Mission Critical xantrex Freedom SW 3012 User manual

FREEDOM SW 3012
FREEDOM SW 3012
CLEARFAULT
RESET
INVERTER
ENABLE
INVERTER
ENABLED ACIN FAULT
GEN
SUPPORT
CHARGING WARNING
FREEDOM SW 3012
FREEDOM SW 3012
CLEARFAULT
RESET
INVERTER
ENABLE
INVERTER
ENABLED ACIN FAULT
GEN
SUPPORT
CHARGING WARNING
Freedom SW-RVC Inverter/Charger
RV-C DGN Guide
Product ModelNumber
815-3012-02

2 Freedom SW-RVC DGN Reference Guide
Copyright © 2022 Xantrex LLC. All Rights Reserved. All trademarks are owned by Xantrex LLC and its affiliates.
Document Number:976-0452-01-01 Rev B Date: September 2022
Product Name and Part Number
Freedom SW-RVC (815-3012-02)
Contact Information
Telephone: (Toll Free USA/Canada) +1 800 670 0707 / (Outside USA/Canada) +1 408 987 6030
Email: customerservice@xantrex.com,
http://www.xantrex.com/power-products-support/
Web: http://www.xantrex.com/

ABOUT THIS GUIDE
Purpose
The purpose of this RV-C DGN RV-C DGN Guide is to provide a
list of supported Data Group Numbers (DGN) for the Freedom
SW-RVC. The list also includes events (for example, faults and
warnings), and proprietary messages.
Scope
The reference provides the DGN list including events (for
example, faults and warnings), and proprietary messages
available for the inverter/charger. It does not provide installation
and operational information and troubleshooting guidelines.
Audience
The reference is intended for programmers of RV-C compatible
devices which have to communicate with the Freedom SW-RVC
Inverter/Charger.
Related Information
You can find more information about Xantrex products and
services at http://www.xantrex.com/.
IMPORTANT:The latest RV-C standard is available at.
http://www.rv-c.com/forum/8.
976-0452-01-01 3

4 976-0452-01-01
CONTENTS
Supported DGNs 5
Introduction 5
DC Source DGNs 6
Inverter DGNs 8
Charger DGNs 15
Diagnostic DGNs 25
Faults and Warnings 29
Diagnostics Message (DM_RV) in RV-C Specs 30
Proprietary messages 33
Introduction 33
Proprietary DGN General Framework 34
DGN Messages 35
Examples of Proprietary_Message_Request 43

Introduction
976-0452-01-01 5
1 SUPPORTED DGNS
Introduction 5
DC Source DGNs 6
Inverter DGNs 8
Charger DGNs 15
Diagnostic DGNs 25
Introduction
This section provides some general information on supported RV-
C Data Group Numbers (DGNs) by the Freedom SW-RVC.
Bus Speed: 250kbps
Source Address: Default to 0x42, support for dynamic address
claiming according to "Section 3.3.2 Source Address Claiming" of
the RV-C standard.

DC Source DGNs
6 Freedom SW-RVC DGN Reference Guide
DC Source DGNs
Abbreviations: HEX = hexadecimal; ms = millisecond; RV-C = Recreational Vehicle Controller Area Network (CAN)
RV-C DGN Name Broadcast List and Interval (ms) DGN Hex Parameter Freedom SW RV-C Range
x= not implemented
6.5.2 DC Source Status 1
DC_SOURCE_STATUS_1
500 1FFFD Instance See RV-C specs
Device Priority
DC Voltage
DC Current
6.5.3 DC Source Status 2
DC_SOURCE_STATUS_2
500 1FFFC Instance See RV-C specs
Device Priority
Source Temperature
State of Charge
x Time Remaining
6.5.4 DC Source Status 3
DC_SOURCE_STATUS_3
N/A (not broadcasted, responds to
query)
1FFFB Instance Not broadcasted, just sent upon
request.
Sent with no data on all fields.
Device Priority
x State of Health
xCapacity
Remaining
x Relative Capacity
x AC RMS Ripple

DC Source DGNs
976-0452-01-01 7
RV-C DGN Name Broadcast List and Interval (ms) DGN Hex Parameter Freedom SW RV-C Range
x= not implemented
6.5.5 DC Source Status 4
DC_SOURCE_STATUS_4
5000 1FEC9 Instance See RV-C specs
Device Priority
x Desired charge state
x Desired DC voltage
x Desired DC current
Battery Type

Inverter DGNs
8 Freedom SW-RVC DGN Reference Guide
Inverter DGNs
RV-C DN Name Broadcast List and Interval (ms) DGN Hex Parameter Freedom SW RV-C Range
x= not implemented
6.19.3 AC Output Page1
INVERTER_AC_STATUS_1
100 1FFD7 Instance Instance (See Note 1
above)
See RV-C specs
RMS Voltage
RMS Current
Frequency
x Fault - open ground
x Fault - open neutral
x Fault - reverse polarity
x Fault - ground current
6.19.4 AC Output Page 2
INVERTER_AC_STATUS_2
N/A (not broadcasted, responds to
query)
1FFD6 Instance Instance (See
Note 1 above)
Not broadcasted, just sent
upon request.
Sent with no data on all
fields.
x Peak Voltage
x Peak Current
x Ground Current
x Capacity

Inverter DGNs
976-0452-01-01 9
RV-C DN Name Broadcast List and Interval (ms) DGN Hex Parameter Freedom SW RV-C Range
x= not implemented
6.19.5 AC Output Page 3
INVERTER_AC_STATUS_3
100 1FFD5 Instance Instance (See Note 1 above) See RV-C specs
Waveform
Phase Status
Real Power
Reactive Power
x Harmonic Distortion
x Complementary Leg
6.19.6 AC Output Page 4
INVERTER_AC_STATUS_4
100 1FF8F Instance Instance (See Note 1 above) See RV-C specs
Voltage Fault
x Fault - surge protection
x Fault - high frequency
x Fault - low frequency
x Bypass mode active
Qualification Status

Inverter DGNs
10 Freedom SW-RVC DGN Reference Guide
RV-C DN Name Broadcast List and Interval (ms) DGN Hex Parameter Freedom SW RV-C Range
x= not implemented
6.19.8 Inverter Status
INVERTER_STATUS
500 1FFD4 Status See RV-C specs
Battery Temp. Sensor Present
x Load Sense Enabled
x Inverter Enable
x Pass-Through Enable
x Generator Support Enable
6.19.9 Inverter Command
INVERTER_COMMAND
N/A 1FFD3 Instance See RV-C specs
Inverter Enable
Load Sense Enable
x Pass-Through Enable
x Generator Support Enable
x Reserved
x Inverter Enable on Startup
x Load Sense Enable on Startup
x AC Pass-Through Enable on Startup
x Generator support enable on startup

Inverter DGNs
976-0452-01-01 11
RV-C DN Name Broadcast List and Interval (ms) DGN Hex Parameter Freedom SW RV-C Range
x= not implemented
6.19.10 Inverter Configuration Status 1
INVERTER_CONFIGURATION_
STATUS_1
On Change 1FFD2 Instance See RV-C specs
Load Sense Power Threshold
Load Sense Interval
DC Source Shutdown Voltage - Min
xInverter Enable on Startup
x Load Sense Enable on Startup
x AC Pass-Through Enable on Startup
x Generator support enable on startup
6.19.11 Inverter Configuration Status 2
INVERTER_CONFIGURATION_
STATUS_2
On Change 1FFD1 Instance See RV-C specs
Load Sense Power Threshold
DC Source Shutdown Voltage - Max
DC Source Warning Voltage - Min
DC Source Warning Voltage - Max

Inverter DGNs
12 Freedom SW-RVC DGN Reference Guide
RV-C DN Name Broadcast List and Interval (ms) DGN Hex Parameter Freedom SW RV-C Range
x= not implemented
6.19.12 Inverter Configuration Status 2
INVERTER_CONFIGURATION_
STATUS_3
On Change 1FECE Instance See RV-C
specs
DC Source shutdown delay
Stack Mode
xDC Source Shutdown Recovery
Level
x Generator Support Engage Current
6.19.14 Inverter Configuration
Command 1
INVERTER_CONFIGURATION_
COMMAND_1
N/A 1FFD0 Instance See RV-C specs
Load Sense Power Threshold 25W to 250W
Load Sense Interval 1sec to 25sec
DC Source Shutdown Voltage (Min) 10.0V to 12.0V
6.19.15 Inverter Configuration
Command 2
INVERTER_CONFIGURATION_
COMMAND_2
N/A 1FFCF Instance See RV-C specs
DC Source
Shutdown
Voltage (Max)
14.5V to 17.0V
DC Source
Warning
Voltage (Min)
DC Source Shutdown Voltage (Min)" -
2.000V to "DC Source Shutdown
Voltage (Min)
DC Source
Warning
Voltage (Max)
DC Source Shutdown Voltage (Max)"
-3.000V to "DC Source Shutdown
Voltage (Max)

Inverter DGNs
976-0452-01-01 13
RV-C DN Name Broadcast List and Interval (ms) DGN Hex Parameter Freedom SW RV-C Range
x= not implemented
6.19.16 Inverter Configuration
Command 3
INVERTER_CONFIGURATION_
COMMAND_3
N/A 1FECD Instance See RV-C specs
DC Source shutdown delay 0sec to 600sec
Stack Mode
1- Master
2-Slave
3-Line 2 Master
xDC Source Shutdown Recovery
Level
See RV-C specs
x Generator Support Engage Current
6.19.18 Inverter Statistics
INVERTER_STATISTIC_STATUS
N/A 1FFCE Instance N/A
x Number of DC Under Voltage Detections
x Number of Inverter AC Output Over-Loads
x Number of Times Load Sense Engaged
x Lowest DC Voltage
x Highest DC Voltage
x Lowest AC Input Voltage
x Highest AC Input Voltage
x Lowest AC Output Voltage
x Highest AC Output Voltage
x Reserved

Inverter DGNs
14 Freedom SW-RVC DGN Reference Guide
RV-C DN Name Broadcast List and Interval (ms) DGN Hex Parameter Freedom SW RV-C Range
x= not implemented
6.19.22 Inverter DC Status
INVERTER_DC_STATUS
5000 1FEE8 Instance See RV-C specs
DC Voltage
DC Amperage
xDC Source Shutdown Recovery
Level
6.19.23 Inverter Temperature Status
INVERTER_TEMPERATURE_
STATUS
500 1FEBD Instance See RV-C specs
FET Temperature
Transformer Temperature

Charger DGNs
976-0452-01-01 15
Charger DGNs
RV-C DN Name Broadcast List and Interval (ms) DGN Hex Parameter Freedom SW RV-C Range
x= not implemented
6.20.3 AC Input Page 1
CHARGER_AC_STATUS_1
5000 1FFCA Instance Instance (See Note 1
above)
See RV-C specs
RMS Voltage
RMS Current
x Fault - open ground
x Fault - open neutral
x Fault - reverse polarity
xFault - ground current
6.20.4 AC Input Page 2
CHARGER_AC_STATUS_2
N/A 1FFC9 Instance Instance (See Note 1 above) N/A
x Peak Voltage
x Peak Current
x Capacity

Charger DGNs
16 Freedom SW-RVC DGN Reference Guide
RV-C DN Name Broadcast List and Interval (ms) DGN Hex Parameter Freedom SW RV-C Range
x= not implemented
6.20.5 AC Input Page 3
CHARGER_AC_STATUS_3
5000 1FFC8 Instance Instance (See Note 1
above)
See RV-C specs
x Waveform
x Phase Status
Real Power
Reactive Power
x Harmonic Distortion
x Complementary Leg
6.20.6 AC Input Page 4
CHARGER_AC_STATUS_4
5000 1FF8A Instance Instance (See Note 1
above)
See RV-C specs
x Voltage Fault
x Fault - surge protection
x Fault - high frequency
x Fault - low frequency
x Bypass Mode Active
Qualification Status

Charger DGNs
976-0452-01-01 17
RV-C DN Name Broadcast List and Interval (ms) DGN Hex Parameter Freedom SW RV-C Range
x= not implemented
6.20.8 Charger Status
CHARGER_STATUS
5000 1FFC7 Instance See RV-C specs
Charge Voltage
Charge Current
Charge Current Percent of Max
Operating State
Default State on Power-Up
Auto Recharge Enabled
Force Charge
6.20.10 Charger Configuration
CHARGER_CONFIGURATION_
STATUS
N/A 1FFC6 Instance See RV-C specs
Charger Mode
Battery Sensor Present
x Charger Installation Line
BatteryType
Battery Bank Size
Maximum Charging Current

Charger DGNs
18 Freedom SW-RVC DGN Reference Guide
RV-C DN Name Broadcast List and Interval (ms) DGN Hex Parameter Freedom SW RV-C Range
x= not implemented
6.20.11 Charger Command
CHARGER_COMMAND
N/A 1FFC5 Instance See RV-C specs
Status
x Default State on Power-Up
Auto Recharge Enabled
Force Charge
0- Cancel forcing
1 - Force charge to bulk
2 - Force charge to float
14 - No change
15 - Undefined

Charger DGNs
976-0452-01-01 19
RV-C DN Name Broadcast List and Interval (ms) DGN Hex Parameter Freedom SW RV-C Range
x= not implemented
6.20.12 Charger Configuration
Command
CHARGER_CONFIGURATION_
COMMAND
N/A 1FFC5 Instance See RV-C specs
Charging Algorithm 2-3-Stage
3-2-Stage
Charger Mode See RV-C specs
x Battery Sensor Present See RV-C specs
x Charger Installationline
Battery Bank Size 50Ah to 2000Ah
Battery Type 0 - Flooded
1 - Gel
2 - AGM
13 - Custom1
15 - Invalid
x Reserved See RV-C specs
x Maximum Charging Current

Charger DGNs
20 Freedom SW-RVC DGN Reference Guide
RV-C DN Name Broadcast List and Interval (ms) DGN Hex Parameter Freedom SW RV-C Range
x= not implemented
6.20.13 Charger Configuration Status 2
CHARGER_CONFIGURATION_
STATUS_2
On change 1FF96 Instance See RV-C
specs
Max Charge Current as a Percentage
x Charge Rate Limit as Percent of Bank
Size
Shore Breaker Size
Default Battery Temperature
Recharge Voltage
6.20.14 Charger Configuration
Command 2
CHARGER_CONFIGURATION_
COMMAND_2
N/A 1FF95 Instance See RV-C
specs
Max Charge Current as a Percentage 10-100%
x Charge Rate Limit as Percent of Bank
Size
See RV-C
specs
Shore Breaker Size 5-30A
Default Battery Temperature 10 - Cold
25 - Warm
40 -Hot
Recharge Voltage 11.0V to 13.5V