Function Setting (Continued)
Manual Adjustment
Error Display in Teaching
An error message is displayed in the event of error during adjustment.
Refer to the table below for readjustment.
* No operation state for 5 seconds during setting automatically returns the display to
normal as well.
Normal
Automatically returns to
the normal display 5
seconds after completion of
the setting (no operation).
When using zone teaching
Setting Lower Limit (Far)
Indicates shortage of light intensity or no difference
of light intensity.
Indicates a sampling error in teaching of a moving object.
Indicates a calculation error.
Indicates that the teaching process was interrupted.
Setting Upper Limit (Near)
Pressing the UP/DOWN button in the RUN mode flashes the threshold value. This
indicates that adjustment is possible. Adjust to any value using the UP/DOWN button.
When using the zone teaching, the threshold values of both the upper and lower limit can
be set individually .
Automatically returns to the normal display 5 seconds
after completion of the setting (no operation).
Manual Setting
Error Display
Precautions for Function Settings
* indicates factory default setting
* Settings that are not available will not be indicated automatically.
This does not indicate a problem or failure.
*
Hold down the operation button for approx. 0.3 seconds if not specified differently.
* The sub monitor starts flashing when each setting selection becomes available.
Returning to Normal Display from Function Settings
Pressing and holding the button for more than 2 seconds while in the function settings
will return the sensor to the normal display (RUN mode) without using Eit (Exit).
*Invalid while setting the timer time, or span value.
Key Lock
Cancels all the operations. Useful to prevent accidental operation.
Hold down both of the buttons for more than 2 seconds in the RUN mode to
activate the Key Lock function. Repeat this procedure to cancel the Key Lock.
Locked Unlocked
Optex-FA U.S. sales
Ramco Innovations
(800) 280-6933
www.optex-ramco.com
Span setting
is for span change, is for digit
change, and is to set. The screen returns
to the TOPof Span setting.
TOP
Set the span of the analog output.
Select by using and set by .
The screen moves to each detail setting.
Set 20 mA.
Set 4 mA.
5.7.2 Span setting
TOP
Select either turn on or turn off the analog output.
Select by using and set by .
The screen returns to the TOPofAnalog
output setting.
Activates the analog output.
Turns off.
5.7.1 Analog output setting
TOP
Select the state of the analog output when the
measurement is out of range.
Select by using and set by .
The screen returns to the TOPof Output
clamp hold setting.
Hold just before measurement
becomes impossible.
Set the output to approx. 24 mA.
5.4.3 Output clamp hold
setting
TOP
Select a number of samples to average together.
Select by using and set by .
The screen returns to the TOPof Average
counter setting.
Set.
Average counter
1/4/8/16/32/64/128/256/
512/1024/2048
5.4.4 Average counter setting
TOP
Select the type of hold function to perform if desired.
Select by using and fix by .
The screen returns to the TOPof Hold setting.
Peak hold
Normal measurement
Bottom hold
Peak to Peak hold
5.4.5 Hold setting
5.4.6 End of Analog function
setting
Returns to the TOPof Analog function setting.
* Full scale of the default is as follows:
Thru-beam or Reflection type: 0 - 4000 (Amount of
received light)
T
After end of 4A setting, the screen moves to 20A setting.
Reset "Peak/ Bottom hold"
The Peak/Bottom hold function can be reset by changing the amplifier from
Run to Set and back again.
SET
UN
Confirm the position of the "SET/RUN" switch is in the "RUN" position.
Move the switch position to "SET" and return to "Run" again.