PUMP INSTRUCTIONS:
SPECIAL WARNINGS & CAUTIONS:
WARNINGS:
1. To reduce the risk of electric shock, connect only to a properly grounded, grounding type receptacle (GFCI).
2. Do not exceed the voltage shown on the pump.
3. Always disconnect the pump from the power source prior to beginning any maintenance or work on the pump or fountain.
4. Inspect the power cord for damage before installation and/or maintenance. Replace the entire pump if damage is found.
5. For pumps with a 3-prong, grounded type plug, do not remove the grounding pin from the plug on the power cord.
CAUTIONS:
1. The fountain shall not be installed within 10 feet (3.05m) of a pool or spa. When the pump is connected to a GFCI protected circuit, the fountain unit has
the option of being installed no less than 5 feet (1.52m) from a pool or spa.
2. Use only with portable, self contained fountains no larger than 5’ in any direction.
3. Use a proper power source as indicated on the pump label. Keep the cord away from high temperature and/or heat sources.
4. Do not lift the pump by its power cord.
5. Keep the fountain out of reach of children.
6. Do not let the pump run dry. Pump must be completely submerged for proper operation and cooling.
7. Do not pump heated liquids.
8. Operate in freshwater only. Avoid heavily chlorinated water and water with high PH levels.
PUMP ASSEMBLY INSTRUCTIONS:
1. Remove the pump from the package and untie the power cord.
2. Place the pump in the desired location in your pond or fountain ensuring that it is completely submerged in the water. If the pump is to be used in a pond,
raise the pump off of the pond floor to ensure that it is above any dirt that will collect as this will adversely affect the performance of the pump.
3. Adjust the flow rate (if applicable) to the maximum (+) position.
4. If there is a light included with the fountain, connect the low voltage power cord from the light to the pump / Transformer.
5. Connect the low voltage power cord from the pump to the transformer. Place the transformer in a clean, dry area.
6. Connect the power cord from the transformer to a properly grounded, grounding type receptacle (GFCI).
7. If necessary, readjust the flow rate to the desired level (remember to always disconnect from the power source before handling the pump).
CARE & MAINTENANCE:
1. Keep the water clean – clean water will prolong the useful life of your pump.
2. Use a pre-filter on your pump if available.
3. Regular cleaning of the pump will be necessary depending upon the environment in which it is operated. Clean the pump when it is visibly soiled or
when a noticeable drop in performance is detected. Failure to clean the pump will result in overheating of the pump and the voiding of the
warranty!
4. Before cleaning, always disconnect the pump from the power source.
5. Disassemble the pump by removing the inlet screen & the impeller housing. Remove the impeller/rotor assembly by gently pulling on the impeller blades.
Use a soft cloth or brush to clean the area inside of the pump where the impeller/rotor assembly was. Clean the inlet screen, impeller housing & impeller
in warm soapy water. Reassemble the pump and inspect for proper operation.
HINTS & TROUBLESHOOTING:
1. Ensure that the pump’s flow control switch is set to maximum (+) before operating. Once the flow is established, the pump can be adjusted downward to
the desired level.
2. If the pump operates, but there is no flow, check to ensure the pump is fully submerged.
3. If the pump operates, but there is no flow, check the supply tubing for kinks and correct.
4. If the pump operates, but there is no flow, and if the pump is submerged and there are no kinks in the supply tubing, lift the pump from the water. Remove
supply tubing at pump outlet and clean tubing inside and out if necessary. Reset pump in water (outlet side up) and once water begins to flow, re-attach
the supply tubing.
LIGHT BULB REPLACEMENT INSTRUCTIONS:
1. If the accent light bulb is burned out, unplug the transformer from the power source. Wait a few minutes until the light is fully cool.
2. Pull the glass tube that covers the light bulb, from the receptacle by firmly grasping and twisting the tube (See fig 6).
3. The bulb may now be pulled from its socket and replaced with a new bulb (See fig. 7).
IMPORTANT SAFETY INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
WARNING -Lighted lamp is HOT!
Unplug and allow the lamp to cool before handling the lamp.
Keep lamp away from materials that may burn.
Do not touch the bulb at any time. Use a soft cloth. Oil from skin may damage lamp.
Do not operate the lamp with a missing or damaged lamp covers.
Transformer is replaceable with model # OUTPUT12V. 12WATT. Bulb is replaceable with model #12v .5 WATT, JC SUBMERSIBLE
HALOGEN BULB. Pump is replaceable with model # HI-1000. Call Customer Service for replacement parts.
SAVE THESE INSTRUCTIONS!
Each Peaktop product may have variations in texture, finish and appearance from one unit to the next. This enhances the beauty of the product and makes
your Peaktop product uniquely individual. Some products and finishes are intentionally weathered or worn in appearance for aesthetic design.