WARNING
CAUTION
• Wiring routing must be properly arranged so that the control board cover is fixed properly. If the control
board cover is not fixed perfectly, it can cause overheating at the terminal connection point, fire, or
electrical shock.
• If the supply cord is damaged, it must be replaced by the manufacturer, service agent, or other qualified
person in order to avoid a hazard.
• An all-pole disconnection switch with a contact separation of at least 0.12in in all poles should be
connected in fixed wiring.
• When completing piping connection, take proper precautions to avoid air substances entering the
refrigeration cycle. Otherwise, it can cause lower capacity, abnormally high pressure in the refrigeration
cycle, explosion, and/or injury.
• Do not modify the length of the power supply cord, use an extension cord, or share the single outlet with
any other electrical appliances. Otherwise, it can cause fire or electrical shock.
• If the refrigerant leaks during installation, ventilate the area immediately. Toxic gas may be produced if
the refrigerant comes in contact with fire.
• The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the
copper tube.
• After completing the installation work, check that the refrigerant does not leak. Toxic gas may be
produced if the refrigerant leaks into the room and comes into contact with a source of fire, such as a
heater, stove or cooker.
• After completing the installation, make sure that the unit operates properly during the start-up operation.
Please instruct the customer on how to operate the unit and keep it maintained. Also, inform customers
that they should store this installation manual along with the owner's manual for future reference.
Safety Precautions
Page 3 mrcool.com
DO NOT connect the ground wire to gas or water pipes, lightning rod, or a telephone ground wire.
Inappropriate grounding may result in electrical shocks.
DO NOT allow children to play with the air conditioner. Children or impaired individuals should be
supervised around the unit at all times.
DO NOT connect the air conditioner with the power supply until the wiring and piping is done.
DO NOT operate your air conditioner in a wet room such as a bathroom or laundry room.
DO NOT install the air conditioner in any of the following circumstances:
• There is petrolatum existing.
• There is salty air surrounding (near the coast).
• There is caustic gas (the sulfide, for example) existing in the air (near a hot spring).
• The volt vibrates violently (in factories).
• In buses or cabinets.
• In kitchen where it is full of oil gas.
• There are strong electromagnetic waves existing.
• There are inflammable materials or gases.
• There is acid or alkaline liquid evaporating.
• Other special conditions.
• Ground the air conditioner.
• Be sure to install an earth leakage breaker. Failure to install an earth leakage breaker may result in
electrical shock.
• Connect the outdoor unit wires first, then connect the indoor unit wires.