Oxgard K-17 User manual

VOZROZHDENIE LLC
OKPD 27.90.40.190
ТУ 27.90.40-001-33120038-2018
APPROVED BY
ВЗР.2499-00.00.000LU
GATE
MODELK-17
ВЗР.2499-00.00.000IM
INSTALLATION MANUAL
27 sheets
2020

ВЗР.2499-00.00.000IM
Gate K-17
Installation Manual
2
CONTENTS
1General Provisions ......................................................................................................................... 4
2Safety precautions.......................................................................................................................... 5
3Preparing the product for installation ........................................................................................... 6
3.1 Procedure for transporting the product to the installation site ................................................. 6
3.2 Rules for unpacking the product............................................................................................. 6
3.3 Rules for visual inspection of the product ............................................................................... 6
3.4 Product installation site requirements..................................................................................... 7
4Product installation and dismantling............................................................................................. 8
4.1 Equipment required................................................................................................................ 8
4.2 Product installation................................................................................................................. 8
4.3 Product dismantling.............................................................................................................. 10
5Gate connection and setting........................................................................................................ 11
5.1 Gate connection diagram ..................................................................................................... 11
5.2 Setting of gate operations modes......................................................................................... 12
5.3 Power connection................................................................................................................. 15
5.4 Control panel connection...................................................................................................... 16
5.5 Access control and management system connection (optional)............................................ 16
5.6 Control panel connection to the ACS controller .................................................................... 19
6Comprehensive inspection .......................................................................................................... 22
6.1 Visual inspection and verification of the product readiness for use....................................... 22
7Acceptance of the installed product............................................................................................ 23

ВЗР.2499-00.00.000IM
Gate K-17
Installation Manual
3
This Installation Manual (IM) applies to Oxgard gate K-17 and its
modifications (hereinafter referred to as the product).
IM defines rules and a procedure for installation and commissioning of the
product.
Before installing the product, please read the Operation Manual ВЗР.2499-
00.00.000 (OM) as well.
Due to constant work on improving the product, changes to its design may
be made, which are not represented in this IM revision.
The following abbreviations are used in this document:
OM —Operation Manual;
IM —Installation Manual;
PSU - power supply unit;

ВЗР.2499-00.00.000IM
Gate K-17
Installation Manual
4
1 GENERAL PROVISIONS
For general safety when assembling and installing the product, take into
account all the recommendations and instructions contained herein.
Before starting installation work, completely de-energize the product.
DO NOT:
INSTALL THE POWER SUPPLY MODULE INSIDE THE PRODUCT BODY
AS IT MAY RESULT IN ELECTRIC SHOCK TO PERSONS.
INSTALL PRODUCT NOT IN DRY AND HEATED ROOMS, EXCEPT FOR
MODIFICATIONS WITH INDEX A.
APPLY PASTES AND LIQUIDS CHEMICALLY AGGRESSIVE TO
MATERIALS OF THE HOUSING WHEN CLEANING THE PRODUCT.

ВЗР.2499-00.00.000IM
Gate K-17
Installation Manual
5
2 SAFETY PRECAUTIONS
Installation should be carried out with observance of "Regulations for
Operation of Consumer Electrical Installations" and "Safety regulations for
Operation of Consumer Electrical Installations".
The product shall only be installed by qualified personnel trained in
handling of electrical devices and instructed on safety precautions when handling
the electrical installations with voltages of up to 1000V.
ATTENTION: FAILURE TO COMPLY WITH THE SAFETY
REQUIREMENTS SPECIFIED IN THIS SECTION CAN RESULT IN DEATH AND
DAMAGE TO HEALTH, COMPLETE OR PARTIAL LOSS OF PERFORMANCE
OF THE PRODUCT AND/OR AUXILIARY EQUIPMENT.
ATTENTION: MANUFACTURER WAIVES ANY RESPONSIBILITY
FOR DEATH AND DAMAGE TO HEALTH, COMPLETE OR PARTIAL LOSS OF
PERFORMANCE OF THE PRODUCT AND/OR AUXILIARY EQUIPMENT IF
USER FAILS TO COMPLY WITH THE SAFETY REQUIREMENTS SPECIFIED
IN THIS SECTION, AND ALSO VOIDS THE PRODUCT WARRANTY.

ВЗР.2499-00.00.000IM
Gate K-17
Installation Manual
6
3 PREPARING THE PRODUCT FOR INSTALLATION
3.1 Procedure for transporting the product to the installation site
The product in the original package can be transported without range
limitation by air, closed road and rail transport provided it is protected against
direct exposure to precipitation and dust.
In order to avoid condensation of moisture after transportation at subzero
temperatures, the product shall be held in a room with normal climatic conditions
for 12 hours.
Loading and unloading operations should be carried out in compliance with
safety regulations.
3.2 Rules for unpacking the product
3.2.1 Perform visual inspection of the packaging. There shall not be
visible damage on the package.
3.2.2 Open the transportation box, unpack and check completeness of
the product:
3.3 Rules for visual inspection of the product
3.3.1 Check completeness of the product.
Completeness shall be checked according to the Logbook ВЗР.2499-
00.00.000 (LB).
3.3.2 Visually inspect the product. There shall not be visible damage
on the product.

ВЗР.2499-00.00.000IM
Gate K-17
Installation Manual
7
3.3.3 If any damage is found, prepare a Claim Report.
3.3.4 Figure 1 –overall product dimensions
Figure 1 –overall product dimensions
3.4 Product installation site requirements
ATTENTION: TO AVOID SWING AND/OR OVERTURN DURING
OPERATION, INSTALL THE PRODUCT SECURELY. IN CASE OF PRODUCT
INSTALLATION ON LOW STRENGTH FLOOR, TAKE MEASURES FOR
INSTALLATION SITE FLOOR STRENGTHENING.

ВЗР.2499-00.00.000IM
Gate K-17
Installation Manual
8
4 PRODUCT INSTALLATION AND DISMANTLING
4.1 Equipment required
Equipment required for the product installation:
1) electric perforating machine
2) 16 mm carbide drill bit for drilling anchor holes in the floor (we recommend SORMAT
PFGES10 М10-60 anchor);
3) S6 hollow head screw hex wrench;
4) cross-point screwdriver;
5) plumb or level;
6) steel shims for product leveling;
4.2 Product installation
ATTENTION: THOROUGHLY READ THIS SECTION OF THE MANUAL
BEFORE INSTALLING THE PRODUCT
ATTENTION: IT IS RECOMMENDED TO MARK OUT LOCATING
HOLES AGAINST HOLES IN GATE POST BASE FLANGE WITH MOUNTED
FLAP.
4.2.1 Prepare a level ground at the product installation site.
4.2.2 Prepare cable trench or duct from site to the BP and control
buttons installation site.
4.2.3 Attach gate flap to post using set screws. Make sure that gate flap is
securely attached to post.
4.2.4 Figure 2 –mark out and drill 3 holes of 16mm in diameter in the floor
for the gate post anchors.

ВЗР.2499-00.00.000IM
Gate K-17
Installation Manual
9
Figure 2 –Installation site mounting dimensions
The depth of holes for embedded parts shall exceed the anchor length by 5mm.
Insert anchors into the holes.
4.2.5 Lay PSU and control buttons cables into the cable duct or trench.
4.2.6 Install the gate post to the prepared site.
4.2.7 Align the gate post holes with the floor anchors.
4.2.8 Check that installed gate is vertical in 2 planes, use steel shims of
required thickness for the correct gate installation, where necessary.
4.2.9 Fasten gate base flange with three screws M10 by screwing these into
the proper anchors using the S6 wrench.

ВЗР.2499-00.00.000IM
Gate K-17
Installation Manual
10
4.2.10 Lead cables from PSU, ACS and control panel into the product
housing. Secure the cables with cable ties.
4.3 Product dismantling
4.3.1 When sending the product for calibration or repair, dismantle
product as follows:
1) turn product power off;
2) disconnect the product from the power supply source;
3) disconnect the product cable part from auxiliary cables;
4) remove the product from the installation site.
4.3.2 Before packing, clean the product from dust and dirt.
4.3.3 Put the product in a packing box.

ВЗР.2499-00.00.000IM
Gate K-17
Installation Manual
11
5 GATE CONNECTION AND SETTING
5.1 Gate connection diagram
Figure 3 –gate diagram and diagram of PSU and control panel connection
to gate control board.
LED strip / Motor/ Red / Orange / Blue / Green / Solenoid / Encoder / Control panel / Socket / Plug
Figure 3 –Gate connection diagram

ВЗР.2499-00.00.000IM
Gate K-17
Installation Manual
12
Figure 4 –the gate control board appearance and layout of the connectors
for connecting the PSU, CP, ACS and SFAS are shown.
Figure 4 –Gate control board appearance
For power connection, use the double-wire cable ShVVP 2×1.5 up to 10m,
and for ACS connection, use the eight-wire signal cable.
5.2 Setting of gate operations modes
To access the setting mode:
1. Switch to “STOP” or “ANTI-PANIC” mode.
2. Press and hold “LEFT” and “ANTI-PANIC” buttons for 5 seconds.
3. All LEDs will be off.
4. Within 3 seconds, press and release “STOP” button while holding “LEFT” and
“ANTI-PANIC” buttons.
5. Then:
- when gate is in the pulse mode, blue indicator lights up, and while in potential
mode, white indicator lights up;
- “ANTI-PANIC” LED is flashing, when gate switches to “ANTI-PANIC” mode
with corresponding ACS contacts closed, or “ANTI-PANIC” and ”STOP” LEDs are

ВЗР.2499-00.00.000IM
Gate K-17
Installation Manual
13
flashing, when gate switches to “ANTI-PANIC” mode with corresponding ACS contacts
broken.
6. Thereupon, release the other buttons.
7. Now gate is in programming mode; you may choose and write the required
operation mode.
4 gate setting modes are available from panel:
1. Gate operation control mode selection (pulse or potential);
2. “ANTI-PANIC” mode opening direction selection;
3. Panel on/off selection;
4. Selection of mode of switching to «ANTI-PANIC” mode with ACS contacts
closed or broken.
5. Reset to factory settings.
1. Gate operation control mode selection (pulse or potential).
- In the programming mode, white indicator lights when gate is in the potential mode
or blue indicator lights while in the pulse mode.
To change the operation mode:
- Press and hold “STOP” button for 5 seconds until gate LED strip changes from
white to blue (switching to pulse mode) or from blue to white (switching to potential
mode).
- Thereupon, release “STOP” button.
- To store settings in memory, press and hold “STOP” button once again for 5 seconds
until gate calibration starts. During calibration, all CP buttons are flashing, and gate
swings to the fully open position, stops and then returns to initial position.
- After this, gate is restarted; it switches to the calibration mode, and indicators light up
blue (pulse mode) or white (potential mode).

ВЗР.2499-00.00.000IM
Gate K-17
Installation Manual
14
2. “ANTI-PANIC” mode opening direction selection.
- switch the gate to programming mode.
To change direction:
- Press and hold “LEFT” button. After the “LEFT” button is held for 5 seconds,
“LEFT” and “RIGHT” LEDs light up.
- The “ANTI-PANIC” mode opening direction changes to opposite one.
- Then release “LEFT” button.
- To store settings in memory, press and hold “LEFT” button once again for 5 seconds
until gate calibration starts. During calibration, all CP buttons are flashing, and gate
swings to the fully open position, stops and then returns to initial position.
After this, gate is restarted; it switches to the calibration mode, and indicators light up
blue while in pulse mode and white while in potential mode.
3. Panel on/off selection.
- switch the gate to programming mode.
To switch panel off:
- Press and hold “RIGHT” button. After the button is held for 5 seconds. When gate
control commands were sent from panel, it switches off, and otherwise, if panel was off,
gate panel control command issue function is enabled.
- To store settings in memory, press and hold “RIGHT” button once again for 5
seconds until gate calibration starts. During calibration, all CP buttons are flashing, and
gate swings to the fully open position, stops and then returns to initial position.
After this, gate is restarted; it switches to the calibration mode, and indicators light up
blue while in pulse mode and white while in potential mode.
4. Selection of mode of switching to «ANTI-PANIC” mode with ACS contacts closed
or broken.
- switch the gate to programming mode.
- in the programming mode, “ANTI-PANIC” LED is flashing, when gate switches to
“ANTI-PANIC” mode with corresponding ACS contacts closed, or “ANTI-PANIC” and
”STOP” LEDs are flashing, when gate switches to “ANTI-PANIC” mode with
corresponding ACS contacts broken.
To change mode
- Press and hold “ANTI-PANIC” button. After the “ANTI-PANIC” button is held
for 5 seconds, only “ANTI-PANIC” LED lights up, and gate switches to “ANTI-PANIC”
with closed ACS contacts, otherwise, “ANTI-PANIC” and “STOP” LEDs light up, and
gate switches to “ANTI-PANIC” with broken ACS contacts.
- Then release “ANTI-PANIC” button.

ВЗР.2499-00.00.000IM
Gate K-17
Installation Manual
15
- To store settings in memory, press and hold “ANTI-PANIC” button once again for 5
seconds until gate calibration starts. During calibration, all CP buttons are flashing, and
gate swings to the fully open position, stops and then returns to initial position.
After this, gate is restarted; it switches to the calibration mode, and indicators light up
blue while in pulse mode and white while in potential mode.
5. Reset to factory settings.
- To reset to factory settings, switch the gate to the programming mode.
- While in programming mode, press and hold “LEFT” and “ANTI-PANIC” buttons
for 3 seconds until the gate is restarted. After the restart and calibration, gate is reset to
following factory settings:
- pulse control mode
- panel is on for controlling the gate
- gate switches to the “ANTI-PANIC” at making the “AP” and “GND” contacts.
- “ANTI-PANIC” mode opening direction is leftward.
5.3 Power connection
DO NOT:
USE THE POWER SUPPLY UNITS WITH AN OUTPUT CURRENT BELOW
5A.
PRODUCT POWER CONNECTION USING THE CABLE WITH CROSS-
SECTION LESS THAN 1.5MM2IS PROHIBITED. WHEN POWER CABLE
LENGTH EXCEEDS 10M, IT IS RECOMMENDED TO USE CABLE WITH
CROSS-SECTION OF 2.5MM2.

ВЗР.2499-00.00.000IM
Gate K-17
Installation Manual
16
ATTENTION: IT IS NOT RECOMMENDED TO USE PULSE POWER
SUPPLY UNITS AND TO INSTALL POWER SUPPLY UNITS MORE THAN 25M
APART FROM PRODUCT.
The gate is powered by 24VDC power supply. Maximum current
consumption –4A. PSU should be selected based on these parameters.
It should also be taken into account that voltage drop increases with
increase in supply cable length (for operating voltage range, see OM).
Install the PSU in location ensuring easy operator access. Figure 3 –
Connect in accordance with diagram. Make sure that the cable is securely
connected.
5.4 Control panel connection
CP is connected through the telephone socket H16 on the gate control
board TJ3-6P6C using the telephone connector RJ12(G)\6P6C.
TJ3-6\6P6C RJ 12(G)\6P6C
5.5 Access control and management system connection (optional)
The ACS controller shall be connected to the gate control contact group

ВЗР.2499-00.00.000IM
Gate K-17
Installation Manual
17
Identification of contacts: LEFT, RIGHT, STOP, АР, GND. The contact
assignment is shown in Table 2.
Table 1 –ACS contact assignment
Identification of contacts
Contact assignment
LEFT, RIGHT
one-time passage left/ right
(lower priority)
STOP
passage forbidden ("Stop" mode)
(medium priority)
GND
common contact
AP
free passage in both directions ("Antipanic")
(highest priority)
Inputs for ACS connection differ in priority:
1) AP input has the highest priority. If the AP command was sent to this input (AP is closed
to the GND contact), the gate is in free passage mode and DOES NOT RESPOND(!) to any
commands as long as AP is closed to the GND contact; green LEDs are flashing on the
indication panel. AP command can only be cancelled by breaking the AP from GND.
2) In order to enable “ANTI-PANIC” mode, close or break AP to GND contact. 4 modes (see
p. 5.2 of this manual) are available through setting
3) LEFT and RIGHT have the same low priority and enable one-time passage in either
direction. When both inputs are closed, passage is permitted in direction, of which input
was closed first. In case that no passages are performed, gate switches to the “STOP”
mode automatically in 7 seconds.
ATTENTION: WHEN THE AP INPUT IS CLOSED TO GND, PANEL
COMMANDS ARE IGNORED, SINCE THE ACS HAS A HIGHER PRIORITY.
LEFT and RIGHT inputs can operate in both potential and pulse modes
(tripping in respond to closing to GND contact). Pulse mode is set by default.
To switch to the potential operation mode, follow the operation mode
selection instructions in p. 5.2. In this case, left/right passage mode is only
enabled as long as the control signal is delivered to LEFT/RIGHT inputs.

ВЗР.2499-00.00.000IM
Gate K-17
Installation Manual
18
Control board is equipped with two "dry contact" relay outputs for the ACS:
PassOk1(R) - to the right, and PassOk1(L) - to the left.
NO and COMM –fail safety connection, NC and COMM –fail secure
connection.
Tripping of one of contacts groups indicates the gate closing, PassOk1(R)
–to the right, PassOk1(L) –to the left. “Dry contact” makes/breaks at the start of
gate flap closing.
Control board is equipped with the AP "dry contact" relay output for the
ACS. Its contacts (NC, NO and COM) make or break when gate switches to the
"AP" mode, and VD24 LED lights up .
Ошибка! Источник ссылки не найден. Some LEDs are installed on
control board to check its operation.
1) D23 indicates passage to the right and relay trip (PassOk1 - to the right).
2) D22 indicates passage to the left and relay trip (PassOk2 - to the left).
3) D24 is either constantly on indicating the "AP" command activation (in hold mode).

ВЗР.2499-00.00.000IM
Gate K-17
Installation Manual
19
Figure 5 –Gate control board.
Ошибка! Источник ссылки не найден.For connecting to ACS, wires
connected to gate control board are used, which are led out of gate housing as
various color harnesses:
1) Green harness is connected to the gate input signal group: LEFT -
white, RIGHT - green, STOP - blue, AP - red; black - GND.
2) Blue harness is connected to the output signal group indicating the
passages through the gate: PassOk1(R) COM –blue, NO - yellow,
PassOk1(L) COM –black, NO - red.
3) Yellow harness is connected to the output signals group: IO1 - yellow,
IO2 - black, IO3 - blue, IO4 - red.
4) Connector H16 for gate panel connection is led out of the gate
housing with RJ12 plug (G).
5) Connector X5 for 24V power connection is led out of the gate housing
by the red harness with wire cross-section of 2×0.75. Brown +24V, blue
GND
5.6 Control panel connection to the ACS controller
In some cases, the gate CP is be connected directly to the ACS controller,
since the system recognizes passages permitted from the control panel (without
using the controller) as "forced entry".
The use of this gate connection layout requires switching the control board
to the panel control off mode (see p. 5.2). With such setting, gate does not
respond to the control panel commands and just transmits their status to the IO1,
IO2, IO3, IO4 contacts of control board terminal blocks. (LEFT, RIGHT, STOP,
AP) being uncommitted collector outputs.
The contact assignment is shown in Table 2,

ВЗР.2499-00.00.000IM
Gate K-17
Installation Manual
20
Figure 6 –Numbering of the CP buttons For this group of contacts, maximum
output current shall not exceed 150mA, and permissible voltage shall not exceed
24V.
Control buttons
Figure 6 –Numbering of the CP buttons
Table 2 –ACCES OUT contact group assignment
Identification of contacts
Contact assignment
LEFT
"LEFT" button (1) status
RIGHT
"RIGHT" button (3) status
STOP
"STOP" button (2) status
АР
"AP" button (4) status
LEFT, RIGHT, STOP and АР outputs represent current status of the CP
buttons –the transistor opens when corresponding button is pressed.
This manual suits for next models
1
Table of contents
Other Oxgard Fencing & Gate manuals
Popular Fencing & Gate manuals by other brands

Feeney
Feeney DesignRail installation instructions

Atlantis
Atlantis NOVA II installation instructions

Casanoov
Casanoov VELETA KIT-000094 Assembly instructions

Zippity
Zippity Manchester Vinyl Picket Gate with Posts Assemble Instruction

Weka Holzbau
Weka Holzbau 670.0627.00.00 manual

Casanoov
Casanoov 300B140 manual