METRACLARK ICE BABY IM Series User manual



CONTENT
Introduction 1
Safety Tips 1
Structure 2
Accessory 2
Control Panel 3
Installation 3
Operation 3
Cleaning and Maintenance 4
Technical Parameters 5
Troubleshooting 5
Circuit Diagram 7

Introduction
Please take a few moments to carefully read through this manual. Correct
maintenance and operation of this machine will provide the best possible
performance.
Safety Tips
• Position on a flat, stable surface.
• A service agent/qualified technician should carry out installation and any
repairs if required. Do not remove any components or service panels on this
product.
• DO NOT immerse in water, or use steam/jet washers to clean the unit.
• DO NOT cover the appliance when it is operating.
• DO NOT place the appliance near flammable materials and be sure fine
ventilation.
• DO NOT lay the cable over carpets or heat insulations. Do not cover the cable.
Keep away the cable from operating range and do not dunk it into water.
• Always carry, store and handle the appliance in a vertical position.
• Never tilt the appliance more than 45° from the vertical.
• ONLY use drinking or potable water when making ice cubes.
• Ensure the water pressure of the connected water supply is between 1kg/cm²
to 8kg/cm² (14.7-117psi).
• The device is to be used indoors only.
• Keep all packaging away from children. Dispose of packaging in accordance
to the regulations of local authorities.
• If the power cord is damaged, it must be replaced by a recommended qualified
technician in order to avoid a hazard.
• The separate three-pole socket should be used and it must be grounded.
• The rated capacity of wire should be over 6A, but for the IM-80, it
2
should be over 10A, the section area of the wire is 0.75mm . But for
2
the IM-80, it should be over 1.0mm . The wire could be consisted by
single ply or multiplies.
·1·
IM Series Automatic Ice Maker

·2·
1 Switch
4 Shelf
7 Ice Storage Cabinet
10 Screw for Drainage
Water Inlet Tube
Ice Spoon
Sealing Washer
Water Drainage Pipe
Accessory
φ12
2 Display Panel
5 Water Cabinet
8 Power Cord
11 Water Outlet Connector
3 Slide Door
6 Ice Full Sensor
9 Water Inlet Connector
12 Foot
Structure
IM Series Automatic Ice Maker

Control Panel
Installation
1.Remove the appliance from the packaging and remove the protective film from
all surfaces.
2.Remove the Ice Spoon, Water Inlet Tube, Water Drainage Pipe and Sealing
Washers from the ice storage cabinet.
3. Place the device on top of an even and safe surface which supports the weight of
the device.
4. Choose a surface where the ice maker is not exposed to direct sunlight, or close
to a direct source of heat such as a cooker, oven or radiator.
5. When positioning the ice maker, maintain a distance of 20cm
(7 inches) between the appliance and walls or other objects for
ventilation. Increase this distance if the obstacle is a heat source.
6. Position the device in a way so that the power plug is always accessible.
7. Set up the device near water supply connection.
8. If necessary, adjust the screw legs of the ice maker to make it level. The
efficiency of the ice maker can be reduced if the appliance is unevenly located.
9. Connect one end of the Water Drainage Pipe to the water outlet
connector on the rear of the ice maker.
10. Attach the other end of the pipe to a plumbed in stand waste pipe
or container suitable for collecting waste water.
11.Connect one end of the Water Inlet Tube to the 3/4" screw type connector
of the water tap so as to get the drinkable tap water. Be sure to put
sealing washers in both ends of the water inlet tube before connecting.
12. Connect the other end of the inlet tube to the water inlet connector.
Operation
Note: If using the ice maker for the first time (or after a period of inactivity) please
·3·
RUN
FAULT WATER
L0W
I
O
POWER SWITCH
ICE
FULL
IM Series Automatic Ice Maker

discard the first two batches of ice. This cleans the internal systems of the ice
maker.
1. Connect the device to a grounded single power socket.
2. Press the Power switch to the ON position [I]. The Switch light illuminates and
the appliance start to work. The first 5 minutes is used for the self-inspection
of the ice maker. Then it will begins the ice making process.
3. As soon as the ice storage cabinet is full, the “ICE FULL” indicator on the
display panel will light on and the ice maker will stop automatically. Production
resumes once ice has been removed from the cabinet.
4. If water supply is insufficient, the “WATER LOW” indicator will light on and
the ice maker will stop operation automatically.
5. If any error or failure occurs, the “FAULT” indicator will light on and the ice
production stops.
6. Switch off the device and disconnect it from power supply (Pull the power
plug!), when it is not in use.
7. Do not switch on the device immediately after it stops automatically (caused by
insufficient water supply, ice storage cabinet too full, current interruption). Wait at
least 3-5 minutes before restart it in order to avoid damages of the compressor.
NOTE: If the device is not used for a longer period of time, drain the water from
the water tank via the drain screw at the back of the device (some model no drain
screw). Wipe dry the water tank using a dry cloth.
Cleaning and Maintenance
• Always switch off and disconnect the power supply before cleaning.
• Warm, soapy water is recommended for cleaning. Cleaning agents may leave
harmful residues.
DO NOT wash the base unit, instead wipe the exterior with a damp cloth.
•Check regularly the connectors of the water inlet and outlet tubes and
drain the little surplus water that may leak.
•If the ice make will be unused for a long period, please switch off the
power switch and wipe the inner liner of the ice storage container with a
clean rag.
• When plugging or unplugging, the plug should be held by hand and the
wires should not be dragged heavily.
·4·
IM Series Automatic Ice Maker

·5·
Troubleshooting
Note: If any trouble occurs, please wait till the machine stop automatically;
Follow list will be helpful for you to know the machine troubles, but only
authority person can open and check or repair the machine!
·The RUN light does not come on when switch on the machine at first time,
it will light when the compressor is running.
·This ice maker has an advantage self-checking function, every fault will
be displayed in the display panel with the different lights flash.
IM-20 202005
IM-25 25 2407
IM-25A
25 2407
IM-50
5032013
Model
Ice making
capacity
(kg/24h)
Power
Input
(W)
Ice Storage
(kg)
Dimensions
(mm)
( for reference of users and technicians )
Technical Parameters
(tested under the conditions of ambient temperature 15℃ and water temperature 10℃ )
The specifications are subject to be changed without notice.
Please check the nameplate for sure.
IM Series Automatic Ice Maker
IM-100 100 64055
IM-120 120 78055
682×610×1050
682×610×1050
IM-50B 50 3207
IM-8$ 80
48055
330×503×607
398×542×682
398×512×786
548×610×823
398×542×682
682×610×1050
IM-80 80 48013 548×610×823
IM-50A 50 32025 500×610×893

·6·
·Device dose not work
(Without any lights
come on)
·Power supply is interrupted
·Power supply voltage is not
correct
·Check the power supply
·Cut off the power supply
·Device dose not
work (Only switch
light come on)
·Power supply voltage is not
correct
·PCB board damaged
·Cut off the power supply
·Replace it
·Device dose not
work (The ice full light
come on)
·Ice full occur
·Ambient temperature is below 6℃
·Remove the ice cubes from basket
·Keeping the ambient temperature is
more than 7℃ , restart it
·Device dose not
work (ice full and fault
flash together)
·Ice full sensor damaged or
does not connected
·Replace or connect this sensor
·Device dose not work
(fault light flash)
·condenser sensor damaged or does
not connected
·Replace or connect this sensor
Water low and ice full
flash together or the
fault flash rapidly
·Refrigerant leaked
·Compressor does not run
·Ambient temperature is below 6℃
·Check and recharge
·Compressor damaged or the ambient
temperature is higher than 43℃
·Keeping the ambient temperature over
7℃ , restart it
·Fault, water low, ice
full three lights flash
slowly
·the HALL sensor is not in correct
position or damaged.
·paddle motor damaged
·adjust the position or replace it.
· replace it
·Only the fault light
flash rapidly (after
working a period.)
·Turn ice motor damaged
·Micro-switches do not function.
·Water box broken
·Water box was blocked by ice
cubes
·Replace it
·Replace or adjust position again
·Replace it
·Remove the ice cubes
·Device stop after 2
minutes or more. (The
water low light flashes)
·Without water in water supply
source
·Water inlet valve damaged or does
not connect
·water level sensor not in correct
position
·waiting for water supplying
·Check valve connecting or replace it.
·Water low light
always come on
·without water supply for more then
24 hours
·stop the machine and restart it if water
supply is ready
·Ice cubes stick in the
water box
·The electric valve does not
function
·Some ice remain in the water box
·Check the valve electrical connecting
or replace it
·Stop the machine and move it
·No ice making no
fault indication
·The electric valve was leak
·Compressor does not run
·Replace it.
·Ask service
·Ice cubes are not
very equal
·Refrigerant leak ·Recharge it
Problem Possible Cause Suggested Solution
IM Series Automatic Ice Maker

·
7·
Circuit Diagram
IM Series Automatic Ice Maker
IM-20 IM-25 IM-25A IM-50 IM-50B IM-80A
Circuit Diagram×2
IM-100 IM-120


This manual suits for next models
10
Table of contents
Popular Ice Maker manuals by other brands

Manitowoc
Manitowoc TIMER GSI 200 installation instructions

KitchenAid
KitchenAid KUIS18NNJB8 parts list

icetro
icetro WU-0100A Technician's handbook

Hoshizaki
Hoshizaki Serenity Series KMS-822MLH instruction manual

Royal Sovereign
Royal Sovereign RIM-HD-13SS owner's manual

Clatronic
Clatronic EWB 3785 instruction manual