North Storm NS-8W-WAC WIFI User manual

NS-8W-WAC WIFI
NS-12W-WAC WIFI
NORTH STORM


INTRODUCTION
IMPORTANT SAFETY INSTRUCTION ...........................................................................
...................................................................................
PACKING LIST ............................................................................................................
INSTALLATION & ASSEMBLY INSTRUCTIONS ..............................................................
USING YOUR AIR CONDITIONER ................................................................................
........................................................................
CARE AND CLEANING ................................................................................................
TROUBLESHOOTING .................................................................................................
ELECTRICAL REQUIREMENTS
OPERATING YOUR AIR CONDITIONER
1
2
3
4
9
11
12
13

1

2
(6K-8K) 0-8 amps
(10K-12K) 0-12 amps
(6K-8K) 10-amp
(10K-12K) 15-amp

3
TWC-06CR/UH (ES) & TWC-08CR/UH (ES)

4
FIG. 1
FIG. 2
0
8
OFFSET
STOOL
SILL
INTERIOR
WALL
EXTERIOR
WALL
OFFSET
STOOL
SILL
INTERIOR
WALL
EXTERIOR
WALL

5
(Only used for 6K/8K)

6
FIG. 3
3
FIG. 4
FIG. 5
REWORD: Top Rail and Sliding Panels at each side
are offset to provide the proper pitch of 5/16" to the
rear of the air conditioner.

7
(It is suggested to keep a downward
angle so accumulated rain water can drain out from the
backside of the unit.)
FIG. 6
FIG. 7
FIG. 8
FIG. 9
FIG. 10
FIG. 11
FIG. 12
FIG. 13
Keeping

8
FIG. 14

9
Use these buttons on the control
panel and remote to set the Timer.
Timer Off: The timed stop is programmed by
pressing TIMER button. Set the rest time by
pressing the button or until the rest
time displayed is to your then press TIMER
button again.
Timer On: When the unit is off, press TIMER
button , set the temperature with
pressing the button or . Press TIMER
button , set the rest time with
pressing the button or . Press TIMER
button , confirm the setting, then
Note:It can be set to automatically turn off or on in
0.5-24 . Each press of the
buttons will increase or decrease the timer.
The Timer can be set in 0.5 hours increment below
10 hours and 1 hour increment for 10 hours or
above.
The SET light will turn on while setting.
To cancel the function, press the TIMER button
again.
liking
a second time
lliwemitdrihta
automatically switch on and will show on the display.
hour increments
set
5. Timer Button:
Cool Mode: The cooling function allows the air
conditioner to cool the room and
. Press the MODE
button to activate the cooling function. To optimize
the function of the air conditioner, adjust the
temperature and the speed by pressing the button
indicated.
Dry Mode: This function reduces the humidity of
the air to make the room more comfortable. Press
MODE button to set the DRY mode. An automatic
function of alternating cooling cycles and air fan
is activated.
Fan Mode:
Press MODE button to set
the FAN mode. With pressing FAN SPEED button
the speed changes in the following sequence: Hi,
Med and Lo in FAN mode. The remote control also
the speed that was set in the previous mode
of operation.
Auto Mode:In AUTO mode the unit automatically
chooses the fan speed and the mode of operation
(COOL,DRY or FAN).In this mode the fan speed
and the temperature are set automatically
according to the room temperature (tested by
the temperature sensor which is incorporated
in the indoor unit.).
and reduces the
air humidity at the same time
This function works only when the air
conditioner is ventilated.
stores
1. When the timer is not in use,
the operation mode and the set temperature will
be display. Time will be displayed under the timer
setting.
Digital Display:
and Button:2. Use these buttons on the
control panel and remote to increase or decrease
the Set Temperature or Timer.
Temperature range: 61 ~88 or 16 ~31 .
3. Turn the air conditioner on and
off.
Power Button:
Press the mode button to cycle
through the various modes: Cool, Dry, Fan and
Auto.
4. Mode Button:
1
2
3
456789
AUTO
SPEED
AUTO
MODE
WIFI
WIFI Symbol*
NOTE: * means only available for WIFI modes, For more
information, please see the WIFI manual.
NORTH STORM

10
Press the SLEEP button, the Sleep
Light will be on , and
In SLEEP mode, the air-
conditioner will automatically adjust the tempera-
ture and fan speed to make the room more comfor-
table during the night. The set temperature will
automatically raise by 1 every 30-60 minutes
and at most change six times until the set
temperature is .
for 10 seconds then all of the
display lights will turn off.
.8
82.4
7. Sleep Button:
Press the FAN SPEED button
to choose the fan speed options. You can choose
Hi, Med, Lo or auto speed in COOL mode
choose Hi, Med, Lo in FAN mode.
or
8. Fan Speed Button:
9. When the Filter Check light is off,
it is to press the Filter Check button.
When the Filter Check light is on, can turn off
the light by pressing the Filter Check button. After
the fan motor works for 500 total hours, the Filter
Check light will turn on to remind the user to clean
the filter.
not necessary
you
Filter Button:
horizontal wheel rotcelfedriarotcelfedria
When the unit is in ECO mode, the
light will turn on. In ECO mode, the unit will
turn off once the room is cooled to the user set
temperature. Fan will also be off at this point.
The unit will turn back on when the room
temperature rises above the user set temperature.
Before the compressor ,
startsthe fan motor will
run for a while, then it will stop for a while, and will
repeat to provide a much more comfortable feeling
and save energy.
6. Eco Button:10.To direct the airflow, use the
horizontal wheel to control the horizontal direction
and use the air deflectors to control the vertical
direction.
Directional Louvers:

11
Press the SLEEP button, the Sleep
Light will be on , and
In SLEEP mode, the air-
conditioner will automatically adjust the tempera-
ture and fan speed to make the room more comfor-
table during the night. The set temperature will
automatically raise by 1 every 30-60 minutes
and at most change six times until the set
temperature is .
for 10 secondsthen all of the
display lights will turn off.
.8
82.4
4. Sleep:
1. the air conditioner on and off.TurnsPower:
2. Press the COOL button to COOL mode.Cool:
and :3. Use these buttons on the control
panel and remote to increase or decrease the
Set Temperature or Timer. Temperature range:
61 ~88 or 16 ~31 .
1
4
5
6
3
3
7
8
10
9
Fan Only:
Press the FAN SPEED button to
choose the fan speed options. You can choose
Hi, Med, Lo or auto speed in COOL mode and
Hi, Med, Lo in FAN mode.
7. Fan Speed:
By pressing the DISPLAY button, it will switch
off/on all lights on the LED display.
8. Display:
Use these buttons on the control panel
and remote to set the Timer.
Timer Off: The timed stop is programmed by
pressing TIMER button. Set the rest time by
pressing the button or until the rest
time displayed is to your then press
TIMER button again.
Timer On: When the unit is off, press TIMER
button first time, set the temperature with
pressing the button or . Press TIMER
button a second time, set the rest time with
pressing the button or . Press TIMER
button a third time, confirm the setting, then
Note:It can be set to automatically turn off or on
in 0.5-24 hours. Each press of the
buttons will increase or decrease the timer. The
Timer can be set in 0.5 hours increment below
10 hours and 1 hour increment for 10 hours or
above. The SET light will turn on while setting.
To cancel the function, press the TIMER
button again.
liking
a
will
automatically switch on and will show on the display.
set
5. Timer:
In AUTO mode the unit automatically
chooses the fan speed and the mode of operation
(COOL,DRY or FAN).In this mode the fan speed
and the temperature are set automatically according
to the room temperature (tested by the temperature
sensor which is incorporated in the indoor unit.).
6. Auto Mode:
2
When the unit is in ECO mode, the
light will turn on. In ECO mode, the unit will
turn off once the room is cooled to the user set
temperature. Fan will also be off at this point.
The unit will turn back on when the room
temperature rises above the user set temperature.
Before the compressor ,
startsthe fan motor will
run for a while, then it will stop for a while, and will
repeat to provide a much more comfortable feeling
and save energy.
Press the Fan Only button to
FAN ONLY mode.
switch to
9.
10.
Eco:

12
FIG. 15
15

13

14

NORTH STORM
Repairs must be carried out by authorized specialists to
ensure electrical safety. Please contact the service agent or a
suitably qualied electrician.
Improper repairs could lead to danger. The warranty does not
cover damage or failure that results from alteration, accident,
misuse, abuse, neglect or improper maintenance.
Due to ongoing product development we reserve the right to
change the product specications and documentation with-
out notice.
For more information:
ENERGYWISE SOLUTIONS
700 W 1700 S Suite 111
LOGAN, UT 84323
435-752-6611
northstorm.com

NS-8W-WAC WIFI
NS-12W-WAC WIFI
Modelos
Acondicionador de aire de ventana electrónica
Instrucciones de funcionamiento
NORTH STORM

This manual suits for next models
1
Table of contents
Languages:
Other North Storm Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual