Overview
The RSL10 Smart Shot Color Camera (SECO-RSL10-CAM-COLOR-GEVK) is a complete ultra-low-power,
event-triggered, node-to-cloud platform that enables smart image capture for portable, low duty cycle
IoT applications including asset monitoring and event-triggered camera. Based on the RSL10 SIP and the
ARX3A0 CMOS image sensor (color and mono), the platform features multiple trigger modes including
periodic intervals, motion detection, and environmental sensor triggers (e.g. changes in temperature and
humidity). The RSL10 SIP serves as the processing hub of the camera, and Bluetooth® Low Energy
(Bluetooth LE) connectivity enabling remote control and transfer of captured image and sensor data to
the provided mobile app (available on GooglePlay™ , iOS® ).
This guide provides instructions for using the RSL10 Smart Shot Color Camera and accompanying mobile
application. For further information about the platform, refer to the User Manual.
To get started with the platform, you will need:
•RSL10 Smart Shot Camera (SECO-RSL10-CAM-COLOR-GEVK)
•RSL10 Smart Shot mobile app
•RSL10 FOTA mobile app
•Amazon Web Services™ (AWS™) account credentials to use Amazon Rekognition™
Hardware Setup
The RSL10 Smart Shot Color Camera kit includes the baseboard PCB, two ARX3A0 IAS camera modules
and a USB cable. By default, the color ARX3A0 IAS module is mounted onto the PCB and the mono IAS
module is bundled with the kit. To use the mono IAS module, swap the module onto the baseboard PCB.
The firmware supports both module, and is capable of automatically identifying the modules. In this guide,
we will be using the color IAS module.

Figure 1. Unboxing the RSL10 Smart Shot Camera
To get started with the kit, remove the protective layer from the camera module and connect the provided
USB cable to your PC’s USB port (Fig.2).
A green LED, shown in figure 2 below, will begin blinking to confirm that the device is ready and in BLE
Advertising Mode.

Figure 2. Operation after Micro USB is Connected
Install the RSL10 Smart Shot Mobile App
In order to operate the board, download
RSL10 Smart Shot
mobile app from GooglePlay™ or iOS®. After
installing the app, ensure that Bluetooth and GPS are enabled on your phone. The following sections detail
steps to capture images from the camera over Bluetooth Low Energy, set trigger events, perform image
analytics using AWS Rekognition and perform wireless firmware updates (FOTA).
Figure 3. RSL10 Smart Shot Mobile App

Connect to the Camera
The home screen of the mobile app displays the RSL10 Smart Shot Camera as a discovered device.
Select the device to connect the camera to the mobile app (fig. 4).
Figure 4. Connecting the RSL10 Smart Shot Camera to the Mobile App

Capture Image
After the camera is connected, the app will switch to the image capture page in Figure 5. Click the
Camera
icon to instruct the camera to take a picture. The image captured by the camera is transferred
over Bluetooth Low Energy and is displayed on the screen. To save the image on your mobile phone,
click the
Save i
con. On an Android phone, the image is stored in the
RSL10Smartshot
directory. On
iPhone, the image is stored in your
Photos
directory.
Figure 5. Using the RSL10 Smart Shot App to Capture and Save a Picture

Capture Stream of Images
The camera also can capture continuous stream of images with different frame rates. Click the
Settings
icon
on the top right corner and toggle the
Mode
option from
Single Image
to
Stream
. You can also adjust
the frame rate from <1 frame/second to 1 frame/minute.
Exit the
Settings menu
by tapping the bottom of the screen. Click the
Play button
to start streaming
images, and click the
Stop button
to stop.

Figure 6. Stream Mode
Setting Event Triggers
The RSL10 Smart Shot Camera supports four environmental sensors, which can be used to trigger image
capture whenever a change in value is detected.
To set or change the triggers, select the
Settings icon
. You can turn the triggers ON or OFF by toggling
the switch for each sensor. For temperature and humidity sensors, you can also set the minimum and
maximum thresholds values, and trigger an event when the sensors detect values outside the range. You
can enable either an individual sensor or a combination of sensors to set your trigger condition for image
capture.

Figure 7. Environmental Trigger Settings
Exit the
Settings menu
by tapping the bottom of the screen. The RSL10 Smart Shot Camera will
be armed and capture an image each time event conditions are triggered. The captured image
along with the triggered event condition will be displayed on the screen.

Figure 8. Sensor Triggered Image Capture

Object Recognition using Amazon Rekognition
The mobile app uses Amazon Rekognition cloud engine to analyze the image and identify objects within
it. The captured image is uploaded to the cloud engine for analysis, and results are displayed on the app.
More information about the Amazon Rekognition setup is available in the platform User Manual.
You should specify your AWS account credentials to use this feature. Select the
Settings icon -> AWS
Account
on the Home Screen.
Figure 9. Accessing Amazon Rekognition

Enter the
accessKey
and
secretKey
associated with your AWS account and click
Use
. After
logging in, you can use the
Face icon
shown below to analyze pictures captured with the
RSL10 Smart Shot Camera.

Figure 10. Using Amazon Rekognition to Analyze Captured Images
Firmware over the Air (FOTA) Updates
The RSL10 Smart Shot Camera supports wireless firmware updates using the RSL10 Bluetooth 5 radio.
You will need:
•RSL10_SMARTSHOT_FIRMWARE_UPDATE_PACKAGE.zip
•RSL10 FOTA mobile app (available on GooglePlay™ , iOS® ).
•
•Unzip above package and download the
smartshot_demo_color_cam.fota
image file to your mobile
To get started, unzip the RSL10 Smart Shot Firmware update package and download the
smartshot_demo_color_cam.fota image file to your mobile device.
Note: FOTA only updates the RSL10 SoC firmware. To update the Image Sensor Processor firmware
(SPCV1100A) refer to the
SmartShot Firmware Update Guide.html
under
RSL10_SMARTSHOT_FIRMWARE_UPDATE_PACKAGE.zip
.
The boards can be switched into FOTA mode by pressing and holding the on-board push button PB1
during normal operation over RSL10 FOTA mobile application.
This section describes over the air updates via RSL10 FOTA Mobile Application. Switch to FOTA mode is
indicated by 1 second long flash of LED. The platform will then be discoverable on the RSL10 FOTA app.

Figure 11. Switching to FOTA Mode
After selecting the device on the mobile app, you can update the firmware by clicking Select File to
import the new firmware. Click Connect and Update to send the firmware to the device.

Figure 12. Sending Firmware Updates
Figure 13. Firmware Update Process

Power Down Mode
In Power Down Mode, all systems are put into low power modes to consume the lowest possible amount
of power. Low Power Mode can be entered by keeping the on-board button PB1 pressed after releasing
the reset button. To return to normal operation, press the RESET button (PB_RST).
Figure 14. On-board Power and Reset Buttons

www.onsemi.com
1
onsemi, , and other names, marks, and brands are registered and/or common law trademarks of Semiconductor Components Industries, LLC dba “onsemi” or its affiliates
and/or subsidiaries in the United States and/or other countries. onsemi owns the rights to a number of patents, trademarks, copyrights, trade secrets, and other intellectual property. A
listing of onsemi’s product/patent coverage may be accessed at www.onsemi.com/site/pdf/Patent−Marking.pdf. onsemi is an Equal Opportunity/Affirmative Action Employer. This
literature is subject to all applicable copyright laws and is not for resale in any manner.
The evaluation board/kit (research and development board/kit) (hereinafter the “board”) is not a finished product and is not available for sale to consumers. The board is only intended
for research, development, demonstration and evaluation purposes and will only be used in laboratory/development areas by persons with an engineering/technical training and familiar
with the risks associated with handling electrical/mechanical components, systems and subsystems. This person assumes full responsibility/liability for proper and safe handling. Any
other use, resale or redistribution for any other purpose is strictly prohibited.
THE BOARD IS PROVIDED BY onsemi TO YOU “AS IS” AND WITHOUT ANY REPRESENTATIONS OR WARRANTIES WHATSOEVER. WITHOUT LIMITING THE FOREGOING,
onsemi (AND ITS LICENSORS/SUPPLIERS) HEREBY DISCLAIMS ANY AND ALL REPRESENTATIONS AND WARRANTIES IN RELATION TO THE BOARD, ANY
MODIFICATIONS, OR THIS AGREEMENT, WHETHER EXPRESS, IMPLIED, STATUTORY OR OTHERWISE, INCLUDING WITHOUT LIMITATION ANY AND ALL
REPRESENTATIONS AND WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE, NON−INFRINGEMENT, AND THOSE ARISING FROM A
COURSE OF DEALING, TRADE USAGE, TRADE CUSTOM OR TRADE PRACTICE.
onsemi reserves the right to make changes without further notice to any board.
You are responsible for determining whether the board will be suitable for your intended use or application or will achieve your intended results. Prior to using or distributing any systems
that have been evaluated, designed or tested using the board, you agree to test and validate your design to confirm the functionality for your application. Any technical, applications or
design information or advice, quality characterization, reliability data or other services provided by onsemi shall not constitute any representation or warranty by onsemi, and no additional
obligations or liabilities shall arise from onsemi having provided such information or services.
onsemi products including the boards are not designed, intended, or authorized for use in life support systems, or any FDA Class 3 medical devices or medical devices with a similar
or equivalent classification in a foreign jurisdiction, or any devices intended for implantation in the human body. You agree to indemnify, defend and hold harmless onsemi, its directors,
officers, employees, representatives, agents, subsidiaries, affiliates, distributors, and assigns, against any and all liabilities, losses, costs, damages, judgments, and expenses, arising
out of any claim, demand, investigation, lawsuit, regulatory action or cause of action arising out of or associated with any unauthorized use, even if such claim alleges that onsemi was
negligent regarding the design or manufacture of any products and/or the board.
This evaluation board/kit does not fall within the scope of the European Union directives regarding electromagnetic compatibility, restricted substances (RoHS), recycling (WEEE), FCC,
CE or UL, and may not meet the technical requirements of these or other related directives.
FCC WARNING – This evaluation board/kit is intended for use for engineering development, demonstration, or evaluation purposes only and is not considered by onsemi to be a finished
end product fit for general consumer use. It may generate, use, or radiate radio frequency energy and has not been tested for compliance with the limits of computing devices pursuant
to part 15 of FCC rules, which are designed to provide reasonable protection against radio frequency interference. Operation of this equipment may cause interference with radio
communications, in which case the user shall be responsible, at its expense, to take whatever measures may be required to correct this interference.
onsemi does not convey any license under its patent rights nor the rights of others.
LIMITATIONS OF LIABILITY: onsemi shall not be liable for any special, consequential, incidental, indirect or punitive damages, including, but not limited to the costs of requalification,
delay, loss of profits or goodwill, arising out of or in connection with the board, even if onsemi is advised of the possibility of such damages. In no event shall onsemi’s aggregate liability
from any obligation arising out of or in connection with the board, under any theory of liability, exceed the purchase price paid for the board, if any.
The board is provided to you subject to the license and other terms per onsemi’s standard terms and conditions of sale. For more information and documentation, please visit
www.onsemi.com.
PUBLICATION ORDERING INFORMATION
TECHNICAL SUPPORT
North American Technical Support:
Voice Mail: 1 800−282−9855 Toll Free USA/Canada
Phone: 011 421 33 790 2910
LITERATURE FULFILLMENT:
onsemi Website: www.onsemi.com
Europe, Middle East and Africa Technical Support:
Phone: 00421 33 790 2910
For additional information, please contact your local Sales Representative
◊
Other manuals for RSL10 Series
3
This manual suits for next models
1
Other onsemi Digital Camera manuals
Popular Digital Camera manuals by other brands

Canon
Canon PowerShot SD1400IS IXUS130 user guide

Huawei
Huawei HoloSens quick start guide

Pentax
Pentax Optio 330RS operating manual

Daheng Imaging
Daheng Imaging VENUS USB3 Series user manual

Panasonic
Panasonic LUMIX DMC-FS10 Basic operating instructions

Argus
Argus BeanSpraut VGA Carabiner Camera user manual