PBI DXP-3800D User manual

DXP-3800D
- 1 -
Professional 8-in-1 TS Processor
User Manual
http://www.pbi-china.com

DXP-3800D
- 2 -
Contents
1. Overview......................................................................................................................- 5 -
2. Features.......................................................................................................................- 5 -
3. Technical Specifications............................................................................................- 6 -
4. Front panel and rear panel instructions ................................................................- 10 -
4.1 Front panel.........................................................................................................- 10 -
4.2 Rear panel..........................................................................................................- 10 -
4.3 RS-232 Serial Port............................................................................................- 11 -
4.4 Management Ethernet Port.............................................................................- 11 -
4.5 TS over IP Ethernet Port..................................................................................- 12 -
5. Operation...................................................................................................................- 13 -
5.1 Local Control......................................................................................................- 13 -
5.1.1 Getting Started.......................................................................................- 13 -
5.1.2 Main menu..............................................................................................- 13 -
5.1.3 Configuration Menu...............................................................................- 14 -
5.1.5 System menu .........................................................................................- 15 -
5.2 Remote Control(Web).................................................................................- 17 -
5.2.1 Status.......................................................................................................- 17 -
5.2.2 Configuration..........................................................................................- 18 -
5.2.2.1 Configuration-Tuner...........................................................................- 19 -
5.2.2.2 Configuration-CI .................................................................................- 20 -
5.2.2.3 Configuration-Biss..............................................................................- 20 -
5.2.2.4 Configuration-ASI Output..................................................................- 21 -
5.2.3 Remux.....................................................................................................- 22 -
5.2.4 TS/IP........................................................................................................- 23 -
5.2.4.1 Gigabit Local.......................................................................................- 23 -
5.2.4.2 Gigabit Out..........................................................................................- 23 -
5.2.4.3 Gigabit In .............................................................................................- 24 -
5.2.5 System.....................................................................................................- 25 -
6. Firmware Update......................................................................................................- 29 -
6.1 Firmware Upgrade from USB Key..................................................................- 29 -
6.2 Firmware Upgrade by FTP..............................................................................- 29 -
6.3 Firmware Upgrade from WEB.........................................................................- 32 -
7. Installation..................................................................................................................- 33 -
8. Accessories ...............................................................................................................- 33 -

DXP-3800D
- 3 -
Notices
COPYRIGHT (Copyright © 2013 Beijing Jaeger Communication Electronic Technology Co., Ltd.)
Not to be copied, used or translated in part or whole without Beijing Jaeger prior consent in writing
except approval of ownership of copyright and copyright law.
WARRANTY
This warranty does not cover parts which may become defective due to misuse of the information
contained in this manual.
Read this manual carefully and make sure you understand the instructions provided. For your safety,
be aware of the following precautions.
WARNING! IMPORTATNT SAFETY INSTRUCTIONS
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE
COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER
SERVICING TO QUALIFIED SERVICE PERSONNEL.
WARNING
• To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
• To avoid explosion danger, do not dispose of batteries in an open fire.
CE MARK FOR EUROPEAN HARMONISED STANDARDS
The CE mark which is attached to these products means it conforms to EMC
Directive (89/336/EEC) and Low Voltage Directive (73/23/EEC).
IMPORTANT INFORMATION
Please retain the original packaging, should it be necessary at some stage to return the unit.
Disposal of Old Electrical and Electronic Equipment (Applicable in the European Union and
other European countries with separate collection systems)
This symbol on the product or on its packaging indicates that this product shall not
be treated as household waste. Instead it shall be handed over to the applicable
collection point for the recycling of electrical and electronic equipment. By
ensuring this product is disposed of correctly, you will help prevent potential
negative consequences for the environment and human health, which could
otherwise be caused by inappropriate waste handling of this product. The
recycling of materials will help to conserve natural resources. For more detailed
information about recycling of this product, please contact your local Civic Office,
your household waste disposal service, or the shop where you purchased the
product.
COPYRIGHTS
Television programs, movies, video tapes, discs, and other materials may be copyrighted.
Unauthorized recording of copyrighted material may be against the copyright laws in your region.
Also, use of this product with cable television transmissions may require authorization from the cable
television operator or transmitter/owner.
VENTILATION
• Do not expose the product to high temperatures, such as placing it on top of other product that
produce heat or in places exposed to direct sunlight or spot lights.
• The ventilation slots on top of the product must be left uncovered to allow proper airflow into the
unit.
• Do not stand the product on soft furnishings or carpets.
• Do not stack electronic equipment on top of the product.
• Do not place the product in a location subject to extreme changes in temperature. The
temperature gradient should be less than 10 degrees C/hour.
• Place the product in a location with adequate ventilation to prevent the build-up of heat inside the
product. The minimum ventilation space around the unit should be 7 cm. The ventilation should
not be impeded by covering the ventilation openings with items, such as newspapers, table cloth,
curtains, etc.

DXP-3800D
- 4 -
POWER SOURCES
• The product is not disconnected from the AC power source (mains) as long as it is connected to
the power outlet or wall socket, even if the product is turned off.
• If the product will not be used for a long period of time, disconnect it from the AC power outlet or
wall socket.
Before Using the Device
Thank you for purchasing the DXP-3800D Professional 8-in-1 TS Processor. This User Manual is
written for operators/users of the DXP-3800D to assist in installation and operation. Please read this
user manual carefully before installation and use of the device.
FOR YOUR SAFETY
This equipment is provided with a protective earthing ground incorporated in the power cord. The
main plug shall only be inserted in a socket outlet provided with a protective earth contact. Any
interruption of the protective conductor, inside or outside the device, is likely to make the device
dangerous. Do not remove the covers of this equipment. Hazardous voltages are present within this
equipment and may be exposed if the covers are removed. Only Beijing Jaeger trained and approved
service engineers are permitted to service this equipment.
The supplied AC power cable must be used to power the device. If the power cord becomes
damaged it must be replaced. No operator serviceable parts inside. Refer servicing to Beijing Jaeger
trained and approved service engineers. For the correct and safe use of the device, it is essential
that both operating and servicing personnel follow generally accepted safety procedures in addition
to the safety precautions specified in this manual. Whenever it is likely that safety protection is
impaired, the device must be made in-operative and secured against unintended operation. The
appropriate servicing authority must be informed. For example, safety is likely to be impaired if the
device fails to perform the intended measurements or shows visible damage.
WARNINGS
• The mounting environment should be relatively dust free, free of excessive vibration and the
ambient temperature between 0C° to 40C°. Relative humidity of 20% to 80% (non-condensed) is
recommended.
• Avoid direct contact with water.
• Never place the equipment in direct sunlight.
• The outside of the equipment may be cleaned using a lightly dampened cloth. Do not use any
cleaning liquids containing alcohol, methylated spirit or ammonia etc.
• For continued protection against fire hazard, replace line fused only with same type.
• Air intake for cooling is achieved via holes at the side of the device and the fans inside. The air
flow should not be obstructed. Therefore, the device has to be placed on a flat surface, leaving
some space at the sides of the device.
• When in operation, the internal temperature should not exceed the limit of 70C°.

DXP-3800D
- 5 -
Professional 8-in-1 TS Processor
1.Overview
DXP-3800D is a high-density, modular and CI decryption professional TS processor equipped with
8 independent tuners, which can be either of DVB-T/T2, DVB-S2/S, DVB-C, DTMB, ISDB-T and
ATSC types. It supports a wide range of application by combining 8 tuners processing capability
with industry standard outputs including ASI and TS/IP. DXP-3800D has 8 DVB common interface
slots capable of working with most of well-known CAS in the market to de-crypt multiple pay TV
services. DXP-3800D provides operators an ideal solution for multi receiving, re-multiplexing,
descrambling and TS over IP operations, the compact 8 tuners and the powerful 8 CI decryption
design make DXP-3800D one of the most competitive product in the head-end market.
2.Features
8 x Tuners Input, Supports variety of input options DVB-T2/T/S2/S/C/DTMB/ATSC/ISDB-T
Supports DVB-S2 Input Stream Identifier (ISI, optional) and DVB-T2 Multi PLP and SFN
MIP pass through
Built-in TS re-multiplexer receives from CI Slot1 to CI Slot8 and TS/IP inputs
8×DVB-CI Slots, multi-program decryption, BISS-1 and BISS-E decryption
8xASI output the transport stream from CI Slot1 to CI Slot8 or BISS decryption
1xchannel full duplex TS over IP ,9xchannels MPTS IP out without IP input or 128xchannels
SPTS IP out without IP input
Remote Control and Supervision by SNMP v2, HTTP WEB and Proprietary HDMS software
On Site software update through IP or USB
RSSI, received signal strength, Eb/N0, C/N and BER monitoring
Redundency power supply

DXP-3800D
- 6 -
3.Technical Specifications
Tuner Input
DVB-S/S2 Tuner Input (ISI Factory Optional)
Connector Type
8×F type female 75Ω for Input
Input Frequency Range
950 ~ 2150MHz
Input Level
-25 ~ -65dBm
Symbol Rate
2 ~ 45MBaud
Roll-off Factor
DVB-S QPSK: 0.35
DVB-S2 8PSK: 0.35, 0.25, 0.2
FEC Code Rate
DVB-S QPSK: 1/2, 2/3, 3/4, 5/6, 7/8
DVB-S2 QPSK: 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 8/9,9/10
DVB-S2 8PSK: 3/5, 2/3, 3/4, 5/6, 8/9, 9/10
LNB Polarity Selection Voltage
0, 13V, 18V selectable
LNB Band Selection Tone
0/22KHz selectable
Satellite Selection Command
DiSEqC 1.0
ISI ID
1 ~ 255 user configurable
DVB-C Tuner Input
Connector Type 8×F type female 75Ω for Input
Input Frequency Range
51 ~ 862MHz
Input Level
51 ~ 75dBμV
Symbol Rate
1 ~ 7MBaud (ITU J.83 Annex A)
Constellation
16QAM, 32QAM, 64QAM, 128QAM, 256QAM
Bandwidth
6MHz, 7MHz, 8MHz
Input Return Loss
7dB (typ.)
DVB-T/T2 Tuner Input
Connector Type
8×F type female 75Ω for Input
Input Frequency
104 ~ 862MHz (VHF/UHF)
Input Level -20 ~ -70dBm
Constellation
DVB-T: QPSK, 16QAM, 64QAM
DVB-T2: QPSK, 16QAM, 64QAM, 256QAM
Bandwidth
6MHz, 7MHz, 8MHz
FFT Mode
DVB-T: 2K, 8K

DXP-3800D
- 7 -
DVB-T2: 1K, 2K, 4K, 8K, 16K, 32K
Guarding Interval
DVB-T: 1/4, 1/8, 1/16, 1/32
DVB-T2: 1/4, 5/32, 1/8, 5/64, 1/16, 1/32, 1/64, 1/128
FEC Code Rate
DVB-T: 1/2, 2/3, 3/4, 5/6, 7/8
DVB-T2: 1/2, 3/5, 2/3, 3/4, 4/5, 5/6
Input Return Loss
7dB (typ.)
DTMB Tuner Input
Connector Type
8×F type female 75Ω for Input
Input Frequency Range
46.5~866MHz
Input Level
-87~-29dBm
Symbol Rate
7.56MBaud
Bandwidth
6MHz/7MHz/8MHz
Constellation
4QAM-NR,4QAM,16QAM,32QAM,64QAM
Guard Interval
PN420, PN595, PN945
Roll-off Factor
0.05
Interleaving Depth
240,720
FEC Code Rate
0.4, 0.6, 0.8
ATSC Tuner Input(compatible with ITU J.83 Annex B)
Connector Type
8×F type female 75Ω for Input
Input Frequency Range
54~864MHz
Input Level
-75~-7dBm(ATSC 8VSB)
Symbol Rate
10.762MBaud
Constellation
8VSB
Roll-off Factor 0.115
Bandwidth
6MHz
TS Processing
TS Input Management
Demux and Remux among IP Input and CI1 to CI8 Input
TS Output Management
ASI1 to ASI8 output directly pass through the TS from CI1
to CI8,
Demux and Remux for ASI9, ASI10 output and IP output
Service and PID Management
Service and PID level for Remux
PSI/SI PSI/SI table regeneration, NIT and SDT edition, LCN
Edition and Re-generation
Descrambler
DVB Common Scrambling Algorithm (CSA)
BISS Mode
BISS-1, BISS-E

DXP-3800D
- 8 -
Common Interface 8 x PCMCIA slots, compatible with major CA CAMs in the
market
ASI Output
Connector Type
Daughter Board: 8xBNC female, independence output,
75Ω,
Main Board: 1 pair of BNC female, mirror output, 75Ω,
Standard
DVB-ASI, EN50083-9
Output Bit Rate
≤ 200Mb/s
TS Processing
Daughter Board: ASI1 to ASI8 out pass through the TS
from CI 1 to CI8,
Main Board: ASI9 and ASI10 out from Remux
TS over IP
Connector Type
1×RJ-45, 100/1000 Base-T
Effective Bit Rate
Support 3 different mode(need to reboot unit if change the
TS/IP mode):
1. Max.430Mb/s for 9xchannels(8xchannels directly pass
through the TS from CI1 to CI8, 1xchannel output the TS
from Remux) MPTS IP out without IP in,
2. Max.430Mb/s for 128xchannels SPTS IP out the TS from
one source, without IP in,
3. Max.80Mb/s for full duplex 1xchannel MPTS
Protocol
UDP/RTP, Multicast/Unicast, IGMPv3, ARP
Alarm
Connector Type
1×D-sub 9 male
Switching Condition User Defined
Control & Monitoring
Connector Type
1×RJ-45, 10/100 Base-T, for equipment IP Control
Remote Control SNMP, HTTP (Web Interface), Proprietary HDMS (Headend
Device Management System)
Local Control LCD display and 6-key keypad
Serial Port
1×RS-232 D-sub female, for debug use only
Equipment Upgrade
USB,WEB http and FTP
Physical
物理规格
Dimension
505mm x 445mm x 45mm
Weight 7.9kg
Power Supply
AC 90V ~ 250V, 50/60Hz

DXP-3800D
- 9 -
Power Consumption
30W (exclusive of LNB power)
Operating temperature
0 ~ 45℃
Storage temperature
-10 ~ 60℃
Operating Humidity
10 ~ 90%, non-condensed
Certification
EMC:
EN 55024:1998+A1:2001+A2:2003, EN 55022:2006+A1:2007, EN 61000-3-2:2006, EN
61000-3-3:2008
FCC:
Part 15 Class B
LVD:
EN 60950-1:2006 + A11:2009
* For more information about digital audio pass through, please contact our sales representative.

DXP-3800D
- 10 -
4. Front panel and rear panel instructions
4.1 Front panel
Name Function
LED Power When turned on, the Green LED indicates that power is available. When
turned off, the power is not available or failed
LED Warning LED ON:
LED OFF:
LED Alarm
LED ON: Alarm or alarms happen to the equipment, For alarm description,
please refer to details in the table 10.
LED OFF: The equipment works properly
LED Tuner Lock
LED ON: Tuner input is locked,
LED OFF: Tuner is un- locked.
LCD Display Display menus, submenus and its parameters
Cursor Keys UP, DOWN, LEFT, RIGHT. Used to navigate through the menu system
ENTER key Confirm a selection then return to previous menu
EXIT Key Exit and return to previous menu
Control RJ-45 Ethernet port for equipment control and supervision
Control USB port for firmware upgrade
TS/IP RJ-45 TS over IP port
4.2 Rear panel

DXP-3800D
- 11 -
Name Description
Alarm
RS-232 Serial port for equipment debug use
Tuner In-1/4 Tuner signal input port 1~4
ASI Out-1/4 ASI Output ports in mirror 1~4
Common Interface To insert CI CAM modules, maximum two CI modules 1~4
Tuner In-5/8 Tuner signal input port 5~8
ASI Out-5/8 ASI Output ports in mirror 5~8
Common Interface To insert CI CAM modules, maximum two CI modules 5~8
ASI Out-9/10 ASI Output ports in Remux 1~2
Power Supply Double Power Supply,AC 90~250V 50-60Hz input
4.3 RS-232 Serial Port
The RS-232 port is used for equipment software debug use, its pin definition is shown in the table.
The parameter settings are:
●No Parity bit
●38400 Bauds
●8 data bits
●1 Stop bit
Pin Pin Function
1
N.C.
2
TXD
3
RXD
4
N.C.
5
GND
6 N.C.
7 N.C.
8 N.C.
9 N.C.
4.4 Management Ethernet Port
The Management port is used to remote control and supervise the equipment through IP, it’s also for
the software update. Its factory setting is as following:
IP address:10.10.70.48
Sub Mask:255.255.255.0
Gateway:10.10.70.1

DXP-3800D
- 12 -
Both web based control software and proprietary HDMS software are using this port.
Notice: When apply default setting to DXP-3800D, the above settings for IP will not be affected, this
is for maintaining the connectivity of the unit to the IP Network.
4.5 TS over IP Ethernet Port
The TS over IP port is an option by adding the daughter board inside the rack. The default setting is
as following:
IP address:10.10.10.10
2nd IP address: 10.10.10.20 (for option DCH-5100P-32x, if equipped)
Sub Mask:255.255.255.0
Gateway:10.10.10.1
Depending on the option selected by the customer, this TS over IP port is either 10/100 Base-T or
100/1000 Base-T compliant to the IEEE 802.3 specifications.

DXP-3800D
- 13 -
5. Operation
5.1 Local Control
5.1.1 Getting Started
After successful installation and connection of the Professional IRD Processor DXP-3800D, switch on
the power supply. The equipment will check the hardware and software versions, then the product
name and its IP address will be shown in the LCD screen.
The IP address of the equipment can be changed in the System menu. Go into the Network Setting
submenu, user can set IP address, network mask and IP gateway, press ENTER to select the option,
and use LEFT or RIGHT to move the cursor between digits and use UP or DOWN to change the
value until the right value, then press ENTER to make the selection.
Customers can use UP, DOWN, LEFT,RIGHT, ENTER, EXIT keys from front panel to navigate in the
menus, select and confirm the parameters in LCD screen.
5.1.2 Main menu
User can press ENTER into the main menu. In the main menu, there are 3 sub-menu, Press
UP/DOWN to switch between the sub-menus.
Professional IRD
IP: 10.10.70.48
IP Address
10.10.70.48
Network Mask
255.255.255.0
Gateway
10.10.70.1

DXP-3800D
- 14 -
●Status
●Config
●System
After go into every sub-menu, you can press LEFT or RIGHT to move the cursor, then use UP or
DOWN to change the value, and then you can press ENTER to make the selection.
Submenu Name Description
Status Monitor the parameters of Tuner RSSI, Input Bitrate, Output Bitrate, TS over
IP input (only when the TS/IP streaming board is installed) information.
Config Configure the parameters of Tuner setting, CI settings, BISS setting, Remux
setting, ASI output and so on.
System Check and set system settings and read the equipment information, and
make the default factory setting and so on.
5.1.3 Configuration Menu
In the Configuration menu, user can configure and monitor the parameters of input and output,
including Tuner, CI settings, AV decoder, ASI output, BISS, SDI, TS over IP input (only when the
TS/IP streaming board is installed) and so on. Choose Configuration and press UP or DOWN to
scroll the sub-menus, press ENTER to go into the sub-menus. There are ten sub-menus to configure:
●Slave Board Setup (Tuner1~8 setting)
●CI
●BISS
●Remux
●TS/IP
●ASI Out
Submenu Name Description
Slave Board Setup
Tuner
Tuner-1
Tuner-2
Tuner-3
Tuner-4
Tuner-5
Tuner-6
Tuner-7
Tuner-8
LNB LO
Frequency
To configure the local oscillator frequency
according to the right satellite, its range is from
5150 to 11,300MHz.
Satellite
Frequency
To configure the satellite down link frequency
according to the right satellite, its range is from
1000 to 26,500MHz.
Symbol Rate To configure the symbol rate of QPSK signal, its
range is from 1000 to 45,000KBaud.
LNB Voltage To select the correct LNB voltage output from the
F-connector, user can choose between Off, 13V
and 18V.

DXP-3800D
- 15 -
LNB 22KHz To activate the LNB 22KHz control signal to the
LNB, user can select between On and Off.
DiSEqC To configure the DiSEqC control, user can select
Port A, Port B, Port C, Port D or DiSEqC OFF.
CI
CI-1(~8)
CI CAM Name
To check what kind of CAMs have been inserted.
CI Setup To set which programs should be descrambled by
CI slot1 or CI slot2.
BISS
BISS-1(~8)
BISS Mode To select the BISS mode, user can choose
between Off, BISS-1 and BISS-E.
ID and Key Input Key value in BISS-1 mode and input ID and
Key in BISS-E mode.
Program To select which services will be decrypted by
BISS.
Remux
Program select
To setting Remux.
Bit Rate
To set the Max bit rate of the Remux output.
Packet Size To choose 188Byte or 204Byte for the Packet
Size.
TS ID
To set the TS ID.
Remove CA
To choose Off or On for the Remove CA
Insert EIT
To choose Off or On for the Insert EIT
ON ID
To configure the Original Network ID.
Output Program
To select which services will be output by Remux.
TS/IP
Bypass
ASI Out
Bypass
5.1.5 System menu
In this menu, you can check and set system settings and read the equipment information, and make
the default factory setting and so on. There are nine submenus, including Version Info, IP Control,
Product Name, Model, Factory Settings, Machine Type, LCD Language, Safety Level, and Upgrade.
Use UP or DOWN key to scroll the submenu, and press ENTER to go into each submenu.
●Network Setting
●Product Name
●Version
●Factory Settings

DXP-3800D
- 16 -
●Machine Type
●Web Login
●Gigabit Mode
Submenu Name Description
Network Setting
IP Address
To configure the IP Address of the device.
Network Mask
To configure the IP Net Mask of the device.
Gateway
To configure the IP Gateway of the device.
MAC Address
To display the MAC address of the device
Product Name
To configure the product name of the device.
Version Info
To display some properties of the device, such as software version.
Factory Settings
The switch to make factory default setting.
Machine Type
Password
Bypass
MAC Address
To configure the MAC address of the device.
S/N
To configure the serial number of the device.
External Board MAC
To configure the MAC address of the device.
Web Login HTTP Login To configure the user name and password of
web access.
Gigabit Mode
To choose Gigabit mode (IPTV, Full Duplex, Multiple Output)

DXP-3800D
- 17 -
5.2 Remote Control(Web)
DXP-3800D can be controlled by WEB. User can type IP address of DXP-3800D in
browser. It will show login pop-up. The default user name is root and password is
12345. If you forget this username and password, you can use front panel button to
change it. You can set it in SystemHTTP login menu.
5.2.1 Status
User can monitor the status of input, output, Tuner and TS/IP. All information of
every input source can be shown in this page. The output status and information
can also be checked.
Input Bitrate—User can monitor TS status of TS(1~8)and IP IN here.
Output Bitrate—User can monitor video and audio decoding status here.

DXP-3800D
- 18 -
Tuner Status—User can Tuner signal status here.
TS/IP Status—User can TS over IP status here.
5.2.2 Configuration
Set parameters of tuner input, CI, Biss and ASI Output.

DXP-3800D
- 19 -
5.2.2.1 Configuration-Tuner
Tuner(1~8)
It is used to lock the right satellite. The description of parameters is shown in
below. Click “Apply” button to submit, or click “Cancel” button to cancel.
Menu Name Description
LNB LO Frequency To configure the local oscillator frequency according to the right
satellite, its range is from 5150 to 11,300MHz.
Satellite Frequency To configure the satellite down link frequency according to the
right satellite, its range is from 1000 to 26,500MHz.
Symbol Rate To configure the symbol rate of QPSK signal, its range is from
1000 to 45,000KBaud.
PLS Gold Code
To configure the PLS gold code, its range is from 0 to 262,141.
Frequency Offset High To ensure the tuner locks the specific signal, its range is from
1000K to 5,000KHz.
Frequency Offset Low To ensure the tuner locks the specific signal, its range is from
-5,000K to -1,000KHz. The condition is “Freq Offset Low < Real IF
- Setting IF < Freq Offset High”.
LNB Voltage To select the correct LNB voltage output from the F-connector,
user can choose between Off, 13V and 18V.
LNB 22KHz To activate the LNB 22KHz control signal to the LNB, user can
select between On and Off.
DiSEqC To configure the DiSEqC control, user can select Port A, Port B,
Port C, Port D or DiSEqC OFF.

DXP-3800D
- 20 -
5.2.2.2 Configuration-CI
CI (1~8)
Set parameters for CI descrambling. Before you want to active this function, you
have to insert the right CI cards into the CI slots. When select the right Input Source,
the programs will be listed in the table, you can descramble the right programs.
Click “Apply” button to submit, or click “Cancel” button to cancel.
5.2.2.3 Configuration-Biss
Biss (1~8)
Set parameters of BISS Descryption. DXP-3800D supports BISS-1 and BISS-E
mode. Click “Apply” button to submit, or click “Cancel” button to cancel.
Table of contents
Other PBI Computer Hardware manuals