© 2014 - 2024 Parktron Technology Ltd.
© 2014 - 2024 Parktron Technology Ltd.
(A)
220V(110V) power connection:
Remove wiring terminal cover and connect power wire to [Power input
interface board].
(B)
Traffic light (R&G light) connection:
The traffic light connector provides 220v power. Connect the Red
Light Wire, Green Light Wire and COM wires to the [R&G light output
interface board] according to text indication printed on the board.
(C)
Photocell emitter and receiver connection:
To use photocell device, first connect photocell (emitter and receiver)
to wiring terminal power output [Photocell power output], and then
connect receiver signal wire to signal input [Photocell signal input] on
wiring terminal board.
(D)
Loop detector terminal:
This controller can support both the internal and the external loop
detector connections.
However, just one way can be chosen.
If external loop detector is selected, just connect the loop detector
to 220V power, and connect the signal wire to the signal input
terminal.
If the internal loop detector is selected, connect the internal loop
detector to the socket on the circuit board directly and the signal
wire to vehicles detector signal input terminal.
(E)
"COM","UP","DOWN","STOP" signal input terminal:
The input terminal can work as a switch. If choose the "UP",
"DOWN","STOP" input terminal to connect to the "COM" by a
wire, the main board will give the correlative reaction signal to the
barrier gate arm.
The user can use this method for the IC system controlling or the
circuitry controlling.(Note: the wire control is advised to be used
in the guards' room)
(F)
"UP" and "DOWN" position limit switch:
This switch transmits the "UP" and "DOWN" command to boom by
optical signal.(Notice: More details please refer to Fig.12)
(G)
RS485 serial communication terminal:
The main board supports the Rs485 serial communication to control
the boom UP and DOWN. Please link the computer with Rs485
interface by the communication module.
The software please refer to the instruction in the disk.(Optional
device)
(H)
Terminal special for motorcade:
If the users have installed the loop detector, and do not want the
barrier boom fall down automatically when there are still some cars
in line behind the passing car. Then please add an exterior circuit
to this device. If the circuit is on, the loop detector will work; if
the circuit is off, the loop detector will not work.
Electric part adjustment and attentions
(A)
Barrier gate controlling:
There are three buttons to control the barrier gate conveniently
when the barrier gate sets well.
If the boom can not fall down or rise up to the right position, or
rises up automatically after reaching the horizontal position, please
check whether the abnormal situation is caused by loop detector
or not.
If the abnormal situation mentioned above is not caused by loop
detector, please check the "Gate Type Selection "setting.
(Note: the barrier gate speed has been fixed. And this "Gate Type
Selection" is just for controller adjustment to keep its' working
speed accord with the barrier gate speed.) The "Gate Type
Selection has been well set before leaving our factory, but user
can adjust
it if needed.
(B)
Boom backtrack function:
The boom will rise up if it comes across obstacles when falling.
And it will stop if it hits something when rising.
(C)
Infrared photocell function:
If the infrared signal is cut off when the boom is falling, the boom
will rise up automatically.
(D)
R&G light terminal:
The light will turn green only when the boom is at the vertical
position. Red light is for other positions.
(E)
Loop detector terminal:
If the vehicles detector is installed correctly, the boom will
automatically rise up when there is some press of the vehicle on the
loop, and it will automatically fall after the vehicles leaves the loop.