Neptronic CMMB1322 User manual

CMMB1
Mo
d
CMM
De
s
The
C
requi
r
Com
b
Auto
m
existi
n
comp
Fe
a
1
2
2
2
2
f
o
D
R
L
B
Te
c
Input
V
Cons
u
Auxili
a
Inputs
Super
v
Com
m
Com
m
Electr
i
Oper
a
Stora
g
Relati
v
Weig
h
Dime
n
A = 6.
3
B = 5.
0
C = 2.
322-140819-ESL
d
el
B1322
s
cription
C
MMB extend
s
r
es additional i
n
b
ining the inpu
t
m
ation System
n
g controller a
n
onents.
a
tures
20 Vac or 240
2
auxiliary sup
p
2
universal inp
u
2
digital output
s
2
override swit
c
o
rced on, or fo
D
IN rail mounti
n
R
emovable, no
L
ED status indi
B
ACnet
®
oMS/T
P
oAuto
m
oAuto
m
oCopy
a
modul
e
c
hnical S
p
Desc
r
V
oltage
u
mption
a
ry Supply Outp
u
v
ised Outputs
m
unication Proto
c
m
unication Conn
e
i
cal Connection
s
a
tional Temperat
u
g
e Temperature
v
e Humidity
h
t
n
sions:
3
0” |160 mm
0
0” |126 mm
25” | 57 mm
s
your BACnet
n
puts and out
p
t
s and outputs
provides simp
n
d reduces un
n
Vac (selectab
p
ly outputs (24
u
ts
s
c
hes to manua
l
rced off)
n
g
n-strip, raising
cation of each
P
@ 9600, 192
0
m
atic baud rate
m
atic device in
s
a
nd broadcast
e
s
p
ecificat
i
r
iption
u
ts
c
ol
e
ctions
s
u
re
network when
p
uts on a physi
of the CMMB
w
le expansion
o
n
ecessary cos
t
le)
Vdc and 24 V
a
l
ly control eac
h
clamp termin
a
input and out
p
0
0, 38400 or
7
detection
s
tance configur
configuration
t
i
ons
120 V
a
4VA
- 1 out
p
- 1 out
p
- therm
- 2 uni
v
- 0-10
V
- 12 bit
- 2 rela
- indep
e
- norm
a
- BAC
n
- BAC
n
24 AW
G
0.8 m
m
0ºC to
5
-30ºC t
5 to 95
0.4 kg
[
ON
1 2 3 4 5 6 7 8
1 2 3 4
your applicati
o
cal controller.
w
ith your Build
o
f a new or
t
s of additional
a
c)
h
output (auto,
a
ls
p
ut
7
6800 bps
ation
t
o other CMM
B
a
c or 240 Vac (s
e
p
ut: 24 Vdc (100
p
ut: 24 Vac (300
al fuse (resetta
b
v
ersal inputs
V
dc, Thermistor
1
resolution
y outputs (277
V
e
ndent common
a
lly open
n
et
®
MS/TP @ 9
6
n
et
®
Application
S
G
twisted-shield
m
2
[18 AWG] mini
5
0ºC [32ºF to 1
2
o 50ºC [-22ºF to
% non condens
e
[
0.9 lb]
A
o
n
ing
B
e
lectable)
mA max)
mA max)
b
le)
1
0KΩ(type 3), o
n
V
ac / 30A resisti
v
per relay
6
00, 19200, 384
0
S
pecific Controll
e
cable (Belden 9
8
mum
2
2ºF]
122ºF]
e
d
B
Specifi
c
CMMB132
2
n
/off (dry contac
t
v
e | 240 Vac
/
3/
4
0
0 or 76800 bps
e
r (B-ASC)
8
41 or equivale
n
C
Remote
c
ation and I
CMMB1
3
2
t
), 4-20mA
4
HP)
n
t)
BACnet
I
nstallation
3
22
I
/O Boar
d
Instruction
s
Page |
1
d
s
1

www.
n
Co
n
LE
D
Po
w
On
Off
Sta
t
Flash
RX/
T
Flash
Co
m
A+:
B-:
Uni
v
** S
e
EU1
:
CO
M
EU2
:
V
olt
a
** 1
0
CO
M
+24
V
V
olt
a
** 3
0
CO
M
CO
M
24V
A
24V
A
End
1
2
* by d
e
EU1
EU2
* by d
e
n
eptronic.com
n
nection
s
D
s
w
er
= Input v
o
= No po
w
t
us
ing = Norma
l
T
X (BACn
e
ing = Receiv
m
munication | TB
5
RS-485 A+
RS-485 B-
v
ersal Inputs | TB
7
e
lectable **
:
Universal Inpu
t
M
: Common
:
Universal Inpu
t
a
ge 24 Vdc | TB9
0
0mA max **
M
: Common
V
: 24 Vdc
a
ge 24 Vac | TB1
0
0
0mA max **
M
: Common
M
: Common
A
C:24 Vac
A
C:24 Vac
of Line | JP1
N
o
2
0 Ohms
e
fault
Signal | JP2
Signal | JP3
I=4-20mA
T* = 10K Ohms
V= 0-10Vdc
e
fault
s
and Co
o
ltage normal
w
er
l
operation (w
a
e
t)
ing (RX) and/
o
5
A
B
7
t
1
t
2
0
U
C
O
U
C
O
+2
4
C
O
C
O
24
VA
24
VA
o
ne*
/ on-off
MA
C
The
bina
add
r
nfigurati
o
a
tchdog)
o
r transmitting
(
A
+
B
-
POWER
STATUS
TX RX
I
T
V
I
T
V
JP2 JP3
I
1
O
M
I
2
O
M
4
V
O
M
O
M
A
C
A
C
JP1
C
Address | DS2
8 DIP switches re
ry logic to calcula
t
r
ess. Default = all
O
o
ns
(
TX) data.
I
O
O
F
A
O
O
O
F
ON
1 2 3 4 5 6 7 8
Tran
1
DS2
present a
t
e the
M
AC
O
FF
I
nput Stat
u
O
n = In
p
O
ff = In
p
F
lashing = In
p
A
nalog =
W
10K
exa
m
will
b
O
utput St
a
O
n = A
c
O
ff = D
e
F
lashing = O
u
sforme
r
0VA
277 Vac / 3
0
240 Vac / 3/
4
1 2 3 4
ON
DS1
Specifi
c
u
s
p
ut on
p
ut off
p
ut not conne
c
W
hen Universal
Ω); the LED in
t
m
ple: At 10Vd
c
b
e at 50% inte
n
a
tus
c
tivated
e
activated
u
tput pulsed
115
0
A resistive
4
HP
SW2SW3
Remote
c
ation and I
c
ted (thermisto
r
Inputs are set
t
ensity corres
p
c
, the LED will
n
sity. At 0 Vdc
P
L
D
C
D
C
V
RET
LINE
COM
NO1
COM
NO2
N
O
N
O
* b
y
P
Ba
3
O
F
O
N
1
O
F
O
F
O
N
O
N
* d
e
BACnet
I
nstallation
r
setting only)
to analog valu
e
p
onds to the in
p
be fully on. At
, the LED will
b
P
ower | TB4
** Selectable **
RE
T
: Return
L
INE: 120 Vac or
2
D
igital Output 1 |
C
OM: Common
N
O
1: Normally
o
D
igital Output 2 |
C
OM: Common
N
O
2: Normally
o
O
2 Override Swit
c
O
1 Override Swit
c
Manual = Clo
s
Auto* = Aut
o
Off = Ope
y
default
P
ower Supply S
e
120 Vac*
* by default
ud Rate | DS1
Result
FF
Auto D
e
N
Manual
2Result
FF
OFF 9,600
FF
ON 19,200
N
OFF 38,400
N
ON 76,800
e
fault setting
I
/O Boar
d
Instruction
s
Page |
2
e
s (Vdc, mA,
o
p
ut value. For
5Vdc, the LE
D
b
e off.
2
40 Vac
TB3
o
pen
TB2
o
pen
c
h | SW2
c
h | SW3
s
e
d
o
matic
n
e
lector
240 Vac
e
tect*
(see 1 & 2)
d
s
2
o
r
D

www.
n
BA
C
Uni
v
W
I
f
a
W
Dig
i
A
T
A
t
h
n
eptronic.com
C
net Co
n
Pl
e
of
a
v
ersal Inp
u
W
hen the jump
f
the universal
a
n “on” signal
w
W
hen the jump
i
tal Outpu
t
A
fixed output (
o
T
he displayed
t
A
ll outputs are
f
h
e on-board s
w
n
figurati
o
e
ase note that
a
dditional co
n
u
ts (UI1-UI
2
er is set to Th
e
input is set as
w
ould be recog
er is set to 0-1
0
t
s (Relays)
o
pen/closed)
c
t
ext can be set
f
ully supervise
d
w
itches.
o
ns
all jumper se
n
figurations t
h
2
)
e
rmistor, you c
a
a digital on/off
nized as an “o
f
0
Vdc, you ca
n
c
an only be mo
to either Ope
n
d
via BACnet.
T
ttings must a
l
h
at are only a
v
a
n select eithe
input, you ca
n
f
f” signal.
n
also set the r
a
dified via BAC
n
/Closed, On/
O
T
his provides
t
l
so be set to t
h
v
ailable throu
g
r °C or °F or y
o
n
also set the p
o
a
nge to 0-5 Vd
net when the
o
O
ff, or Alarm/N
o
t
he actual stat
e
Specifi
c
h
e same valu
e
g
h BACnet.
o
u can set the
o
larity to direc
t
c (MSV).
o
verride switch
o
rmal.
e
of the output
Remote
c
ation and I
e
through BA
C
input as a digi
t
t
or reverse (B
V
is in the “Auto
including any
m
BACnet
I
nstallation
C
net. The foll
o
t
al on/off input
V
). For exampl
matic” position
m
anual overrid
I
/O Boar
d
Instruction
s
Page |
3
o
wing is a lis
t
(MSV).
e, in Reverse
(BV).
es done using
d
s
3
t

www.
n
BA
C
Objec
t
Objec
t
Descr
i
Objec
t
Syste
m
Vend
o
Vend
o
Model
_
Firm
w
Appli
c
Proto
c
Proto
c
Data
B
Max_
A
Segm
e
APDU
Numb
e
Proto
c
Proto
c
Supp
o
Objec
t
Devic
e
Max_
M
Max_I
Propri
e
Propri
e
Propri
e
n
eptronic.com
C
net De
v
Prope
r
t
_Identifie
r
t
_Name
i
ption
t
_Type
m
_Status
o
r_Identifie
r
o
r_Name
_
Name
w
are_Revision
c
ation_Software
_
c
ol_Version
c
ol_Revision
B
ase_Revision
A
PDU_Length_
A
e
ntation_Suppo
r
_Timeout
e
r_of_APDU_R
e
c
ol_Services_Su
c
ol_Object_Type
o
rted
t
_List
e
_Address_Bind
M
aste
r
nfo_Frames
e
tary property #
1
e
tary property #
1
e
tary property #
1
v
ice Obje
c
r
ty
_
Version
A
ccepted
r
ted
e
tries
pported
s
_
ing
1
000
1
001
1
002
c
t Prope
r
Programm
a
The device
instance=1
5
Programm
a
default val
u
Programm
a
Device
Always OP
E
Always 15
3
Always Ne
p
Example,
C
currently, 1
currently, 1
Always 1
Always 4
Default = 0
,
Always 48
0
(3) = No S
e
60,000
Always 0
Always 0x
0
- writePro
p
- writePro
p
- deviceC
o
- unconfir
m
- who-Is,
w
Always 0
x
- analog-i
n
- device
- multi-sta
t
Per the sta
n
Object_Li
s
Always em
p
Programm
a
Always 1
Read o
This pr
o
Read o
This pr
o
Values
Default
Progra
m
This pr
o
autom
a
Writing
Default
r
ties
a
ble where the i
n
instance must
b
5
3000 (Vendor_
a
ble up to 32 ch
a
u
e is Model_Na
m
a
ble up to 32 ch
a
E
RATIONAL (0)
3
p
tronic
C
MMB1322
.01
.01
,
will be increme
n
0
e
gmentation
0
0, 0x0B, 0xC0
p
erty, readProp
e
p
ertyMultiple, re
o
mmunicationC
o
m
edPrivateTran
s
w
ho-Has
x
00, 0xB4, 0x8
0
n
put, analog-v
a
t
e-value
n
dard. Because
s
tcannot be retu
p
ty
a
ble in the range
nly
o
prietary proper
t
nly
o
prietary proper
t
are 0 (auto), 96
0
is Auto
m
mable
o
p
r
ietary proper
t
a
tically return to
n
0 means no aut
o
is 15 minutes
V
n
stance part of t
h
b
e unique syste
m
Identifier*1000
+
a
racters. The de
v
m
e
a
racters. The de
f
n
ted if Object_N
a
, 0x02, 0x60 (i.
e
e
rty
adPropertyMul
t
o
ntrol
s
fe
r
0
, 0x10 (i.e. a
b
a
lue, binar
y
-in
p
of restrictions o
n
rned at once, ra
t
of 1-127 (Defau
t
y represents th
e
t
y represents th
e
0
0, 19200, 3840
0
t
y represents th
e
n
ormal. Range =
o
matic return to
Specifi
c
V
alue
h
e Object_Identi
f
m
-wide. The defa
u
+
MSTP ADD (
d
v
ice name must
b
f
ault value is "B
A
a
me and/or Odj
e
e
. a bitstring in
B
t
iple
b
itstring in BA
C
p
ut, binary-val
u
n
the size of the
t
t
her the Object
_
lt value=127)
e
MS/TP MAC a
d
e
MS/TP baud ra
t
0
, 76800
e
period of time t
h
0-120 minutes
(
normal
Remote
c
ation and I
f
ier is in the rang
u
lt value for the
d
ipswitch)
)
b
e unique syste
m
A
Cnet I/O card"
e
ct_Identifier is
m
B
ACnet
®
order)
C
net
®
order)
u
e
t
ransmit buffers,
_
List must be re
a
d
dress in the ran
g
t
e
h
at an object in/
o
(
unsigned type)
BACnet
I
nstallation
e of 0-4194302.
device
m
-wide. The
m
odified
the entire
a
d, one-at-a-tim
e
g
e of 0-254
o
ut of service wil
I
/O Boar
d
Instruction
s
Page |
4
Writable
W
W
W
e
.
W
l
W
d
s
4

www.
n
Ob
j
The
h
Obje
c
obje
c
long
)
An
a
ID
AI.1
AI.2
An
a
ID
AV.
1
AV.
1
AV.
1
AV.
2
AV.
2
AV.
4
AV.
4
AV.
4
Bin
a
ID
BV.
2
BV.
2
BV.
9
BV.
9
BV.
1
1
Writ
e
n
eptronic.com
j
ect Tabl
e
h
umidifiers u
s
c
t type, the i
n
c
t according t
o
)
type<<22)+
i
a
log Input
(
Name
Universal
Extern T
e
a
log Value
Name
1
65 MSTPBa
u
1
66 MSTPAd
d
1
67 DeviceIn
s
2
26 Universal
2
27 Universal
4
68 CopyCfg
S
4
69 CopyCfg
E
4
70 CopyCfg
R
a
ry Value
(
Name
2
2 Contact
O
2
3 Contact
O
9
3 UI1_DI_
P
9
4 UI2_DI_
P
1
01 CopyCfg
E
e
address in pre
s
e
Inform
a
s
e the followi
n
n
stance is th
e
o
the followi
n
i
nstance
(
AI)
Input1
e
mp
(AV)
u
dRate
d
s
tance
Input1Offset
Input2Offset
S
tartAdd
E
ndAdd
R
esult
1
(
BV)
O
utput1
O
utput2
P
olarity
P
olarity
E
xecute
s
ent value, resul
t
a
tion
n
g BACnet o
b
e
BACnet Obj
e
n
g C-languag
e
Descriptio
n
Universal inp
u
MSV.1
Universal inp
u
MSV.12
Descriptio
n
MSTP Baud
R
MSTP MAC
A
Device Instan
Universal inp
u
Universal inp
u
Copy configu
r
Copy configu
r
Copy configu
r
Descriptio
n
Digital output
Digital output
Polarity of uni
when used in
Polarity of uni
when used in
Start or stop
c
t
will be availabl
e
b
ject tables,
c
e
ct. Togethe
r
e
algorithm:
o
n
u
t 1 mode select
e
u
t 1 mode select
e
n
R
ate
A
ddress
ce
u
t 1 offset
u
t 2 offset
r
ation start addr
e
r
ation end addre
s
r
ation result
n
1 status
2 status
versal input 1
digital input mo
d
versal input 2
digital input mo
d
c
opy configurati
o
e
in description.
c
ategorized o
r
, the type an
d
o
bject_identi
Writ
a
Pro
p
e
d by Out
o
e
d by Out
o
Writ
a
Pro
p
N/A
N/A
Pres
e
Pres
e
Pres
e
e
ss Pres
e
s
s Pres
e
Pres
e
Writ
a
Pro
p
Pres
e
Pres
e
d
e Pres
e
d
e Pres
e
o
n Pres
e
Specifi
c
n the basis o
f
d
instance fo
r
fier=(unsign
a
ble
p
erty N
o
o
f service 0-
R
e
o
f service 0-
R
e
a
ble
p
erty N
o
9
6
0
t
e
nt Value 0
t
e
nt Value -5
R
e
e
nt Value -5
R
e
e
nt Value 0-
2
A
v
e
nt Value
A
V
A
d
A
v
e
nt Value
A
V
R
e
a
n
R
e
M
o
C
o
a
ble
p
erty N
o
(*
e
nt Value
0
=
1
=
T
e
e
nt Value
0
=
1
=
T
e
e
nt Value
0
=
1
=
e
nt Value
0
=
1
=
e
nt Value
0
=
1
=
St
Remote
c
ation and I
f
their ID. Th
e
r
m the BACn
ed long)((u
n
o
tes
10Volt or -40-10
0
e
solution 0.01V
o
10Volt or -40-10
0
e
solution 0.01V
o
o
tes
6
00, 19200, 384
0
t
o 127
t
o 4194302
.00 to 5.00 ºC/º
F
e
solution: 0.01 º
C
.00 to 5.00 ºC/º
F
e
solution: 0.01 º
C
2
54 Address of
f
v
ailable only if B
V
V
.468 – (AV.468
d
dress of last C
M
v
ailable only if B
V
V
.468 – AV.469
e
sult of copy is
a
n
d is available o
n
e
sults: Succeed,
o
del_Error, FW
_
o
mm_Error, Sla
v
o
tes
= default)
=
Open / Ouvert
/
=
Close / Fermé
/
e
xt depends of s
e
=
Open / Ouvert
/
=
Close / Fermé
/
e
xt depends of s
e
=
Direct *
=
Reverse
=
Direct *
=
Reverse
=
No *
=
Yes
art copy and giv
e
BACnet
I
nstallation
e
type is the
B
et Object_Id
n
signed
0
ºC or -40-212º
F
o
lt or 0.01ºC/0.0
2
0
ºC or -40-212º
F
o
lt or 0.01ºC/0.0
2
0
0, 76800
F
/Volt/mA (defau
l
C
/ºF/Volt/mA
F
/Volt/mA (defau
l
C
/ºF/Volt/mA
f
irst CMMB to co
V
.101 is set to N
+ 64)
M
MB to copy
V
.101 is set to N
a
vailable on Des
c
n
ly if BV.101 is s
e
Prog_Error, Ty
p
_
Error, Mem_Err
o
v
eDevice, InPro
g
/
Off / Arret / N
o
/
On / Marche /
A
e
lection in MSV.
6
/
Off / Arret / N
o
/
On / Marche /
A
e
lection in MSV.
6
e
results, must
b
I
/O Boar
d
Instruction
s
Page |
5
B
ACnet
entifier for a
n
F
or 0-1
2
ºF
F
or 0-1
2
ºF
l
t 0*)
l
t 0*)
py
o
o
c
ription property
e
t to Yes.
p
e_Error,
o
r, Size_Error,
g
ress, AllSuccee
d
o
rmal *
A
larm
6
6
o
rmal *
A
larm
6
7
b
e reset by user.
d
s
5
n
d

www.
n
Mul
t
ID
MS
V
MS
V
MS
V
MS
V
n
eptronic.com
t
i-State V
a
Name
V
.1 Universal
V
.12 Universal
V
.66 Contact
O
V
.67 Contact
O
a
lue (MSV)
Input1Function
Input2Function
O
utput1Text
O
utput2Text
Descriptio
n
Selected anal
Selected anal
Contact outp
u
text
Contact outp
u
text
n
og input 1 mode
og input 2 mode
u
t 1 inactive & a
c
u
t 2 inactive & a
c
Writ
a
Pro
p
Pres
e
Pres
e
c
tive Pres
e
c
tive Pres
e
Specifi
c
a
ble
p
erty N
o
(*
e
nt Value
1
=
2
=
3
=
4
=
5
=
6
=
e
nt Value
1
=
2
=
3
=
4
=
5
=
6
=
e
nt Value
1
=
2
=
3
=
4
=
5
=
e
nt Value
1
=
2
=
3
=
4
=
5
=
Remote
c
ation and I
o
tes
= default)
=
Extern_Sensor
_
=
Extern_Sensor
_
=
0_10Volt
=
DigitalInput
=
0_5Volt
=
4_20mA
=
Extern_Sensor
_
=
Extern_Sensor
_
=
0_10Volt
=
DigitalInput
=
0_5Volt
=
4_20mA
=
Open_Close *
=
Ouvert_Fermé
=
On_Off
=
Marche_Arret
=
Alarm_Normal
=
Open_Close *
=
Ouvert_Fermé
=
On_Off
=
Marche_Arret
=
Alarm_Normal
BACnet
I
nstallation
_
C *
_
F
_
C *
_
F
I
/O Boar
d
Instruction
s
Page |
6
d
s
6

www.
n
No
t
n
eptronic.com
t
es
Recyclin
g
Neptroni
c
g
at end of life
:
c
authorized dis
t
:
please return
t
t
ributor, please c
t
his product to
onsult www.ne
p
your Neptronic
p
tronic.com.
Specifi
c
local distributor
Remote
c
ation and I
for recycling. I
f
BACnet
I
nstallation
f
you need to fi
I
/O Boar
d
Instruction
s
Page |
7
nd the nearest
d
s
7

400 Lebeau blvd, Montreal, Qc, H4N 1R6, Canada
www.neptronic.com
Toll free in North America: 1-800-361-2308
Tel.: (514) 333-1433
Fax: (514) 333-3163
Customer service fax: (514) 333-1091
Monday to Friday: 8:00am to 5:00pm (Eastern time)
Popular I/O System manuals by other brands

Mitsubishi
Mitsubishi AJ65BT-64RD3 user manual

Measurement Computing
Measurement Computing us-1208fs user guide

Maple Systems
Maple Systems HMC3-M0808P0401T manual

M-system
M-system R5-SS instruction manual

HomeMatic
HomeMatic HmIP-MIOB Installation instructions and operating manual

D-TACQ Solutions
D-TACQ Solutions ACQ132CPCI Hardware installation guide

Romutec
Romutec romod-eco Series Technical Documentation/Instruction Manual

Hardy
Hardy HI 1734-WS Installation & operation manual

Panasonic
Panasonic FZ-VCN40 Series operating instructions

Waveshare
Waveshare Compute Module IO Board Plus user manual

National Instruments
National Instruments FieldPoint FP-1300 quick start guide

IFM
IFM AL4042 operating instructions