outage, this
s
p
liance’s bur
n
v
ailable. The
operated du
r
w
er function i
S
YSTEM
n
ce can be tu
r
s
ition. This wi
l
i
ll turn on. Th
e
e
d or lost, sli
d
)
ermostat
c
ator (
o
F or
,
a KEY LOC
K
fu
nction, simul
t
O
CK function,
u must DEAC
T
c
ontrol trans
m
n
umber of ig
n
o
int, etc. Wh
e
display of th
e
d
, this icon w
a
tteries depe
n
e
se batteries
a
v
e not experi
e
c
of all batteri
e
hich is locat
e
first then re
m
y
compartme
n
G
ES
V
AC power
w
s
ystem utiliz
e
n
ers will fun
c
Fan and Ac
c
r
ing power o
u
s disabled d
u
r
ned on man
u
l
l bypass the
e
fan will run
d
e the three
p
K
function is p
r
t
aneously pres
simultaneousl
y
T
IVATE the s
y
m
itter batteri
e
n
itions of the
a
e
n the Trans
m
e
Transmitter
ill disappear.
n
d on the qua
a
re only utiliz
e
e
nced any po
w
e
s.
ed on the le
f
m
ove the bat
t
n
t cover.
w
hen it is av
a
e
s the batteri
e
c
tion. In addit
i
c
ent Light,
w
u
tages. The
o
u
ring the pow
e
u
ally by slidin
remote contr
o
at its maxim
u
p
osition slide
r
r
ovided
s the
y
press
y
stem
e
s depends
a
ppliance,
m
itter bat-
before all
lity of the bat
t
e
d during po
w
w
er outages.
f
t side unde
r
t
ery compart
m
a
ilable for all
e
s (installed i
n
i
on, Flame H
w
hich are wh
o
o
verall efficie
n
e
r outage pe
r
g the
o
l
u
m
r
t
eries used a
w
er outages.
Batteries dr
a
r
the Pilot Li
g
m
ent cover. I
n
functions of
t
n
the Receiv
e
eight adjust
m
o
lly depende
n
n
cy of this ap
p
r
iod.
8 | Pag
e
nd how long
Replace
a
in slowly
g
ht Switch.
n
sert batte-
t
his system.
I
e
r) as back-u
p
m
ent and Se
c
n
t on 110VA
C
p
liance will b
e
e
I
f
p
c
-
C
e

9 | Page
85-03-00811
“FIRST TIME” PILOT LIGHTING INSTRUCTIONS
IMPORTANT: Be sure all items on "INSTALLATION CHECK OFF LIST" in the Installation Manual have been completed!
CAUTION: If the pilot goes out, be sure to wait a minimum of five minutes before attempting to relight the pilot.
1. Make certain that any manual gas supply shut-off valves located upstream of fireplace are open and the receiver and the remote
control transmitter are in the "OFF" position. Make certain that the receiver harness is connected to the receiver properly.
2. Make certain that 120VAC power cord is connected to an electrical outlet.
3. Insert Batteries in the Receiver and the Remote Transmitter. Note the polarity of batteries and insert as indicated on the battery
compartment cover.
4. For the “First Time Lighting”, Remove the Glass Door. This is required to purge the gas line of air and to inspect the pilot light-
ing spark.
5. Slide the receiver switch to “REMOTE”. Locate the “Standing Pilot ON/OFF Switch”. See Figure, above. Toggle “Standing Pilot
ON/OFF Switch” to “ON”. You will hear a series of clicks and after a few seconds, you will hear sparking at the pilot spark elec-
trode.
6. Allow adequate time for the air in the gas-line to purge. The control system will stop sparking after 30 seconds if the pilot light
does not light. After a 30 second delay the control system will start sparking again for 30 seconds more. If the pilot light does not
light after the third 30 second spark event, the system will enter “Lock-out” mode. To unlock from “Lock-out” mode, slide Re-
ceiver Switch to “OFF”, wait 30 seconds and slide back to “Remote”. Repeat this sequence until the pilot flame lights and the pi-
lot is burning steadily.
LOCK OUT MODE: If the pilot light does not light after the third 30 second spark event, the system will enter “Lock-out” mode. To
unlock from “Lock-out” mode, slide Receiver Switch to “OFF”, wait 30 seconds and slide back to “Remote”.
7. Once the pilot flame is lit and well-established, close glass door. WARNING: NEVER IGNITE MAIN BURNERS WITH
GLASS DOOR REMOVED OR OPEN. Doing so will lead to damage to pilot flame sensor and spark electrode wire leads.
8. Slide switch on Receiver to “ON”. All burners should ignite and run at “high-fire”. Slide Receiver switch to REMOTE after 15
seconds. Burner Flames will extinguish.
9. Perform gas inlet and outlet pressure tests and leak tests on field installed gas fittings and factory installed fittings in the gas valve
compartment, at this time. Note: Burners must be ON to check outlet pressures and to leak test gas train fittings upstream of main
gas valve.
OFF
ON
REMOTE CONTROL
RECEIVER MODULE
STANDING PILOT
LIGHT ON/OFF SWITCH

10 | Page
85-03-00811
INITIALIZING THE REMOTE CONTROL SYSTEM
(Synchronizing Receiver and Transmitter)
1. Place 3-position slider switch in Receiver in
the “Remote” position.
2. Locate “PRG” key on Receiver Face. Use
the tip of a pen/pencil or a wire clip to push
the PRG button. The receiver will beep 3
times indicating that it is ready to synchron-
ize with a Remote Transmitter.
3. Push the “ON” key on the Remote Trans-
mitter. The receiver will beep 4 times to in-
dicate that the Transmitter’s command is
accepted and sets to the particular code of
that Transmitter. The system is now initia-
lized.
NOTE: Use this Synchronizing procedure every
time the batteries are replaced in the Receiver
or the Transmitter.
IPI/STANDING PILOT SYSTEM INFORMATION
Intermittent Pilot Light and Standing Pilot Light Features
This gas fireplace is equipped with an electronic ignition System that first
lights a pilot light then uses the pilot light to ignite the main burners. The
pilot light can be set in the “Standing Pilot” mode to allow the pilot light to
remain on indefinitely by toggling the “Standing Pilot Switch” to the ON posi-
tion. If the “Standing Pilot Switch” is toggled to the OFF position, the pilot
light will only light and remain ON while the main fireplace burners are oper-
ating.
IPI Mode: This mode turns the pilot light “OFF” when the fireplace is not
functioning and only lights the pilot light automatically when a
call for heat is made by the remote control.
Standing Pilot Mode:If the “Standing Pilot Switch” is toggled to ON,
the pilot light will ignite and remain ON as long as the “Stand-
ing Pilot Light Switch” is in the ON position.
NOTE: Mendota Fireplaces recommends that the Standing Pilot Mode
be used during the winter months when external temperatures fall be-
low 50oF. This will keep the fireplace chimney heated for proper updraft dur-
ing burner ignition and it will also eliminate excessive condensation of
exhaust vapors on the door glass. Further, leaving the fireplace in the
Standing Pilot Mode will keep the fireplace body warm and eliminate cold drafts and heat loss to the cold air that is
trapped inside the firebox.
REMOTE CONTROL RECEIVER
Supply voltage 4.5V (three 1.5V AAA batteries) 6.0V (four 1.5V AA batteries)
Ambient temperature ratings 32 – 122 oF (0 – 50 oC) 32 – 140 oF (0 – 60 oC)
Radio Frequency 315 MHz 315 MHz
BATTERY
COMPARTMENT
LID
3-POSITION
SLIDER SWITCH
PRG KEY
PRG
WALL RECEIVER
REMOTE TRANSMITTER
BLUE LCD
DISPLAY
MODE
SELECTION KEY
UP/DOWN
SELECTION KEY
THERMOSTAT
SELECTION KEY
ON/OFF KEY
OFF
ON
REMOTE CONTROL
RECEIVER MODULE
STANDING PILOT
LIGHT ON/OFF SWITCH

11 | Page
85-03-00811
2.) PULL
3.) ROTATE
4.) RELEASE
1.) INSERT
DOOR REMOVAL AND REPLACEMENT
CAUTION: Do not operate the appliance with glass removed, cracked or broken. Replacement of the glass should be
done by a licensed or qualified service person. Glass latch tool #HA-57-00743 is supplied with the unit.
To Unlatch Glass Frame Latches:
1. Insert Glass Latch Tool into hole in latch (two latches exist
at top of glass frame).
2. Pull Glass Latch Tool outward about 3/8”.
3. Rotate Glass Latch Tool 90 degrees.
4. Release Glass Latch Tool.
5. Remove Glass Latch Tool.
To Latch Glass Frame Latches, reverse steps 5 to 1,
above.
To Remove Glass Frame:
a. Rotate top edge of freed glass frame outward about 15
degrees.
b. Lift Glass Frame Up and Out.
To Install Glass Frame:
1. Align and insert tabs in side flanges of Glass Frame into Slots into the slot in the base plate.
2. Rotate Glass Frame upward until vertical.
3. Latch Glass in place per instructions above.
SLIDE TAB INTO
SLOT IN BASEPLATE

12 | Page
85-03-00811
BLOWER OPERATION AND WIRING
WARNING: The Power Cord supplied with this appliance must be connected to a 3-prong grounded LIVE out-
let. No switches, Light Dimmers or Fan Speed Control Devices are allowed within the same electric circuit as
this appliance. Connect only to a LIVE outlet that is not controlled by any other switching device.
Dual blowers are provided as standard equipment with this FV-33i Insert. The dual blowers have an air output rating of
210 CFM (in free air). This Insert is designed to operate with the blowers turned OFF or ON. Turning the blower on
increases the overall efficiency of this fireplace and aids in distributing and circulating heat to the room this Insert is
installed in.
BLOWER BREAK-IN PERIOD: The integrated blowers in this Insert may exhibit some bearing noise and electrical
static noise during the first few hours of operation. This is normal during the break-in period. It is recommended that
following the Paint Curing Cycle, the blowers be run at their maximum speed for two 3-hour periods. The burner flames
may be on or off during these cycles. The blowers in a few inserts may take longer to break-in and may require addi-
tional operation time before all extraneous noise is eliminated. Please allow adequate operational time for the blowers
to break-in before you contact your dealer for service.
BLOWER OPERATION
The remote control system supplied with this appliance can turn the blowers ON or OFF and regulate the speed of the
blowers in six (6) steps.
NOTE: In the Normal Thermostat Mode and the SMART Mode, there will be a time delay in blower operation during
"heat-up" (5 minutes) and extended blower operation during "cool-down" of unit (12-1/2 minutes).
The blowers are ideal for owners who wish to maximize the heating capacity and efficiency of Mendota Gas Fireplaces.
The blowers greatly increase total heating capacity by forcefully moving hot air away from the fireplace and mantel area
and out into the room. The blowers increase the overall efficiency of the Mendota units by up to 5%.
WARNING: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN
CAUSE IMPROPER AND DANGEROUS OPERATION. VERIFY OPERATION AFTER SERVICING.
This appliance is equipped with a three-prong (grounding) plug for protection against shock hazard and
should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the
grounding prong from the plug.
FV-33i BLOWER WIRING DIAGRAM

13 | Page
85-03-00811
MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM
As a part of Mendota's on-going program of customer satisfaction, this Form verifies proper installation and operation. It is im-
portant as a reference for future service. It insures long life and trouble-free operation of Mendota fireplaces & stoves and quali-
fies the owner for Mendota's lifetime limited warranty. Owner should sign Form when completed and mail a copy along with
Warranty Registration to Mendota. OPTIONALLY, PLEASE REGISTER AT OUR WEBSITE AT:
WWW.JOHNSONGAS.COM/MENDOTA-REGISTRATION.ASP
HOME OWNER: ________________________________ DEALER: _________________________________
ADDRESS: ____________________________________ ADDRESS: _______________________________
CITY/STATE/ZIP: ______________________________ CITY/STATE/ZIP: __________________________
SIGNATURE: __________________________________ PHONE: __________________________________
MODEL #: FV33I SERIAL #: _______________ DATE INSTALLED: ________________________
Mendota direct vent fireplaces are sophisticated, hi-tech gas appliances. All installation and operating instructions must be carefully
followed. This FV33I fireplace insert must be installed and serviced by a qualified Mendota approved service person.
REF:___________________MENDOTA FV33I INSTALLATION MANUAL
APPROVED VENT PIPES AND VENT CAP INSTALLED - Per Manual.
CHECK FOR PROPER CLEARANCES TO COMBUSTIBLES & VENT LOCATIONS - Per Manual
INSTALL PROPER SIZE GAS LINES - CHECK FOR GAS LEAKS - Per Manual
CHECK FOR CORRECT GAS PRESSURE AT MANIFOLD - Per Manual
a. 3.5 Inches Water Column Maximum - Nat. Gas
b. 10.0 Inches Water Column Maximum - L.P. Gas
CYCLE BURNERS ON/OFF FOR PROMPT IGNITION - Per "LIGHTING INSTRUCTIONS"
Burner must light IMMEDIATELY - Flame must promptly light burner.
INSTALL LOGS AND ADJUST FLAME - Per Manual
Proper pilot flame impingement on flame sensor rod & burner - Air shutter opening: 1/8" Nat. Gas – 1/4-“-1/2" LP
Check that flames are "stable" and are not "lifting" off burner
BRIEF OWNER ON OPERATION AND MAINTENANCE OF UNIT
Light Pilot Operate Burner Train on Remote Control Functions Explain Thermostatic Functions
WARRANTY REGISTRATION
Your Name_______________________________________________________________________
Address _________________________________________________________________________
City ________________________________________State ______Zip______________________
Dealer (Place of Purchase)___________________________________________________________
City ________________________________________State ______Zip______________________
Date of Purchase _______________________Serial Number_______________________________
Purchaser's Signature_______________________________________________________________
MENDOTA FV33I DIRECT VENT FIREPLACE INSERT
CUT OUT PAGE AND MAIL TO: JOHNSON GAS APPLIANCE CO., 520 E AVE. N.W., CEDAR RAPIDS, IOWA 52405
PLEASE REGISTER AT OUR WEBSITE AT: WWW.JOHNSONGAS.COM/MENDOTA-REGISTRATION.ASP

14 | Page
85-03-00811
TAPE SHUT
--------------------------------------------------------------------------------------------------------------------------------------------------------
JOHNSON GAS APPLIANCE COMPANY
520 E AVENUE N.W.
CEDAR RAPIDS, IA 52405
POSTAGE
NEEDED

15 | Page
85-03-00811
MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY
MENDOTA FV33I DIRECT VENT FIREPLACE INSERT
Mendota Division of Johnson Gas Appliance Company, 520 E Avenue N.W. Cedar Rapids, Iowa 52405, extends this Extended Lifetime Protection and Li-
mited Warranty to the original purchaser of a Mendota FV33I Fireplace, which is limited and used under normal home conditions.
STANDARD WARRANTY:
JOHNSON GAS APPLIANCE CO., MENDOTA DIVISION, WARRANTS THAT YOUR NEW MENDOTA FIREPLACE IS FREE FROM
MANUFACTURING AND MATERIAL DEFECTS FOR A PERIOD OF ONE YEAR FROM THE DATE OF INSTALLATION, SUBJECT TO THE
FOLLOWING CONDITIONS AND LIMITATIONS:
EXTENDED LIFETIME WARRANTY:
THE HEAT EXCHANGER, BURNER TUBE COMBUSTION CHAMBER AND OUTER SHIELD OF THE MENDOTA FV33I FIREPLACE ARE
WARRANTED FOR THE LIFETIME OF THE ORIGINAL OWNER, SUBJECT TO PROOF OF PURCHASE AND THE FOLLOWING CONDITIONS
AND LIMITATIONS:
1) This new Mendota Fireplace must be installed & serviced by a competent, authorized service contractor. It must be installed and operated at all times
in accordance with the installation and operating instructions furnished with the Fireplace. All adjustments to logs, coals or burner must be made by
an authorized Mendota person. Any alteration, willful abuse, accident or misuse of the product shall nullify this warranty. This warranty does not
cover glass or log breakage.
This limited warranty does not cover the cost of service calls, the cost of labor to remove or install parts covered by this limited warranty, freight or
other transportation expenses, which may be incurred in connection with obtaining performances under this limited warranty. The remedy for dam-
ages as the result of any defects in this product which have been warranted herein is limited to replacement parts and does not include any incidental,
indirect or consequential damages or expenses sustained in connection with the product, including damages to property, except as provided by law.
2) This warranty is non-transferable and is made to the original retail purchaser, provided the purchase was made through an authorized Mendota dealer.
Mendota is not responsible for any damage to or malfunction of the Fireplace unless caused by a defect in material or workmanship from normal
home use. Damage caused by abuse, improper installation, improper servicing, and installation by unqualified personnel or breech of conditions of
this limited warranty will excuse Mendota from performance of any part of this limited warranty. Mendota has the right to investigate and inspect the
exact, original Fireplace and entire installation (without any alterations or tampering) in the event a claim is made to determine whether the claimed
damage or malfunction was caused by abuse, improper installation or other cause outside this warranty. Mendota is not responsible for any repairs
or material purchases that have not received prior written approval from Mendota.
NOTE: Minor warping of certain parts or discoloration is normal and is not a defect covered by this warranty. Major warping of parts can be caused by
over-firing of your Mendota Fireplace. Over-firing above rated nameplate specification is as contrary to the manufacturer's instructions and may
void this warranty.
This warranty may not be extended by our representatives or any third party in any manner. The company neither assumes, nor authorizes any third
party to assume, on its behalf, any other liabilities with respect to the sale of this Mendota product.
3) Mendota may at its discretion, fully discharge all obligations of this warranty by refunding the wholesale price of the defective part(s).
4) All other warranties - expressed or implied - with respect to the product, its components and accessories, or any obligation/liabilities on the part of the
company are hereby expressly excluded. Products made by other manufacturers, sold with the Fireplace or thereafter, are not covered by this limited
warranty. The use of unauthorized components will make this warranty null and void.
This warranty shall be effective only if the original purchaser of the Mendota appliance is registered with Mendota Division within thirty (30) days of the
date of purchase. Such registration or the failure to register shall not be deemed to create any obligation or liability by the manufacturer and this warranty
with its conditions and limitations shall be the only procedure for obtaining any rights against the manufacturer and expresses the sole obligation and re-
sponsibilities of the manufacturer which are offered to the original purchaser and accepted upon purchase of the appliance.
Mendota Division, reserves the right to make changes at any time without notice, in design, material, specifications, prices and the right to discontinue styles
and products.
Some states do not allow the exclusion of limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the
above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state
to state.

Johnson Gas Appliance Company
520 E Avenue N.W. - Cedar Rapids, IA 52405
Mendota Hearth Division
WEBPAGE: www.johnsongas.com or www.mendotahearth.com
Other manuals for FV-33i
3
Table of contents
Popular Gas Heater manuals by other brands

Jøtul
Jøtul Allagash GF 300 DV Installation and operation instructions

FMI
FMI EMBER MASTER VFN18R OWNER'S OPERATION AND INSTALLATION MANUAL

SUNWIND
SUNWIND PG113H-A instruction manual

Immergas
Immergas DIM 2 ZONE ErP Instructions and warnings

Desa
Desa CBN20, CBP20, SBN20, SBP20, CB Safety and installation manual

HEATSTRIP
HEATSTRIP TGH34PL Operation, installation, and maintenance manual

Immergas
Immergas ARES 150 TEC ERP user manual

Salton
Salton SGH12 user manual

Solaronics
Solaronics Residential Garage Heater instruction manual

Desa
Desa Glo-Warm FB-5B OWNER'S OPERATION AND INSTALLATION MANUAL

Superior
Superior VFGT24NR Installation and operation instructions

Eskabe
Eskabe S21 Mini 3 Operation and installation manual