NRD Ionmaster 6214 Instruction manual

Installation / Operation / Maintenance
Ionmaster®Ionizing Fan (with heater)
Model 6214
NRD, LLC / 2937 Alt Boulevard / Grand Island, NY 14072
PHONE 716 773 7634 / FAX 716 773 7744 / EMAIL sales@nrdllc.com / WEB www.nrdllc.com
NRD Asia Pte. Ltd
PHONE +65 6679 1707 / EMAIL sales@NRDasia.com / WEB www.nrdllc.com
INST6214 – 1/23
Overview
The
Ionmaster®Ionizing Fan M/N:6214
generates AC high
voltage, producing balanced ionized airflow to eliminate
static charges on target work surfaces. The unit can be placed
at one end of the workbench, or mounted on the wall or shelf,
and directed at the target
or area to be neutralized. The
ionizer
is designed to neutralize charge on a target
located one to
four feet in front of the unit. Discharge time increases with
distance from the unit.
General Guidelines
•Keep water, oil, contamination and any
fluids away
from the blower at all times
•Keep the unit clean internally and externally
for
optimal performance
Contents
Remove the ionizer from the carton and inspect for damage.
Included with the unit should be:
•One (1) Ionmaster®Ionizing Fan with stand and
adjustment knobs installed
•One (1)
Detachable NEMA/IEC power cord (120V)
•One (1) Round foam air filter with one (1) snap-on
retainer
•This IOM (installation, operation, mainte-
nance) instructions manual
Caution! Disconnect the unit from power before per-
forming any maintenance, inspection or cleaning to
avoid an electrical shock hazard and to prevent dam-
age to the unit!

Installation / Operation / Maintenance
Ionmaster®Ionizing Fan (with heater)
Model 6214
NRD, LLC / 2937 Alt Boulevard / Grand Island, NY 14072
PHONE 716 773 7634 / FAX 716 773 7744 / EMAIL sales@nrdllc.com / WEB www.nrdllc.com
NRD Asia Pte. Ltd
PHONE +65 6679 1707 / EMAIL sales@NRDasia.com / WEB www.nrdllc.com
INST6214 – 1/23
Installation
1.
Locate the Ionmaster®M/N:6214:
•12” to 48” from the target to be neutralized for
optimal performance, making sure that the airflow
will not be restricted.
•A working electrical outlet within reach of the 6
’ long
detachable cord that is supplied with the Ionmaster®
M/N:6214.
2.
The Ionmaster®M/N:6214 can be installed in two dif-
ferent ways:
•Placed or secured on a flat surface such as a bench
top
. The unit comes with a stand so that it can be po-
sitioned on the work surface, aimed at the target and
adjusted for inclination and locked in place with the
lock knobs.
•It can also be wall or shelf mounted to keep valuable
bench space free for other purposes and equipment.
3.
Connect the barrel plug of the AC adapter to the re-
ceptacle in the back of the Iommaster®M/N:6214.
4.
Connect the AC adapter to a 1
20 VAC, 60 Hz electrical
outlet which is properly grounded. Ensure the unit
Power Switch is in the off position before plugging in.
Important Note: Before powering up the ionizer,
verify that the AC outlet is properly grounded and
that the supplied line voltage matches the electrical
specifications on the rear panel of the unit. Plugging
the ionizer into an outlet with the incorrect voltage
may damage the unit and will void any warranty
coverage.
Operation
1.
To turn the ionizer ON press the red POWER switch,
located on the lower right front panel of the unit. The
POWER switch will illuminate when the ionizer is run-
ning.
2.
To change the ionizer speed, use the FAN switch to se-
lect HI or LOW fan speed located next to the POWER
switch.
3.
Adjust the ionizer to direct the airflow into the work
area.
4.
If heating is desired for operator comfort this can be
turned on by turning the HEATER switch to the ON
position. Heater can be used in HI or LOW fan speed.
Maintenance
There are no user serviceable parts INSIDE this
ionizer. DO NOT remove front panel, or back
chrome finger guard.
Under normal operating conditions the ionizer will at-
tract dirt and dust, especially on the emitter pins, and
filter. To maintain optimum neutralization efficiency
and operation, cleaning should be performed on a reg-
ular basis.
Emitter Point Cleaning:
1. To clean the emitter points rotate the cleaning brush
clockwise and allow spring to return brush counter-
clockwise. Knob is located on the front of the ionizer
and labeled Point Cleaner.
2. Repeat step 1 several times for sufficient cleaning of
emitter points.
Filter Cleaning:
1. If foam filter on back of ionizer becomes dirty,
carefully unsnap white plastic retainer ring holding the
foam in place.
2. Clean foam filter with soap and water. Allow filter to
dry completely before re-installing.
3. Push filter into white pla
stic retainer ring and snap onto
chrome finger guard…be sure to line up cutouts and
push until it snaps in place.
Fuse Replacement:
1. In the event that the power input fuse blows and needs
replacing. UNPLUG THE UNIT PRIOR TO
REPLACING FUSE
2. Remove the power cable from the back of the ionizer
3. Using a small screwdriver pry open the fuse drawer lo-
cated below the power cable input jack. Carefully
remove the fuse drawer and fuse replace with
Fuse type: GMA 5A 250V
(20mm length x 5mm diameter)
4. Re-install fuse drawer and snap
fuse into place. Check ionizer
for proper operation.

Installation / Operation / Maintenance
Ionmaster®Ionizing Fan (with heater)
Model 6214
NRD, LLC / 2937 Alt Boulevard / Grand Island, NY 14072
PHONE 716 773 7634 / FAX 716 773 7744 / EMAIL sales@nrdllc.com / WEB www.nrdllc.com
NRD Asia Pte. Ltd
PHONE +65 6679 1707 / EMAIL sales@NRDasia.com / WEB www.nrdllc.com
INST6214 – 1/23
Specifications:
•
Input Voltage, Frequency: 120Vac, 60Hz
•
Input Current: 1.9A (heater ON, fan HIGH)
1.8A (heater ON, fan LOW)
0.3A (heater OFF, fan HIGH)
0.2A (heater OFF, fan LOW)
•
Air Velocity
(on fan
-center axis): 600 FPM (fan HIGH, 1ft.)
420 FPM (fan LOW, 1ft.)
•
Air Delivery Rate: 76 CFM (fan HIGH)
52 CFM (fan LOW)
•
Ionization Balance: ±10V typical
•
Ionization Emitter: Radial configuration, 10 stainless
steel emitter points with fine-ground terminal radius.
•
Heated Air: 15°F rise above ambient (fan LOW, 6in)
8°F rise above ambient (fan HIGH, 12in)
•
Input Fuse: 5A slow-blow (fuse holder in AC inlet)
•
Chassis: Steel enclosure, powder coated epoxy/polyester
paint finish
•Air Filter: Open-
cell polyurethane foam (30 pores per in)
•Ozone: 0/01ppm (fan LOW, 6in)
•Audible Noise: 54dBA SPL (fan LOW, 1ft)
61dBA SPL (fan HIGH, 1 ft)
•Weight: 7.1 pounds (without power cord)
•Dimensions
(with
stand, tilt lock knobs): 9in (height)
7.5in (width)
5.25 in (depth)
•Mounting: Benchtop tilt-adjust stand with locking
knobs, black polymer feet; can also be
wall-mounted or shelf-mounted using slots
in stand and 2 screws (1/4 in thread diam.)

Installation / Operation / Maintenance
Ionmaster®Ionizing Fan (with heater)
Model 6214
NRD, LLC / 2937 Alt Boulevard / Grand Island, NY 14072
PHONE 716 773 7634 / FAX 716 773 7744 / EMAIL sales@nrdllc.com / WEB www.nrdllc.com
NRD Asia Pte. Ltd
PHONE +65 6679 1707 / EMAIL sales@NRDasia.com / WEB www.nrdllc.com
INST6214 – 1/23

Installation / Operation / Maintenance
Ionmaster®Ionizing Fan (with heater)
Model 6214
NRD, LLC / 2937 Alt Boulevard / Grand Island, NY 14072
PHONE 716 773 7634 / FAX 716 773 7744 / EMAIL sales@nrdllc.com / WEB www.nrdllc.com
NRD Asia Pte. Ltd
PHONE +65 6679 1707 / EMAIL sales@NRDasia.com / WEB www.nrdllc.com
INST6214 – 1/23
Trouble Shooting Guide
Symptom
Probable Cause
Corrective Action
1. Static charges are not elimi-
nated.
-Dirty emitter pins.
Clean emitter pins using rotating
brush.
2. Fan inoperative
-Loss of power to outlet or ionizer.
-Blown input fuse
-Check electrical connections (cord
into ionizer), and outlet power (12
0VAC).
-Check input fuse and replace if neces-
sary.
Limited Warranty
NRD expressly warrants that for a period of one (1) year
from the time of purchase, the
ionizer will be free of defects
in material (parts) and workmanship (labor). Within the
warranty period, the
ionizer will be tested, repaired, or re-
placed at discretion of NRD, free of charge. Any
ionizer
under warranty should be shipped prepaid to the NRD fac-
tory. Call Customer Se
rvice at (716) 773-7634 for a Return
Authorization
Number and shipping instructions. Include a
copy of your original packing slip, invoice, or other proof of
purchase date.
If the
ionizer is out of warranty, NRD LLC will quote repair
charges
necessary to bring your ionizer up to factory stand-
ards.
Warranty Exclusions
The forgoing express warranty is made in lieu of all other
product warranties, expressed and implied, including mer-
chantability and fitness for a particular purpose that is
specifically disclaimed. The express warranty will not apply
to defects or damage due to accidents, neglect, misuse, alter-
ations, operator error, or failure to properly maintain, clean
or repair products.
Limit of Liability
The user shall determine the
suitability of the product for
their intended use, and the user assumes all risk and liability
whatsoever in connection therein.
Table of contents
Other NRD Fan manuals
Popular Fan manuals by other brands

Bayside
Bayside CALYPSO Installation, operation, maintenance & warranty information

Goldair
Goldair GCPF340 operating instructions

EUROM
EUROM MILANO de LUXE manual

Home Decorators Collection
Home Decorators Collection CIRINO AM550-BN Use and care guide

HOMCOM
HOMCOM 820-298V90 manual

Panasonic
Panasonic F-M15G2 Operating and installation instructions