4
ASSEMBLY DIAGRAM
※ Read all instructions and precautions before use.
INSTRUCTIONS AND PRECAUTIONS
ELECTRIC DRUM PUMP for CHEMICALS
ELECTRIC DRUM PUMP
MODEL : 8017MRG
US 29/637,330 D755,925
EU 004709087-0001 002681833-0002
NO
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
Q`TY
1
1
1
1
1
1
2
2
9
2
1
1
1
1
1
1
1
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
2
3
2
1
1
1
1
1
1
1
1
1
1
1
1
FRONT COVER
BACK COVER
PCB ASS`Y
TOGGLE SWITCH
LED LAMP
WATERPROOF CAP
CONNECTER WIRE
CONNECTER PIN
SCREW
SCREW
BODY PACKING
BODY
O-RING(BODY)
DRUM BUNG ADAPTER
LOCK NUT
STAINLESS STEEL INNER PIPE
SUCTION PIPE(INNER)
O-RING(SUCTION PIPE(INNER), MOTOR COVER)
JOINT NUT(PIPE)
O-RING(PIPE)
SUCTION PIPE(OUTER)
MOTOR WIRE
MOTOR COVER PACKING
MOTOR COVER
O-5ING(MOTOR COVER TOP)
O-RING(MOTOR)
MOTOR
MOTOR PACKING
MOTOR CASE
IMPELLER
IMPELLER CASING
FILTER
END CAP
O-RING(HOSE ADAPTER, SPOUT)
HOSE ADAPTER
JOINT NUT(HOSE ADAPTER, SPOUT)
HOSE CLAMP
DISCHARGE HOSE
HANDLE
NOZZLE CAP
O-RING(NOZZLE CAP)
NOZZLE SPRING
NOZZLE PISTON
O-RING(PISTON L)
O-RING(PISTON S)
NOZZLE HOOK
SPOUT
NOZZLE LEVER
RIVET
PART NAME
•
Specications are subject to change without notice.
1-866-464-6553 www.holley.com
1801 Russellville Road, Bowling Green, KY, USA
9
8017MRG)
Directions for Use
7 8
6
5A
Operating temperature
Operating voltage DC12VApprox. 575 ~ 865mm (22.6”~ 34”)
Approx. 2m (6.6ft)
Delivery volume
Suction pipe length
Discharge hose length
Applicable liquids
Fuse
Duty Cycle (how long can the
pump be used continuously)
+5˚C ~ 40˚C (41˚F ~ 104˚F)
Methanol, Ethanol, DEF(AdBlue), Brake cleaner,
Liquid soap, Water(non potable)
11
2
Tighten the drum bung adapter.
Pull out the nozzle from the
nozzle holder.
Place the nozzle into the receiving
container to transfer liquid.
Toggle switch ON(Up).
Pull the nozzle lever and start
supplying the liquid.
Release the lever when the liquid
supply is completed.
Toggle switch OFF(Down).
Pulling the lever of the nozzle,
lift it up.
Let the left-over liquid in the hose Insert the nozzle in the nozzle holder
for storage.
2 3
4
10 12
5
Approx. 16 LPM (4.2 GPM) - DC12V at Water
Precautions for Use
DANGER WARNING CAUTION
CAUTIONDANGER WARNING
If the directions of this sign are not
followed, fatal accidents canhappen and
the user may die orgetseriously injured.
Do not use this pump for transferring the
following liquids; Gasoline, Diesel,
Kerosene, Lubricants, Aceton, Benzen,
Cresol, Phenol, Concentrated caustic soda
liquid, Nitric acid, Hydrochloric acid,
Sulfuric- acid, thinner or solvents, Etc.
Do not use for concentrated acids.
Only use on applicable liquids written on
Make sure to use the pump on even
surface.
Do not use when the cable and plug is
damaged or if plug is loose on outlet.
Keep the power supply adapter out of
direct sunlight, water vapor, soft coal,
dust, and damp air etc.
Do not touch and operate any plug or
power supply units with wet hands.
These instructions are to ensure the product is used correctly, safely, and to prevent any possible risk or damage to the user
and/or others people. Our company shall not take any responsibility for any failure of product, malfunction and damages
caused by improper use by the user or third parties.
Make sure the pump is tightly secured
to the drum(tank) before turning the
pump on.
Do not leave the pump unattended.
Do not allow children to operate the
product without adult supervision.
Wash and clean out the outlet, plug,
and plug blades regularly.
If the power supply adapter falls into
the water, pull the plug out and do not
reuse it.
Make sure to hold on the plug and pull
the cable)
Do not get power cord damaged, bent,
pulled, twisted, or bound.
Do not get the plug and outlet wet in
any case.
When disposing of pump, make sure to
have it completely destroyed so that
others won’t use it again.
When you hand it over to another
person, be sure to give them the
instructions too.
Do not use deteriorated or contaminated
liquids.
Do not use this pump for hot liquids
above 40°C (104°F ).
Use it in a well-ventilated area since the
power supply adaptor becomes a little
hot.
Do not run the pump ‘dry’ or let the pump
idle without transferring.
Do not run the pump for longer than 15
minutes.
using the pump.
Make sure to remove any left-over liquid
in the discharge hose after each use.
After using the pump, do not keep it on
its side or upside down.
Do not alter or disassemble the pump.
Do not shock the pump and power
supply adapter. Also do not make the
power cord tense.
When cleaning up the pump, do not use
thinner, benzene, organic solvent, or
glass cleaners.
If the directions of this sign are not
followed, accidents can happen or
the user can get injured.
If the directions of this sign are not
followed, the product can get damaged
or the user can getinjured.
1
Adjust the length of the suction pipe
Insert the
suction pipe into the drum (tank).
3
Connect the power supply to
the Pump.
Toggle Switch
Nozzle
Drum bung adapter
Suction pipe
Discharge hose
Operating lamp(LED)
Adjustment nut
Names of Parts
Pull nozzle lever and turn the nozzle hook left or right
Keep the nozzle hook at 12 o'clock direction after use.
Nozzle hook
Nozzle lever
DO NOT LEAVE PUMP UNATTENDED
WITH NOZZLE IN LOCKED POSITION
WHILE REFUELING.
FAILURE TO DO SO CAN RESULT IN
OVERFLOW CAUSING DEATH OR
SERIOUS INJURY.
ALWAYS REMOVE NOZZLE FROM
LOCKED POSITION AFTER
REFUELING AND TURNING OFF.

Other Mr. Gasket Water Pump manuals

Mr. Gasket 12S User manual

Mr. Gasket

Mr. Gasket 12S User manual

Mr. Gasket 12D User manual

Mr. Gasket

Mr. Gasket 12D User manual

Popular Water Pump manuals by other brands

Flotec 1100X Series quick start guide

Flotec

Flotec 1100X Series quick start guide

Becker T 4.25 DV operating instructions

Becker

Becker T 4.25 DV operating instructions

Xylem LOWARA e-LNEEE quick start guide

Xylem

Xylem LOWARA e-LNEEE quick start guide

Daewoo DDP17000 user manual

Daewoo

Daewoo DDP17000 user manual

Orion 22705 user manual

Orion

Orion 22705 user manual

Franklin Electric TurfBOSS TB15CI owner's manual

Franklin Electric

Franklin Electric TurfBOSS TB15CI owner's manual

BVA Hydraulics P570FP instruction manual

BVA Hydraulics

BVA Hydraulics P570FP instruction manual

Pfeiffer Vacuum ATH 2800 MT operating instructions

Pfeiffer Vacuum

Pfeiffer Vacuum ATH 2800 MT operating instructions

KSB Amarex KRT Installation & operating manual

KSB

KSB Amarex KRT Installation & operating manual

Enerpac ZUTP1500-S Series instruction sheet

Enerpac

Enerpac ZUTP1500-S Series instruction sheet

Colfax Allweiler AE Series Operating and maintenance instructions

Colfax

Colfax Allweiler AE Series Operating and maintenance instructions

Garland AMAZON 300 E instruction manual

Garland

Garland AMAZON 300 E instruction manual

Gehmann M220 manual

Gehmann

Gehmann M220 manual

Grundfos UPM3 FLE quick start guide

Grundfos

Grundfos UPM3 FLE quick start guide

Graco Series A Instructions-parts list

Graco

Graco Series A Instructions-parts list

DIPRA SPIDO EC 300 instruction manual

DIPRA

DIPRA SPIDO EC 300 instruction manual

Pentair AQUATIC ECO-SYSTEMS SPARUS 348045-AQ Installation and user guide

Pentair

Pentair AQUATIC ECO-SYSTEMS SPARUS 348045-AQ Installation and user guide

Becker VX 4.16 operating instructions

Becker

Becker VX 4.16 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.