ME55 Programmable Heating Thermostat with LCD Screen User manual
Shenzhen Myuet Energy Saving Equipment Co., Ltd. 1
Programmable Heating Thermostat with LCD Screen
Weekly circulation, it is possible to set 6 periods called events
each day with corresponding pre-set temperatures. You can
select “period control mode”or “manual mode”according to your
requirement. The thermostat is recommended for control of
electric heating devices or on/off valve actuator used in water-
based system.
Availability
Technical data
Voltage: 110-230V AC ,50/60Hz
Power consumption: 2W
Temperature setting range: 5-95℃
Temperature limitation range: 5-60℃(factory setting: 35℃)
Switching differential: 0.5-10℃adjustable, factory setting ±1℃
Ambient temperature: -5~50℃
Protective housing: IP20
Housing material: anti-flammable PC
Dimensions(H/W/D): 90/86/43mm
User Operation
1) Power key ““
Press the key to turn on/off the thermostat, you can also
confirm and exit through it when completing the setting of
every parameter.
2) The increase key “▲”and decrease key”▼”
Press “▲” or”▼”key to adjust temperature and the value of
pre-set temperature will be increased/decreased by 0.5℃each
time in “manual mode” or “ period control mode”. Furthermore,
in “period control mode” apart from value change its alternate
display also stops, it will recover the alternate display with no
operation for 3 seconds.
3) Time setting
Press “““▲”key and hold for 5 seconds
simultaneously to adjust time. Press ““to choose
object for adjusting ; press “▲” or”▼”to increase
/decrease your set values. Press “ ”to confirm and exit.
4) Mode selection key ““
You can select “period control mode” or “manual mode” by
this key. In “ period control mode”, it displays the time or
the pre-set temperature alternately, and the measured
temperature displayed directly. Press “ ” and hold for
5 seconds to enter the mode of period programming.
5) Locking ““and unlocking
Press “▲”and “▼”simultaneously and hold for 5 seconds,
the thermostat will be locked / unlocked. When locked, no
operation can be carried out until it is unlocked.
Display symbols
“ ” Manual mode
“ ” Period control mode
“”Wake-up, event 1
“ ” Leave, event 2
“ ” Return(am), event 3
“ ” Leave(pm), event 4
“ ” Return(pm), event 5
“”Sleep, event 6
“ ” Heating on
Programming: 6 –event time and temperature
Press ““key and hold for 5 seconds to enter programming
mode.