5
Programming for the Orisec Wi-Fi Module
1. Enter engineers code
*At default the Orisec control panels are set for full compliance with EN5013-1 and
PD6662:2017 and may request a user to authorise engineers access.
2. Programming menu - press E or R arrow to enter the menu.
3. Navigate to ‘Coms Modules’ (option 14) and press E or R arrow to enter the
menu.
4. Scroll down to ‘Wi-Fi settings’ press E or R arrow to enter the menu.
5. Enter the following information:
SSID = enter the routers SSID (if scanned previously this will already be populated)
Password = The password for the router
Address = Local IP address for the network (i.e. 192.168.1.75)
Port = Port number for the Orisec Wi-Fi Module (i.e. 20000)
Example screen:
Checking Status for the Orisec Wi-Fi Module.
1. Enter engineers code
*At default the Orisec control panels are set for full compliance with EN5013-1 and
PD6662:2017 and may request a user to authorise engineers access.
2. Tests & diagnostics - press E or R arrow to enter the menu.
3. Navigate to ‘View module status’ (option 6) and press E or R arrow to enter
the menu.
4. Scroll across to ‘Wi-Fi’ status. The screen will show one of the following;
Status: Not fitted
Status: Initialising
Status: Ready
Status: In Fault