3/ 4
window for 5 seconds, if received OPU confirmation in this
time, the buzzer immediately stop chirping, indicator lights,
RF signal no longer sends, the recovery detection after 3
minutes, otherwise, Send a RF alarm signal each 15
seconds, buzzer continued to sing, indicator light blinks
continuously.
4. In alarm process, push cancel buttom, the buzzer
immediately stop singing, the lights go out, RF signal is no
longer sent
Emergency button triggered
alarm
1ˊEmergency Alarm: long press the button about 3S, the
buzzer sounded, indicating LED flashing, DUT issued
emergency alarm signal; if received OPU confirmation,
alarm stop, at the same time buzzer stop singing. LED
Lights out, otherwise every 15s DUT send an alarm,
buzzer continual tweets, LED flashes red light. if people
cancel the alarm, at this time the emergency alarm actived
again, the DUT would delay 30s, then transmission alarm,
the buzzer would beep, and LED would flash.
2. Cancel Alarm: when the buzzer sounded, press the button
one times, the buzzer stopped ringing, the DUT canceled
transmission signal.
3. Sleep Mode: Sleep at any time by pressing the button, the
indicator light goes out, into the sleep state.
4. Power off: continuous press button 3 times within 5S, the 4
time press the button until the indicator light green light lit
up, then release the button. The green indicator light
flashes continuously for 4 times, DUT would enter the
shutdown mode. DUT would boot only by charging mode
(for the customer is not recommended to use the function)
LED Indicator
Charging: Red LED keep lighting
Charge Finish: Green LED keep lighting
Standard By: Green LED flashing
Alarm: Red LED flashing
Low power : red and green led flash (yellow )
Communication
RF Frequency
Modulation ASK
Antenna Internal Antenna
Transmit Power ≥TBD ( use A6 fixture )
RF Range TX 50m indoor (Line of sight, LOS)
433.92MHz