One Hour Comfort Sentry Elite Flow-Through Humidifier... User manual

SPECIFICATION GUIDE
PRODUCT DETAILS
The Comfort Sentry™ Elite Flow-Through Humidifier 900 adds moisture into
the airflow of your heating system, providing comfort as it humidifies your
home. Between 40% to 60% relative humidity is ideal for today’s homes.
Outside of this range, bacteria, fungi, viruses and mites thrive. This system
humidity provides a healthier environment for your woodwork, furniture,
plants, pets, and your family.
• Reduces heating costs
• Protects valuables such as woodwork, furniture, artwork, and electronics
• Great for indoor plants and pets
FEATURES
• Automatic digital display included for easier operation
• Home Sizes up to 2,800 Sq. Ft
• Easy to remove from housing and easy to install
• Reinforced tabs and heat treated reinforced plastic
• 10 year warranty
The EPA has ranked indoor air pollution
among the top five environment
dangers to the public.
Comfort Sentry
Elite Flow-Through Humidifier
Sinusitis
Respiratory Infections
Throat & Ear Infection
Bronchitis
Pneumonia
E
F
F
E
C
T
S
Memory Lapse
Mild Depression
Lung Dysfunction
Blurred Vision
Headaches
Lethargy
E
F
F
E
C
T
S
Nose & Throat Irritation
Runny Nose
Congestion
Sneezing
Coughing & Wheezing
Asthma Flares
E
F
F
E
C
T
S
DIRT, DUST
& POLLEN
Element 1
Element 2
GERMS, BACTERIA
& VIRUSES
Element 3
TOXIC GASES
& ODORS
Element 4
HUMIDITY &
TEMP. CONTROL
A
L
L
E
R
G
E
N
S
&
P
A
R
T
I
C
U
L
A
T
E
S
T
O
X
I
C
C
O
M
P
O
U
N
D
S
G
E
R
M
S
,
B
A
C
T
E
R
I
A
&
V
I
R
U
S
E
S
Common Cold
Pneumonia
SARS - Influenza
Tuberculosis
Streptococcus
Pneumococcus
Dirt
Mildew
Dust
Pollen
Smoke
Insect Debris
Mold & Fungi
Toluene
Benzene
Pesticides
Tobacco Smoke
Nitrogen Dioxide
Mold Mycotoxins
Methylene Chloride
Humidity/dehumidify
Control
Wi-Fi & Energy Saving
Thermostats
Fresh Air Ventilation
Temperature Zoning & Control
Throughout Entire House
C
O
M
F
O
R
T
/
D
I
S
C
O
M
F
O
R
T
E
F
F
E
C
T
S
Cold & Hot Spots
Asthma Issues
Sleep Problems
Unhealthy / Unsafe
Dryness
This Product Controls
Maintain Proper Indoor
Humidity For Greater
Comfort
APPLICATION
• Reduce dry or itchy skin caused by
dry air
• More comfortable indoor air that
feels warmer
HUMIDIFIER
ENERGY AWARE
TM
CS900A-OH
CS900M-OH
T
E
N
Y
E
A
R
W
A
R
R
A
N
T
Y
W
A
R
R
A
N
T
Y

© 2017 Clockwork IP, LLC, 4-2016 | www.onehourproducts.com
SPECIFICATION GUIDE
CS900A-OH
CS900M-OH
INSTALLATION INSTRUCTIONS
1. Install on either the supply or return plenum of a forced air handling system. Cut out a rectangle 8-7/8” wide by 9-1/2“ tall. Extend horizontal center line of cut out
to the adjacent plenum. Cut a 6” hole 10” to 15” from side of humidifier, on cabinet center line, using connecting collar as guide.
2. Slide top side in first, then slide chassis down. Level chassis and install center screws. If by-pass pipe installs to opposite side of chassis, bend clip on chassis,
remove side discharge, and reinstall discharge to opposite side of chassis. Install remaining four corner screws.
3. Connect by-pass pipe to collar and humidifier cabinet. Using holes at top and bottom of side panel discharge, pierce 2 self tapping screws through by-pass pipe.
4. Mount the self tapping saddle valve or code valve on either a cold or a hot water pipe. Connect 1/4” O.D. tubing to the saddle valve.
5. Connect 1/4” water supply tube to brass filter at in let of solenoid. Turn damper knob to winter (open) position. Turn on water supply and check operation of
humidifier. Set humidistat to a demand setting. With the furnace o, the solenoid valve should be closed.
6. Start the furnace, the solenoid valve should open when the blower or burner circuit is energized. Check flow of water through distributor trough and evaporator
pad. Leave humidistat set at the recommended setting.
7. Connect drain hose to 1/2” spout on humidifier cabinet using hose clamp. Run 1/2” hose to suitable drain such as floor drain, sewer or laundry sink.
8. Wire unit using appropriate diagram in accordance with local ordinances.
SAFETY NOTES
• Do not use plastic tubing on hot water or in contact with any hot plenum surface or duct.
• Installation of this saddle valve must meet or exceed local codes and ordinances.
PRODUCT SCHEMATIC
570 Performance Baseline Criteria
Outside Design Temp: 0° F (-18° C) Inside Design: RH 30% Loose (.75 ACH): 1115 Sq. Ft
Outside Design: RH 70% Ceiling Height: 8’ Average (.50 ACH): 1650 Sq. Ft
Inside Design Temp: 70° F (21° C) Plenum Temperature: 120° F (49° C) Tight (.30 ACH): 2800 Sq. Ft.
900-14 DRAIN PAN
900-11 DAMPER KNOB
900-28 DAMPER DISK
570-2 SIDE PANEL
DISCHARGE
570-40 PAD RAIL
GA-10 EVAPORATOR PAD
900-15 DISTRIBUTOR TROUGH
570-13 COVER
GA4231 YELLOW ORIFICE
P190 COMP. SLEEVE (PLASTIC)/P102 COMP. SLEEVE (BRASS)
P101 COMPRESSION NUT
570-1 CHASSIS
900-9 NOZZLE
900-10 SPOUT
GA4226 DISTRIBUTOR TUBE
GA4040 SOLENOID VALVE ASM
GA4004 STAINER SCREEN
P102 COMPRESSION SLEEVE
P101 COMPRESSION NUT
P189 BRASS TUBE INSERT
747-38 TUBING KIT (AVAILABLE)
PARTS LIST FOR HUMIDIFIER
RECOMMENDED
SETTING
15%
20%
25%
30%
35%
40%
AT
OUTSIDE
TEMPERATURE
-20°F -29°C
-10°F -23°C
0°F -18°C
+10°F -12°C
+20°F - 7°C
+30°F - 1°C
Your humidifier is engineered to give helpful and trouble-free humidification. For maximum efficiency the following cleaning procedures should be carried out at
the end of each heating season:
1. Turn off water supply and electrical power to humidifier.
2. Remove water cover, distributor trough, evaporator pad and drain pan. Clean excessive mineral deposits from the
distributor trough, drain pan, pad rails, and humidifier cabinet. A solution of 1/2 vinegar & 1/2 water will help loosen mineral
deposits.
3.
Replace humidifier evaporator pad if necessary. (Part number GA10) Install trough and drain pan.
Replace cover. Replace evaporator pad yearly for peak performance.
4. In heavy mineral areas or if the solenoid valve fails to function disconnect the 1/4” water supply line from the solenoid valve.
Carefully pull the strainer screen (P.N. GA4004) from the valve body (P.N. 900-6). Clean the mineral deposits from all
parts. If the orifice is clogged, it may be opened by inserting a small pin. Reinsert the filter into the orifice fitting and screw
the brass strainer body into the solenoid valve.
5. Reconnect the 1/4” water line to the solenoid valve if necessary. Turn on the water supply and check all points for leakage.
The operation of the unit may be checked by starting the furnace. The humidifier operates only when the furnace blower is
running or the burner circuit is energized. The humidifier is now ready for operation.
6. During the summer, turn off water supply and electrical power to humidifier. Close air damper.
CARE AND MAINTENANCE
LIMITED WARRANTY
This humidifier, if properly registered by the return of the warranty registration card to the manufacturer, is warranted to the consumer against defects in
materials and workmanship for a period of ten years from the date of installation. Evaporator pads, water strainers or metering orifices are not covered by this
limited warranty or any other warranties. Any other defective parts will be repaired without charge except for removal, reinstallation and transportation costs.
To obtain repair service under this limited warranty, the consumer must send the defective part or the complete humidifier to the manufacturer.
THERE ARE NO EXPRESS WARRANTIES COVERING THIS HUMIDIFIER OTHER THAN AS SET FORTH ABOVE, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. THE MANUFACTURER ASSUMES NO LIABILITY IN
CONNECTION WITH THE INSTALLATION OR USE OF THIS PRODUCT, EXCEPT AS STATED IN THIS LIMITED WARRANTY. THE MANUFACTURER
WILL IN NO EVENT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.
This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow either
limitations on implied warranties, or exclusions from incidental or consequential damages, so the above exclusion and limitation may not apply to you.
Any questions pertaining to this limited warranty should be addressed to the manufacturer. (U.S.A.: The manufacturer has elected not to make available the
informal dispute settlement mechanism which is specified in the Magnuson-Moss Warranty Act.)
900-71 BADGE
Popular Humidifier manuals by other brands

Kenmore
Kenmore Quiet comfort 758.144160 whole house humidifier 12 gallon... owner's manual

pureguardian
pureguardian H1500 Use & care instructions

Field Controls
Field Controls AN 129 Installation instructions & owner's manual

HoMedics
HoMedics HUM-CM50 Instruction manual and warranty information

Yokekon
Yokekon YK-MH-2118 user manual

EUROM
EUROM LB2.5 Instruction leaflet

Honeywell
Honeywell HCM-890 Series owner's manual

HoMedics
HoMedics TOTALCOMFORT UHE-WM10 Instruction manual and warranty information

Philips
Philips HU4801 user manual

Somogyi Elektronic
Somogyi Elektronic UHMP5000 instruction manual

Challenge
Challenge HTJ-2027 instruction manual

Essick
Essick H12 300HB Owner's care & use manual