OptoTest OP280MT User manual

Ribbon Visual Fault Locator
Instruction Manual
OP280MT
www.optotest.com 1.805.987.1700

1 of 8
Contacting OptoTest Corporation
1.805.987.1700 (7:30 a.m. to 5 p.m. PST)
www.optotest.com
OptoTest Corp.
4750 Calle Quetzal
Camarillo, CA 93012 USA
Notice of Proprietary Rights
The design concepts and engineering details embodied in this manual, which are
the property of OptoTest Corporation, are to be maintained in strict condence. No
element or detail of this manual is to be spuriously used or disclosed without the
express written permission of OptoTest Corporation. All rights are reserved. No part
of this publication may be reproduced, stored in a retrieval system, or transmitted
in any form or by any means, electronic, mechanical, photocopying, recording, or
otherwise, without prior written permission from OptoTest Corporation.
COPYRIGHT © 2016 by OptoTest Corp
ALL RIGHTS RESERVED
PRINTED IN THE UNITED STATES OF AMERICA
MnOP280-RevC

OP280MT
2 of 8
Table of Contents
Overview 3
Initial Preparation 4
Front Panel Operation 5
Sequences 6
Charging the OP280MT 7
Care & Maintenance 7
USB Control of the OP280MT 7
Warranty Information 8

OP280MT
3 of 8
Overview
The OP280MT is designed to check for breaks in a ribbon ber and to verify correct
polarity of ribbon ber connectors, hybrid cables and distribution boxes quickly
and conveniently. Each of the twelve bers is illuminated with bright 635nm red
LASERs.
The Ribbon Fiber Visual Fault Locator can be used for single mode or multimode
applications and is pre-programmed with various sequences for automatic or
individual scanning of each ber. User dened patterns can be programmed via
the USB data port.
Features
• 12 Individual super bright red lasers, one per ber
• Use for fault location up to a few hundred meters
• Internal rechargeable battery
• USB chargeable
• Programmable patterns for the various connection types

OP280MT
4 of 8
Initial Preparation
Unpacking and Inspection
The unit was carefully inspected, mechanically, electrically and optically before
shipment. When received, the shipping carton should contain the items listed in
Standard Contents. Account for and inspect each item. In the event of a damaged
instrument, write or call OptoTest Corp, California.
Note: Be aware that accessories such as detector adapters, remote head
detectors, and high performance reference cables will be located inside a small box
labeled “Accessories Inside”. If this box is not included with the original shipment,
contact OptoTest of their nearest distributor.
Please retain the shipping container in case re-shipment is required for any reason.
Damaged In Shipment
All instruments are shipped F.O.B. Camarillo when ordered from OptoTest.
If you receive a damaged instrument you should:
1. Report the damage to your shipper immediately.
2. Inform OptoTest Corporation.
3. Save all shipping cartons.
Failure to follow this procedure may aect your claim for compensation.
Standard Contents
1. Model OP280MT Ribbon Visual Fault Finder
2. USB A-B and Power Cables
3. Interface Sacricial Cable and Performance Bulkhead Mating Adapter
4. Certicate of Conformance
5. Instruction Manual(s)
6. CD with applicable software and documentation (if ordered)

OP280MT
5 of 8
On | Off Button
Turns the unit on or off. When turned on the unit starts up with
sequence #1. This is indicated with LED #1 blinking. The unit will
stay on until turned off again.
Pressing the On/Off button for a few seconds will cause the unit
to display the level of the battery charge. The number of LEDs
illuminated is proportional to the battery life (12 LEDs=full charge).
Select | Advance
When the LED is blinking, pressing this button turns on the first
combination of lasers for the selected sequence. The LED will go
from blinking to solid.
When the unit is operating the lasers (LED solid) pressing this button
will advance to the next sequence step. The next combination of
lasers will turn on.
If the Advance button is pressed and held for a few seconds
the unit will automatically cycle through the sequence steps.
This automatic play of the sequence is stopped by pressing the
Advance button again.
Select Sequence
When the LED is blinking, pressing this button switches to the next
programmed sequence. The unit stores up to twelve sequences,
4 pre-programmed and 8 user programmable. The sequences are
programmed using the OPL-280MT application software.
Supported OP280MTs are configured to work in conjunction with the
OP480MT to quickly analyze the cable type (A, B, C, etc). To put the
OP280MT in the proper mode to function with the OP480MT, press
and hold the “Select Sequence” button for 5 seconds and release.
When ready, the unit will flash LED #1 until the button is released. In
this mode the LASERs will quickly cycle through all available LASER
sources and be easily recognized by an OP480MT.
Front Panel Operation

OP280MT
6 of 8
Sequences
The first four sequences are pre-programmed and represent the common
configuration types A thru D. The individual lasers are turned on such that at the far
end of the ribbon cable the individual fibers are lit up sequentially starting with fiber
#1, then #2, ending with fiber #12.
The sequences 5 thru 12 are user programmable. The OP280MT can be
programmed with any standard Windows based computer connected to the
OP280MT via USB cable. The app OPL-280MT allows one to retrieve and program
each individual sequence, as well as set the brightness of the lasers.
Sequence 1
Sequence 2
Sequence 3
Sequence 4
Standard Conguration Type A
Type B
Pair Wise Flip Type C
Universal Conguration Type D

OP280MT
7 of 8
Charging the OP280MT
The OP280MT can be charged with the supplied USB cable. The unit will be fully
charged in approximately 12 hours.
NOTE: If the unit is being operated while charging, it will take longer to full charge
the battery.
Discharged Unit
A completely discharged unit will take approximate 10 minutes to power back on.
Care and Maintenance
As with any fiber optic test equipment it is essential that the optical interface of
BOTH the cable being inserted into the OP280MT as well as the MT bulkhead of
the OP280MT is kept clean.
For cleaning MT ferrules, the MT Clean product or similar is recommended.
To protect the OP280MT, optical interface we recommend to connect an Interface
Sacrificial Cable, such as those included in the OP-POLARITYKIT12.
USB Control of the OP280MT
The OP280MT is controlled via the USB bus. Commands are available via the
OP280.DLL to communicate with the instrument through a program. Contact
OptoTest for the latest release of the OP280.DLL.

OP280MT
8 of 8
Warranty Information
OptoTest Corp. warrants this product to be free from defects in material and
workmanship for a period of one year from date of shipment. During the warranty
period we will, at our option, either repair or replace any product that proves to be
defective. To exercise this warranty contact OptoTest Corp. headquarters. You will
be given prompt assistance and return instructions. Repairs will be made and the
instrument returned, transportation prepaid. Repaired products are warranted for
the balance of the original warranty period, or at least 90 days.
NOTE: Do not send instruments for any reason without contacting OptoTest
headquarters first.

OP280MT
9 of 8

For Application Notes, more detailed Testing Instructions, and the
most up-to-date OptoTest News go to www.optobuzz.com

www.optotest.com
1.805.987.1700
Table of contents