Oxgard MODELK-14 User manual

VOZROZHDENIE LLC
OKPD 27.90.40.190
ТУ 27.90.40-001-33120038-2018
APPROVED BY
ВЗР.248100.000LU
GATE
MODELK-14
ВЗР.248100.000OM
OPERATION MANUAL
32 sheets
2020

ВЗР.248100.000OM
Gate K-14
Operation Manual
2
CONTENTS
1Description and operation.............................................................................................................. 4
1.1 Product description and operation.......................................................................................... 4
1.2 Product indication panel......................................................................................................... 8
2Intended use.................................................................................................................................... 9
2.1 Operating limits ...................................................................................................................... 9
2.2 Preparing the product for use............................................................................................... 10
2.3 Product operation................................................................................................................. 13
2.4 Emergency procedures ........................................................................................................ 14
3Maintenance.................................................................................................................................. 16
3.1 General Provisions............................................................................................................... 16
3.2 Safety precautions................................................................................................................ 16
3.3 Product maintenance procedure........................................................................................... 17
3.4 Visual inspection of the product............................................................................................ 17
3.5 Checking the product components ....................................................................................... 17
3.6 Product functional check ...................................................................................................... 17
4Routine repairs.............................................................................................................................. 19
4.1 Routine repairs of the product .............................................................................................. 19
4.2 Routine repairs of the product components.......................................................................... 19
4.3 Malfunctions during warranty period..................................................................................... 19
5Storage .......................................................................................................................................... 20
6Transportation............................................................................................................................... 21
7Disposal......................................................................................................................................... 22
APPENDIX A —Distributors and service centers ............................................................................. 23
Abbreviations....................................................................................................................................... 29

ВЗР.248100.000OM
Gate K-14
Operation Manual
3
This Operation Manual (OM) applies to Oxgard gate K-14 and its
modifications (hereinafter referred to as the product).
The manufacturer reserves the right to change configuration, technical
characteristics and appearance of the product without further notice.
Before using the product, please read ВЗР.248100.000 Logbook (LB) as
well.
This OM is a document certifying the product’s basic parameters and
characteristics guaranteed by the manufacturer.
The Operation Manual is intended to instruct the user on the principle of
operation, structure of the product to correctly operate the product, fully utilize its
technical capabilities and maintain its constant readiness for operation.

ВЗР.248100.000OM
Gate K-14
Operation Manual
4
1 DESCRIPTION AND OPERATION
1.1 Product description and operation
Gate Oxgard K-14 motorized is designed to control access and1.1.1
manage people traffic.
The product can be used at checkpoints of enterprises, organizations and
banks, in educational institutions, sports and entertainment facilities, shops,
terminal stations and other institutions.
The structural components of the product are detailed in Table 1.1.1.2
Table 1 –Product components
Product designation
Product name
Quantity
Note
Gate
K-14
1
Control panel (CP)
Universal control panel
Praktika
1
Power supply source*
the ACS and OPS cables
Barrier section set*
Praktika barrier
Note - Product components marked with (*) are optional.

ВЗР.248100.000OM
Gate K-14
Operation Manual
5
The product specifications are given in Table 2.1.1.3
Table 2 –Product specifications
Parameter
Value
Overall dimensions of the gate with glass (W×H×L)
depending on the passage-way width, mm:
- 600 mm
- 800 mm
- 900 mm
- 1000 mm
- 1200 mm
800х1140х264
1000х1140х264
1100х1140х264
1200х1140х264
1400х1140х264
Overall dimensions of the gate with a metal tube flap
(W×H×L) depending on the passage-way width, mm:
- 600 mm
- 900 mm
- 1000 mm
- 1200 mm
810х1140х264
1110х1140х264
1210х1140х264
1410х1140х264
Weight of the gate with glass, kg at passage-way
width, mm:
- 600 mm
- 800 mm
- 900 mm
- 1000 mm
- 1200 mm
50,0
54,0
56,0
58,0
62,0
Weight of the gate with a metal tube flap, kg at
passage-way width, mm:
- 600 mm
- 900 mm
- 1000 mm
- 1200 mm
50,0
56,0
58,0
62,0
Temperature range, °С:
- operation
- transportation and storage
+1...+40
+1...+40
Relative humidity, %, max.
80
Width of formed passage, mm
600-1200

ВЗР.248100.000OM
Gate K-14
Operation Manual
6
Throughput, pers./ min
10
Service life, years
8
Supplied voltage, V
- rated
- operational
24,0
19,0...29,0
Average current in standby mode*, A
0,4
Average current in passage mode*, A
0,5
Maximum consumption current*, A
8,0
Note - * Values of current are given for rated supply voltage
ATTENTION: THE CAPACITY DATA WERE OBTAINED IN
EXPERIMENTAL TESTING AT 600 MM FLAP, WITH NO PAUSES BETWEEN
OPENING AND CLOSING.
Product structure.1.1.4
All gate structure members are made of polished stainless steel, the flap is
made of hardened glass.
The gate includes a stationary stand with an enclosure, floor mounting cup,
indication panel, upper rotary enclosure with electric drive and glass flap.
Gate flap rotation at 180° (+90°-90°) is available.
Figure 1 –gate overall view.

ВЗР.248100.000OM
Gate K-14
Operation Manual
8
Figure 2 –Gate overall dimensions for passage-way width of 600 mm
Marking contains manufacturer's trademark, designation and1.1.6
serial number.
Overall dimensions of packing case.1.1.7
Gate overall dimensions with glass, mm:
1) Gate with passage-way width of 600 mm –940х685х110;
2) Gate with passage-way width of 800 mm –985х940х110;
3) Gate with passage-way width of 900 mm –985х940х110;
4) Gate with passage-way width of 1000 mm –1080х940х110;
5) Gate with passage-way width of 1200 mm –1220х940х110.
1.2 Product indication panel
The gate has a three-color indication(Figure 1 –3, indication panel):
1) Green –passage is permitted (flap open);
2) Red –passage is forbidden (flap closed);
3) Yellow-green –powering initialization mode (during power supply).

ВЗР.248100.000OM
Gate K-14
Operation Manual
9
2 INTENDED USE
2.1 Operating limits
ATTENTION: FAILURE TO COMPLY WITH THE SAFETY
REQUIREMENTS SPECIFIED IN THIS SECTION CAN RESULT IN DEATH AND
DAMAGE TO HEALTH, COMPLETE OR PARTIAL LOSS OF PERFORMANCE
OF THE PRODUCT AND/OR AUXILIARY EQUIPMENT.
ATTENTION: THE PRODUCT SHALL BE INSTALLED BY
QUALIFIED PERSONNEL IN ACCORDANCE WITH INSTALLATION MANUAL
ATTENTION: THE CONTROL PANEL WORKS ONLY AT A
DISTANCE OF 5 METERS FROM THE GATE. THIS IS THE DISTANCE OF THE
STANDARD CABLE SUPPLIED WITH THE GATE.
ATTENTION: MANUFACTURER WAIVES ANY RESPONSIBILITY
FOR DEATH AND DAMAGE TO HEALTH, COMPLETE OR PARTIAL LOSS OF
PERFORMANCE OF THE PRODUCT AND/OR AUXILIARY EQUIPMENT IF
USER FAILS TO COMPLY WITH THE SAFETY REQUIREMENTS SPECIFIED
IN THIS SECTION, AND ALSO VOIDS THE PRODUCT WARRANTY.
DO NOT:

ВЗР.248100.000OM
Gate K-14
Operation Manual
10
INSTALL THE POWER SUPPLY MODULE INSIDE THE PRODUCT BODY
AS IT MAY RESULT IN ELECTRIC SHOCK TO PERSONS.
INSTALL THE PRODUCT OUTSIDE DRY AND HEATED ROOMS.
OBSTRUCT OR ACCELERATE THE PRODUCT FLAP MOVEMENT
WHEN TURNING ON (OFF) THE ANTI-PANIC MODE.
APPLY PASTES AND LIQUIDS CHEMICALLY AGGRESSIVE TO
MATERIALS OF THE HOUSING WHEN CLEANING THE PRODUCT.
2.2 Preparing the product for use
2.2.1 Safety measures during product preparation
ATTENTION: TO AVOID INJURIES TO PERSONS AND PRODUCT
BLOCKING, MAKE SURE THAT THERE ARE NO PERSONS AND FOREIGN
OBJECTS WITHIN THE FLAP ROTATION AREA PRIOR TO THE PRODUCT
CONNECTION.
2.2.2 Rules and procedures for visual inspection of the product
Visual inspection of the product before connecting to the mains shall be
obligatory and include:
1) check for product housing mechanical damage: cracks, through holes resulted
from fasteners drop-out;
2) thorough inspection of all connections of the product.
2.2.3 Turning on the product.
Connect the PSU to ~220 volts mains and turn it on. When turned on, the
indication panel lights in yellow-green, calibration takes place. The product flap

ВЗР.248100.000OM
Gate K-14
Operation Manual
11
shifts to the end position (the indication panel is displayed in red –stop mode).
Calibration is complete, the product is ready to work.
When turning the product on, make sure that the control panel is working at
the required data transfer rate of 1 Mbit.
If the panel is set correctly to 1 Mbit, when the gate turns on, all LEDs shall
light on the panel, and the gate shall start calibration: the gate flap opens and
moves to the end position, then goes to the middle position. Then, press the
STOP button, all buttons except STOP will go out. Gate is ready for operation.
If the panel is set incorrectly (wrong frequency), the buttons will not light up when you
turn on the gate. Set the panel to a different frequency. To do this:
1) Turn the gate power on;
2) Press and hold left (1) and right (3) buttons until the LEDs on the left (1) and right (3)
buttons blink.
3) Press and release the stop (2) button.
4) Press and release the right (1) button.
5) Press and release the anti-panic (2) button a few times until indication on the gate lights
up.
6) Reload the gate. All buttons on the panel will light up. Then, press and release the
STOP button.
ATTENTION: There is a new panel modification where it will beep three times
when connected to the gate, and set the required panel rate.

ВЗР.248100.000OM
Gate K-14
Operation Manual
12
2.2.4 Control panel settings
Figure 3 –CP appearance. The product can be installed in different ways
relative to the user. In some cases, it is necessary to swap left/right passage
buttons. This can be done using the following procedure:
1) Turn power on;
2) Press and hold left (1) and right (3) buttons until the LEDs on the left (1) and right (3)
buttons blink. Turn power on;
3) Press and release the stop (2) button;
4) Press and release the left button (1).
Now when LEFT button is pressed, it will be allowed to pass to the right
and vice versa. Current button assignment is stored and not reset when the power
is turned off. To return to the initial setting, repeat the above sequence of
operations.
Figure 3 –control buttons 1 (LEFT), 2 (STOP), 3 (RIGHT), 4 (ANTI-PANIC)
and LED indicators of the product operating modes.
Figure 3 –Control panel appearance
1 –left; 2 –stop; 3 –right; 4 - anti-panic

ВЗР.248100.000OM
Gate K-14
Operation Manual
13
2.3 Product operation
2.3.1 Product operating modes
Product can operate in several modes. Desired mode can be enabled
using the CP or ACS. The indication of the operation modes is displayed on the
panel in the form of mnemonic signs depicting authorization and non-authorization
of passage. The product operation on the ACS basis is described in the IM.
2.3.2 Product operation from the control panel
Figure 3 –over every product button.
Gate calibration mode
The gate calibration mode starts every time the gate is turned on. In this
mode, the gate’s LED indication lights up in yellow color, the gate flap is driven
clockwise until the variable inductance transducer actuates, then the flap moves to
the middle position.
STOP mode
The "STOP" mode is set when the product is turned on. For switching to
the STOP mode from any other mode, press button 2; the LED indicator over
button 2 lights red. The passage in either direction is prohibited in this mode.
LED indication lights in red.
The gate glass may be deflected from its initial position to a small angle,
within 5 degrees.
One-time passage mode
Button 1 (3) enables one-time passage mode to the left (right). When this
mode is enabled, one pass to the left (right) will be allowed, followed by entering

ВЗР.248100.000OM
Gate K-14
Operation Manual
14
the STOP mode. LED indication lights in green. The gate will open to the preset
side.
On the CP, the LED indicator lights green over the permitted passage
direction button and red over button 2. If a pass has not been completed within 10
seconds, the product is automatically switched to "STOP" mode.
Antipanic mode
For switching to this mode from any mode, press button 4.
LED indicator of control panel over button 4 lights yellow. LED indication
blinks in green.
On the command, the gate goes to the position determined by J2, and
remains in that position for 20 minutes, then returns to the closed position.
Gate operation in emergency situations:
If any object obstructs the flap movement during gate closure, the flap will lightly
hit it three times, then return to the position where it started movement.
If you try an unauthorized opening of the gate in the “Stop” mode in any
direction, the gate will not let you do it, and indication will be blinking in red.
2.4 Emergency procedures
To open passageway in emergency situation, use the ANTI-PANIC mode:
in this mode, the product flap will be open and passageway will be free.
ATTENTION: WHEN OPERATING THE PRODUCT, NOTE THAT
ELECTRIC CIRCUIT CAN BE A SOURCE OF FIRE DANGER IN CASE OF
SHORT CIRCUIT, INSULATION BREAKDOWN AND SPARKING.

ВЗР.248100.000OM
Gate K-14
Operation Manual
15
In case of fire, switch external power supply off. Use powder extinguishers
to extinguish fire in the product, wiring and cables.

ВЗР.248100.000OM
Gate K-14
Operation Manual
16
3 MAINTENANCE
3.1 General Provisions
Maintenance (hereinafter referred to as MNT) of the product shall be
carried out in accordance with this Operation Manual.
3.1.1 To maintain product performance and ensure design service life,
periodical in-service product MNT shall be performed, including during warranty
period.
3.1.2 Scheduled maintenance shall be performed once a year. If a
fault occurs, maintenance should be performed immediately after troubleshooting.
3.1.3 Maintenance is recommended to be performed by two persons
who are qualified mechanical and electromechanical specialists (or electricians),
at least category 3, and who have read and understood this Operation Manual.
3.2 Safety precautions
When performing maintenance, safety measures shall be observed.
Maintenance shall be performed by specially trained technical personnel.
DO NOT:

ВЗР.248100.000OM
Gate K-14
Operation Manual
17
PERFORM ANY WORK WITH THE PRODUCT POWER ON. FAILURE TO
COMPLY WITH THESE SAFETY REQUIREMENTS CAN RESULT IN DEATH
AND DAMAGE TO HEALTH, COMPLETE OR PARTIAL LOSS OF
PERFORMANCE OF THE PRODUCT AND/OR AUXILIARY EQUIPMENT.
REMOVE ELECTRIC BOARD FROM ITS MOUNTS. OTHERWISE, THE
MANUFACTURER’S WARRANTY WILL BE VOID.
3.3 Product maintenance procedure
Maintenance includes the following scope of work:
1) visual inspection of the product condition;
2) checking the fastening of product parts and components;
3) general check of the product operation.
3.4 Visual inspection of the product
3.4.1 Visually inspect the product. There should not be visible damage
on the product.
3.5 Checking the product components
3.5.1 Clean the load-bearing frame from dirt.
3.5.2 Check that all cables are securely attached.
3.5.3 Check threaded connections of the product components; tighten,
where necessary.
3.6 Product functional check
For functional check, perform several test passes.
If no any abnormal noises and operational disturbances are detected, the
product is ready for operation.

ВЗР.248100.000OM
Gate K-14
Operation Manual
18
If any defects in the product components are found during the product
MNT, we recommend to contact service department for advice.
List of addresses of official distributors and service centers is given in
Appendix A and is also available on website: www.oxgard.ru

ВЗР.248100.000OM
Gate K-14
Operation Manual
19
4 ROUTINE REPAIRS
4.1 Routine repairs of the product
No routine repairs are provided for the product. When any fault listed in
Table 3 occurs, follow the procedures below.
Table 3 –Typical product malfunctions
Malfunction
Action
PSU is connected, but product
does not work
Check if the cables are connected correctly;
Check the fuse on the motherboard.
The CP doesn't work
Check if CP is connected correctly.
If +24 and GND terminals are connected correctly, try to
swap the CL and CH terminals.
When any other problems occur, contact the service department.
4.2 Routine repairs of the product components
Routine repairs of the product components shall be carried out by replacing
faulty parts with known good ones.
When such replacement is impractical or there are no known good
components available for the product, a proprietary repair method shall be used.
4.3 Malfunctions during warranty period
When malfunction occurs during warranty period (Logbook
ВЗР.248100.000 (LB)), please send a claim to the manufacturer. To do this:
1) prepare a technically substantiated Claim Report;
2) make extracts from the LB section "Repair".
3) make extracts from the LB section "Preservation".

ВЗР.248100.000OM
Gate K-14
Operation Manual
20
5 STORAGE
The product shall be stored in dry (without moisture condensation) heated
rooms at a temperature from +1 to + 40°C. The storage room should be free of
acid or alkali vapors, or corrosive gases.
The short time product storage in original package shall be permitted for
maximum 3 days in dry unheated rooms and enclosed transport bodies.
After storage in unheated rooms, prior to commissioning, the product shall
be kept in a room with normal climatic conditions for 12 hours.
Table of contents
Other Oxgard Fencing & Gate manuals
Popular Fencing & Gate manuals by other brands

Ameristar
Ameristar TransPornt II instructions

Fortress Technologies
Fortress Technologies PURE VIEW GLASS BALUSTER AL13 HOME installation instructions

Betafence
Betafence Mobile Fence installation manual

XCEL
XCEL UNIVERSAL POST installation guide

EUROLAIKAS
EUROLAIKAS BC Series instruction manual

Casit
Casit MR300/CRM200 manual

Fontanot
Fontanot magia.xtra manual

Casanoov
Casanoov KIT-000082 Assembly instructions

Jewett-Cameron
Jewett-Cameron Adjust-A-Gate CONTRACTOR Series Assembly instructions

Vente Unique
Vente Unique UV08-5 manual

Qimarox
Qimarox Securyfence Assembly instructions

Zippity
Zippity ALL AMERICAN VINLY PICKET GATE ZP19043 Assembly instructions