Mottura 99.724 Quick start guide

12/24 V
RELAY MODULE
99.724
INSTALLATION/USE INSTRUCTIONS
All connections MUST
be made with the electri-
cal supply switched o
and the batteries discon-
nected.
GENERAL WARNINGS
This manual is intended for technically qualied and trained installers.
Mottura Serrature di Sicurezza S.p.A. thanks you for choosing this product and reminds you:
- Read the instructions very carefully before installing or doing any maintenance on the device.
- All assembly and connection procedures must be done according to Rules of Good Engineering as well as in conformity to law.
- DO NOT install this device in explosive environments or atmospheres or in the presence of ammable fumes/gases.
- DO NOT install this device on a door with risk of contact with water or atmospheric agents unless the door is adequately protected.
- Always disconnect the power supply and isolate all live parts before installing or doing any maintenance on the device. Take all possible precautions
to eliminate the risk of electrical shock when doing the installation and/or maintenance procedures described in this manual.
- The installer must give these instructions and all maintenance instructions to the user.
- Keep these instructions for future use and attach the sales receipt to validate the warranty.
- In case of problems, contact your authorized dealer only.
Mottura Serrature di Sicurezza S.p.A. may change the characteristics of the products described in these instructions at any time and without notice.
WARRANTY TERMS
This device has been inspected by Mottura Serrature di Sicurezza S.p.A. and is guaranteed against all manufacturing defects for the period
dened by Italian law; the period begins on the date of purchase as demonstrated by the sales receipt. The warranty is eective if the sales
receipt, bearing information identifying the device, is shown to the dealer or service personnel. The warranty covers the replacement or repair of
parts found defective due to faulty manufacture; shipping costs to and from service centers are charged to the customer.
In case of a repeated malfunction of the same origin or a malfunction that cannot be repaired, Mottura Serrature di Sicurezza S.p.A. may decide,
in its nal judgment, to replace the entire device. The warranty on the replacement device will continue to the expiration of the original device.
If the device must be serviced at the customer’s home, the customer is required to pay (if requested) a minimum charge to cover the transfer
costs of authorized service personnel.
Transport is at the customer’s risk if the customer ships the device, and at the service personnel’s risk if the device is picked up and transported
by service personnel.
LIMITS OF LIABILITY
The warranty does not cover damage deriving from:
- negligence, carelessness, or use other than as described below
- failure to protect the device before doing any procedure that may generate scrap or waste (welding, drilling of panels, drilling of structure, etc.) that prevents
its correct functioning
- maintenance work not conforming to these instructions or done by unauthorized personnel
- use of accessories/components that are not original Mottura products
- shipping of the device without the necessary precautions
- any circumstances not attributable to manufacturing defects.
Operating temperature: -10°C to +55°C. In addition, Mottura Serrature di Sicurezza S.p.A. declines all liability for any harm to persons or damage to property
deriving from failure to comply with all of the instructions and warnings contained in this manual.

2
ATTENTION: before powering and using this product, it is mandatory to read these notes, the instructions for use and any other
document supplied, both in paper and electronic format, including by means of links of any kind. This product is intended for the
exclusive use for which it was designed, built and sold; any other use other than that indicated as "compliant use" is not compliant
and therefore not admissible. The intended use for this product is:
INTERFACE WITH RELAY FOR ELECTRONIC LOCK OPENING
Any other use not expressly provided for or described here and in the ocial documentation is to be con-
sidered non-compliant and potentially dangerous for people, animals, things and the environment.
The user assumes all risks in case of use that does not comply with the description contained herein.
Mottura S.p.A. is in no way responsible for any non-compliant and unforeseen uses for this product, which may cause problems or
damage of any kind to people, animals, things and the environment.
1 - INTRODUCTION .......................................................................................................................... page 3
2 - SET-UP BUTTON FUNCTIONS
2.1 ngerprint escutcheon authentication ........................................................................................... 4
2.2 SETTING THE SINGLE RELAY MODE .............................................................................................................. 4
2.3 SETTING THE DOUBLE RELAY MODE .............................................................................................................. 4
2.4 Complete reset of the control unit .............................................................................................................. 4
3 - ELECTRICAL WIRING ................................................................................................................................. 5
4 - TECHNICAL DATA ................................................................................................................................. 5
5 - KEYPAD PROGRAMMING - TAG MANAGEMENT
5.1 MEMORIZING MASTER TAG KEYS ............................................................................................................... 6
5.2 MEMORIZING SERVICE TAG KEYS ............................................................................................................... 6
5.3 DELETING INDIVIDUAL TAG ............................................................................................................... 7
5.4 DELETING ALL TAG KEYS ................................................................................................................................. 7
5.5 DISABLING/ENABLING SERVICE TAG KEYS .......................................................................................................... 8
6 - Keypad PROGRAMMING - CODE MANAGEMENT
6.1 MEMORIZING PERSONAL ACCESS CODES ............................................................................................. 9
6.2 DELETING A PERSONAL ACCESS CODE ............................................................................................................... 9
6.3 DELETING ALL PERSONAL ACCESS ............................................................................................................... 10
7 - DOUBLE RELAY FUNCTION ................................................................................................................................... 11
Pursuant to article 26 of Italian Legislative Decree no. 49 of 14 March 2014 “Implementation of EU Directive 2012/19 concerning
waste electrical and electronic equipment (WEEE)” and article 9 of Italian Legislative Decree no. 188 of 20 November 2008 “Imple-
mentation of EC Directive 2006/66 on batteries and accumulators and waste batteries and accumulators” adequate waste sorting for
subsequent sending of disposed equipment to recycling, treatment and environmentally compatible disposal contributes to avoiding
possible negative eects on the environment and human health and promotes reuse and/or recycling of the materials composing
the equipment. Unlawful disposal of the product by the user may result in the application of penalties pursuant to current laws and
regulations on the matter. We remind that batteries and power adapters, if present, must be removed before the device is disposed.
Batteries and adapters must be collected and separately disposed.
WARNING : if there are no TAGs memorized in the control unit (when new or after a reset), the programming
mode can be accessed via any free MotturaTAG! Consequently, your own master TAGs need to be memorized
immediately, followed by any service TAGs, if foreseen, in order to ensure maximum security. After having
completed this, only thoseTAGs that have been memorized will be accepted by the control unit.

3
99.729
99.730
99.686
99.736
99.748
99.776
99.749
99.775
99.699
12/24 V
1 - INTRODUCTION
Relay MODULE (99.724) to start up to an actuator previously stored access credentials. Access credentials can
be a numeric code, a TAG RFID, or a ngerprint that can be inserted by means of a dedicated external device
connected to the control unit. Relay module permits the use of a Mottura electronic device (ngerprint reader
art. 99.729/730/748/776 or numeric keypad art. 99.686/736/749/775) on any electric, electronic or motorized
locks, via cable art. 99.699 (not included).
The system can operate with a keypad, with a TAG RFID reader or with a ngerprint, for security reasons it is
mandatory to store at least one master TAG to enable relay operation. The consensus given by the relay lasts
for 1 second. Main power 12-24 V ac-dc with mains adaptor cod. 99.683 or similar.
Relays can be congured, by means of the SET-UP button on the control unit, to work individually or in pairs.
SINGLE RALAY DOUBLE RELAY
OPEN OPEN / CLOSE
RALAY 1 Closes at any authorized access credential RALAY 1
Closes by entering an authorized access credential and pressing a key (*)
RALAY 2 not used RALAY 2
Closes by entering an authorized access credential and pressing a key (*)
(*) Depending on the type of showcase used, you must press a specic key within 10 sec. (See chapter 7).
This conguration is useful when you need to have two separate commands:
Such as one that opens and the other closes.
The consensus given by the relay lasts for 1 second.
LAYOUT
A/B
AUXILIARY
DEVICE
LAYOUT
C

4
5 sec.
10 sec.
5 sec.
2 - SET-UP BUTTON FUNCTIONS
Relay MODULE is factory set up end does not require any changes. The fol-
lowing steps should only be performed only if needed to change the original
setting. For example : replacing the keypad escutcheon with other device or if
you change the system and want to change the behavior of the output relays.
WARNING : Replacing the keypad escutcheon does not require authentication
because the codes are stored in the control unit.
The set-up button allows following functions:
- ngerprint authentication
- relay mode setting
- reset of the control unit.
2.1 FINGERPRINT ESCUTCHEON AUTHENTICATION
Fingerprint escutcheon must be authenticated with the control unit. For this operation, refer to the specic
instructions.
2.2 COMPLETE RESET OF THE CONTROL UNIT
Press SET-UP button for 5 seconds Exit
To set the mode with single relay (only R1 can close) press the button as follows :
2.3 SETTING THE DOUBLE RELAY MODE
To set the mode with double relay (both R1 and R2 can close) press the button as follows :
2.4 COMPLETE RESET OF THE CONTROL UNIT
Press SET-UP button for 10 seconds Exit
ExitPress SET-UP button Press SET-UP button for 5 secondsPress SET-UP button
ATTENTION : this operation deletes all tags, pin codes
(keypad escutcheon) or authentication (ngerprint
escutcheon - note: it does not erase the ngerprints
stored in it), and enables the service tags.
Press SET-UP button

5
R1
R1
R2
R2
VAL
VAL
A
B
R1
R2
VAL
C
3 - ELECTRICAL WIRING
SAFETY TRANSFORMER*
SAFETY TRANSFORMER
OR POWER SUPPLY
230 Vac
4 - TECHNICAL DATA
CONNECTION WITH MOTORIZED LOCKING
CONNECTION WITH MOTORIZED LOCKING
CONNECTING WITH MOTORIZED LOCKING + DEVICE FOR AUXILIARY FUNCTION
ELECTRIC LOCK
MOTORIZED LOCKING
With a clean contact control input
*The safety transformer must be chosen in accordance
with the power supply specications of the LOGICAL
UNIT and the electric lock
MOTORIZED LOCKING
With a clean contact control input
Timed electronic relay (lights command)
SAFETY TRANSFORMER
OR POWER SUPPLY
Requires control unit setup
For double relay.
INPUT POWER SUPPLY AC VOLTAGE / FREQUENCY 12 ÷ 24 Vac / 50-60Hz
DC VOLTAGE 12 ÷ 36 Vdc
MAX. POWER 3 W
MAX. CURRENT DRAW 250 mA
WORK TEMPERATURE Min -10 °C ÷ Max.+40 °C
MECHANICAL WEIGHT < 0,1 Kg
DIMENSIONS 105 x 38 x 20 mm
RELAY OUTPUTS MAX VOLTAGE / CURRENT 30V / 2A ac-dc
If only the control unit is powered, we recommend that you use MOTTURA’s network adapter cod. 99.683. Relay
contacts provide an impulse with a xed duration of 1 sec. Please refer to the wiring diagrams provided before
connecting the devices.

6
123
3 41 2
WARNING : if there are no TAGs memorized in the control unit (when new or after a reset), the programming
mode can be accessed via any free MotturaTAG! Consequently, your own master TAGs need to be memorized
immediately, followed by any service TAGs, if foreseen, in order to ensure maximum security. After having
completed this, only thoseTAGs that have been memorized will be accepted by the control unit.
ONLY for escutcheons 99775/99776 before each operation,
press any key to activate the escutcheon
Press P Enter master TAG (1) Enter master TAG (2)
5.1 MEMORIZING MASTER TAG
(1) If the lock is new or has been reset, you can enter the programming mode using any free Mottura TAG!
(2) which will become a MASTER TAG.
Memorizing
MASTER TAG
TAG
already memorized
as MASTER TAG
TAG
already memorized
as SERVICE TAG
To end, press “E”or wait for 30 seconds (exit time - timeout).
5 - KEYPAD PROGRAMMING - TAG MANAGEMENT
1
Press P
Enter TAG
5.2 MEMORIZING SERVICE TAG
Memorizing
MASTER TAG
TAG already
memorized as
MASTER TAG
TAG already
memorized as
SERVICE TAG
WARNING : if you try to memorize a service TAG before at least one masterTAG has been memorized, the
service TAG will automatically be memorized as a master TAG.
Press P Enter master TAG
To end, press “E”or wait for 30 seconds (exit time - timeout).

7
1 2 3 54
( )
X4
1 2 3
6
4 5
5.3 DELETING INDIVIDUAL TAGS
Press P Enter master TAG Press P
Enter TAG
Press P
TAG deleted TAG not
recognised
ERROR!
MASTER TAG
WARNING
: The master TAG used to enter the program-
ming mode CANNOT be deleted.
To end, press “E”or wait for 30 seconds (exit time - timeout).
5.4 DELETING ALL TAGS
Press P Enter master TAG Press P
Enter 7-8-9 and press E
Press P
TAG deletion in progress
Press P
To end, press “E”or wait for 30 seconds (exit time - timeout).

8
1
6
2 3 4 5
8
5.5 ENABLING/DISABLING SERVICE TAGS
Press P
Press P
Enter master TAG Press P
7 -ENABLE 7 - DISABLE
To enable enter 1-2-3 and
press E
To disable enter 3-2-1 and
press E
Press P Press P
Press P or E to exit
the programming mode
SERVICE TAGS, if entered,
are disabled
SERVICE TAGS, if entered,
are enabled

9
1 3
24
5 5
5
1 3 4
2
6 6
Enter the code
and press E
6 - KEYPAD PROGRAMMING - CODE MANAGEMENT
6.1 MEMORIZING PERSONAL ACCESS CODES
CODE
stored
CODE
already
memorized
Press P Present
MASTER TAG
To exit, press "E" or wait 30 sec. (timeout).
To exit, press "E" or wait 30 sec. (timeout).
WARNING
:
Enter a code
composed of a
minimum of 3
to a maximum
of 8 digits
Enter the code
and press E
CODE
deleted
ERROR !
Unknown CODE
6.2 DELETING A PERSONAL ACCESS CODE
Press P Present
MASTER TAG
ONLY for escutcheons 99775/99776 before each operation,
press any key to activate the escutcheon

10
6
1 3 4
25
7To exit, press "E" or wait 30 sec.
(timeout).
Type
9-8-7
and press E
Press P Present
MASTER TAG
6.3 DELETING ALL PERSONAL ACCESS
Deleting CODES in
progress
WARNING : If you push the "P" button, you will get the output from the programming.

11
14
2
2
2
2
3
3
99.686 / 736 / 749 / 77599.776
99.729 / 730 / 748
1 4
7 - DUAL RELAY FUNCTIONING
Where there are two relays, you have 10 seconds after entering your access credentials to select the RELAY to
be closed by pressing:
- "P" (on escutcheon 99.686/736/775), “1”(on escutcheon 99.729/730/748) or press (on escutcheon 99.776) for RELAY 1
- "E" (on escutcheon 99.686/736/775), “2”(on escutcheon 99.729/730/748) or press
(on escutcheon 99.776) for RELAY 2
a green or red LED respectively conrm closure of the selected relay.
In accordance with the escutcheon and relay mode, the control unit will act according to the following table:
Enter TAG
RELAY 1
Enter the CODE
and press E
Press P
Press P
ONLY for escutcheons 99775/99776 before each operation,
press any key to activate the escutcheon
Enter TAG
FINGERPRINT scan
Fingerprint
valid
Fingerprint
NOT valid
Return to point 1
Enter TAG
FINGERPRINT scan
Press 1
Press 1
Fingerprint
valid
Fingerprint
NOT valid
Return to point 1
Press
Press

www.mottura.it
2
2
3
99.686 / 736 / 749 / 77599.776
99.729 / 730 / 748
2
2
3
1 4
14
99332GB-REV.03 - 12/21 - a_025214
RELAY 2
Enter TAG
Enter the CODE
and press E
Press E
Press E
Enter TAG
FINGERPRINT scan
Press 2
Press 2
Fingerprint
valid
IFingerprint
NOT valid
Return to point 1
Enter TAG
FINGERPRINT scan
Fingerprint
valid
Fingerprint
NOT valid
Return to point 1
Press
Press
Table of contents