NRD Corona Staticmaster 6220 Owner's manual

NRD USA / 2937 Alt Boulevard / PO Box 310 / Grand Island, NY 14072-0310
PHONE7167737634/FAX7167737744/EMAIL[email protected]/WEBwww.nrdllc.com
NRDAsiaPte.Ltd/114LavenderStreet#08‐90CTHub2Singapore338729
PHONE+6566791707/EMAIL[email protected]/WEBwww.nrdllc.com
- 1 -
INST6220_05/18
Installation / Operation / Maintenance
Corona Staticmaster®Overhead Ionizing Fan
Model 6220
(Auto-Balanced Ionization System)
Contents
Precautions
1. Features and Descriptions
2. Installation
3. FMS Connection
4. Maintenance
5. Specifications
6. Dimensions
7. Warranty
2
2
3
4
4
5
6
6

NRD USA / 2937 Alt Boulevard / PO Box 310 / Grand Island, NY 14072-0310
PHONE7167737634/FAX7167737744/EMAIL[email protected]/WEBwww.nrdllc.com
NRDAsiaPte.Ltd/114LavenderStreet#08‐90CTHub2Singapore338729
PHONE+6566791707/EMAIL[email protected]/WEBwww.nrdllc.com
- 2 -
INST6220_05/18
Please Observe The Following
NOTICE
Please review the information in this manual prior to installing and operating the ionizer in a work environment.
NOTICE
Please keep this document in a convenient place to refer to as a guide.
WARNING
If the Staticmaster® is used in a manner not specified in this manual, the protection provided by its design may be
impaired.
WARNING
This product is designed to be used by manufacturers for electronic industry applications and generates high voltage.
Do not open and modify it, or operate without being completely assembled. High voltage internal parts can cause
electrical shock.
WARNING
Before performing maintenance, turn the Staticmaster® off, disconnect from the power source, and do not wear a
wrist strap. High voltage internal parts can cause electrical shock.
WARNING
Do not use this product in a flammable atmosphere.
WARNING
Do not submerge in water. If liquid enters product, disconnect power cord and allow to thoroughly dry before using
again.
WARNING
If there is any damage on power cable or communication cable, replace these prior to use.
WARNING
This product will generate ozone along with ions, if the user smells ozone, please refresh the air in working
environment.
1. Features and Descriptions
1-1. Features
Model 6220 Power cord Optional Remote Control

NRD USA / 2937 Alt Boulevard / PO Box 310 / Grand Island, NY 14072-0310
PHONE7167737634/FAX7167737744/EMAIL[email protected]/WEBwww.nrdllc.com
NRDAsiaPte.Ltd/114LavenderStreet#08‐90CTHub2Singapore338729
PHONE+6566791707/EMAIL[email protected]/WEBwww.nrdllc.com
- 3 -
INST6220_05/18
1-2. Descriptions
1. AC Power Terminal – 110~240V AC power connects from process tool when possible.
2. ON/OFF Switch - Power ON/OFF Switch.
3. Fan Speed Control – Select from low, medium, and high fan speed.
4. FMS (Facility Monitoring System) - FMS will allow you to monitor the status of ionizers and alarm connection.
5. Bracket – Refer to section 8 for dimensions.
6. Fan Speed Indication LED – 1 LED: Low speed, 2 LEDs: Medium speed, 3 LEDs High speed.
7. IR Receiver – for optional Remote Control.
8. LED Indicator for Operation and Alarm.
9. Fan Filter Grill.
10. Fan Filter Grill Hook.
11. Fan Operation Sensor Hole.
2. Installation
2-1. Locate the Staticmaster®:
12” (300mm) to 48” (1200mm) from the target to be neutralized for optimal performance, making sure that
the airflow will not be restricted.
A working electrical outlet within reach of the 6’ (1800mm) long detachable cord that is supplied with the
Staticmaster®.
2-2. The Staticmaster® should be installed directly above the target area to be neutralized.
2-3. Power Connection
Connect the power cord to the AC power terminal on the end of the Staticmaster®.
Plug the power cord into a 120 VAC, 60 Hz electrical outlet.
2-4. Turn the Staticmaster® “ON”.
2-5. Adjust the Staticmaster® fan speed to achieve the desired airflow on the work area.
13 24
5
6
78
9
11
10

NRD USA / 2937 Alt Boulevard / PO Box 310 / Grand Island, NY 14072-0310
PHONE7167737634/FAX7167737744/EMAIL[email protected]/WEBwww.nrdllc.com
NRDAsiaPte.Ltd/114LavenderStreet#08‐90CTHub2Singapore338729
PHONE+6566791707/EMAIL[email protected]/WEBwww.nrdllc.com
- 4 -
INST6220_05/18
3. FMS Connection
3-1 . Interface Terminal Connection
Pin No. Description Facility Monitoring System Output Signal
FMS 1 Alarm signal relay output Condition FMS 1~2 FMS 4~5 FMS 3~6
FMS 2 Alarm relay common Normal state Open 4~5mA Open
FMS 3 Out of balance signal relay output Alarm State Closed 17~20mA Closed
FMS 4 Current output for each operation No Power Closed 0mA Closed
FMS 5 Reference ground for current output
FMS 6 Out of balance relay common
3-2. Interface Terminal Cabling
4. Maintenance
NOTE: Turn power off prior to doing regular maintenance or emitter point cleaning.
4-1. Filter Cover Attach and Release
Press down, on tabs, at the top of the filter cover and release or attach it on the main enclosure.
4-2. Emitter Point Cleaning
Remove filter cover from top panel of main enclosure.
Clean emitter points using cotton swab with DI water or Isopropyl Alcohol. Caution, emitter points are
very sharp.
After cleaning, make sure ionizer is dry before turning power on.
If there is any damage or excessive wear on the emitter point, it is recommended to replace it.
NOTE: Cleaning requirements of emitter points will vary based on operating environment and use.
Recommended cleaning interval is once a month to once every other month.

NRD USA / 2937 Alt Boulevard / PO Box 310 / Grand Island, NY 14072-0310
PHONE7167737634/FAX7167737744/EMAIL[email protected]/WEBwww.nrdllc.com
NRDAsiaPte.Ltd/114LavenderStreet#08‐90CTHub2Singapore338729
PHONE+6566791707/EMAIL[email protected]/WEBwww.nrdllc.com
- 5 -
INST6220_05/18
4-3. Filter Cover Cleaning
Remove filter cover from top panel of main enclosure.
Clean filter cover with water or compressed air.
After cleaning, make sure ionizer is dry before turning power on.
If there is any damage on the filter cover, it is recommended to replace it.
4-4. Emitter Point Replacement
Remove filter cover from top panel of main enclosure.
Remove emitter points from sockets by gently pulling out toward the middle of the ionizer. Caution,
emitter points are very sharp, using tweezers or pliers is acceptable.
Insert new emitter points into sockets by gently pushing in as far as it will go. Caution, emitter points are
very sharp, using tweezers or pliers is acceptable.
NOTE: Emitter point useful life also varies based on operating environment and use. Recommended
replacement interval is once a year to once every other year.
5. Specification
Input Voltage 110 ~ 240V AC
Ion Emission Steady-State DC Technology
Balance < ±20V
Discharge less than 2 seconds per ANSI/ESD STM3.1
3 Step Fan Speed Adjustment
Air flow 27 ~ 100 CFM
Emitter Point Tungsten 99.99%
Alarm Function Audio/LED Alarm at HV Power failure
Output Monitoring FMS Interface
Material ABS for Ionizer Enclosures and Brackets
Operating Environment Temperature: 15~35 ℃
Relative Humidity: 35~75%
Dimensions (W×H×D) 4.7” x 7.1” x 39.4” (118×180×1000 mm)
Weight 7.9 lbs. (3.6 kg)

NRD USA / 2937 Alt Boulevard / PO Box 310 / Grand Island, NY 14072-0310
PHONE7167737634/FAX7167737744/EMAIL[email protected]/WEBwww.nrdllc.com
NRDAsiaPte.Ltd/114LavenderStreet#08‐90CTHub2Singapore338729
PHONE+6566791707/EMAIL[email protected]/WEBwww.nrdllc.com
- 6 -
INST6220_05/18
6. Dimensions
7. Warranty
Limited Warranty
N
RD expressly warrants that for a period of one (1) year
from the time of purchase, the ionizer will be free of
defects in material (parts) and workmanship (labor).
Within the warranty period, the Ionizer will be tested,
repaired, or replaced at discretion of NRD, free of
charge. Any ionizer under warranty should be shipped
prepaid to the NRD factory. Call Customer Service at
(716) 773-7634 for a Return Authorization number and
shipping instructions. Include a copy of your original
packing slip, invoice, or other proof of purchase date.
If the ionizer is out of warranty, NRD LLC will quote
repair charges necessary to bring your ionizer up to
factory standards.
Warranty Exclusions
The forgoing express warranty is made in lieu of all
other product warranties, expressed and implied,
including merchantability and fitness for a particular
purpose that is specifically disclaimed. The express
warranty will not apply to defects or damage due to
accidents, neglect, misuse, alterations, operator error, or
failure to properly maintain, clean or repair products.
Limit of Liability
The user shall determine the suitability of the product
for their intended use, and the user assumes all risk and
liability whatsoever in connection therein.
Table of contents
Other NRD Fan manuals
Popular Fan manuals by other brands

EUROLAMP
EUROLAMP FS-10-360A instructions

Home Decorators Collection
Home Decorators Collection 1007 532 508 Use and care guide

Hunter
Hunter Eurus Owner's guide and installation manual

ERA
ERA COMFORT 4 operation instruction

OSTBERG
OSTBERG RKB EC Directions for use

Progress Lighting
Progress Lighting AirPro CALERA installation manual

Ebmpapst
Ebmpapst A3G630-AC52-58 operating instructions

Home Decorators
Home Decorators 326 960 AL14-TB Use and care guide

Water-Loo
Water-Loo LCS-F Operating and maintenance

Ebmpapst
Ebmpapst A2S130-AB03-15 operating instructions

Ebmpapst
Ebmpapst W2S130-AB25-10 operating instructions

Black & Decker
Black & Decker BXEFD41E Original instructions