Pelsue FT-C70 User manual

Part #500714-001
Product Manual:
Model #FT-C70
Carbon Fiber Composite Fall Arrest Tower
T.A. Pelsue Company
2500 South Tejon Street
Englewood, Colorado, USA 80110
Tel. 800-525-8460 or 303-936-7432
Fax. 303-934-5581
Internet: www.pelsue.com
Email: [email protected]
ISO 9001 Certified

500714-001 - Product Manual - #FT-C70 Carbon Fiber Fall Arrest Tower - Revision 02 - 2015-03-06
Page 2

500714-001 - Product Manual - #FT-C70 Carbon Fiber Fall Arrest Tower - Revision 02 - 2015-03-06 Page 3
Since our inception in 1963 – the T.A. Pelsue Com-
pany has designed and manufactured high quality
equipment to improve the personnel efciency and
working conditions in various underground, con-
ned, and outdoor areas.
Founded by T. Allen Pelsue, the company has estab-
lished a continuing reputation for excellence in the
production of ne products for a broad spectrum of
industry throughout the world.
Now, in our second generation of family direction,
continued commitment to innovation and qual-
ity makes Pelsue a leading source of equipment
for many types of conned spaces. We specialize
in safety, retrieval, fall arrest, ventilation, cable
placing, splicing, and maintenance nationally and
abroad. With more than 70,000 square feet of facili-
ties available, Pelsue continues the dedication that
has made it pre-eminent in this eld.
ISO 9001 Certified

500714-001 - Product Manual - #FT-C70 Carbon Fiber Fall Arrest Tower - Revision 02 - 2015-03-06
Page 4
Table of Contents
Section Description Page #
1.0......................................General Information.................................. 5
1.1...........................Quality Policy
1.2...........................Pelsue Product Warranty
2.0......................................Introduction & Product Information........ 7
2.1...........................Serial Number
3.0......................................Conguration & Assembly........................ 8
3.1...........................Decal Locations
4.0...................................... Safety.......................................................... 10
4.1...........................Warning Statement
4.2...........................Safety Alert Symbol
4.3...........................General Safety Information
4.4...........................Operating Safety
4.5...........................Maintenance Safety
4.6...........................New Operator or Owner Safety
5.0......................................Product Operation.....................................13
5.1...........................Product Description & Capabilities
5.2...........................Product Installation & Set-Up
6.0......................................Maintenance & Inspection........................17
6.1.......................... Maintenance
6.2.......................... Inspection
6.3...........................Inspection Log
7.0......................................Storage...................................................... 22
8.0...................................... Contact Information.................................. 22

500714-001 - Product Manual - #FT-C70 Carbon Fiber Fall Arrest Tower - Revision 02 - 2015-03-06 Page 5
1.0 General Information
T.A. Pelsue Company
Quality Policy
OUR GOAL IS THE PURSUIT OF NEVER-ENDING IMPROVEMENT IN
PRODUCT QUALITY AND BUSINESS SYSTEMS.
METHODS TO BE EMPLOYED IN ATTAINING THIS GOAL WILL INCLUDE
NEW PRODUCT QUALITY PLANNING, EMPLOYEE TRAINING, AND
UTILIZATION OF EMPLOYEE INVOLVEMENT GROUPS TO SOLVE
PROBLEMS.
IN AN INCREASINGLY COMPETITIVE MARKETPLACE, ENSURING
CUSTOMER SATISFACTION IS ONE OF THE DIFFERENTIATORS THAT
SETS YOU APART FROM THE PACK AND YIELDS A COMPETITIVE
ADVANTAGE.
THEREFORE, WE WILL SUPPORT TOTAL CUSTOMER SATISFACTION
BY
IMPLEMENTING THE ISO 9001 QUALITY SYSTEM AND PROVIDING
THE NECESSARY ATMOSPHERE AND TRAINING TO NURTURE THIS
CONCEPT THROUGHOUT OUR ORGANIZATION.
WE WILL MAKE EVERY BUSINESS DECISION AS THOUGH THE
QUALITY OF
THE PART OR SERVICE PROVIDED WAS DESTINED FOR OUR OWN
OR OUR FAMILY’S USE. WE WILL ALWAYS THINK QUALITY FIRST.
EVERY T.A. PELSUE COMPANY EMPLOYEE IS EXPECTED TO COMMIT TO
THIS PHILOSOPHY IN THE PERFORMANCE OF HIS OR HER DAILY TASKS.
QUALITY FIRST!
T.A. PELSUE COMPANY SENIOR MANAGEMENT TEAM
1.1 Quality Policy

500714-001 - Product Manual - #FT-C70 Carbon Fiber Fall Arrest Tower - Revision 02 - 2015-03-06
Page 6
PELSUE FALL ARREST/ RETRIEVAL PRODUCT WARRANTY
• Pelsue products are designed and engineered to perform as stated in published specications. Qual-
ity materials and workmanship are used in the manufacture of this product. With regular maintenance
and proper care, Pelsue equipment provides many trouble free hours of operation.
• The T.A. Pelsue Company warrants to the buyer that material furnished will conform to specications
and will be free from defects in material and workmanship from the date of shipment to the original
buyer, for the period listed by product description at the bottom of this warranty statement.
• In the event of failure of any components of a Pelsue product within the warranty period, service must
be pre-approved by the T.A. Pelsue Company and service must be performed by the T.A. Pelsue
Company Parts and Service Department in Englewood Colorado, or at the option of T.A. Pelsue Com-
pany, service may be performed at any designated service center, which may include any authorized
service center for the component manufacture.
• Damage or failure due to misuse, mishandling, or unauthorized modications will not be covered by
this warranty. Unless otherwise agreed, the T.A. Pelsue Company shall repair or replace the defective
components within (30) calendar days of notice of failure. T.A. Pelsue Company’s obligation hereun-
der, shall be limited to the repair or replacement of the product or component as set forth above, and
shall not include any liability whatsoever for damages caused by such failure, including but not limited
to consequential or incidental damages owing from use or lack of use of product.
• Any replacement, repair, modication, installation or other service performed by the T.A. Pelsue Com-
pany shall be warranted by the remainder of the unexpired period of the warranty, or for a period of
(90) calendar days, whichever is longer.
• All materials or parts returned for credit or warranty shall be returned only with prior approval, and will
be subject to factory inspection before credit is allowed. Parts claimed defective will be replaced upon
request and will be invoiced as purchased, subject to credit when the parts claimed to be defective
have been received and examined by the factory.
• This warranty is expressly in lieu of all other warranties expressed or implied, including any warranties
of merchantability or warranties of tness for any particular use and all other obligations or liabilities
in connection with the sale of this equipment.
Product Description Warranty Coverage*
• Davits and Bases, Life Guard Systems, Fall Arrest Towers,................ 1 year
Hitch Mounts, Mounting Sleeves
• Winches................................................................................................ 1 year
• Winch Cable and Rope (not including standard wear and................... 3 months
tear or misuse or improper storage)
• Rope..................................................................................................... 3 months
• Pelsue Painted or Plated Surfaces....................................................... 1 year
*From date of shipment to original buyer.
T.A. Pelsue Company, 2500 South Tejon Street, Englewood, Colorado 80110, 800-525-8460
1.2 Pelsue Product Warranty
1.0 General Information (continued)

500714-001 - Product Manual - #FT-C70 Carbon Fiber Fall Arrest Tower - Revision 02 - 2015-03-06 Page 7
2.0 - Introduction & Product Information
MODEL:____________________________________________
Serial Number :______________________________________
______________________________________
Date of Manufacture (DOM):__________________________
__________________________
Congratulations on your choice of a Pelsue Model #FT-C70 Composite Fall Arrest Tower to compliment your complete
fall arrest system. This equipment has been designed and manufactured to exceed fall arrest requirements and regula-
tions in order to meet the needs of the discriminating operator tasked with the assurance of efcient and safe working
conditions for personnel working upon an elevated surface.
Safe, efcient and trouble-free operation and maintenance of the system requires that anyone who will be operating,
maintaining, or inspecting the equipment, read, understand and follow all of the operation, safety, maintenance, and
inspection instructions contained within this manual. This manual covers the Pelsue Model #FT-C70 Composite Fall
Arrest Tower. Use the Table of Contents as a guide to nd specic information.
Keep this manual handy for frequent reference and to pass on to new operators. Establish a regular training program
for experienced and new operators per this manual. Establish a regular maintenance and inspection program to keep
the equipment in top condition.
This product is a part of a complete Fall Arrest System.
The user must read, understand and follow the instruc-
tions contained in this manual for each component or
total system before using this equipment. Establish
an appropriate training, maintenance and inspection
program for your people and the equipment. Failure
to follow these instructions could result in serious
injury or death.
2.1 - Serial Number
Product Serial Number
Always give your dealer the serial number of your Pelsue Fall Arrest product when order-
ing parts or requesting service or other information.
Each component of the system (base & tower) will have a Serial Number Label attached.
Each serial number label is permanently embossed with a serial number. The serial number
label will appear as shown in
Figure 2a
at the right. One is located on the base assembly
(refer to
Figure 2b
), and another is located near the top of the tower assembly (refer to
Figure 2c). A space has been provided below for the recording of the serial number for
future reference.
Figure 2a:
Serial Number Decal
#FT-C70
Figure 2b:
Serial Number Label Location
SERIAL
NUMBER
LOCATION
Figure 2c:
Serial Number Label Location
(BASE)
(TOWER)
(BASE)
(TOWER)

500714-001 - Product Manual - #FT-C70 Carbon Fiber Fall Arrest Tower - Revision 02 - 2015-03-06
Page 8
Figure 3.0: #FT-C70
Diagram & Parts List
3.0 - Conguration & Assembly
Upon initial receipt of the #FT-C70 system inspect the packaging for any evidence that the product may have been
damaged in shipment. While unpacking the product, inspect all of the components for damage. If damage to any of
the components is discovered, DO NOT USE THE PRODUCT! Alert the shipping carrier immediately of the damage
to the shipment.
Item Part No. Description Qty.
3A 500204-001 Ring - Tri Anchor 1
3B 500196-001 Collar - Anchor Ring Retainer 1
3C 121569-001 Screw - Socket Head Cap 4
3D 118283-002 Washer - Flat 4
4A 500426-WT1 Screw Peg - T-Bar 2
4B 500572-001 Pin & Lanyard, 3/4” x 6” 1
4C 500408-001 Pin & Lanyard, 1/2” x 4-1/2” 1
The #FT-C70 is normally shipped within two separate boxes.
One box will contain the Base Assembly (#500019-001) and the
other box will contain the tower assembly (#500573-001).
Ensure that all components of the system are present upon
unpacking of the system. A simple assembly process is required
in order to mount the tower assembly to the base assembly;
1. Insert the tower into the base assembly.
3. Align the holes on the on the tower with the holes on the base
assembly by rotating the tower section by hand. Then insert
the 1/2” Pin (#2) to secure the tower to the base.
**Refer to parts list above if replacement parts are required.
Replacement parts can be ordered from the T.A. Pelsue Com-
pany at 800-525-8460.

500714-001 - Product Manual - #FT-C70 Carbon Fiber Fall Arrest Tower - Revision 02 - 2015-03-06 Page 9
Figure 3.1: #FT-C70
Decal Locations
1
2
3
4
5
1) 500665-001
2) 500305-001
3) 500612-001
4) 500230-001
5) 103299-001
6) 500304-001
6
3.0 - Conguration & Assembly (continued)
3.1 - Decal Locations

500714-001 - Product Manual - #FT-C70 Carbon Fiber Fall Arrest Tower - Revision 02 - 2015-03-06
Page 10
The following section will address the safety precautions which must be adhered to when working with Pelsue Elevated
Fall Arrest Safety equipment such as the #FT-C70 Composite Fall Arrest Tower. Any user must familiarize themselves
with the information in this section before utilizing the equipment.
SIGNAL WORDS:
Note the use of the signal words DANGER, WARNING and CAUTION with the safety messages. The appropriate signal
word for each message has been selected using the following guidelines:
DANGER- Indicates an imminently hazardous situation that, if not avoided, will result in death or serious injury. This
signal word is to be limited to the most extreme situations or for hidden or unseen hazards.
WARNING- Indicates a potentially hazardous situation that, if not avoided, could result in death or serious injury and
includes obvious and hidden hazards. It may also be used to alert against unsafe practices.
CAUTION- Indicates a potentially hazardous situation that, if not avoided, may result in minor or moderate injury. It
may also be used to alert against unsafe practices.
You are responsible for the safe operation, maintenance and inspection of your Pelsue #FT-C70 Composite Fall Arrest
Tower. You must ensure that anyone who will operate, maintain, inspect or work around the equipment be familiar with
the operating and maintenance procedures and related safety information contained in this manual. This manual will
take you step-by-step through the workings and capabilities of the #FT-C70 Composite Fall Arrest Tower and alert you
to all good safety and operating practices while using the system.
Remember, you are the key to safety. Good safety practices not only protect you but also the people around you. Make
these practices a working part of your safety program. Be certain that everyone operating this equipment is familiar with
the procedures recommended and follows safety precautions. Remember, most accidents can be prevented. Do not risk
injury or death by ignoring good safety practices.
• System owners must give operating instructions to operators or employees before allowing them to use the
equipment and at least annually thereafter.
• The most important safety device on this equipment is a safe operator. It is the operator’s responsibility to read
and understand all safety and operating instructions in the manual and to follow these. Most accidents can be
avoided.
• A person must understand the operation of this equipment and be trained in it’s usage before operating the
equipment. An untrained operator exposes himself and others to possible serious injury or death.
• Do not modify the equipment in any way. Unauthorized modication may impair the function and/or safety and
could affect the life of the equipment.
• Think SAFETY! Work SAFELY!
4.0 - Safety
4.1 - Warning Statement
WARNING!
Products manufactured or sold by the T.A. Pelsue Company are
intended for use by professionals trained and experienced in the
use, inspection and maintenance of these products.
Paraprofessional users such as volunteer rescue workers and
sportsmen involved in risk sports such as climbing and caving
will be held to the same standard of experience and training as
professionals.
Technical rescue, repelling, climbing and the training involved are
hazardous activities. Each situation has its own unique condi-
tions and must be evaluated. Effective risk management comes
from experience, proper training and good personal judgement.
7!2.).'
Failure to read and heed all labels and instructions may
result in injury or death. Inspect all components before
and after each use, and remove from service if any
damage or defect is found. Keep product free from dirt
and moisture. Do not leave a suspended load
unattended. Do not exceed maximum rated loads.

500714-001 - Product Manual - #FT-C70 Carbon Fiber Fall Arrest Tower - Revision 02 - 2015-03-06 Page 11
SAFETY ALERT SYMBOL
This Safety Alert symbol means ATTENTION! BECOME ALERT! YOUR
SAFETY IS INVOLVED!
The Safety Alert symbol identies important safety messages on your Pelsue
Retrieval Product and in the manual. When you see this symbol, be alert to
the possibility of personal injury or death. Follow the instruction in the safety
message.
Why is this symbol important to you?
3 BIG Reasons: Accidents Disable and Kill.
Accidents Cost You Money.
Accidents Can Be Avoided.
1. Read, understand, and follow the Product Manual and all safety signs before using, maintaining or inspecting the
equipment.
2. Refer to and follow applicable standards and regulations. Comply with requirements of local regulations for your
applications.
3. Establish an equipment-use training program for inexperienced employees. Only trained, competent persons shall
use the equipment. An untrained operator is not qualied to operate the system.
4. Have a rst-aid kit available for use should the need arise and know how to use it.
5. Provide a re extinguisher for use in case of an accident. Store in a highly visible place.
6. Install and properly secure all guards and shields before operating.
7. Wear appropriate protective gear. This list includes but is not limited to:
• A hard hat
• Protective shoes with slip resistant soles
• Heavy gloves
• Protective clothing
• Face Protection
8. Review and follow the Pre-Operation Checklist before using a component in the system or the system itself.
9. Establish a regular maintenance and inspection program with your equipment and maintain detailed records.
10. Review safety related items and operating instructions with all personnel on a regular basis.
1. Read, understand and follow the User Manual and signs on the product before using, maintaining or inspecting the equip-
ment.
2. Train all operators before allowing them to use the product. An untrained operator exposes themselves, bystanders
and workers to possible serious injury or death.
3. Visually inspect the product and all auxiliary components and equipment before using. Correct any problems before
using the equipment.
4. Securely anchor the product before using.
5. Use only certied anchor and connector components in your system.
6. Use only an approved full body harness for the workers.
4.0 - Safety (continued)
4.2 - Safety Alert Symbol
4.4 - Operating Safety
4.3 - General Safety Information

500714-001 - Product Manual - #FT-C70 Carbon Fiber Fall Arrest Tower - Revision 02 - 2015-03-06
Page 12
1. Read, understand and follow the User Manual and signs on the product before using, maintaining or inspecting the equip-
ment.
2. ANSI and OSHA require a regular inspection program for all elevated fall arrest tower equipment and to maintain
documented results of these inspections. Follow the inspection procedure contained in this manual and use the
inspection form to document the results (see section 6.0).
3. Keep instructional and safety signs clean and legible at all times. Clean or replace as required.
4. Remove the equipment from service if a problem is found during the inspection. Return to an authorized repair depot
or the factory for service.
The Pelsue Model #FT-C70 Composite Fall Arrest Tower is designed to provide three elevated fall arrest system anchor
points. Every new operator must read, understand and follow the instructions in the manual. No one should be allowed
to use the equipment without training. The training should be reviewed with experienced operators on a regular basis.
At regular intervals, perform a detailed inspection of the equipment and document the results. Remove from service if
deciencies are found. Alterations or misuse of this equipment or failure to follow instructions may result in serious injury
or death.
It is the responsibility of the owner’s organization or operator to read this manual and to train all other operators before
they start working with the equipment. Follow all safety instructions exactly. Safety is everyone’s business. By following
recommended procedures, a safe working environment is provided for the operator, bystanders and the area around
the work site. Untrained operators are not qualied to operate the equipment.
Many features incorporated into this equipment are the result of suggestions made by customers like you. Read this
manual carefully to learn how to operate the equipment safely and how to set it to perform as intended. By following the
operating instructions in conjunction with a good maintenance program, your product will provide many years of trouble
free service.
7. Always work in teams. One person is to work in the elevated space (entrant) and the other is to attend to the entrant
(attendant). Pelsue recommends an additional attendant/rescuer for stand-by in case of an emergency.
8. Do not exceed the capacity of the system at any time (see section 5.1).
9. Establish a regular training program for new and experienced workers.
10. Establish a detailed inspection program for your equipment and document the ndings. Return the equipment to
the manufacturer for repair if any problems are found.
11. Plan your work program before starting. Have the required people, equipment and procedures available to do the
job.
12. Do not use the equipment around physical or environmental hazards. This list includes but is not limited to:
• Corrosion that may affect the structural integrity of the lifeline or other components.
• Chemicals which can degrade components in a manner which can not be visually identied.
• Toxic gases: Rescuers or workers can be killed in toxic environments.
• Heat or elevated temperatures.
• Moving machinery: Workers or auxiliary equipment can be contacted by or pulled into moving components.
• Sharp edges: Workers or the rescue equipment can be injured by or damaged by sharp edges or components.
• Electrical hazards: Stay away from power lines or components carrying electrical power.
• Overload: Do not overload the system at any time during operation (see section 5.1).
• Follow elevated space regulations and standards.
4.0 - Safety (continued)
4.5 - Maintenance Safety
4.6 - New Operator or Owner Safety

500714-001 - Product Manual - #FT-C70 Carbon Fiber Fall Arrest Tower - Revision 02 - 2015-03-06 Page 13
The Pelsue #FT-C70 Composite Fall Arrest Tower is constructed of a composite carbon ber tube and base struc-
ture composed of an aluminum & magnesium alloy, and also incorporates several alloy steel and engineered plas-
tic components. The Model #FT-C70 possesses a composite upper section (#500573-001) which can be inserted
into its standard base (#500019-001) to create a 70” high anchor point. The #FT-C70 can also be congured in a
“Rescue Mode” in the event a person or persons require rescue capabilities. In this conguration the tower can be
“heeled” over up to 23 degrees via the adjusting screw pegs in the base. This practice allows greater clearance away
from the side of the work platform for raising or lowering a fallen worker. The #FT-C70 tower can not be used for the
anchorage of fall arrest systems while congured in “Rescue Mode.” All specications, instructions, and procedures
provided within this manual or upon Pelsue Specication Documents are based upon and only valid for usage with a
Pelsue FT series Fall Arrest Tower approved accessories. The T.A. Pelsue Company can not verify equipment safety
and/or compliance when utilized with anything other than Pelsue approved FT-C70 Series accessories.
Composite Fall Arrest Tower, Model #FT-C70
General Specications
• Safe Working Radius @ Tower Base - 5’10”
• Structure Weight - Tower - 10.5 lbs.
- Base Assembly - 28.5 lbs.
• Tower Height - 5’10”
5.0 - Product Operation
The following section will address the capabilities and the general operation of the Pelsue #FT-C70 Composite Fall Arrest
Tower. The instructions contained within this section should be adhered to each and every time the product is used. Any
person tasked with installing or operating this piece of equipment should be familiar with these procedures.
The load rating(s) reported within this docu-
ment may supersede or be superseded by
the rating of an accessory or complemen-
tary component. The capabilities of a com-
plete Personal Fall Arrest System (PFAS)
are limited by the “weakest” component
utilized within that complete system!
5.1 - Product Description & Capabilities
Load Capacity
• Up to three users with a maximum
weight of 310 lb/person with a safe
working radius of 5’10” about the
Tower Base
• Refer to loading diagrams for proof
loads.
Materials & Construction
Tower Assembly: Carbon Fiber,
Machined 6000 Series Alumi-
num, High-Tensile Nylon Web-
bing & High Strength Steel
Base Assembly: Aluminum &
Magnesium Alloy, Alloy Steel &
UHMW PE Components
Hardware: Plated Steel
Features:
• Installs on elevated surfaces where access is required via a
variety of available base option.
• Provides an elevated, swiveling fall arrest anchor point for up
to three persons
• Offers a “rescue mode” in the event that a person were to fall
and require rescue

500714-001 - Product Manual - #FT-C70 Carbon Fiber Fall Arrest Tower - Revision 02 - 2015-03-06
Page 14
Prior to Operation, the #FT-C70 Composite Fall Arrest Tower should be
congured and prepared according to the following guidelines.
1. Pre-Operation Inspection:
It is necessary to perform a visual inspection prior to each time using the
product. If deciencies are found, remove the product from service and con-
tact the T.A. Pelsue regarding repair. The following checklist coupled with
Figure #5.2a should be used as a guide to determine whether the equipment
is in good operating condition prior to usage. Equipment that is not in good
condition can endanger the safety of the entrant and attendant during use.
The Pre-Operation Visual Inspection is not limited to, but must include the
following items;
a. Check that the product has no structural defects, such as dents, bends,
Additional Requirements & Notes
• The #FT-C70 Series Fall Arrest Tower must be installed on a level surface and made vertical prior to use.
• In order to ensure compliance, it is the user’s responsibility to ensure that the structure to which the #FT-C70 is
attached is capable of withstanding all of the loads imparted to it by the proof-loaded #FT-C70 Fall Arrest Tower.
• An approved Pelsue base system is required for operation & installation (i.e. The FB-SW1 Fall Arrest Base Plate)
Figure #5.2a: #FT-C70 Series
Pre-Operation Inspection Points
Leveling
Screws
Base Plate
Figure #5.1a:
Loading Diagram
2000 LB.
[907 kg]
STATIC
PROOF
LOAD
45º
Figure #5.1c:
Loading Diagram
620 LB. [281 KG]
Static Pre-Load
45º
3100 LB.
[1406 kg]
STATIC
PROOF
LOAD
23º Max
Rescue Mode
5400 LB. [2449 KG]
DYNAMIC PROOF
LOAD
Figure #5.1b:
Rescue Mode - Loading Diagram
Pins
Tri-Ring
Anchor
5.0 - Product Operation (continued)
5.2 - Product Installation & Set-Up
! CAUTION ! - The user must ensure that the station to which the
tower base is installed is capable of withstanding the weight of the
system combined with the system proof loads in order to retain the
stated compliance of the entire system.
! CAUTION ! - The user must ensure that the tower system is
properly installed & completely vertical in order to retain the stated
compliance and stability of the entire system.
! CAUTION ! - The user must ensure that the pin securing the tower to the base assem-
bly is fastened as well as the pin securing the base assembly to the base plate in order to
retain the stated compliance of the entire system.

500714-001 - Product Manual - #FT-C70 Carbon Fiber Fall Arrest Tower - Revision 02 - 2015-03-06 Page 15
Figure #5.2d: #FT-C70
Completely Installed
!WARNING! - The user must ensure that
all pins & fasteners are in their “locked” posi-
tions, that the tower is completely vertical,
and that the base system (plate) is correctly
installed in order to prevent death or injury to
the user or damage to the product!
cracks, or fractures.
b. Ensure that all product rating & warning labels are clear and legible.
c. Ensure that the Tri-Ring Anchor Point rotates smoothly and has not been damaged.
d. All hardware (Pins, Leveling Screws) have not been damaged and are in working condition.
2. Setup of #FT-C70 Composite Fall Arrest Tower:
Choose a location where installation will provide suitable proximity to the work area yet minimize obstructions during
use and in the event a rescue is necessary. Once a location is chosen;
Leveling
Pegs
Figure #5.2c: #FT-C70
Tower Vertical and Secured to Structure
Figure #5.2b: #FT-C70
Base Pin
5.0 - Product Operation (continued)
a. Align the holes of the tower with the holes of the base plate and
pin to secure the two (Refer to Fig. #5.2b).
b. After the tower and base plate have been connected, securely
install the tower base to the structure.
c. The tower must adjusted to vertical using the leveling screws (Refer
to Fig. #5.2c).
d. Once the tower is completely vertical, a Lanyard or an SRL device
can now be attached to the Anchor Point.
e. Disassembly is reverse of assembly steps.

500714-001 - Product Manual - #FT-C70 Carbon Fiber Fall Arrest Tower - Revision 02 - 2015-03-06
Page 16
Figure #5.2f: #FT-C70
Adjusting Leveling Pegs
3. #FT-C70 Composite Fall Arrest Tower in RESCUE MODE:
In the event of a fall, the Model #FT-C70 can be used as a rescue device utilizing the following directions;
a. In the case that a person or persons have fallen, allow them to come to a rest before performing a rescue
(Fig. #5.2e).
b. At the base of the tower, the leveling screws can be adjusted in whichever direction is more suitable for rescue
(Fig. #5.2f).
c. Unscrew the peg on the side of the desired direction to lower the tower while screwing in the opposite peg
(Fig. #5.2f).
d. The tower can be offset a maximum of 23 degrees from the vertical position (Fig. #5.2g).
e. If not employing a 2 or 3 way SRL System, the #FT-C70 is designed to accept a Pelsue Pole Hoist for rescue
capability.
Figure #5.2e: #FT-C70
Completely Vertical
Person or Persons
Figure #5.2g: #FT-C70
Completely Tilted
23º Max
Leveling
Pegs
5.0 - Product Operation (continued)
!WARNING! - The #FT-C70
tower must not be used as
an anchorage for a fall arrest
device while deployed within its
“Rescue Mode” conguration

500714-001 - Product Manual - #FT-C70 Carbon Fiber Fall Arrest Tower - Revision 02 - 2015-03-06 Page 17
MAINTENANCE & INSPECTION
6.0 - Maintenance & Inspection
1. Read, understand and follow the Product Manual and signs
on the product before using, maintaining or inspecting the
equipment.
2. ANSI and OSHA require a regular inspection program for
all elevated fall arrest equipment and to maintain docu-
mented results of these inspections. Follow the inspection
procedure contained in this manual and use the inspection
form to document the results.
3. Keep instructional and safety signs clean and legible at
all times. Clean or replace as required.
4. Remove the equipment from service if a problem is found
during the inspection. Return to an authorized repair depot
or the factory for service.
For the most part, the Model #FT-C70 is intended to be a maintenance-free piece of equipment, however several steps
can be taken to keep the system in top-notch working order and also extend the working life of the product.
Before Each Use:
1. Visual Inspection: Perform a complete visual inspection. Refer to section 6.2 for guidelines and take any
maintenance steps that are necessary.
Annually:
1. Clean Product: Use a damp cloth and mild soap to clean the structure and labels of dirt and residue. Be sure
the labels are legible (replacements are available from Pelsue)
2. Oil or grease the threaded screw pegs to ensure smooth operation.
3. Complete Inspection: Perform a thorough inspection, paying attention to the bullet points provided within
section 6.2. Record results and keep documentation. A log has been provided in section 6.3 specically for
the recording of the dates & results of annual system inspections.
Periodic Factory Service Inspection: It is recommended that the product be serviced by a factory authorized
service center or the manufacturer after a period of three years. Extreme working conditions may indicate
the necessity to increase the frequency. Factory servicing shall include but not be limited to an intensive
inspection and cleaning of all internal and external components. Failure to provide proper service may shorten
product life and could endanger performance or function.
When completing an inspection of the Model #FT-C70 Composite Fall Arrest Tower, the following specic items should
be checked;
1. Labels:
Check that all the labels are clean and legible (Refer to Section 3.1). Clean the labels if any are dirty using mild
soap and a damp cloth. Replace if any are illegible. Decals & labels provide valuable warning and caution infor-
mation applicable to product usage and limitations, and should be visible and present at all times.
2. Fasteners:
Check that all screws and other fasteners are present and secure. Note that some fasteners may not be tightened
to their maximum allowable torque. This is done in order to allow for pivoting and/or folding motions in certain
components. Over-tightening of fasteners can interfere with the operation of the device and can damage the
structure.
All fasteners on the Model #FT-C70 system are of a self-locking design. Bolt threads should extend all the way
though their locking nuts. If any fasteners have appeared to “back-out” or loosen the product should be removed
6.1 - Maintenance
6.2 - Inspection

500714-001 - Product Manual - #FT-C70 Carbon Fiber Fall Arrest Tower - Revision 02 - 2015-03-06
Page 18
from service until the problem can be identied and corrected.
3. Overhead Anchor Points:
Ensure that the Tri-Ring Anchor is securely fastened and can rotate freely. The aluminum head piece and retaining
ring should be securely fastened and exhibit “near zero” free play. A non-rotating Tri-Ring Anchor may be indicative
of other damage, remove the product from service immediately if the Anchor Ring binds or does not rotate.
4. Structure:
The entire product structure should be checked for cracks, dents, bends or breaks. If dents, cracks, or any other
structural damage is witnessed, the unit must be removed from service and returned to the factory for repair.
• Pay special attention to areas of material transition (i.e. aluminum to composite): look for cracks or separa-
tion at such transitions. Be aware that powder coating can age and crack, this normal paint cracking can be
confused with structural cracking. If there is any uncertainty with regards to cracks, contact the Pelsue service
department for assistance and/or recommendations
5. Leveling Mounts (screws):
Ensure that the Leveling Screws are in working condition. Oil or grease the threaded rod if required. Also, visually
inspect to verify that the threading on the leveling screws has not been damaged in any way.
6.0 - Maintenance & Inspection (continued)

500714-001 - Product Manual - #FT-C70 Carbon Fiber Fall Arrest Tower - Revision 02 - 2015-03-06 Page 19
Date Labels Pins & Fasteners Overhead Anchor
Points Overall Structure Leveling Mounts Notes
Place a check (¥)in the box if item is acceptable, place an x (X) in the box if item requires maintenance or repair
Model Number :
Serial Number :
Date Purchased :
#FT-C70
Inspector (print & sign) :
Overhead Anchor Points
Inspector (print & sign) :
Inspector (print & sign) :
Inspector (print & sign) :
Inspector (print & sign) :
Inspector (print & sign) :
Inspector (print & sign) :
6.0 - Maintenance & Inspection (continued)
6.3 - Inspection Log

500714-001 - Product Manual - #FT-C70 Carbon Fiber Fall Arrest Tower - Revision 02 - 2015-03-06
Page 20
Date Labels Pins & Fasteners Overhead Anchor
Points Overall Structure Leveling Mounts Notes
Inspector (print & sign) :
Inspector (print & sign) :
Inspector (print & sign) :
Inspector (print & sign) :
Inspector (print & sign) :
Inspector (print & sign) :
Inspector (print & sign) :
Inspector (print & sign) :
Inspector (print & sign) :
6.0 - Maintenance & Inspection (continued)