MAINTENANCE AND CARE INSTRUCTIONS
Olympia products are designed and engineered under strict quality standards. Regular and proper care of our
products will ensure years of trouble free service. To clean, simply wipe with a damp, soft cloth. Do not use
abrasive or harsh cleaners as they may result in nish damage. Regularly remove and clean minor debris from
the aerator.
OLYMPIA FAUCETS, INC. LIMITED LIFETIME WARRANTY *
Olympia Faucets, Inc. warrants its products to the original consumer purchaser to be free from defects in material
and workmanship as long as the consumer purchaser owns it. Dated proof of purchase must accompany all war-
ranty claims. PVD nishes carry a lifetime warranty in residential service.
Olympia Faucets, Inc. will replace, free of charge, to the original consumer purchaser, any and all parts that
prove defective under normal installation, use, and service. Damage as a result of misuse, abuse, accident, or
improper installation, will consequentially void this warranty. Replacement parts can be obtained from your local
dealer or directly from Olympia Faucets. Olympia Faucets, Inc. recommends using a certied plumber for all
faucet installation and repair.
This warranty is limited to replacement of defective parts only. Incidental and consequential damages, labor
charges, repair, or replacement costs are expressly excluded. Some states do not allow the exclusion or limita-
tion of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives
you specic legal rights, as you may have other rights of which vary from state to state.
Installation or maintenance and cleaning must be in compliance with instructions furnished with every Olympia
product. If you nd a problem with your product, please immediately contact your nearest Olympia Faucets, Inc.
dealer or sales representative.
* 2 year limited warranty on commercial and multi-family projects.
INSTALLATION AND MAINTENANCE
INSTRUCTIONS FOR OLYMPIA SINGLE
HANDLE TUB AND SHOWER SETS
Caution: This product may not meet the current building code. This product is
not pressure balanced. Pressure balanced products are available from
Olympia. Please consult your nearest Olympia dealer.
PRODUCT NUMBERS
#P-2020 Single Handle Tub and Shower Set ~ Acrylic Handle
#P-2000 Single Handle Tub and Shower Set ~ Metal Handle
#P-2022 Single Handle Shower Only ~ Acrylic Handle
#P-2002 Single Handle Shower Only ~ Metal Handle
#P-2021 Single Handle Tub Only ~ Acrylic Handle
#P-2001 Single Handle Tub Only ~ Metal Handle
ADA
Olympia Faucets, Inc. © 2008
ATTENTION: IMPORTANT INFORMATION BEFORE YOU START
- For “Shower Only” installations, be sure to plug bottom (tub) outlet with the Brass Cap (I) supplied in the
Trim Package.
- For “Tub Only” installations, be sure to plug top (shower) outlet with the Brass Cap (I) supplied in the Trim
Package.
- For thread joint installations, always use Thread Sealant or Teon Tape on all threads.
Special Caution to Consumer: This valve is designed for ease of operation. Excessive force on
the handle may cause severe damage and will void the manufacturer’s warranty.
Thank you for purchasing this quality product. Olympia products are rigorously tested to provide long service
under normal conditions. Prior to installation, familiarize yourself with this parts diagram. Make sure that you have
all of the illustrated parts for your Olympia product before installation.
INSTALLATION INSTRUCTIONS
Tools you will need:
Plumbers Putty• Teon Tape•
Screwdriver• Flexible Supply Lines•
Pipe Wrench• Adjustable Wrench•
Basin Wrench• Soft Cloth•
STANDARD VALVE INSTALLATION:
Install valve with the word UP facing up towards the ceiling,1.
Connect water supply lines. Left side is hot, and Right side is cold.2.
Caution:- Use 1/2” IPS tapered thread connections. For 1/2” IPS straight thread connections may need to
use excessive thread sealant to prevent from leak.
3. NOTE: To obtain maximum valve operation, the following installation dimensions are strongly
Recommended:
- Distance between valve body and showerhead outlet should be a minimum of 36”.
- Piping between valve body and tub spout must not exceed 18”.
FLUSHING THE SYSTEM:
Prior to installing the showerhead(J). Turn to the fully “On” position. Slowly turn on the water sup-1.
plies for one minute to ush out debris in the lines. After ushing the system, turn off the water.
TRIM INSTALLATION:
Slide the Face Plate over the Sleeve Tube(F) and install with the 2 trim screws provided.1.
Install all remaining trim. For IPS Installation : (1) The 1/2” nominal pipe must be kept with a mini-2.
mum length of 4-1/4” length from nished face of the tub or wall. (2) Screw tub spout onto the pipe
and tighten by hand. Recommend using Teon Tape.
Place the handle on the stem. Secure the lever handle by tightening the set screw with 1/8” allen3.
wrench for lever handle or by Philips head screw for Acrylic Handle,
Olympia Faucets, Inc. © 2009
ITEM # DESCRIPTION
A1 OP-140006 Metal Lever Handle
A2 OP-490036 1/8” Allen Wrench
A3 OP-190008 Acrylic Ball Handle
A4 OP-490023 Acrylic Handle Adapter
B OP-490003 Cap & Adjusting Ring
C OP-490004 Cam & Washer
D OP-390001 Stainless Steel Ball
E OP-440018 Face Plate
F OP-440032 Valve Sleeve
G OP-420001 O-Ring
H OP-490041 Springs & Seats
I OP-440020 Cap
J OP-640031 Showerhead
K OP-640002 Shower Arm
L OP-640001 Shower Flange
M OP-640015 1/2” IPS Tub Spout
1 OP-440019 Faceplate Screws
For more care information or trouble shooting inquiries
about your Olympia product, please call:
OLYMPIA FAUCETS, INC. (888) 772-7701
Central Standard Time: 8:00am ~ 7:00pm
www.olympiafaucets.com

This manual suits for next models

5

Other Olympia Kitchen & Bath Fixture manuals

Olympia K-5120 User manual

Olympia

Olympia K-5120 User manual

Olympia L-7330 User manual

Olympia

Olympia L-7330 User manual

Olympia L-7470 Series User manual

Olympia

Olympia L-7470 Series User manual

Popular Kitchen & Bath Fixture manuals by other brands

Kohler Sterling 33197 installation guide

Kohler

Kohler Sterling 33197 installation guide

Belanger 6177CP quick start guide

Belanger

Belanger 6177CP quick start guide

Mira Combiforce 415 Installation and user guide

Mira

Mira Combiforce 415 Installation and user guide

Hans Grohe ShowerSelect S Instructions for use and assembly instructions

Hans Grohe

Hans Grohe ShowerSelect S Instructions for use and assembly instructions

Helvex Novara E-930 installation guide

Helvex

Helvex Novara E-930 installation guide

baliv KV-4030 manual

baliv

baliv KV-4030 manual

Grohe 33 388 manual

Grohe

Grohe 33 388 manual

Swiss Madison Ivy SM-DF81 installation instructions

Swiss Madison

Swiss Madison Ivy SM-DF81 installation instructions

IKEA LAGAN 605.220.92 manual

IKEA

IKEA LAGAN 605.220.92 manual

Gerber C4-44-050-61 manual

Gerber

Gerber C4-44-050-61 manual

BEMIS bioBidet Flow Classic 33262056833110 owner's manual

BEMIS

BEMIS bioBidet Flow Classic 33262056833110 owner's manual

Kohler Contra 26448T-4 installation instructions

Kohler

Kohler Contra 26448T-4 installation instructions

Lefroy Brooks M1-4715 Installation, operating,  & maintenance instructions

Lefroy Brooks

Lefroy Brooks M1-4715 Installation, operating, & maintenance instructions

Sanipex BAGNO DESIGN OROLOGY BDM-ORO-301S Series installation guide

Sanipex

Sanipex BAGNO DESIGN OROLOGY BDM-ORO-301S Series installation guide

Moen WS84876 installation guide

Moen

Moen WS84876 installation guide

Sani-Lav 512FFL operating manual

Sani-Lav

Sani-Lav 512FFL operating manual

RUBINETTERIE Bellosta Plisset Diamond 4205/S Installation instruction

RUBINETTERIE

RUBINETTERIE Bellosta Plisset Diamond 4205/S Installation instruction

Helvex Nuva TV-200 installation guide

Helvex

Helvex Nuva TV-200 installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.