Mindman MP23C Series User manual

Zero & Unit setting button 31
42
QD PINOUT
PANEL DESCRIPTION / DIMENSIONS
3 ½ digit LED display
Display the measured
pressure value. each
setting mode and error
code.
PR-0064D 2021/10 Printing
300
We reserve the right to change the specification without prior notice.
Setting Button
kPa
kPa
MP23
MINDMAN INDUSTRIAL CO., LTD.
www.mindman.com.tw
MP-A1:Mounting bracket (BT-1)
MP-A2:Mounting bracket (BT-2)
MP-B1:Panel adapter (PA-A)
MP-C1:Panel adapter + Front protective lid (PA-B)
MP-D1:WIth M8, 4Pin female connector (M84R-W0085-2M)
For your safety, please read the following before using.
Do not use corrosive or flammable gas or liquid with this product.
Please use within the operating pressure range. Do not apply pressure beyond recommended maximum pressure, permanent damage to the pressure
sensor may occur.
Do not drop, hit or allow excessive shock. Even if switch body appears undamaged, internal components may be broken and can cause malfunction.
Turn power off before connecting wiring. Wrong wiring or short circuit will damage and / or cause malfunction.
Do not use in environment containing steam or oil vapor.
This product is not explosion-proof rated. Do not use in atmosphere containing flammable or explosive gases.
Wiring for pressure sensor should avoid power source line and high voltage line. If use in the same circuit, noise may cause malfunction.
1
2
3
4
5
6
7
Display pressure range
Withstand pressure
Fluid
Power supply voltage
Current consumption
Display
Indicator accuracy
-0.100 ~ 1.000 MPa
Filtered air, Non-corrosive/Non-Flammable gas
12 to 24V DC ±10%, Ripple (P-P) 10% or less
≦55mA
3½digit LED display (Red) (Sampling rate: 5 times/sec.)
±2% F.S. ±1 digit (ambient temperature: 25 ±3°C)
SPECIFICATIONS
-100.0 ~ 100.0 kPa
(Positive)(Compound)
Ambient temp. range
Ambient humidity range
Withstand voltage
Enclosure
Insulation resistance
Vibration
Shock
Temperature characteristic
Port size
Lead wire
Weight
Operation/Storage: 35 ~ 85% RH (No condensation)
1000V AC in 1-min (between case and lead wire)
IP40
50MΩ(at 500V DC, between case and lead wire)
980m/s2 (100G), 3 times each in direction of X, Y and Z
±2% F.S. of detected pressure (25°C) at temp. Range of 0~50°C
F1:Rc1/8"; F2:NPT1/8"; F3: G1/8"(BSPP)
Ø4 Oil-resistance cable ( PVC ) - 26 AWG ( 0.15 mm2) - 2 cores
Operation: 0 ~ 50°C, Storage: -20 ~ 60°C (No condensation or freezing)
Approx. 102g (with 2 meter lead wire), Approx. 68g (with M8, 4Pin male connector)
Total amplitude 1.5mm, 10Hz-55Hz-10Hz scan for 1 minute, two hours each direction of X, Y and Z
Environment
300 kPa 1.5 MPa
MP23C- - MP23P- -
kPa
MPa
kgf/cm2
bar
psi
mmHg
inHg
mmH2O
Set pressure
resolution
0.1
0.001
0.001
-
0.01
-
0.001
0.01
0.01
0.1
-
-
-
1
0.1
0.1
ORDERING INFORMATION
CIRCUIT WIRING DIAGRAM
DC(-)
(Blue)
DC(+)
(Brown)
DCDC
12-24V
Main circuit
*Pressure display only, no switch output function.
Pressure Range Cable Length/Connector
Pressure Port
C:Compound
(-100.0~100.0 kPa)
P:Positive
(-0.100~1.000 MPa)
Blank:With 2 meter cable
QD:With M8, 4Pin male connector
F1:Rc1/8”
F2:NPT1/8”
F3:G1/8"(BSPP)
Optional Parts
INSTALLATION
This product has two inlet pressure ports, select
the one most convenient for installation.
Please plug the unused inlet port with supplied
port plug. Use seal tape to prevent pressure leak.
1.
2.
Unit:mm
Bolt(screw)
MP23C-F1-
(1) Brown (+)
(2) Not used
(3) Blue (–)
(4) Not used

OPTIONAL PARTS DIMENSIONS
Unit:mm
Zero point setting
Measure mode
Unit setting
SETTING STEPS
UNIT SETTING MODE
Wait 3 seconds
MODEL:MP23P
Press (SET) button for more than 6 seconds and release. (Ignore ZERO POINT SETTING)
MPa kgf/cm2bar psi
(SET)
MODEL:MP23C
psikPa kgf/cm2bar mmHg
inHg mmH2O
(SET)
ERROR CODE INSTRUCTION
ZERO POINT SETTING
Under Measure Mode, press (SET) button for 2 ~ 6 second. Release when "00" is showing on display.
Digital Pressure Display
Mounting bracket MP-A1
Mounting bracket
Mounting bracket MP-A2
2
Measure mode
Measure mode
Unit setting
Measure mode
(SET) (SET) (SET) (SET) (SET) (SET) (SET) (SET) (SET)
(SET)
Panel mount adapter + Front protective lid
3
t≦4.5mm
36×36 ± 0.3mm
MP-A2
MP-A1
Applied
pressure error
System error
The applied pressure is excess the upper limit of
pressure setting.
Adjust the pressure within applied
pressure range.
Internal data error
Turn power off, and then restart.
If error condition remains, please return
to factory for inspection.
Residual
pressure error
Change input pressure to
ambient
pressure and perform zero reset again.
The applied pressure is excess the lower limit of
pressure setting.
Internal
system
error
Internal data error
Internal
system
error
Error Name
Error code
Error instruction Troubleshooting
During zero reset, ambient pressure is over
±3% F.S.
M8*1
M8 Female connector
Model : MP-D1
1
M4
M4
CHANGE PRESSURE UNIT TAG
When the pressure setting is not kPa or MPa, please remove the pressure unit tag and
place the selected tag on the indicated area of the faceplate to assure the pressure unit is
not misemployed and that setting error does not occur.
kPa
kgf/cm
2
mmHg
psi
MPa
From To
1 kPa
1 MPa
1 Pa
1000.000
1000000
1
98066.5
133.32
6895 6.895 0.006895 0.07031 51.7157 10.06895 2.036074 703.07
0.2953
295.2998
0.0002953 0.101968
101.9689
101968.9
0.010000
10
0.00001
0.145038
145.038
0.000145038
7.500616
7500.616
0.00750062
0.010197
10.197
0.000010197
0.001000
1
0.000001
1
1000
0.001
100000.0 100.0000 0.100000 1.01972 750.062 14.5038 129.52998
28.95979 10000.200.98066514.2233735.5591
0.0980665
98.0665
3386.388
9.80665
3.386388
0.00980
0.003386
-
0.034530
0.000099
25.40000
0.0735578
0.491141
0.00142
0.033863
0.000098
1
0.002895
345.324
1
0.039370 13.59540.00133320.01933610.00135950.0001330.13332
1 kgf/cm
2
1 mmHg
1 psi
1 bar
1 inHg
1 mmH
2
O
Pa kPa MPa
kgf/cm
2
mmHg psi bar inHg mmH2O
10196.89
mmH2O
inHg
bar
Panel adapter
Panel adapter
Front protective lid
When using a unit mmH2O, please multiply display value by 100.
When using a unit mmH2O, please multiply display value by 100.
NOTE :
NOTE :
www.mindman.com.tw
Front protective lidPanel adapter
MP23
This manual suits for next models
1
Table of contents