ADDITIONAL INFORMATION
PELLA UNIT ID: SERVICE MADE SIMPLE
To help save you time if your product ever needs service or repair, all entry doors sold by Pella include a special
identification number. On your entry door, you’ll find the Pella Unit ID Number on the top hinge.
EIFS AND SYNTHETIC STUCCO
Pella® products should not be used in barrier wall systems that do not allow for proper management of moisture within the wall systems, such
as Exterior Insulated Finish Systems (EIFS) (also known as synthetic stucco) or similar systems. Except in the states of California, New Mexico,
Arizona, Nevada, Utah and Colorado, Pella makes no warranty of any kind on and assumes no responsibility for Pella windows and doors
installed in barrier wall systems. In the states listed above, the installation of Pella products in EIFS or similar barrier systems must be in
accordance with Pella’s instructions for that type of construction.
STORM DOOR USAGE RECOMMENDATION
Entry door systems from Pella are designed to be compatible with the installation of a Pella storm door.
• A ventilating Pella storm door is optimal for use with an entry door from Pella.
• The use of a storm door of any type in higher temperature climates is not recommended.
• The combination of a darker color and direct sun can affect the panel material of an entry door from Pella when a storm door is used.
• The use of the ventilating screen is recommended during the summer months when using a fullview storm door with an entry door
from Pella.
NFRC LABEL
What’s so special about the National Fenestration Rating Council (NFRC) label?
It represents one standard testing method from an independent source for all kinds and
brands of windows and doors. It replaces a system of individual manufacturers testing their
own products with many different testing standards. With this label, you can make direct
comparisons. Keep in mind, energy efficiency is just one of the many important qualities to look
for in windows and doors. The NFRC has one single purpose: to establish and improve upon
uniform energy-rating procedures for all brands of windows and doors.
This nonpartisan coalition of professionals includes home and commercial builders, product
designers and specifiers, manufacturers, consumer advocates, utility company energy specialists,
and government agencies.
Pella Corporation is a member of the NFRC and supports its work on behalf of homeowners
and the building industry. If you have any questions about the NFRC, feel free to write to NFRC,
6350 Ivy Lane, Suite 104, Greenbelt, MD 20770 — or call 301-589-1776, fax 301-589-3884 or
visit nfrc.org.
Architect Series®, Pella® and Encompass by Pella® Entry Door Owner’s Manual Additional Information
7.1
NOTE: For example purposes only.
NFRC ratings will vary by product.
Unit ID Number
Pella Corporation
Entry Door
In-Swing
Not Applicable
PEL – X – XXX
ENERGY PERFORMANCE RATINGS
U-Factor Solar Heat Gain Coefficient
0.14 5.68 0.005
ADDITIONAL PERFORMANCE RATINGS
Visible Transmittance
0.00 – –
Manufacturer stipulates that these ratings conform to applicable NFRC procedures for determining
whole product performance. NFRC ratings are determined for a fixed set of environmental conditions
and a specific product size. NFRC does not recommend any products and does not warrant
the suitability of any product for any specific use. For more information, call (641) 621-3114
or visit Pella’s web site at www.pella.com or visit NFRC’s web site at www.nfrc.org.
Wind Load
Design Pressure
(DP) (psf)
+ 40 / – 40
(Per ASTM E330)
ENERGY STAR® Qualified
In All 50 States
Air / Water
Performance
Air Leakage
0.30 CFM/Ft2
per ASTM E283
Water Performance
3.7 psf
per ASTM E547
WDMA DP40 (Design Pressure 40 psf)
ASTM E330
Structural Only
HALLMARK
WINDOW AND DOOR
MANUFACTURERS ASSOCIATION
www.wdma.com CERTIFIED
WDMA License Number: XXX-X-XXX
Manufacturer Stipulates Conformance to the applicable standards.
WDMA Hallmark Certification. Pella products labeled with the Window & Door Manufacturers
Association (WDMA) Hallmark Certification are tested in accordance with applicable WDMA performance
standards, which requires products be tested for air infiltration, water infiltration and structural performance.
Performance of Pella products will change over time depending upon the conditions of use. For details on
Hallmark Certification, go to www.wdma.com.
Meets or exceeds M.E.C., C.E.C., & I.E.C.C. Air Infiltration Requirements
Glazing type & thickness: Not Applicable3.0MMboth panes, designed per ASTM E1300
Window or Door Actual Size: 37.500" wide by 81.500" tall
6210066 – 4 – 1 – NFRC.CCTHERMAUM
Field_Name_6210066 – 4 – 1 – NFRC.ZZTHERMAUM
(Metric/SI)(U.S./I – P)
Does this door meet the criteria
for its glazing level? (Check only one box)
For: U-factor SHGC Yes
Opaque ≤ 0.21 Any X
¼ or ½ Lite ≤ 0.27 ≤ 0.30
¾ or Full Lite ≤ 0.32 ≤ 0.30
Remove this label after final inspection; SAVE for future reference