MAN-0803-1298-1 Product Manual: DQ94 2
Menu Items
You step through the various menu items by using the and keys, if you step past the last item
then you’ll simply wrap around to the first (a short beep occurs when this happens).
You change a menu item’s setting by using the SELECT key.
If no key is touched during a 2 minute period the unit will time-out and revert back to its normal operating
mode, any configuration changes are discarded.
The default settings can be loaded by holding down the SELECT key for 4 seconds, after which the factory
set defaults will be restored.
Exiting Set-up Mode
Tap either STORE or CANCEL, the latter will discard any changes and revert back to the original settings.
Setting the Default Layout
Before executing the above set-up procedure - first select your preferred split-screen layout (see section
Operation), completion of the set-up procedure results in this layout being stored as the new default.
Subsequently this layout will automatically be selected at power-up.
Description of Each Menu Item
Alert Period
4, 8, 10, 20, 30, 40, 60, 120 seconds defines the length of an alert in response to an alarm event.
Alarm Type
Normally Open alarm contacts are of type: ‘Normally Open’
Normally Closed alarm contacts are of type: ‘Normally Closed’
Main Output
Split-Screen Alert split-screen is displayed during an alert; the border of alarmed
segments flash; returns to original state when alert ends.
Full-Screen Alert alarmed cameras displayed full-screen during an alert; the
most recently alarmed camera will be displayed; returns to its
original state when alert ends.
Ignore Alerts alarms are ignored.
Auxiliary Output
Full-Screen Alert alarmed cameras are displayed full-screen during an alert; the
most recently alarmed camera will be displayed; returns to
split-screen display when alert ends.
Always Sequencing full-screen sequencing of cameras; missing cameras are
skipped; alarms are ignored.
Always Split-Screen split-screen is displayed, alarms are ignored.
Auxiliary Sequence Period
4, 8, 10, 20, 30, 40, 60, 120 seconds defines the dwell period for the auxiliary channel’s auto-
sequencer; this is only relevant if ‘Auxiliary Output’ behaviour
is set to ‘Always Sequencing’.
Sound During Alert
Yes / No defines whether beep tones are made at the start of an alert.
Flash Borders
Yes / No defines whether segment borders are flashed when alarmed.
Show Identifiers
Yes / No defines whether camera identifiers are displayed in each
segment of the split-screen display.
Lock Layout
Yes / No when set to YES the layout is locked into the ‘classic’ quad
style; when set to NO the operator is allowed to select the
layout via the keyboard.