manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MG
  6. •
  7. I/O System
  8. •
  9. MG M2BS-16U0 User manual

MG M2BS-16U0 User manual

BEFORE USE ....
Thank you for choosing us. Before use, please check con-
tents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact our sales office or representatives.
■PACKAGE INCLUDES:
Installation base..................................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■NONINCENDIVE APPROVAL OPTION
• This equipment is suitable for use in Class I, Div. 2,
Groups A, B, C and D or Non-Hazardous Locations only.
• WARNING! Before You Remove the Signal Conditioner
from Its Base or Mount It, Turn Off the Power Supply
and Input Signal for Safety.
• WARNING! – Explosion Hazard –
Substitution of Components May Impair Suitability for
Class I, Div. 2.
• WARNING! – Explosion Hazard –
Do Not Disconnect Equipment Unless Power Has Been
Switched Off or The Area is Known To Be Non-Hazardous.
• The equipment was evaluated for use in the ambient tem-
perature and relative humidity as mentioned in ‘ENVI-
RONMENT’ section.
• The input and output wiring must be in accordance with
Class I, Div. 2 wiring methods and in accordance with the
authority having jurisdiction for use in these hazardous
locations.
■CONFORMITY WITH EU DIRECTIVES, UK LEGISLATION OR UL
• This equipment is suitable for Pollution Degree 2 and In-
stallation Category II (transient voltage 2500V). Rein-
forced insulation (signal input or output to power input:
300V) and basic insulation (signal input to output: 300V)
are maintained. Prior to installation, check that the insu-
lation class of this unit satisfies the system requirements.
• Voltage at the field I/O terminals (except power input ter-
minals) limited within 30V DC for UL.
• The equipment must be mounted inside a panel.
• Altitude up to 2000 meters.
• The equipment must be installed such that appropriate
clearance and creepage distances are maintained to con-
form to CE/UKCA/UL requirements. Failure to observe
these requirements may invalidate the CE/UKCA/UL
conformance.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE/
UKCA requirements in regard to the whole system and
employ additional protective measures* to ensure the
CE/UKCA conformity.
* For example, installation of noise filters and clamp
filters for the power source, input and output connected
to the unit, etc.
• Install lightning surge protectors for those wires connect-
ed to remote locations.
■POWER INPUT RATING & OPERATIONAL RANGE
• Refer to signal conditioner data sheet. Choose the same
power input specification for all units.
■GENERAL PRECAUTIONS
• Before you remove the unit from the base or mount it,
turn off the power supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
• Be sure that the ventilation slits are not covered with ca-
bles, etc.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
MOUNTING REQUIREMENTS unit: mm (inch)
100 (3.94)
460 (18.11)
4–M5 SCREW
INSTALLATION BASE
(16 positions; screw terminal block) MODEL
M2BS-16U0
EM-5005-U0 Rev.7 P. 1 / 3
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
INSTRUCTION MANUAL
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
58
14
58
14
58
14
58
14
58
14
58
1
CH5CH1
4
58
14
58
14
58
14
58
14
58
FG
14
13 14
12345
5858585858
6789
10
1414141414
11 12 13 14 15 16
CH10CH6 CH16CH11
9
12
CH11 CH12 CH13 CH14 CH15 CH16
9
12
9
12
9
12
9
12
9
12
9
12
CH6 CH7 CH8 CH9 CH10
9
12
9
12
9
12
9
12
9
12
CH1 CH2 CH3 CH4 CH5
9
12
9
12
9
12
9
12
CT PROTECTOR (CTM2)
**
130 (5.12)
100 (3.94)
6 (.24)
440 (17.32)
460 (18.11)
480 (18.90)
27 (1.06)
2–M3 POWER
TERMINALS
64–M3 INPUT TERMINALS
125 (4.92)
*
*
165 (6.50) required for pneumatic tubing for M2PV.
**
Attached to M2CA and M2CE.
6 (.24)
32–M3 OUTPUT TERMINALS
■CONNECTION DIAGRAM
FG
1
4
9
12
5
8
Ch.1
INPUT
Ch.1
OUTPUT
9
12
Ch.2
OUTPUT
9
12
Ch.16
OUTPUT
1
4
5
8
Ch.16
INPUT
U(+)
V(–)
POWER
14
13
M2BS-16U0
EM-5005-U0 Rev.7 P. 2 / 3
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.8 N·m
■SOLDERLESS TERMINAL
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable.
Applicable wire size: 0.25 to 1.65 mm2(AWG 22 to 16)
Recommended manufacturer: Japan Solderless Terminal
MFG.Co.Ltd, Nichifu Co.,ltd
6 (.24) max
3.3 (.13) max
mm (inch)
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagrams of the in-
stallation base and the mounted signal conditioners.
2) Power input voltage
3) Installation & environments
LIGHTNING SURGE PROTECTION
We offer a series of lightning surge protector for protec-
tion against induced lightning surges. Please contact us to
choose appropriate models.
M2BS-16U0
EM-5005-U0 Rev.7 P. 3 / 3
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN

Other MG I/O System manuals

MG DLS-M1 User manual

MG

MG DLS-M1 User manual

MG Mini-M M2LMS User manual

MG

MG Mini-M M2LMS User manual

MG DS-824 User manual

MG

MG DS-824 User manual

MG R7F4HD-DA32B User manual

MG

MG R7F4HD-DA32B User manual

MG R7K4FML3-6-DC32B User manual

MG

MG R7K4FML3-6-DC32B User manual

MG R7F4HD-DAC32D User manual

MG

MG R7F4HD-DAC32D User manual

MG Devicenet R7F4HD-DA32A User manual

MG

MG Devicenet R7F4HD-DA32A User manual

MG DLC-C1 Series User manual

MG

MG DLC-C1 Series User manual

MG R6N-SS2 User manual

MG

MG R6N-SS2 User manual

MG R3-DA16 User manual

MG

MG R3-DA16 User manual

MG R9WTU-ED User manual

MG

MG R9WTU-ED User manual

MG R7F4DC-DC16B-H User manual

MG

MG R7F4DC-DC16B-H User manual

MG R7HL-YS4L User manual

MG

MG R7HL-YS4L User manual

MG M6DBS User manual

MG

MG M6DBS User manual

MG R7F4DC-DAC16C-H User manual

MG

MG R7F4DC-DAC16C-H User manual

MG R1M-GH User manual

MG

MG R1M-GH User manual

MG Devicenet R7F4DD-DC16A-C User manual

MG

MG Devicenet R7F4DD-DC16A-C User manual

MG R7C-RT4A User manual

MG

MG R7C-RT4A User manual

MG R7F4DC-DC8A-J User manual

MG

MG R7F4DC-DC8A-J User manual

MG R1M-J3 User manual

MG

MG R1M-J3 User manual

MG R30BS User manual

MG

MG R30BS User manual

MG R6N-SV2 User manual

MG

MG R6N-SV2 User manual

MG R7F4HEIP-DA16A User manual

MG

MG R7F4HEIP-DA16A User manual

MG Devicenet R7F4HD-DC32B User manual

MG

MG Devicenet R7F4HD-DC32B User manual

Popular I/O System manuals by other brands

M-system R7ML-DA16 instruction manual

M-system

M-system R7ML-DA16 instruction manual

Siemens SIMATIC ET 200iS manual

Siemens

Siemens SIMATIC ET 200iS manual

GE VersaPoint IC220ALG221 System manual

GE

GE VersaPoint IC220ALG221 System manual

CREVIS FnIO SSeries Quick start manual

CREVIS

CREVIS FnIO SSeries Quick start manual

Profire Energy PF2100 user manual

Profire Energy

Profire Energy PF2100 user manual

Crestron DMB-4K-CPU-128 Installation guides

Crestron

Crestron DMB-4K-CPU-128 Installation guides

Allen-Bradley Compact 5000 Series user manual

Allen-Bradley

Allen-Bradley Compact 5000 Series user manual

ICP DAS USA P8R8-DIO quick start guide

ICP DAS USA

ICP DAS USA P8R8-DIO quick start guide

Allen-Bradley ArmorBlock-LP 1792-IB16LP installation instructions

Allen-Bradley

Allen-Bradley ArmorBlock-LP 1792-IB16LP installation instructions

Extron electronics TLP VIM user guide

Extron electronics

Extron electronics TLP VIM user guide

National Instruments NI PXI-665 Series CALIBRATION PROCEDURE

National Instruments

National Instruments NI PXI-665 Series CALIBRATION PROCEDURE

ETAS ES930.1 user guide

ETAS

ETAS ES930.1 user guide

Measurement Computing USB-3103 user guide

Measurement Computing

Measurement Computing USB-3103 user guide

SeaLevel SeaRAQ 6510 user manual

SeaLevel

SeaLevel SeaRAQ 6510 user manual

EverFocus External I/O Box quick start guide

EverFocus

EverFocus External I/O Box quick start guide

WAGO I/O-SYSTEM 750 manual

WAGO

WAGO I/O-SYSTEM 750 manual

Advantech B+B SmartWorx Zlinx ZZ24D-NA-SR quick start guide

Advantech

Advantech B+B SmartWorx Zlinx ZZ24D-NA-SR quick start guide

Future Desion Controls FDC-VR18 quick start guide

Future Desion Controls

Future Desion Controls FDC-VR18 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.