MindWare Technologies 50-2303-01 User manual

1
Product Manual
WWW.MINDWARETECH.COM
MindWare Mobile
Customer Support:
Email: support@mindwaretech.com
Phone: (888) 765-9735
Recorder
Manual
Copyright 2014 © by MindWare Technologies LTD. All Rights Reserved. 1

Customer Support:
Email: support@mindwaretech.com
Phone: (614) 626-4888
US Toll Free: (888) 765-9735
Fax: (614) 626-4915
MindWare Technologies LTD.
1020F Taylor Staon Rd.
Gahanna, OH 43230
2
WWW.MINDWARETECH.COM
Safety
Warning Regarding medical and clinical use of MindWare Technologies LTD products
MindWare Technologies LTD products are not designed with components and tesng
for a level of reliability suitable for use in treatment and diagnosis of humans or
as crical components in any life support systems whose failure to perform can
reasonably be expected to cause signicant injury to a human. Applicaons of
MindWare Technologies LTD products involving medical or clinical treatment can
create a potenal for death or bodily injury caused by product failure, or by errors
on the part of the user or applicaon designer. Any use or applicaon of MindWare
Technologies LTD products for or involving medical or clinical treatment must be
performed by properly trained and qualied medical personnel, and all tradional
medical safeguards, equipment, and procedures that are appropriate in the parcular
situaon to prevent serious injury or death should always connue to be used when
MindWare Technologies LTD products are being used. MindWare Technologies LTD
products are NOT intended to be a substute for any form of established process,
procedure, or equipment used to monitor or safeguard human health and safety in
medical or clinical treatment.

Customer Support:
Email: support@mindwaretech.com
Phone: (614) 626-4888
US Toll Free: (888) 765-9735
Fax: (614) 626-4915
MindWare Technologies LTD.
1020F Taylor Staon Rd.
Gahanna, OH 43230
3
Table of Contents
Quick Start 4
Introducon 5
Operang Modes................................................................................ 6
Device Overview 6
DC Charger Port and Charging LED...................................................... 6
SD Card Slot........................................................................................ 7
Display and Light Sensor...................................................................... 7
Keypad................................................................................................ 7
Input Channels.................................................................................... 8
Preparaon 11
Charging........................................................................................... 11
Lead Wires........................................................................................ 12
Inializaon....................................................................................... 12
Acquision 13
Conguraon.................................................................................... 13
Pre-Acquision................................................................................. 16
Acquision........................................................................................ 16
SengtheClock 18
FirmwareUpdates 18
Troubleshoong 19
CleaningInstruconsandOperangEnvironment 21
SupportContactInformaon22
Specicaons 23
Importantinformaon25

Customer Support:
Email: support@mindwaretech.com
Phone: (614) 626-4888
US Toll Free: (888) 765-9735
Fax: (614) 626-4915
MindWare Technologies LTD.
1020F Taylor Staon Rd.
Gahanna, OH 43230
4
Standalone Physiology Recording
1. Insert an SD Card
2. Attach signal leads to the Mobile Impedance unit
3. Power on with the Run ( ) button
4. The main screen summarizes the acquisition settings
a. See the full Local Mode documentation for details on the summary
5. Press A to enter Pre-Acquisition
a. Use the left and right arrows to verify signals
6. Press Bto start acquisition
a. Acquisition time will update in 5-second increments
b. Do not remove the SD card when the lock ( ) is displayed
7. Hold the left and right arrows to unlock the acquisition and press Ato exit
acquisition
8. Press Bto open the menu and select Power Off to turn off unit
Quick Start

Customer Support:
Email: support@mindwaretech.com
Phone: (614) 626-4888
US Toll Free: (888) 765-9735
Fax: (614) 626-4915
MindWare Technologies LTD.
1020F Taylor Staon Rd.
Gahanna, OH 43230
5
Introducon
Congratulations on your purchase of a MindWare Mobile Recorder unit. The
device you hold in your hand is the result of many years of development in
and use of the unit. There are sections throughout the text that are unique to the
warnings. These sections are indicated by the following symbols:
!
Important
Usage Tip
!
Warning
Operating
e MindWare Mobile Recorder is for independent, portable data collection to an SD
card. All 8 channels can be collected at 500 samples/second.

Customer Support:
Email: support@mindwaretech.com
Phone: (614) 626-4888
US Toll Free: (888) 765-9735
Fax: (614) 626-4915
MindWare Technologies LTD.
1020F Taylor Staon Rd.
Gahanna, OH 43230
6
Device Overview
DC Charger Port and Charging LED
e DC Charger Port interfaces with the supplied medical-grade DC power supply. It is
safety-isolated to allow charging the unit while it is in use.
!
To ensure safety, use only the provided medical-grade power supply
e charging LED turns on when the power supply is connected and the battery is charging.
It turns o when the battery is charged or power is lost. e LED blinks if the temperature is
too high, too low, or battery needs to be replaced.

Customer Support:
Email: support@mindwaretech.com
Phone: (614) 626-4888
US Toll Free: (888) 765-9735
Fax: (614) 626-4915
MindWare Technologies LTD.
1020F Taylor Staon Rd.
Gahanna, OH 43230
7
!
When the battery is low, the unit will beep every 10 seconds. This stops
when charging starts or after two minutes, when the unit stops any
acquisition and turns off.
SD Card Slot
e Mobile accepts full sized SD and SDHC cards in the SD card slot. It is designed
such that the SD card is ush with the case when inserted to prevent accidental removal
during acquisition. e depression in the middle of the slot allows the card to be inserted
or removed by pushing with a ngernail, pencil eraser, or other blunt object.
We recommend using SDHC cards for their increased performance.
Display and Light Sensor
In the interest of increasing battery life, the Mobile uses a low-power LCD screen with
the ambient light sensor to limit the backlight intensity during use. Any key press will
wake up the backlight for a short period of time.
Keypad
e keypad consists of two context buttons (A and B), four arrow buttons, and a Run (
) button. e arrow buttons are used for navigation and unlocking the unit during
acquisition. e button is the power button for the unit and also functions as an
OK or Select button, depending on what is on the screen. e context buttons change
function depending on text on the screen above them, or they act as event buttons
during acquisition. In many situations, the button duplicates the functionality of
context button B.
Use the context buttons during acquisition to mark events.

Customer Support:
Email: support@mindwaretech.com
Phone: (614) 626-4888
US Toll Free: (888) 765-9735
Fax: (614) 626-4915
MindWare Technologies LTD.
1020F Taylor Staon Rd.
Gahanna, OH 43230
8
Signal Label Color Channel Name Typical Use
BIO 1 Brown Bio 1 EKG, EMG, Respiration, HRV
BIO 2 Orange Bio 2 EKG, EMG, Respiration, HRV
CCS Red Z0and dZ/dt Cardiac Impedance
SNS White Z0and dZ/dt Cardiac Impedance
GSC Green GSC GSC, GSR, EDA
GND Black None Ground
Input Channels
e input channels are 1.5mm safety jacks that accept the supplied leads and connect to
electrodes on the subject. For ease of identication, the following are the inputs broken
down by names and colors:
EKG, EMG, EOG, Respiration, and Other General Voltage Signals
BIO1 and BIO2 are differential, DC-coupled voltage input channels with the following
gains and associated ranges and resolutions:
Gain Range (V) Resolution (nV)
1X +/- 2.4 286
2X +/- 1.2 143
3X +/- 0.8 95.4
4X +/- 0.6 71.5
6X +/- 0.4 47.7
8X +/- 0.3 35.8
12X +/- 0.2 23.8

Customer Support:
Email: support@mindwaretech.com
Phone: (614) 626-4888
US Toll Free: (888) 765-9735
Fax: (614) 626-4915
MindWare Technologies LTD.
1020F Taylor Staon Rd.
Gahanna, OH 43230
9
while respiration is measured with a sensor such as a piezoelectric respiration belt.
Various other sensors and devices with voltage outputs can be interfaced to these
channels as long as they are independently powered or produce their own voltage,
such as piezoelectric sensors.
Using the previous table, choose a gain with one range larger than the
expected limits of the signal being recorded to accommodate any variation
in the signal. When in doubt, run various test subjects at the highest range
(lowest gain) and adjust based on the range of data observed.
!
Individual channel ranges will vary slightly from unit-to-unit but the
calibration of each unit will correct for this variation to record accurate data.
!
Never connect other equipment to any of the Mobile inputs unless the output
of the equipment is also isolated for the safety of the subject. Safety isolated
inputs on other equipment does not guarantee that the outputs are also
isolated.
Cardiac Impedance
The Constant Current Source (CCS) and Sense (SNS) signals make up the cardiac
impedance measurement. The CCS lines are a constant current source at 500uA,
100kHz and the SNS lines measure the magnitude of the resulting 100kHz signal
received, which is recorded as the Z0channel. A derivative of this signal is performed
in hardware and recorded in the dZ/dt channel.
!
The dZ/dt channel is recorded as an inverted derivative to match the
convential representation of the signal.

Customer Support:
Email: support@mindwaretech.com
Phone: (614) 626-4888
US Toll Free: (888) 765-9735
Fax: (614) 626-4915
MindWare Technologies LTD.
1020F Taylor Staon Rd.
Gahanna, OH 43230
10
Galvanic Skin Conductance
The Galvanic Skin Conductance channel (GSC) is used to measure electrodermal
activity (EDA). It measures conductance by placing 0.5V between the electrodes and
that does not need a ground connection.
Ground
The ground (GND) connection is intended to keep the Mobile unit and the subject at
approximately the same DC potential to keep the signals within the input range of the
device (+/- 2.4V). The ground line needs to be attached to the subject at a location
with a minimum of muscle and possible movement.
Activity
There are three accelerometer channels, X, Y and Z, which are internal to the Mobile
unit. These can be used to assess activity levels, identify motion as the source of noise
in the other channels, and can estimate the posture of the subject.

Customer Support:
Email: support@mindwaretech.com
Phone: (614) 626-4888
US Toll Free: (888) 765-9735
Fax: (614) 626-4915
MindWare Technologies LTD.
1020F Taylor Staon Rd.
Gahanna, OH 43230
11
Proper planning will make your Mobile experience go smoothly. Before an acquisition,
fully charge the Mobile unit, check for dry or expired electrodes, and check for broken
leads.
Charging
To charge the unit, plug the supplied charger into
an outlet and into the Mobile. A Green light by
the charging port will illuminate while the unit is
charging. A full charge will take approximately four
hours from a low battery state. If the unit has been unused for a long time, it may need
to charge for an extended period before turning on. In this case, the clock may need to
be reset. See the section on Setting the Clock for instructions.
While the unit is off and charging, a battery is displayed on the screen with:
o A lightning bolt and charge percentage during charging
o A checkmark when fully charged
When the unit is powered on, most screens display a battery charge indicator
in the top left corner
The battery charge level indicator and percentage are only an approximation
of the charge of the battery. The unit begins beeping when the battery is low,
then stops acquisition after two minutes to preserve data before shutting down.
International plug kits are available for the charger. Contact a sales
representative to order one.
!
Note: The battery will continue to trickle charge even after the charge light
goes out and the unit indicates that it is charged. To maximize your runtime,
allow the unit to continue to charge in this state for a few hours before
disconnecting.
Preparaon
ChargingChargeComplete

Customer Support:
Email: support@mindwaretech.com
Phone: (614) 626-4888
US Toll Free: (888) 765-9735
Fax: (614) 626-4915
MindWare Technologies LTD.
1020F Taylor Staon Rd.
Gahanna, OH 43230
12
Lead Wires
Unfortunately, durable leads are uncomfortable to wear and comfortable leads are
fragile. The leads supplied with your Mobile unit are designed with a balance of
durability and comfort. When treated well, they can last a long time:
Never bend the leads sharply, especially near the connectors at either end.
electrode.
Initialization
To power on the Mobile unit, press the button. The boot procedure takes a
moment and then you are presented with the home screen.

Customer Support:
Email: support@mindwaretech.com
Phone: (614) 626-4888
US Toll Free: (888) 765-9735
Fax: (614) 626-4915
MindWare Technologies LTD.
1020F Taylor Staon Rd.
Gahanna, OH 43230
13
Acquision
Configuration
home screen, as seen below.
This screen is a summary of relevant information on the acquisition
to verify setup before proceeding. The following is a rundown of the key
elements.
Charge Indicator
The charge indicator displays the approximate charge level of the battery.
It is an estimate and not a substitute for fully charging the unit before every
acquisition.
Current Time
This shows the current time. This clock is used to timestamp every
acquisition and can be used for a rough synchronization of multiple units
working in local mode.
SD Card Status
The icon in this location indicates the status of the SD card. A closed
padlock symbol means that the SD card is being accessed. Do not remove
the SD card when this symbol is displayed. An open padlock indicates

Customer Support:
Email: support@mindwaretech.com
Phone: (614) 626-4888
US Toll Free: (888) 765-9735
Fax: (614) 626-4915
MindWare Technologies LTD.
1020F Taylor Staon Rd.
Gahanna, OH 43230
14
only locked when starting or immediately after an SD card is inserted.
The X symbol means that there is no card inserted or there is a problem with the
inserted card. See the troubleshooting section for information on addressing SD
card issues.
Time Estimate
When an SD card is inserted and initialized, the unit displays an estimate of the
recording time available on that card. This is a worst-case estimate based on all
channels enabled and some overhead for events.
!
SD cards, which corresponds to approximately 48 hours of data collection
with all channels enabled. The unit will not last that long without charging
during the acquisition.
Acquisition ID
characters and the acquisition count in the last three digits. The acquisition count
will automatically increment to the next number after each acquisition. Both of
Channel Configurations
This area summarizes the status of all of the channels. To the left of each channel
indicating an enabled channel or an empty circle
indicating a disabled channel. The two Bio channels have gain settings to the right
of their names. Note that the gain values are simply indicators of the channel
10) to understand what those gains mean in terms of resolution and range.
Pre-Acq
the next section.
Menu
Context button B enters the main menu.

Customer Support:
Email: support@mindwaretech.com
Phone: (614) 626-4888
US Toll Free: (888) 765-9735
Fax: (614) 626-4915
MindWare Technologies LTD.
1020F Taylor Staon Rd.
Gahanna, OH 43230
15
Configuration Menu Map:
Acq Settings
Acquisition ID
and the last three numbers automatically increment for each
acquisition.
CH1-Bio
-On/Off
-Gain & Range
CH2-Bio
-On/Off
-Gain & Range
CH3-Z0
-On/Off
CH4-dZ/dt
-On/Off
CH5-GSC
-On/Off
Accelerometer – This controls all three axes of the accelerometer
-On/Off
System Settings – These are unit-level settings
Date & Time
About
Power Off – Power off the unit

Customer Support:
Email: support@mindwaretech.com
Phone: (614) 626-4888
US Toll Free: (888) 765-9735
Fax: (614) 626-4915
MindWare Technologies LTD.
1020F Taylor Staon Rd.
Gahanna, OH 43230
16
Pre-Acquisition
The purpose of the pre-acquisition state is to allow you to
preview the signal morphology to verify that electrodes
are placed properly and hooked up correctly. The Left and
Right buttons allow you to cycle through each of the enabled
channels. After verifying signals, Context Button B will start the
acquisition or Context Button A
!
Due to the data processing and frequent screen
updates, the Pre-Acquisition state drains the battery
verifying signals if the acquisition is not starting soon.
Acquisition
In this state, data is being recorded to the SD card. The SD card is locked the entire
time and should not be removed until acquisition is ended. Context Button Aand
Context Button B
!
Do not be alarmed if it appears that the timer is not
counting up. It is designed to only update every 5 seconds
to maximize runtime.
Unlocking Acquisition
Acquisition is unlocked by holding the left and right arrow
buttons at the same time. This puts the acquisition into a mode
similar to pre-acquisition where signals can be viewed. Use the left and right arrows
to cycle through the different signals. This is useful for checking on electrodes
between phases of a study.
The acquisition will stay unlocked for 10 seconds after any key press and then
automatically return to the locked state. No events can be recorded while unlocked.

Customer Support:
Email: support@mindwaretech.com
Phone: (614) 626-4888
US Toll Free: (888) 765-9735
Fax: (614) 626-4915
MindWare Technologies LTD.
1020F Taylor Staon Rd.
Gahanna, OH 43230
17
Ending Acquisition
To
!
Note that the Mobile stores data in only the raw MWX format. All of the
opened. The MWI builder is in the Tools menu of most applications.

Customer Support:
Email: support@mindwaretech.com
Phone: (614) 626-4888
US Toll Free: (888) 765-9735
Fax: (614) 626-4915
MindWare Technologies LTD.
1020F Taylor Staon Rd.
Gahanna, OH 43230
18
Seng the Clock
The clock is set by selecting the Date & Time entry in the System Settings menu
Left and Right Arrows and use the Up and Down arrows to change the entries.
appropriate entry from AM, PM, or 24Hr.
The new time and date is not saved until the Save button is selected, so to acheive
Save at that time.
Firmware Updates
issues, improve performance, and add features. Apply updates with the following
procedure:
2. Insert the SD card in to the Mobile and attach the charger
3. Power on the Mobile using the button
4. While the MindWare logo is scrolling on the screen, press and hold both the
left and right arrow buttons
8. Wait while the update is performed. It will take a few minutes and may not
indicate any progress on the screen

Customer Support:
Email: support@mindwaretech.com
Phone: (614) 626-4888
US Toll Free: (888) 765-9735
Fax: (614) 626-4915
MindWare Technologies LTD.
1020F Taylor Staon Rd.
Gahanna, OH 43230
19
Troubleshoong
Help! My SD Card is not working!
computer to run a disk check to repair any corruption
o Check the lock status before removing the SD card and only remove if the
display shows an open lock
o The card is only locked for a brief time after it is initially inserted, at the start
of pre-acquisition, and during acquisition.
read it back
o SD cards can become damaged through misuse or premature failure
o Replace failed cards with only SDHC cards
I am having trouble inserting or removing my SD Card.
o Use the eraser end of a pencil or another blunt object in the slot indentation
to insert or eject the card
insertion or removal
My Mobile is beeping at me!
o Short beeps approximately 10 seconds apart mean that the battery is low and
the unit will stop acquisition and power down soon
o Connect a charger to continue acquisition
damaged Mobile
o Contact customer support

Customer Support:
Email: support@mindwaretech.com
Phone: (614) 626-4888
US Toll Free: (888) 765-9735
Fax: (614) 626-4915
MindWare Technologies LTD.
1020F Taylor Staon Rd.
Gahanna, OH 43230
20
The green charging light is blinking
The battery is too warm to safely charge
o The unit has paused charging until it has cooled down enough to continue
The charge light will not turn on
The Mobile unit may be fully charged
o The light only illuminates during charging
o Contact customer support
My Mobile will not turn on
The battery may be low or deeply discharged
o Connect the charger overnight
- If the battery becomes deeply discharged, the unit will slowly charge
to prevent damage to the battery. Once it has reached enough charge
to power on, the normal charging screen will display and it will reach a
full charge in approximately four hours from that point
o Remove the charger and hold the Run Button ( ) for 12 seconds to force the
unit to shut down
o Attach the charger and the unit should display the charging screen
My concern is not listed here
Table of contents
Popular Voice Recorder manuals by other brands

Yamaha
Yamaha PocketrakCX - POCKETRAK CX 2 GB Digital... Reference manual

Sony
Sony Memory Stick ICD-MS515 operating instructions

Olympus
Olympus DS-9500 Administration guide

Olympus
Olympus DM 620 Detailed instructions

Broadcast Tools
Broadcast Tools tiny TOOLS VAD - 2 Plus Installation and operation manual

LogTag Recorders
LogTag Recorders USRIC-4 Product user guide