1 system introduction
If elders fall and can’t get up or is unable to push emergency button, the fall
detector will automatically send a signal within 10 seconds. The emergency
contacts will know that you have fallen.
If elders fall and stand up in less than 10 seconds, a emergency signal will not be
automatically generated. This allows you to recover from falls that are not serious
enough to require help. However, if you think you need assistance, you can push
emergency button any time you need help.
2 Specification
System
Processor/MCU/RF TI MSP430
Sensor STM LIS3DSH Accelerometer
Operating Voltage 3.7V-4.2V
Power Source Li-battery 70mAh
Powered Port Micro USB (Input 5VDC)
Power Consumption 3 days (Triggered twice a day )
Battery Low Level Indicator Low battery indicating if voltage <= 3.7V
Low Battery Alarm Mode Low battery only alarms when another alarm triggered or
heartbeat
Heart Beats Duration Per 12hrs
Operating Environment Working Temp: 0ɗ~50ɗ
Humidity: 5%~80%RH non-condensing
Storage Environment Temperature: -20ć~60ć
Humidity: 5%~85% RH
Safety Regulation FCC/CE
Environmental Standard RoHS, REACH
Function
Detection Type Fall detecor
triggered alarm
Alarm process:
1. When the human body is exposed to the ground, received
violent impact, then the body keeps still for a while, the
DUT star to alarm. The judgment condition of falling:
weight loss - violent impact - quiet.
2. If canceled the alarm within 15 seconds, the buzzer
stopped singing, the lights go out, otherwise 15 seconds
alarm signal is issued, the buzzer continued to ring,
indicating lights flashing
3. After RF warning signal issued, DUT will open a receive

3/ 4
window for 5 seconds, if received OPU confirmation in this
time, the buzzer immediately stop chirping, indicator lights,
RF signal no longer sends, the recovery detection after 3
minutes, otherwise, Send a RF alarm signal each 15
seconds, buzzer continued to sing, indicator light blinks
continuously.
4. In alarm process, push cancel buttom, the buzzer
immediately stop singing, the lights go out, RF signal is no
longer sent
Emergency button triggered
alarm
1ˊEmergency Alarm: long press the button about 3S, the
buzzer sounded, indicating LED flashing, DUT issued
emergency alarm signal; if received OPU confirmation,
alarm stop, at the same time buzzer stop singing. LED
Lights out, otherwise every 15s DUT send an alarm,
buzzer continual tweets, LED flashes red light. if people
cancel the alarm, at this time the emergency alarm actived
again, the DUT would delay 30s, then transmission alarm,
the buzzer would beep, and LED would flash.
2. Cancel Alarm: when the buzzer sounded, press the button
one times, the buzzer stopped ringing, the DUT canceled
transmission signal.
3. Sleep Mode: Sleep at any time by pressing the button, the
indicator light goes out, into the sleep state.
4. Power off: continuous press button 3 times within 5S, the 4
time press the button until the indicator light green light lit
up, then release the button. The green indicator light
flashes continuously for 4 times, DUT would enter the
shutdown mode. DUT would boot only by charging mode
(for the customer is not recommended to use the function)
LED Indicator
Charging: Red LED keep lighting
Charge Finish: Green LED keep lighting
Standard By: Green LED flashing
Alarm: Red LED flashing
Low power : red and green led flash (yellow )
Communication
RF Frequency
Modulation ASK
Antenna Internal Antenna
Transmit Power ≥TBD ( use A6 fixture )
RF Range TX 50m indoor (Line of sight, LOS)
433.92MHz

4/ 4
3 Operating instructions
1. Wear the fall detector and stand the right place where you need to detect.
2. Simulated falling down, wait for the fall detector active.
3. Push the button for 3 seconds to enter emergency Alarm mode.
4. When battery is low power, fall detector would send alarm. Please recharge as soon
as possible.
FCC Statement
This device compiles with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
a) This device may not cause harmful interference
b) This device must accept any interference received, including interference that may
cause undesired operation.
Warming! This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses and radiate radio
frequency energy, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
--Reorient or relocate the receiving antenna.
--Increase the separation between the equipment and receiver.
--Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
--Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
Table of contents
Popular Accessories manuals by other brands

Philips
Philips CRP483 brochure

MTS Sensors
MTS Sensors Temposonics MH-Series installation manual

STEINEL PROFESSIONAL
STEINEL PROFESSIONAL Control PRO LiveLink Series operating instructions

AirSense
AirSense 315 quick start guide

NeoVictory
NeoVictory BonSayOn W303 product manual

NKE
NKE ULTRASONIC SPEEDO USER GUIDE and INSTALLATION GUIDE

Masimo
Masimo RD SET manual

Honeywell
Honeywell 205273AA installation instructions

witeg Labortechnik GmbH
witeg Labortechnik GmbH WIS-10 operating manual

Vetra
Vetra ViewSplice VIP- 884-V Series User instruction

TREND
TREND HT/S installation instructions

Dahua Technology
Dahua Technology Wireless Door Detector Plus user manual