manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. OwlTech
  6. •
  7. Security System
  8. •
  9. OwlTech SPMW300R User manual

OwlTech SPMW300R User manual

This manual suits for next models

3

Popular Security System manuals by other brands

Polon-Alfa 4000 Installation and maintenance manual

Polon-Alfa

Polon-Alfa 4000 Installation and maintenance manual

Nexcom NViS 14162 Series user manual

Nexcom

Nexcom NViS 14162 Series user manual

Eminent EM8670 Quick install

Eminent

Eminent EM8670 Quick install

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

urmet domus

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

SmartPool YardGuard YG03 manual

SmartPool

SmartPool YardGuard YG03 manual

DSC PC5964 Mounting instructions

DSC

DSC PC5964 Mounting instructions

Secure USAB-1 operating instructions

Secure

Secure USAB-1 operating instructions

B&B 480 SERIES Operation & maintenance manual

B&B

B&B 480 SERIES Operation & maintenance manual

ADEMCO VISTA-20P Series Installation and setup guide

ADEMCO

ADEMCO VISTA-20P Series Installation and setup guide

Inner Range Concept 2000 user manual

Inner Range

Inner Range Concept 2000 user manual

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Johnson Controls

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Aeotec Siren Gen5 quick start guide

Aeotec

Aeotec Siren Gen5 quick start guide

Swann SW-P-MC2 Specifications

Swann

Swann SW-P-MC2 Specifications

Ecolink Siren+Chime user manual

Ecolink

Ecolink Siren+Chime user manual

EDM Solution 6+6 Wireless-AE installation manual

EDM

EDM Solution 6+6 Wireless-AE installation manual

Siren LED GSM operating manual

Siren

Siren LED GSM operating manual

Detection Systems 7090i Installation and programming manual

Detection Systems

Detection Systems 7090i Installation and programming manual

FRIEDLAND MA10 Installation and operating instructions

FRIEDLAND

FRIEDLAND MA10 Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

http://www.owltechcctv.com
Solar Power Microwave Installation Manual
SPMW300R
SPMW300T-500
SPMW300T-1000
SPMW300E
4-8pcs IPC
1pcs IPC
2pcs IPC
4-8pcs IPC
NO
50AH
100AH
50AH
NO
100W
200W
100W
Transmission Rate Transmission Distance Solar Panel Lithium Baery no. of IPC
(data transmission)
Product
300Mbps 1.5 Mile
http://www.owltechcctv.com
NVR
SPMW300R
POE Switch
Router
Receiving Module
Solar Power Microwave Installation Manual
Built-in high-gain
antenna 1.5 Mile
coverage, no wiring
H1 H2 H3 H4 I
J K
E
NM
Should power supply irregular occurs, check if POE
switches are working properly, wiring is correct.
If the microwave power indicate abnormal, you need to
contact the engineers, returned to factory for repair.
Feature
Part
Item Remark
When LED is Always Off & Always On, please check if network
wiring and connectors are proper.
Power normal
Power abnormal
Receiving normal
Microwave signal normal
Microwave signal abnormal
LAN1 working properly
LAN1 no access to network
LAN1 excepon
LAN2 working properly
LAN2 no access to network
LAN2 excepon
1 x RJ-45 for 10/100 Mbps(802.3at/802.3af POE)
Flash
Always Off
Always On
Flash
Always Off
Always On
Flash
Always On or Off
H1 to H4 Flashing Cycle
On
Off
1 x RJ-45 for 10/100 Mbps
EPower-On LED
I
J
K
M
N
H1 H2 H3 H4
Microwave Signal
Strength Indicator
Microwave Working LED
LAN2 Port
LAN1 Port
LAN1 Working LED
LAN1 Working LED
http://www.owltechcctv.com
Solar power Integrated
transmission system
module
Built-in high-gain
antenna 1.5 Mile
coverage, no wiring
SPMW300T-500/SPMW300T-1000
Solar panel IP Camera
Transmitting module
H1 H2 H3 H4
L
I
M
E
D1 D2 D3 D4
G F
B
A
C
J K
http://www.owltechcctv.com
FeaturePartItem Remark
Power Input AC100-AC240 ~50/60Hz
Charging State
Keep the power off state during transportation
Accessory: Converter (DV12V & Network plug) for IPC
connection
Before connecting solar pane, make sure the power switch
to "O" state,
connect negative electrode first, then the positive electrode.
When IPC Working LED is Always Off & Always On, if I
PC power LED (F) is checked normal, please check if IPC
wiring and connectors are proper.
IPC came with waterproof connector, need to put
waterproof head onto Cat5e / Cat6 cable in advance,
then perform crimping the crystal head.
If the microwave power indicate abnormal, you need to
contact the engineers, returned to factory for repair.
According to the signal strength, to adjust the angle and
direction inbetween the microwave receive and transmit.
If there is no output of solar panel, please check if there
is crack in solar panel, wiring is correct or cable is
damaged.
Should power supply irregular occurs, if there is
sufficient sunshine, the device will be charged up
automatically and recovered, IPC & Microwave
will enter normal working stage when battery is recovered
to normal level, human intervention is not required. If it is
unable to recover for a long time, please check if there is
crack in solar panel, wiring is correct or cable is damaged.
Should power supply irregular occurs, if there is
insufficient sunshine, need to remove the microwave
device, charge via the external charging port.
For several days without or insufficient sunlight, battery
too low will happen. When sunlight restored, the solar
panels will charge up the battery, according to sunlight
conditions, it takes 5-15 days to fully charge the battery.
SPMW300-500 charging time 6 hours can be filled, do
not charge more than 10 hours
SPMW300-1000 charging time 12 hours can be filled,
do not charge more than 20 hours
After fully charged, unplug the power cord and turn the
power switch to "O" state, charging indicator stays On
for a while then Off and this is a normal phenomenon
due to a small electric charge by capacitor within
the charging device, charging indicator will turn Off after
discharge.
Make sure Power Switch is Off before charging, plug in
the charging power cord, and then Switch to charging
state
After fully charge, first unplug the charging power cord,
and turn the Switch to Off state
RX+
RX-
TX+
+12V
+12V
TX-
GND
GND
1
2
3
4
5
6
7
8
Solar Panel - positive
Solar Panel - negative
+
-
IPC working properly
IPC No access to IPC
IPC exception
IPC is working properly
No access to IPC
IPC exception
Flash
Always Off
Always On
Flash
Always Off
Always On
Microwave signal normal
Microwave signal abnormal
Flash
Always On or Off
Microwave signal strength, H1 (weak),
H4 (strong)
Receiving device not found
H1-H4 Always ON
H1 to H4 Flashing Cycle
On
Off
Solar panel power output normal
Solar panel no power output
Microwave power supply normal
Microwave power supply abnormal
IPC power supply normal
IPC power supply abnormal
On
Off
On
Off
Battery Low, charging
Battery Middle, charging
Battery is fully charged
Red
Pink
Green
Battery Level Full
Battery Level above 75%
Battery Level above 50%
Battery Level above 25%
Battery Level below 25%
Solar Panel is charging the battery
Power On
Power Off
On
On
On
On
Flash
D1 to D4 Flashing Cycle
Battery Level Indicator
-
O
=
M
IPC Port
L
Solar Panel Input Port
IPC2 Working LED K
J
IPC1 Working LED
I
Microwave Working
LED
G
Solar Panel Power-On
LED
F
PIC Power-On LED
E
Microwave Power-On
LED
C
Charging Indicator
B
Charging Port
A
Power Switch
D1
H1 H2
H3 H4
Microwave Signal
Strength Indicator
D4
D3
D2
SPMW300T device usage precaution
SPMW300-500
http://www.owltechcctv.com
100%
25% 100%
OFF
(Ch arg e)
ON OFF
(Ch arg e)
ON
OFF
(Ch arge)
ON
OFF
(Ch arg e)
ON
SPMW300-1000
100%
Device battery level should below 25% for transportation,
fully charged is prohibited.
Special circumstances so require fully charged in transport,
take precaution to avoid Intense vibration or collision,
high temperature.
Device inside enclosed car under sun exposure is prohibited.
Banging the device is prohibited.
Drilling the device is prohibited.
Storage environment above 120 ° F (50 ° C) or below
14 ° F (-10 ° C) is prohibited.
Device installation height up as far as
possible, in the shadow of solar panel to
reduce sun exposure.
Solar panel installation Angle,
SBW 15 degrees
-20
-10
0
0
10
20
30
40
50
20
40
60
80
100
120
°F °C
-10°F
-20
-10
0
0
10
20
30
40
50
20
40
60
80
100
120
°F °C
127°F
2
3
4
5
6
7
8
1
When delivered to installation site,
device charging steps as below:
(1). Power switch to "-" state, device selftest, battery level indicator
(D) shown normal.
(2). Power switch to "O" state
(3). Plug in charging power cord
(4). Power switch to "=" state
(5). SPMW300-500 takes about 6 hours to fully charge, do not charge
more than 10 hours.
SPMW300-1000 takes about 12 hours to fully charge, do not
charge more than 20 hours.
(6). After fully charged, unplug the charging power cord, turn the power
switch to "O" state, charging indicator stays On for a while then Off,
this is a normal phenomenon due to a small amount of electric
charge by capacitor within the charging device, charging indicator
will turn Off after discharge.
(1) (2) (3) (4)
(5)(6)
12
hrs 6hrs
N
W
S
E
SBW 15
degrees
15
N
S
W E
http://www.owltechcctv.com
1PCS
Cable Pipe 6
1PCS
Power Cord (charging purpose)
(B)(A) 2PCS 2PCS
(A)
(B)
Bracket (pair)
5 olar Panel Extension
Cable (one pair, Red/Black)
1PCS ( C )
(D)
(F) (G)
(E)
2PCS ( B ) 2PCS 1PCS
14PCS
14PCS14PCS
14PCS
2 Sets
(B)(A) 1PCS 1PCS
SPMW300R
1PCS
(A)
Solar Panel (100W)
DC12V defiber
bo om
SPMW300T-500
1PCS
bo om
Parts List - SPMW300R & SPMW300T-500
Solar Panel Bracket(Single Plate)
http://www.owltechcctv.com
SPMW300R
1PCS
bo om
SPMW300T-1000
1PCS
bo om
(B)(A) 2PCS 2PCS
(A)
(B)
Bracket (pair)
1PCS
Power Cord (charging purpose)
5 olar Panel Extension
Cable (one pair, Red/Black)
Solar Panel Connectors
(female & male)
Parts List - SPMW300R & SPMW300T-1000
2PCS
(B) (D)
(E) (G) (H)(F)
2PCS ( C ) 2PCS 1PCS
30PCS 30PCS30PCS30PCS
2 Sets
(B)(A) 1PCS 1PCS2PCS
1PCS
(A) 2PCS
Solar Panel (100W) Solar Panel Bracket (double plates)
DC12V defiber
Cable Pipe 6
1. 2. 3.
- fixed brackets A onto the solar panel with the
provided screw
http://www.owltechcctv.com
Solar Microwave System Installation
4. 5. 6.
7.
- assemble brackets D & C with the provided screws
- Solar panel installaon angle should be South
West 15 degree.
- fixed brackets B onto the unitwith the provided
screws
- fixed the whole bracket onto the solar panel with
the provided screws
8.
- The upper part of the device is baery, lower part is
microwave module.
Try to install the device up near the solar panels to avoid
direct sunlight on the device.
9.
- adjust surveillance recording angle
Open the package Screw set & fasten way
Install solar panel onto the pole Install the micro base staon Install the camera
http://www.owltechcctv.com
Solar Microwave System Installation
Note:
10. Solar Microwave System cabling
- perform cabling in according to the schemac diagram
1. Microwave signal receiving angle range is 60° (as shown in the figure below)
2. Adjust the receiver and transmier direcon angle, the stronger the signal,
the beer.
Microwave signal receiving
angle range is 60°