NZR ZMZ 0215 User manual

Nordwestdeutsche
Zählerrevision
Kurzanleitung/Manual/Description/Istruzioni
ZMZ 0205 / ZMZ 0215
WWW.NZR.DE
Nordwestdeutsche Zählerrevision | Ing. Aug. Knemeyer GmbH & Co. KG
Heideweg 33 | 49196 Bad Laer | Germany | Tel. +49 (0)5424 2928-0 | Fax +49 (0)5424 2928-77
DEU
ENG
FRA
ITA
Stand: 02/2013

NZR – Ihr Partner für Energiemessung
Technische Änderungen vorbehalten. -Technical details subject to charge. - Modification techniques réservées. - Riserva di modifiche tecniche.
2
Inhalt / Directory / Sommaire / Indice
ZMZ 0205 / ZMZ 0215
Deutsch
1. Montage / Sicherheit .................................................................................................................................... 3
2. Bedienungsanleitung ZMZ 0205
2.1 Einstellungen .................................................................................................................................................. 4
2.2 Zeiteinstellung ................................................................................................................................................ 5
2.3 Anzeige ............................................................................................................................................................... 5
3. Sonderausstattung
3.1 Münzenzählwerk (Option „A“) ..................................................................................................................... 5
4. Bedienungsanleitung ZMZ 0215
4.1 Einstellungen ................................................................................................................................................... 6
4.2 Laufzeiteinstellung ......................................................................................................................................... 6
4.3 Münzvorlage .................................................................................................................................................... 6
5. Sonderausstattung
5.1 Nachlaufzeit (Option „Q2“) .......................................................................................................................... 7
5.2 Vorlaufzeit (Option „Q1“) .............................................................................................................................. 7
5.3 Externer Start / Externer Stopp (Option „S“) ............................................................................................ 7
5.4 Türentriegelung (Option „M“) ..................................................................................................................... 7
5.5 Münzenzählwerk (Option „A“) 6-stellig ................................................................................................... 7
5.6 Betriebsstundenzähler (Option „V“) ........................................................................................................... 8
5.7 Mehrfachmünzprüfer (Option „O“) ............................................................................................................ 8
6. Technische Daten
6.1 ZMZ 0205 ........................................................................................................................................................... 8
6.2 ZMZ 0215 ........................................................................................................................................................... 8
7. Wartung ........................................................................................................................................................... 8
8. Gewährleistung .............................................................................................................................................. 8
9. Maß- und Schaltbilder ................................................................................................................................... 9
10. Optionsübersicht ........................................................................................................................................... 10
English ......................................................................................................................................... 11
Français ......................................................................................................................................... 20
Italiano ......................................................................................................................................... 29
NZR Technischer Support
Telefon +49 (0)5424 2928-0 E-Mail info@nzr.de

NZR – Ihr Partner für Energiemessung 3
Technische Änderungen vorbehalten. -Technical details subject to charge. - Modification techniques réservées. - Riserva di modifiche tecniche.
1. Montage ZMZ 0205 / ZMZ 0215
• Befestigungslöcher nach Maßskizze bohren (Abb.6 - Maß- und Schaltbilder)
• Nach Öffnen des Gerätes und Entfernen der Anschlussabdeckkappe kann das Gerät
mit den bei liegenden Schrauben an der Wand befestigt werden.
• Es ist unbedingt auf senkrechten Sitz zu achten, um eine einwandfreie Funktion des
Münzprüfers zu gewährleisten.
Anschluss: Achtung! Vor dem Zugang zu den Anschlussklemmen müssen alle
Netzstromkreise abgeschaltet werden.
VDE- und örtliche Vorschriften sind zu beachten.
• Der Anschluss muss bauseits mit einem Schalter von 3 mm Kontaktunterbrechung
(Sicherung) vorgenommen werden.
• Anschlussleitungen durch die Kabeltüllen führen
• Zur leichteren Verkabelung ist der linke Teil des Steckverbinders abziehbar. Die Klem-
menbelegung ist auf der Klemmenabdeckung abgedruckt
• Anschluss gem. entsprechendem Schaltbild herstellen (Abb. 1 - 5)
• Bei Wiederaufstecken des Steckverbinders auf sicheres Einrasten achten
• Klemmenabdeckung wieder aufsetzen
ACHTUNG!
Diese Geräte sind nicht dafür bestimmt, durch Personen (einschließlich Kinder) mit
eingeschränkten physischen,sensorischen oder geistigen Fähigkeiten oder mangels Er-
fahrung und/oder mangels Wissen benutzt zu werden, es sei denn, sie werden durch eine
für ihre Sicherheit zuständige Person beaufsichtigt oder erhielten von ihr Anweisungen,
wie das Gerät zu benutzen ist.
Kinder sollten beaufsichtigt werden,um sicherzustellen, dass sie nicht mit dem Gerät
spielen.
Sicherheitshinweis:
Um Personen- und Sachschäden zu vermeiden, muss vor dem Öffnen des Gerätes (z.B. zur
Münzentleerung) gesichert sein, das keinWasser eindringen kann.
Sicherheitskleinspannung (Option „L“)
Bei Betrieb in Nassbereichen ist der Anschluss mit Sicherheitskleinspannung 24 V zu
empfehlen. Zu diesem Zweck ist eine 24 V-Wechselspannung in den Nassbereich zu führen.
Transformatoren 230V / 24 V 100 VA für bis zu 4 ZMZ- Steuerungen sind ab Werk erhältlich
Kurzanleitung
ZMZ 0205 / ZMZ 0215
DEU

NZR – Ihr Partner für Energiemessung
Technische Änderungen vorbehalten. -Technical details subject to charge. - Modification techniques réservées. - Riserva di modifiche tecniche.
4
2. Bedienungsanleitung ZMZ 0205
2.1 Einstellungen
Das Gerät ZMZ 0205 verfügt über eine 1-stel-
lige LED-Anzeige zur Angabe der Anzahl der
eingeworfenen Münzen bzw. der Restlaufzeit.
Das Gerät arbeitet mit einer Münzvorlage von
maximal zwei Münzen.
Weitere Münzeinwürfe verlängern nicht die
Restlaufzeit.
Erst nach Ablauf der Restlaufzeit kann eine
erneute Zeitfreigabe mittels Münzeinwurf erfol-
gen. Die Zeitbasis ist umstellbar von Stunden/
Minuten auf Minuten/Sekunden.
Auslieferungszustand
Brücke 1 offen
nur eine Münze wird angenommen
Brücke 2 offen
Dip oben für Minuteneinstellung
Dip unten für Stundeneinstellung
Alternativ Einstellung Leiterplatte ZMZ 0205
Brücke 1 geschlossen
Einwurf zweier Münzen möglich
Brücke 2 geschlossen
Dip-oben für Sekundeneinstellung
Dip-unten für Minuteneinstellung
Wertigkeit der Dip-Schalter:
1 – 2 – 4 – 8 – 16 – 32
Hinweis
Alle Grund- und Zeiteinstellungen werden nur wirksam, wenn nach erfolgter Einstellung
das Gerät kurz vom Netz getrennt wird. Bei der erstmaligen Inbetriebnahme erscheint
eine blinkende Folge von vier Ziffern, z.B. 0 – 1 – 0 – 2, gefolgt von einer kurzen Pause.
Diese Ziffernkombination gibt Aufschluss über die installierte Softwareversion. Das
Erscheinen der „0“ als Daueranzeige signalisiert die Betriebsbereitschaft.
Münzprüfer
Münzenzählwerk
B
1
B
2
Dip-oben
Dip-unten
124816 32

NZR – Ihr Partner für Energiemessung 5
Technische Änderungen vorbehalten. -Technical details subject to charge. - Modification techniques réservées. - Riserva di modifiche tecniche.
2.2 Zeiteinstellung
Die Einstellung der gewünschten Laufzeit wird vorgenommen, indem die auf der Leiter-
platte aufgedruckten Zahlenwerte der auf die „on“-Position verschobenen Dippschalter
addiert werden.
Beispiel: Oberer Dippschalter
Schalter 1, 3 und 4 auf „on“
Die Addition der aufgedruckten Zahlenwerte ergibt 13
Je nach Grundeinstellung (s.o.) ist so die Laufzeit auf 13 Minuten bzw. 13 Sekunden eingestellt
Unterer Dippschalter
Schalter 2 und 5 auf „on“
Die Addition der aufgedruckten Zahlenwerte ergibt 18
Durch Addition mit dem Wert des oberen Dippschalters ergibt sich eine Gesamtlaufzeit
von 18 Min. 13 Sek., bzw. 18 Std. 13 Min.
2.3 Anzeige
Nach Einwurf der ersten Münze erscheint eine „1“, nach Einwurf einer zweiten Münze
(Freigabe vorausgesetzt) eine „2“ im Display. Ist der Zeitvorrat der zweiten Münze abgear-
beitet, wechselt die Anzeige wieder auf „1“. Bei Erreichen der letzten 9 Minuten wird der
Ablauf der Restlaufzeit blinkend in Einer-Schritten zur Anzeige gebracht. Ist die einge-
stellte Laufzeit je Münze kleiner als 9 Minuten, so wird dieser Wert blinkend angezeigt.
3. Sonderausstattungen ZMZ 0205
3.1 Münzenzählwerk (Option „A“)
Bei Ausrüstung mit der Option „A“ ist an dem Haltewinkel der Abdeckhaube ein
5-/6-stelliges,mechanisches, nicht rückstellbares Zählwerk zur Registrierung aller ein-
geworfenen Münzen angebracht. Die spätere Ausrüstung mit dieser Option ist im Werk
problemlos möglich.

NZR – Ihr Partner für Energiemessung
Technische Änderungen vorbehalten. -Technical details subject to charge. - Modification techniques réservées. - Riserva di modifiche tecniche.
6
4. Bedienungsanleitung ZMZ 0215
4.1 Einstellungen
Sämtliche Einstellungen des Gerätes
werden mit den vier Tasten im
seitlichen Ausschnitt der Abdeck-
haube vorgenommen.Vor und nach
jeder Änderung der Einstellwerte
ist die Taste „Betrieb“ zu drücken.
Beim erstmaligen Drücken erscheint
die Anzeige „ Außer Betrieb“, bei
Rückkehr in den normalen Betrieb
erscheint nach dem Drücken die
Anzeige „Reset“, gefolgt von der Ver-
sionsnummer der Gerätesoftware.
Alle zu verändernden Werte können
durch mehrmaliges Drücken der
Taste „Menü“ zur Anzeige gebracht
werden.
Je nach Ausführung des Gerätes
erscheint im Display :
Münzprüfer
Prozessor
EPROM
Einstellungen
„Zeit“ (Laufzeit)
„Münzen“ (Münzvorlage)
optional „Nachlauf“ (Nachlaufzeit 2. Relais)
optional „Vorlauf“ (Einschaltverzögerung)
optional „ext. Start“ (Start durch externe Taste)
optional „ext. Stop“ (Stop durch externe Taste)
4.2 Laufzeiteinstellung
Nach Aufruf des Menüs „Zeit“ kann der Cursor (Unterstrich) mit der Taste „Auswahl“
durch mehrmaliges Drücken an die zu ändernde Stelle verschoben werden. Mit der Taste
„Ändern“ kann nun der gewünschteWert der Grundzeit in Stunden : Minuten : Sekunden
eingestellt werden. Soll keine weitere Einstellung vorgenommen werden, kann mit der
Taste „Betrieb“ in die Betriebsbereitschaft zurückgekehrt werden, mit der Taste „Menü“
wird der nächste Einstellwert aufgerufen.
4.3 Münzvorlage
Nach Aufruf des Menüs „Münzen“ kann mit der Taste „Ändern“ die Anzahl der Münzen
eingestellt werden, die eingeworfen werden müssen, um das Gerät zu starten. Weiter
wie unter Laufzeiteinstellung beschrieben.
Leiterplatte ZMZ 215

NZR – Ihr Partner für Energiemessung 7
Technische Änderungen vorbehalten. -Technical details subject to charge. - Modification techniques réservées. - Riserva di modifiche tecniche.
5. Sonderausstattungen ZMZ 0215
5.1 Nachlaufzeit
(Option “Q2“)
Nach Aufruf des Menüs „Nachlauf“ kann in der vorbeschriebene Weise die Nachlaufzeit
des zweiten Relais eingestellt werden. Der Eintrag von „0“ deaktiviert diese Funktion.
Hinweis
Das Nachlaufrelais darf nur mit der gleichen Spannung betrieben werden, mit der auch
Leiterplatte ZMZ 0215 das Hauptrelais betrieben wird !
5.2 Vorlaufzeit (Option “Q1“)
Nach Aufruf des Menüs„Vorlauf“ kann in der vorbeschriebenen Weise die Vorlaufzeit (Ein-
schaltverzögerung) eingestellt werden. Der Eintrag von„0“ deaktiviert diese Funktion.
5.3 Externer Start / Externer Stop (Option “S“)
Nach Aufruf des Menüs „ext. Start“, bzw.„ext. Stop“ kann mit der Taste „Ändern“ die
jeweilige Funktion ein-, bzw. ausgeschaltet werden. Bei Ausrüstung des Gerätes mit diesen
Optionen wird auf der Oberseite der Anschlussklemmenabdeckung eine Anschlussmöglich-
keit für den externen Taster zur Verfügung gestellt. Zu beachten ist, daß die Steuerleitung
des externen Tasters mit abgeschirmten Kabel ausgeführt wird. Eine Länge von 3m sollte
nicht überschritten werden.
5.4 Türentriegelung ( Option „M“)
Um bei elektrisch verriegelten Waschmaschinen die Tür ohne Münzeinwurf öffnen zu
können, kann das Gerät mit einer zusätzlichen Taste ausgestattet werden. Nach Ablauf
der Grundzeit kann durch Drücken der Taste eine einmalige Freischaltung für eine Minu-
te erlaubt werden, um die Waschmaschinen-, bzw. Trocknertür zu öffnen. Diese Funktion
wird im Display mit der Anzeige„Taste / Münze“ signalisiert.
5.5 Münzenzählwerk (Option „A“) 6-stellig
Nach Drücken der Tasten „Betrieb“ und„Auswahl“ kann die Anzahl der eingeworfenen
Münzen abgelesen werden:
Mz Zahl Anzahl der eingeworfenen Münzen seit der letzten Rückstellung,
bei Option „O“ der eingeworfene Geldbetrag. (Wertmarken werden nicht
aufgerechnet)
GMz Zahl Anzahl aller eingeworfenen Münzen seit Inbetriebnahme (nicht
rückstellbar), bei Option „O“ der Geldbetrag. Zwischen diesen beiden
Registern kann mit der Taste „Menü“ gewechselt werden. Die Abfrage
„Löschen?“ kann durch die Taste „Ändern“ beantwortet werden und
bezieht sich nur auf den Wert von„Mz Zahl

NZR – Ihr Partner für Energiemessung
Technische Änderungen vorbehalten. -Technical details subject to charge. - Modification techniques réservées. - Riserva di modifiche tecniche.
8
5.6 Betriebsstundenzähler (Option „V“)
Ist das Gerät mit der Sonderausstattung„V“ ausgerüstet, gilt die gleiche Vorgehensweise
wie unter Münzenzählwerk beschrieben.Zur Anzeige kommen die Register:
FSZ Freischaltzeit in Stunden seit der letzten Rückstellung
GFSZ Gesamte Freischaltzeit seit Inbetriebnahme (nicht rückstellbar)
Fehlermeldungen
Sollte wegen überfüllter Geldkassette eine Münze im Fallschacht stecken
bleiben, erscheint im Display die Anzeige„Fehler“. Durch längeres Drücken
der Taste „Betrieb“ läßt sich in jedem Betriebszustand des Gerätes ein
Reset durchführen.
5.7 Mehrfachmünzprüfer (Option „O“)
Bei der (Option„O“) handelt es sich um einen elektronischen Präzisionsmünzprüfer, in
dem die EURO € Verkehrs-Münzen (0,10; 0,20; 0,50; 1,00; 2,00 €) so wie eineWertmarke
vorprogrammiert sind. Es kann der einzuwerfende €- Geldbetrag in dem Menü Münzen
in der unter Punkt 4.2 beschriebenen Weise eingestellt werden. (Die passenden Wertmar-
ken sind unter der Art.-Nr. 2070 für WMA zu bestellen.)
6. Technische Daten
6.1 Technische Daten ZMZ 0205
Nennspannung 230 V ~ 50 Hz
Leistungsaufnahme 2 VA
Schaltleistung max. 10 A (16 A bei AC 1)
min. 20 mA (Relais „kurzgeschlossen“ mit Funkentstörkondensator)
Schutzart IP 31
Abmessungen (BxHxT) 185 x 238 x 150 mm
Gewicht ca. 3,0 kg
6.2 Technische Daten ZMZ 0215
Nennspannung 230 V ~ 50 Hz
Leistungsaufnahme 4 VA
Schaltleistung max. 10 A (16 A bei AC 1)
min. 20 mA (Relais „kurzgeschlossen“ mit Funkentstörkondensator)
mit Schütz 3x 20 A (3x 20 A bei AC 1)
Schutzart IP 31
Abmessungen (BxHxT) 185 x 238 x 150 mm (Aufputz)
235 x 280 x 165 mm (Unterputz)
Gewicht ca. 3,0 kg
7. Wartung
Die Geräte sind wartungsfrei. Lediglich der Münzeinwurf sollte von Zeit zu Zeit mit
einem Pinsel von Staub und Ablagerungen befreit werden.

NZR – Ihr Partner für Energiemessung 9
Technische Änderungen vorbehalten. -Technical details subject to charge. - Modification techniques réservées. - Riserva di modifiche tecniche.
8. Gewährleistung
Auf die Funktion des Gerätes wird eine Garantie von 12 Monaten gewährt. Die Garan-
tie beschränkt sich ausschließlich auf technische Mängel des Gerätes, weitergehende
Ansprüche können nicht anerkannt werden. Des Weiteren gelten die„Allgemeinen
Geschäftsbedingungen für Lieferungen und Leistungen der Elektroindustrie“.
9. Schaltbilder und Massbild
18 m5 m
3 m0 m 30 mm
45 mm
85 mm
50 mm
Gehäuse ohne Rahmen
2 5 mm3
Gehäuse mit Rahmen
0 m20 m
284 mm
127 mm
240 mm

NZR – Ihr Partner für Energiemessung
Technische Änderungen vorbehalten. -Technical details subject to charge. - Modification techniques réservées. - Riserva di modifiche tecniche.
10
10. Optionsübersicht
Mögliche Sonderausstattungen Art.Nr. ZMZ 0205 ZMZ 0215 ZMZ 0215
Wash‘n Dry LMZ 0115* LMZ 0232* LMZ
0236*/0436*
A6- / 5-stelliges Münzenzählwerk 3000
5-stellig
6-stellig
Standard
B1 Bei Stromausfall keine Münzenannahme 3010 -
CAkustisches Signal vor Zeitablauf; ab Werk einstellbar 3020 - - - - -
DWiedereinschaltsperre; Zeit einstellbar 3030 - - - - -
ESchlüsselschalter zur geldlosen Freigabe 3040
FZeitstoppautomatik bei 100 mA 3050 - - - - -
G3-phasiges Schaltschütz 3 x 20 A (empf.ab 2,2 kW) 3061
Standard - 1x 25 A 1x 63 A /
3x 63 A
L24 V Sicherheitskleinspannung für Feuchträume 3120 - - -
MTürentriegelung per Knopfdruck 3130 -
Standard - - -
OMehrfach Münzprüfer**; Freigabebetrag einstellbar 3151 -
Q1 Vorlaufzeit; Zeit einstellbar 3240 - - - - -
Q2 Relais für Nachlaufzeit;Zeit einstellbar 3250 - - - - -
SExterner Start 3180 - - - - -
TEinbruchschutz durch zusätzlichen Sperrbügel 3200
Art.Nr. 13201
UGleiche Schließung für das Gehäuseschloss 3210
V6-stelliger Betriebsstundenzähler 3190 - - - -
ZElektronische Zeitsteuerung für Duschen inklusive
1/2”Magnetventil und 230 V / 24 VTransformator 3280 - - - -
Münzeinwurf EURO-Münzen Art. Nr. Ergänzung * Zur Abrechnung zugelassen,geeichte Ausführung
0,10 Euro _ _ _ _ _ _ 69 Mögliche Sonderausstattung (Rücknahmen von Gerä-
ten mit falsch bestellten Optionen ausgeschlossen!)
0,20 Euro _ _ _ _ _ _ 70
0,50 Euro _ _ _ _ _ _ 71 Nicht gemeinsam mit „L“,„G“ oder „M“ lieferbar.
1,00 Euro _ _ _ _ _ _ 72 Nicht gemeinsam mit „F“ lieferbar.
Nur als Nachrüstsatz für bereits installierte
Gerätelieferbar.
2,00 Euro _ _ _ _ _ _ 73
Münzeinwurf Wertmarken Art. Nr. Ergänzung Hinweise: Sonderausstattung„G“ nicht gemeinsam
mit Sonderausstattung „L“ lieferbar.
Standard Wertmarke Ø 26 mm _ _ _ _ _ _ 74
Profil Wertmarke Ø 25 mm _ _ _ _ _ _ 76 Zeitsteuerung von Duschen mit magnetventil
Wertmarken bitte separat bestellen. • Liegt am Einsatzort ein 230 V Anschluss, wird die
Option „Z“ zur Steuerung benötigt.
• Liegt am Einsatzort ein 24 V Anschluss, wird die
Option „L“ sowie ein Magnetventil 1/2“ (Art. Nr. 5170)
zur Steuerung benötigt.
• Sollen mehrere Duschen (max. 5) mit Magnetventil
über einen Münzzähler betrieben werden, wird ein
stärkerer Trafo (100 VA, 24V, Art. Nr. 3290) benötigt.
Sprechen Sie uns bei Fragen einfach an!
Bestellhinweis
Bei Bestellung bitte Type und Buchstaben der gewünschten
Sonderausstattung angeben.
z. B. ZMZ 0205, 1,00€, A, T, Z
Art. Nr. 70530172, 3000, 3200, 3280

NZR – Ihr Partner für Energiemessung 11
Technische Änderungen vorbehalten. -Technical details subject to charge. - Modification techniques réservées. - Riserva di modifiche tecniche.
Inhalt / Directory / Sommaire / Indice
ZMZ 0205 / ZMZ 0215
Deutsch ........................................................................................................................................ 3
English
1. Installation / Safety ........................................................................................................................................ 12
2. Short manual ZMZ 0205
2.1 Settings ............................................................................................................................................................... 13
2.2 Time setting ...................................................................................................................................................... 14
2.3 Display ............................................................................................................................................................... 14
3. Special features
3.1 Coin register (Option„A“) ............................................................................................................................. 14
4. Short manual ZMZ 0215
4.1 Settings .............................................................................................................................................................. 14
4.2 Running time .................................................................................................................................................... 15
4.3 Number of coins ............................................................................................................................................. 15
5. Special features
5.1 Lag time (Option „Q2“) .................................................................................................................................. 16
5.2 Advance time (Option „Q1“) ........................................................................................................................ 16
5.3 External start / External stop (Option „S“) ............................................................................................... 16
5.4 Door unlock (Option„M“) ............................................................................................................................ 16
5.5 Coin register (Option„A“) 6-digit ................................................................................................................ 16
5.6 Elapsed time meter (Option „V“) ............................................................................................................. 17
5.7 Multiple coin validator (Option„O“) ......................................................................................................... 17
6. Technical data
6.1 ZMZ 0205 ........................................................................................................................................................... 17
6.2 ZMZ 0215 ........................................................................................................................................................... 17
7. Maintanace ..................................................................................................................................................... 17
8. Warranty ........................................................................................................................................................... 18
9. Wiring diagram and scale drawing ........................................................................................................ 18
10. Option overview ........................................................................................................................................... 19
Français ......................................................................................................................................... 20
Italiano ......................................................................................................................................... 29
NZR Technischer Support
Telefon +49 (0)5424 2928-0 E-Mail info@nzr.de

NZR – Ihr Partner für Energiemessung
Technische Änderungen vorbehalten. -Technical details subject to charge. - Modification techniques réservées. - Riserva di modifiche tecniche.
12
1. Installation ZMZ 0205 / ZMZ 0215
• Drill fixing holes in accordance with dimension drawing (Abb. 6)
• The coin meter can be mounted to the wall with the enclosed screws after opening
the device and dismounting the connecting covering cap.
• To secure the correct function of the coin meter, it is necessary to mount the coin
meter strictly vertical
Connection: Important! Before accessing the connection clamps, all power circles
has to be cut off.
VDE- and local regulations has to be attended
• On site, the connection has to be equiped with a switch of 3 mm break down.
• Carry the connection cords through cable sleeves
• For easy wiring the left part of connector is peelable. The terminal configuration is
printed on the terminal cover.
• Build up connection in accordance with wiring diagram (Abb. 1-5)
• While snap connector on keep secure latching in mind
• Refit terminal cover
Safety low-tension (Option „L“)
While usage in humid areas the connection with a 24 V safety low-tension is suggested.
Therefore you have to install a 24 V AC cord into the humid area. A 230 V / 24 V 100 VA
power transformator for up to 4 ZMZ controls is available ex factory.
ATTENTION!
These devices are not intended for use by persons (including children) with reduced
physical, sensory or mental abilities or lack of experience and/or knowledge, unless they
are supervised by a person which is responsible for their safety or received an instruction
in how to use the device.
Children should be supervised to ensure that they do not play with the device.
Security notice
To prevent any danger to people and damage to the device, you have to avoid the ingress
of moisture e.g. for depleting coins.
Short Manual
ZMZ 0205 / ZMZ 0215
ENG

NZR – Ihr Partner für Energiemessung 13
Technische Änderungen vorbehalten. -Technical details subject to charge. - Modification techniques réservées. - Riserva di modifiche tecniche.
2. Short manual ZMZ 0205
2.1 Settings
The ZMZ 0205 is equiped with a 1-digit LED to
display the number of inserted coins or remai-
ning time. Up to two coins can be insered into
the device at once.
Additional coins do not lengthen the remai-
ning time.
Afreshing of time can only occur after the termi-
nation of time. Time base can be switched from
HH:MM to MM:SS.
Delivery status
Jumper 1 open
only one coin will be accepted
Jumper 2 open
Upper Dip for setting of minutes
Lower Dip for setting of hours
Alternative settings
Jumper 1 closed
Insertion of two coins available
Circuit board ZMZ 0205
Jumper 2 closed
Upper Dip for setting of seconds
Lower Dip for setting of minutes
Value of Dip-switch:
1 – 2 – 4 – 8 – 16 – 32
Notice
To secure the activation of basic-settings and time-settings, it is essentisal to cut the de-
vice from power shortly. On first usage, the LED will flash four digits followed by a break.
The combination of digits indicates the installed software.The permanent display of the
digit „0“ indicates the ready-status.
Münzprüfer
Münzenzählwerk
B
1
B
2
Dip-oben
Dip-unten
124816 32

NZR – Ihr Partner für Energiemessung
Technische Änderungen vorbehalten. -Technical details subject to charge. - Modification techniques réservées. - Riserva di modifiche tecniche.
14
2.2 time setting
To set the running time, the imprinted values of Dip-switches set to „on“ position has to
be added.
E.G. Upper-Dip-switch
switch 1, 3 and 4 set to „on“
The result of addition of imprinted values is 13
In addiction of basic setting, the running time is set to 13 minutes or 13 seconds.
Lower-Dip-switch
switch 2 and 5 set to „on“
The result of addition of imprinted values is 18
In addition with the values of the upper-Dip-switch the total running time is 18 minutes
and 13 seconds or 18 hours and 13 minutes.
2.3 Display
After insertion of first coin a„1“ is displayed. After insertion of a second coin (if activated)
a „2“ is displayed.The display will jump back to „1“ if the time stock of second coin is used
up.When time stock reaches the last 9 minutes the remaining time flashes on display in
one minute steps. If the running time per coin is set to a lower value than 9 minutes, this
time will flash on display.
3. Special features ZMZ 0205
3.1 Coin register (Option „A“)
When ordering „Option A“ a mechanical 5-/6-digit non-resetable roller counter is moun-
ted on the cover for registration of all inserted coins.This option is retrofittable by factory
easily.

NZR – Ihr Partner für Energiemessung 15
Technische Änderungen vorbehalten. -Technical details subject to charge. - Modification techniques réservées. - Riserva di modifiche tecniche.
Münzprüfer
Prozessor
EPROM
Einstellungen
4. Short manual ZMZ 0215
4.1 Settings
For all settings the four buttons on
side-cut-out of terminal cover are
used. Press button„Betrieb“ before
and after every change of settings.
„Außer Betrieb“ is displayed after
first pushing the button.„Reset“
follwed by version number of
software is displayed after pushing
the button in normal operation. All
changeable values can be displayed
by multiple pushing of button
„Menü“.
Depending on version the following
information are displayed:
„Zeit“ (time) (running time)
„Münzen“ (coins) (number of coins)
optional „Nachlauf“ (lag) (lag of 2nd relay)
optional „Vorlauf“ (advance) (start delay)
optional „ext. Start“ (start with external button)
optional „ext. Stop“ (stop with external button)
4.2 Setting of running time
Within the menu „Zeit“ the cursor (underscore) can be scrolled to the position by multip-
le pushing the button „Auswahl“.
Push the button„Ändern“ to set the value of basic time in HH : MM : SS.
Push the button„Betrieb“ to return to operation mode or„Menü“ for next setting.
4.3 Number of coins
Calling up the menu „Münzen“ set the number of coins needed to start the device by
pushing the „Ändern“ button. Refer to 4.2 for further settings.
Circuit board ZMZ 0215

NZR – Ihr Partner für Energiemessung
Technische Änderungen vorbehalten. -Technical details subject to charge. - Modification techniques réservées. - Riserva di modifiche tecniche.
16
5. Special features ZMZ 0215
5.1 Lag time (Option“Q2“)
Set the lag-time of the second relay within the menu „Nachlauf“ as mentioned above.
Function is deactivated by setting value to „0“.
Notice
The lag-relay only needs to be operated with the identical voltage as the main relay on
circuit board of the ZMZ 0215.
5.2 Advance time (Option “Q1“)
Set advance-time within the menu „Vorlauf“ as mentioned above.
Function is deactivated by setting value to „0“.
5.3 External start / external stop (Option “S“)
The functions can be switsched on or off by pushing the „Ändern“ button within the
menu „ext. Start“ or „ext. Stop“.
The device is equiped with plug-in for an external switch on the upper terminal cover if
these options are installed.
Keep in mind to use a shielded control cable of max. 3m length to connect the switch.
5.4 Door unlock (Option „M“)
To unlock electrical doors of washing machines without insertion of a coin, the device
can be equiped with an additional button. After the basic time passed out, the power
can be switched on again for one minute by pushing the button to open the door.„Taste/
Münze“ is diplayed while activated.
5.5 6-digit coin register (Option „A“)
Push button„Betrieb“ and „Auswahl“ to read out the number of inserted coins.
Mz number quantity of inserted coins since last reset,
inserted amount of money at option „O“ (tokens ntot added)
GMz number Quantity of all inserted coins since start of operational time (not resetable)
amount of money at option „O“. You can switch between options by
pushing the „Menü“ button. Only the Mz Zahl is reset by pushing the
„Ändern“ button to request the „Löschen?“ display.

NZR – Ihr Partner für Energiemessung 17
Technische Änderungen vorbehalten. -Technical details subject to charge. - Modification techniques réservées. - Riserva di modifiche tecniche.
5.6 Elapsed time meter (Option „V“)
If the device is equipped with option „V“ go ahead like described under 5.5. In addition
the following registers are displayed:
FSZ Activation time in hours since last reset
GFSZ Total activation time since start of operation (not resetable)
Alarm message
In case of jammed coin caused by a cramped cash box „Fehler“ is displayed.
Reset the device by pushing the „Betrieb“ button longer.
5.7 Multiple coin validator (Option „O“)
Option „O“ is an electronical coin validator programmed for standard Euro coins (0,10;
0,20;0,50;1,00; 2,00 €) and tokens.The insertable Euro amount can be set in menu
„Münzen“ as mentioned in 4.2. (The tokens are available under item no. 2070 for WMA).
6. Technical data
6.1 Technical data ZMZ 0205
Voltage 230 V ~ 50 Hz
Consumption 2 VA
Switching power max. 10 A (16 A at AC 1)
min. 20 mA (relay„ short-circuited“ with noise suppression capacity)
Protection category IP 31
Dimension (WxHxD) 185 x 238 x 150 mm
Weight ca. 3,0 kg
6.2 Technical data ZMZ 0215
Voltage 230 V ~ 50 Hz
Consumption 3,6 VA
Switching power max. 10 A (16 A at AC 1)
min. 20 mA (relay„ short-circuited“ with noise suppression capacity)
With contractor 3x 20 A (3x 20 A at AC 1)
Protection category IP 31
Dimension (WxHxD) 185 x 238 x 150 mm (wall mounted)
235 x 280 x 165 mm (flush mounted)
Weight ca. 3,0 kg
7. Maintenance
The devices are maintenance-free. Only the coin slot should be cleaned with a brush
time-to-time.

NZR – Ihr Partner für Energiemessung
Technische Änderungen vorbehalten. -Technical details subject to charge. - Modification techniques réservées. - Riserva di modifiche tecniche.
18
8. Warranty
We offer a 12 month warranty on the function of the device. The warranty is
strictly limited to technical defects of the device. Further receivables can not be
accepted. In addition the„GENERAL CONDITIONS FOR THE SUPPLY OF PRODUCTS
AND SERVICES OF THE ELECTRICAL AND ELECTRONICS INDUSTRY“ are relevant.
9.Wiring diagram and scale drawing
Consumer connection with
potential-free relay contact Direct consumer connection Three-phase consumer connection
via contactor
Option L
Safety low-tension 24 V
Option Z
Electronical time control for shower
potential-free
relay contact
Dimensions
consumer consumer
consumer
18 m5 m
3 m0 m 30 mm
45 mm
85 mm
50 mm
Gehäuse ohne Rahmen
2 5 mm3
Gehäuse mit Rahmen
0 m20 m
284 mm
127 mm
240 mm

NZR – Ihr Partner für Energiemessung 19
Technische Änderungen vorbehalten. -Technical details subject to charge. - Modification techniques réservées. - Riserva di modifiche tecniche.
10. Option overview
Available Options Item no. ZMZ 0205 ZMZ 0215 ZMZ 0215
Wash‘n Dry LMZ 0115* LMZ 0232* LMZ
0236*/0436*
A6- / 5-digit coin counter 3000
5-digit
6-digit
Standard
B1 No coin acceptence during power outage 3010 -
CAcoustic signal before time laps can be set by factory 3020 - - - - -
DSwitch-off function, time adjustable 3030 - - - - -
EKey-switch for moneyless release 3040
FTime stopp automatic at 100 mA 3050 - - - - -
G3-phase contactor 3 x 20 A (recommended from 2,2 kW) 3061
Standard - 1x 25 A 1x 63 A /
3x 63 A
L24 V safety low voltage for humid areas 3120 - - -
MPush-button for door release 3130 -
Standard - - -
OMultiple coin tester**; release amount adjustable 3151 -
Q1 Lead time adjustable 3240 - - - - -
Q2 Relay for follow-up time, time adjustable 3250 - - - - -
SExternal start 3180 - - - - -
TBurglary protection with additional steel-bar 3200
Item no.13201
USame lock as housing 3210
V6-digit operating hour counter 3190 - - - -
ZElectonical time control for showers with included 1/2
inch magnetic valve and 230 V / 24 V transformer 3280 - - - -
Coin insertion EURO coins Additonal item no. * valid for billing - calibrated design
0,10 Euro _ _ _ _ _ _ 69 available special features (In case of misorders the
withdrawal of devices is excluded.)
0,20 Euro _ _ _ _ _ _ 70
0,50 Euro _ _ _ _ _ _ 71 not in combination with option „L“,„G“ or„M“
1,00 Euro _ _ _ _ _ _ 72 not in combination with option„F“
Rretrofit kit for mounted devices only.
2,00 Euro _ _ _ _ _ _ 73
Coin insertion Token Additonal item no. Note Option „G“ not available in combination with
option „L“.
Standard token Ø 26 mm _ _ _ _ _ _ 74
Profile token Ø 25 mm _ _ _ _ _ _ 76 Time control for showers with magnetic valve
Please order tokens separately. • Option „Z“ is required if a 230 V connection is
available at installation place.
• Option „L“ and a magnetic valve 1/2“ (Item no.
5170) is required if a 24 V connection is available at
installation place.
• A different transformator (100 VA, 24 V, Item no.
3290) is required if one device should handle up to 5
showers with magnetic valve.
Just contact us with any question!
Order note
In case of order note type and letter for recommended optional features:
e.g. ZMZ 0205, 1,00€, A, T, Z
Item No. 70530172, 3000, 3200, 3280

NZR – Ihr Partner für Energiemessung
Technische Änderungen vorbehalten. -Technical details subject to charge. - Modification techniques réservées. - Riserva di modifiche tecniche.
20
Inhalt / Directory / Sommaire / Indice
ZMZ 0205 / ZMZ 0215
Deutsch ......................................................................................................................................... 3
English ......................................................................................................................................... 11
Français
1. Montage / Sécurité ......................................................................................................................................... 21
2. Manuel d‘utilisation ZMZ 0205
2.1 Paramétres ........................................................................................................................................................ 22
2.2 Réglage de l‘heure ......................................................................................................................................... 23
2.3 Affichage .......................................................................................................................................................... 23
3. Equipements spéciaux
3.1 Compteur de pièce (Option„A“) ................................................................................................................ 23
4. Manuel d‘utilisation ZMZ 0215
4.1 Paramétres ........................................................................................................................................................ 24
4.2 Réglage de l‘heure du film .......................................................................................................................... 24
4.3 Modele de pièce .............................................................................................................................................. 24
5. Equipements spéciaux
5.1 Delay (Option „Q2“) ........................................................................................................................................ 25
5.2 Le délai de livraison (Option„Q1“) ............................................................................................................... 25
5.3 Externe de démarrage / Arrêt externe (Option„S“) ................................................................................ 25
5.4 Déverrouillage de la porte (Option„M“) ................................................................................................. 25
5.5 Compteur de pièce (Option „A“) 6-chiffres .............................................................................................. 25
5.6 Heures de fonctionnement du compteur (Option„V“) ........................................................................ 26
5.7 Multiple examinateur des pièces (Option „O“) ...................................................................................... 26
6. Spécifications
6.1 ZMZ 0205 ........................................................................................................................................................... 26
6.2 ZMZ 0215 ........................................................................................................................................................... 26
7. Entretien ........................................................................................................................................................... 26
8. Garantie ............................................................................................................................................................. 27
9. Des diagrammes et de dessin dimensionnel ........................................................................................... 27
10. Option aperçu ................................................................................................................................................... 28
Italiano ......................................................................................................................................... 29
NZR Technischer Support
Telefon +49 (0)5424 2928-0 E-Mail info@nzr.de
This manual suits for next models
1
Table of contents
Languages:
Popular Cash Counter & Coin Sorter manuals by other brands

ratiotec
ratiotec rapidcount T 200 Short user manual

Royal Sovereign
Royal Sovereign Fast Sort FS-3D owner's manual

ROHS
ROHS Currenza C2 Technical documentation

Royal Sovereign
Royal Sovereign RBC-3100 owner's manual

Cashmaster
Cashmaster One Pro user guide

Money Controls
Money Controls Compact Hopper Test Box instructions