INTRODUCTION
ARIA, Mii™ Single Electric Breast Pump, is a hospital-grade breast pump designed for comfort, power, and portability. Quality engineering makes ARIA a
safe option for moms through a 100% safe guard with no cross contamination. Equipped with Flutter Flex Vent™ soft cups made of 100% food-grade
silicone to allow longer and more comfortable pumps by avoiding damage to the nipple area. ARIA controls are capable of regulating milk production and
simulating baby’s feeding habits through suction strength, suction rate, and time settings. ARIA received its name because of its lightweight and quiet
functionality as a single hospital grade electric breast pump.
DETAILED PARTS LIST
ARIA ELECTRICAL BREAST PUMP :
A) Soft Cup Brace
B) Silicone Soft Cup
C) Valve Connection
D) Storage Container Connection
E) Valve +Flap
F) Soft Tube
G) Mii Storage Container
H) Bottle Stand
I) Main Connection
J) Main Machine
ASSEMBLY
Before first use, inspect the connection parts (such as Cups, Connectors, Valves + Flaps, and Main Machine) to make sure they are properly connected. Check
the tubing and storage container to be unobstructed, and whether the collector is clean.
Before pumping, use a hot and wet towel to first clean breast. Massage the breast and the root of nipple, relax body and alleviate the pain of engorged breasts,
if any.
Switch on the power, the LCD background light is on, the machine is standby.
When pumping normally, choose suction velocity at low speed (S grade), center the Cup with the Soft Cup Brace to the nipple; press against gently for suction.
You can select the appropriate suction velocity and intensity according to your needs and comfort.
If you experience problems such as the galactophore obstruction or sunken nipple, set the suction to max grade (H).
CONTROL PANEL
SUCTION VELOCITY SETTING
Switch on the power, the Main machine runs in low speed (S grade) automatically. Press the button “velocity +”/”velocity-” to adjust the suction speed. There
are 2 adjustable grades according to your comfort.
Press the button “intensity+”/ “intensity-“ to adjust the suction strength. There are 3 adjustable grades according to your comfort.
TIMER
During working time, the machine will stop suction temporarily after 20 mins. The machine is on standby. If you need restart the suction, just press the
“ON/OFF” button again.
Press the “ON/OFF” button to start or stop the suction.
CLEANING AND MAINTENANCE
All parts in direct contact with breast milk must be disassembled and cleaned before next usage: Cups, Valve, Storage Container, Tubing, etc. Do not immerse
the main machine water for cleaning. Do not microwave any parts.
Please clean all parts using detergent (for baby’s safety and best results, use Mii Organics
™
Dish Liquid). Sterilize all parts by placing in boiling water (all parts
must be disassembled well, and the boil time must not exceed 15 mins.).
Please keep cleaned parts separate without contacting the breast milk. Be sure to wash all tubing, bottles and bottle stand before each use. The main machine
can be cleaned by wet towel (use Mii Organics™ Multi-Purpose Cleaner for safest and best results).
After pumping, check to make sure there is no milk in the collector cup and soft tube. If there is milk in
the collector and soft tube, you should power off the machine at once. The collector and soft tube should
be only be reused after drying.
THE RIGHT TEAT FOR YOUR BABY
Flutter Flex Slow Flow Teat™
Flutter Flex Medium Flow Teat™
Flutter Flex Fast Flow Teat™
Flutter Flex Y-Cut Teat™
TIPS FOR MOMS
TROUBLESHOOTING
PROBLEM
REASON
SOLUTION
Weak Suction
Air leak of various connection parts
(Cup, Connector, Valve, Flap and
Collector)
Air pipeline of the Main machine is
blocked, for example fold & bend
of the Soft tube carelessly,
sundries in the Soft tube or Single-
connector
Check every connecting
parts,assemble again
Depurate & clean up
No Suction
Non-setting or improper setting of
the Flap, or the Flap is distorted or
damaged
Plastic parts are transmutation
damaged by poaching disinfection
cupboard, microwave oven,
pressured cooker
Install the flap
Replace new part
Can’t turn
on the machine
The Adapter with the wall socket or
the jack DC power in the Main
machine assembles incorrectly.
Use the wrong Adapter(output of the
original is 9V 1.5A, plug Ø2.1)
Connect again
Collocate rightly
Milk back-flow
Mothers with ample breast milk,
incorrectly choose the sucking
intensity grade “H” or “M”
Mothers with thick breast milk,
incorrectly choose the sucking
velocity high speed grade (F)
Non-joining the collector or too much
milk and haven’t cleaned out.
Too much globs in the Soft tube or
water pouring into the tube during
soak cleaning.
During sucking, breast milk exceeds
100ml in the Nursing bottle and
hasn’t exchanged the empty bottle.
Choose right grade
Use the collector
Don’t soak the soft tube
into water
Exchange the standby
soft tube
Exchange the empty
nursing bottle

Other manuals for ARIA

1

Other Mii Breast Pump manuals

Mii ARIA User manual

Mii

Mii ARIA User manual

Mii INNOVATUS User manual

Mii

Mii INNOVATUS User manual

Popular Breast Pump manuals by other brands

Tommee Tippee closer to nature instruction manual

Tommee Tippee

Tommee Tippee closer to nature instruction manual

Philips Avent SCF332 manual

Philips

Philips Avent SCF332 manual

medpack dr. Frei GM-1 user manual

medpack

medpack dr. Frei GM-1 user manual

imani i1 user manual

imani

imani i1 user manual

Spectra S9+ user manual

Spectra

Spectra S9+ user manual

Philips AVENT SCF334 manual

Philips AVENT

Philips AVENT SCF334 manual

Rumble Tuff Breeze Instructions & assembly

Rumble Tuff

Rumble Tuff Breeze Instructions & assembly

Philips AVENT SCF902 user manual

Philips AVENT

Philips AVENT SCF902 user manual

NUK jolie operating instructions

NUK

NUK jolie operating instructions

vivocare Smilky instruction manual

vivocare

vivocare Smilky instruction manual

Lionelo Twee Go user manual

Lionelo

Lionelo Twee Go user manual

Pumpables SuperGenie quick start guide

Pumpables

Pumpables SuperGenie quick start guide

Rumble Tuff Whisper Instructions & assembly

Rumble Tuff

Rumble Tuff Whisper Instructions & assembly

Apre 2 in 1 Electric Breast Pump user manual

Apre

Apre 2 in 1 Electric Breast Pump user manual

Medela Lactina Service instructions

Medela

Medela Lactina Service instructions

Microlife BC 300 Maxi 2 in 1 manual

Microlife

Microlife BC 300 Maxi 2 in 1 manual

Lionelo Twee user manual

Lionelo

Lionelo Twee user manual

Ardo Carum operating instructions

Ardo

Ardo Carum operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.