Netwox ZigBee Z803 User manual

ZigBeeTM- Power Strip with Power Consumption Monitoring
User Manual
Power Strip with Power Consumption Monitoring
Model: Z803
Firmware: V3.0
Hardware: V1.0~V1.1
20150824

1
Table of Contents
1. Introduction.............................................................................................................................................................. 2
2. Product Appearance.................................................................................................................................................3
3. Specification.............................................................................................................................................................. 4
4. Installation.................................................................................................................................................................4
5. Setting up Z803......................................................................................................................................................... 4
5-1. Join the ZigBee Network................................................................................................................................ 4
5-2. Binding............................................................................................................................................................5
5-3. Permit-Join...................................................................................................................................................... 5
5-4. Identification................................................................................................................................................... 6
5-5. LCD Display................................................................................................................................................... 6
5-6. Reset Power Consumption Summation.......................................................................................................... 6
5-7. Restore to Factory Setting...............................................................................................................................6
6. Home Automation Clusters for Z803..................................................................................................................... 7
7. Important Maintenance Instructions..................................................................................................................... 9

2
1. Introduction
Netvox Z803, a ZigBee power socket with power consumption monitoring, acts as a Router Device in ZigBee
network. It performs the On/Off controlling feature for users to manage each On/Off switch. Users are able to
wirelessly control the switch through paired soft On/Off button or paired remote controller. Users could monitor
the power consumptions such as current/ voltage/ power/ energy via the built-in LCD or through Netvox
ZiG-BUTLER application.
What is ZigBee?
ZigBee is a short range wireless transmission technology based on IEEE802.15.4 standard and supports multiple
network topologies such as point-to-point, point-to-multipoint, and mesh networks. It is defined for a
general-purpose, cost-effective, low-power-consumption, low-data-rate, and easy-to-install wireless solution for
industrial control, embedded sensing, medical data collection, smoke and intruder warning, building automation
and home automation, etc.

3
2. Product Appearance
Extension Cord
LCD Display
Switch 1
Switch 2
Switch 3
Switch 4
Resettable Fuse
Power Switch
Match Key
Bind Key
Socket 4
Socket 3
Socket 2
Socket 1

4
3. Specification
Fully IEEE 802.15.4 compliant (ZigBee Pro)
Utilizes 2.4GHz ISM band; up to 16 channels
Power supply: 100~240VAC; 50/60Hz
Power consumption: 1.2W (18mA@230V)
Resistive load: 250VAC/ 16A
Inductive load: 220VAC/ 8A
USB output: 5VDC/ 1A
Relay lifetime: 100,000 times
Up to 150 meters wireless transmission range in non-obstacle space
Easy installation and configuration
4. Installation
This device is NOT truly waterproof/ resistant and is for indoor use.
Power on Z803 using 100~240 VAC power supply.
5. Setting up Z803
5-1. Join the ZigBee Network
After Z803 is turned on, it will search for an existing ZigBee network and send a request to join the network
automatically. While Z803 is under the coverage from a coordinator or a router whose permit-join feature is
enabled, Z803 will be permitted to join the network.
Before Z803 is joined a ZigBee network → the icon will keep flashing.
After Z803 has joined a ZigBee network → the icon will stay on. The LCD displays the data

5
of power consumption such as .
5-2. Binding
Z803 can be bound with the device which supports On/Off cluster.
Step1. Press and hold the Bind Key for 3 seconds.
Step2. Release the Bind Key when the LCD flashes once.
Step3. Within 5 seconds, press the switch button of the socket which you would like to bind to broadcast
the binding request. The LCD will show .
Step4. The LCD display shows after the binding is completed; otherwise,
it will show .
5-3. Permit-Join
Z803 is designed to work as a router. To allow other devices to join the ZigBee network, users could enable
the Permit-Join feature using the tips:
A. Press the Bind Key to enable the Permit-Join feature. The LCD will display
for 10 seconds, and the icon will be flashing.
B. The default Permit-Join period of time is 60 seconds.
C. Under the circumstances Permit-Join feature is turned on, users can press the Bind key to turn off the
Permit-Join feature.

6
5-4. Identification
According to the received Identify Times, the LCD display will flash N times (N =
Identify Times).
5-5. LCD Display
Users could use the Match key to switch the readings of Voltage (V) → Current (A) → Power (W) → Energy
(kWh). For example, shows the voltage readings.
5-6. Reset Power Consumption Summation
To reset the power consumption data, please follow the steps:
Step1. Press and hold the Bind Key for 20 seconds. The icon will flash 4 times (at the 3rd, the 10th,
the 15th, and the 20th second).
Step2. After releasing the Bind Key, press the Match Key within 2 seconds to complete the reset.
5-7. Restore to Factory Setting
To restore it to factory setting, please follow the steps:
Step1. Press and hold the Bind Key for 15 seconds. The icon will flash 3 times (at the 3rd, the 10th,
and the 15th second).
Step2. After releasing the Bind Key, press the Match Key within 2 seconds to complete the restore.

7
6. Home Automation Clusters for Z803
A cluster is a set of related attributes and commands which are grouped together to provide a specific function. A
simple example of a cluster would be the On/Off cluster which defines how an on/off switch behaves. This table
lists the clusters which are supported by Z803.
Information attribute set
Identifier Name Type Range Access Default Mandatory
/ Optional
0x0000 ZCLVersion 8-bit
Unsigned
integer
0x00 –0xff Read
only
0x03 M
Cluster ID for Z803
Server side Client side
EP 0x01~0x04 ( OnOff Output)
Basic(0x0000)None
Identify (0x0003)
Groups (0x0004)
Scenes (0x0005)
On/Off (0x0006)
Commissioning(0x0015)
Simple Metering(0x0702)
Electrical Measurement (0x0B04)
Diagnostics(0x0B05)
Cluster ID for Z803
Server side Client side
EP 0x05 ( Consumption Awareness )
Basic(0x0000)None
Identify (0x0003)
Commissioning(0x0015)
Simple Metering(0x0702)
Electrical Measurement (0x0B04)
Diagnostics(0x0B05)

8
Identifier Name Type Range Access Default Mandatory
/ Optional
0x0001 ApplicationVersion 8-bit
Unsigned
integer
0x00 –0xff Read
only
0x1E O
0x0002 StackVersion 8-bit
Unsigned
integer
0x00 –0xff Read
only
0x35 O
0x0003 HWVersion 8-bit
Unsigned
integer
0x00 –0xff Read
only
0x0B O
0x0004 ManufacturerName Character
string
0 – 32 Bytes Read
only
netvox O
0x0005 ModelIdentifier Character
string
0 – 32bytes Read
only
Z803E3R O
0x0006 DateCode Character
string
0 – 16 bytes Read
only
20141128 O
0x0007 PowerSource 8-bit
Enumeration
0x00 –0xff Read
only
0x01 M
0x0010 LocationDescription Character
string
0 – 16bytes Read/wr
ite
Empty
string
O
0x0011 PhysicalEnvironmen
t
8-bit
Enumeration
0x00 –0xff Read/wr
ite
0x00 O
0x0012 DeviceEnabled Boolean 0x00–0x01 Read/wr
ite
0x01 O
Use Cluster ID(0x0702)in Simple Metering of SE and Cluster ID(0x0B04)of Electrical Measurement. In
Cluster ID(0x0702), Netvox defined attributes are as below:
The related Cluster ID:
Simple Metering Cluster ID (0x0702)
Electrical Measurement Cluster ID (0x0B04)
The related Attribute ID of Simple Metering Cluster ID (0x0702):
Current Attribute ID: 0xE000; unit: mA
Voltage Attribute ID: 0xE001; unit: V
Power Attribute ID: 0xE002; unit: W
Energy Attribute ID: 0xE003; related to AttributeID CurrentSummationDeliver (0x0000); unit: Wh
The related Attribute ID of Electrical Measurement Cluster ID (0x0B04):
Current Attribute ID: 0x0508
Voltage Attribute ID: 0x0505
Power Attribute ID: 0x050B
Power Factor Attribute ID: 0x0510

9
7. Important Maintenance Instructions
Please keep the device in a dry place. Precipitation, humidity, and all types of liquids or moisture can contain
minerals that corrode electronic circuits. In cases of accidental liquid spills to a device, please leave the device
dry properly before storing or using.
Do not use or store the device in dusty or dirty areas.
Do not use or store the device in extremely hot temperatures. High temperatures may damage the device or
battery.
Do not use or store the device in extremely cold temperatures. When the device warms to its normal
temperature, moisture can form inside the device and damage the device or battery.
Do not drop, knock, or shake the device. Rough handling would break it.
Do not use strong chemicals or washing to clean the device.
Do not paint the device. Paint would cause improper operation.
Handle your device, battery, and accessories with care. The suggestions above help you keep your device
operational. For damaged device, please contact the authorized service center in your area.
Table of contents
Popular Power Strip manuals by other brands

Sygonix
Sygonix 2269127 operating instructions

Hama
Hama P2223771 operating instructions

Steren
Steren 905-210 instruction manual

AmazonBasics
AmazonBasics B07SNKGMVP quick start guide

Middle Atlantic Products
Middle Atlantic Products PDT Series instruction sheet

compulocks
compulocks SPWSB Assembly instructions