Pendiq Pendiq 2.0 User manual

1
User Manual
DIQ-IFU-02 (Rev.0 2017.03.30)
0068

2
Introducon
SafetyGuidelines
Contentsproductbox
Components
Operaon buons
Gengstartedwithyourpendiq2.0
Step 1 – Language
Step 2 – Date/Time
Step 3 – Cartridge sengs/Replacing a cartridge
Injecon
Aaching a pen needle
Prime
Dose Seng
Injecng your dose
Aer the injecon
Memoryfuncon
Sengs
Bluetooth
Turn Bluetooth ON/OFF
Bluetooth PIN
Speaker
Contents
4
5
13
14
15
17
18
19
22
28
29
30
31
33
35
36
38
39
41
45
47
page

3
49
51
54
58
62
65
67
68
68
71
73
74
76
77
79
82
82
86
90
91
94
95
103
104
Language
Date/Time
TimeBlock
Add a TimeBlock
Change a TimeBlock
Delete a TimeBlock
Dose limit
Dose limit for a day (1 Day)
Dose limit for injecons (1 Time)
Default seng
Version
Baery
Cleaningundmaintenance
DiabetesManagementApp
Glossary
Specicaons
Display symbols
Warning & Errors
Icon descripon
Technical informaon
Factory default sengs
Electro-Magnec Compability
Product warranty
GeneralInformaon

4
Introducon
The digital insulin pen pendiq 2.0 is designed to
deliver insulin for the insulin-required diabetes
mellitus. With this pen you can adjust every dose
up to increments as small as 0.1 U (0.001ml) and
with the memory funcon you can review your
injecon history with the date, me and amount
of insulin delivered. The Bluetooth funcon lets
you transfer data from your pendiq 2.0 to a
Diabetes Management Soluon.
This manual gives you instrucons on how to
use and maintain your pendiq 2.0.
Please read this manual thoroughly and
familiarize yourself with the informaon
beforeusingthepen.Weadviseyoutokeep
thismanualforyourreference.

5
SafetyGuidelinespendiq2.0
Consult a healthcare professional
regarding your condion before using the
pendiq 2.0, and carefully read the safety
guidelines provided in this user manual.
Consult your healthcare professional, if
you encounter abnormal blood glucose
levels.
Do not share this pen with other people
to prevent infecon.
Inject only into the body areas suggested
by the ocial naonal endocrinologist
associaon, your healthcare professional
or your physician.
You should change the injecon area
for each injecon. Aer discussing the
injecon areas with your healthcare
professional, follow the instrucons given
at all mes.

6
Before using the pendiq 2.0 for the rst
me, make sure to set the correct date and
me, and to change the Bluetooth PIN
number.
Before every injecon, make sure that the
body of the pendiq 2.0 and the cartridge
holder are rmly screwed together.
Always remove possible air bubbles before
each injecon.
The pendiq 2.0 is a technical, medical
device. Use the pendiq 2.0 properly.
Always check the remaining insulin amount
before each injecon to ensure that there
are enough units le for your dose.
Always remove the pen needle before
changing the cartridge.
Do not modify or disassemble the pendiq
2.0. Do not use the pendiq 2.0 if any
part of your pendiq 2.0 looks broken or
damaged. Contact your local supplier or
your healthcare professional.
Do not forcefully remove the USB cover.

7
The manufacturer shall not be held liable
for any problems, damages or malfuncons
arising from a Force Majeure or other
events beyond the control of the
manufacturer.
Do not remove the cartridge holder
before the plunger is fully rewound when
changing a cartridge.
Do not throw your pen on purpose as
shocks and impacts may damage the pen.
The pen is not designed for the blind or
visually impaired without a trained assistant.
Make sure the insulin cartridge in the seng
matches the insulin cartridge manufacturer
(Novo, Lilly, Sano…) you are using.
If they do not match the pen cannot
recognize the exact residual amount of
insulin in the cartridge and the amount of
units displayed may then dier from the real
residual amount.
This can result in the injecon of an incorrect
dose.

8
Do not expose the pendiq 2.0 to high
temperature and/or humidity. The
pendiq 2.0 is not water-proof and holds
no protecon against the ingress of water
or moisture. When exposed to water or
moisture the pen may suer damages
and not funcon properly.
Do not store the pendiq 2.0 in a
refrigerator.
Do not expose the pen to heat or direct
sun light.
Do not expose the pendiq 2.0 to
ammable and/or combusble mixtures.
Do not expose the pendiq 2.0 to any
electromagnec waves and/or frequency
(CT, MRI, X-ray, etc.). The pen may suer
damages when exposed to electromagnec
waves.
Always make sure that the baery is fully
charged. It is recommended to fully charge
the baery as oen as possible to extend
the duraon of baery life.

9
Only one type of insulin cartridge (Basal/
Bolus) can be used with one pendiq 2.0. Do
not use dierent insulin cartridges (Basal/
Bolus) for one device.
Compability: The pendiq 2.0 pen is
only suitable for the use of 3ml insulin
cartridges (300 Units, U 100 insulin)
of the manufacturers Novo Nordisk®,
Lilly®, Sano-Avens® and Berlin-
Chemie®. Do not use insulin cartridges
from manufacturers other than the
manufacturers stated above.
Do not use NPH or premix insulin with the
pendiq 2.0.
Do not use a non-sterilized or damaged pen
needle. Healthcare professionals strongly
recommend not reusing a pen needle.
Using a new needle for each injecon will
minimize the risk of infecons and a pen
needle blockage.

10
Do not keep the needle aached to the
pen aer the injecon. Always safely
withdraw and dispose the used needle.
Always follow general safety measures
for the removal and disposal of needles in
order to minimize the risk of unintended
needle penetraon and transmission of
infecous diseases. Otherwise, it may
cause incorrect insulin delivery, leakage of
insulin and unintended needle injury, etc.
Please follow the instrucons and the safety
guidelines of the pen needle manufacturer,
as disregard may cause infecon and/or
damage in the injecon area.
The manufacturer is not responsible for any
problems caused by the malfuncon of the
Bluetooth connecon between the pendiq
2.0 and a smartphone app.
We recommend not using the device if you
are an individual with hypersensive
reacons to insulin.

11
We recommend not using the device if you
suer from mental and/or developmental
disabilies, or have impaired dexterity.
The motor funcon is limited while the pen
is charging. It is not possible to make an in-
jecon while the baery is charging.
The manufacturer is not responsible for the
safety, dosage accuracy and funconality as
well as any damages caused by the usage of
insulin cartridges that are not adequate for
the pendiq 2.0.
We recommend not using the device if
you are an individual who has not been
prescribed by a doctor to inject insulin.
All users under the age of 14 should be
under supervision of a trained parent or
a healthcare professional when injecng.
We recommend not using the device if
you are an individual with no diabetes.

12
Please carry an emergency kit
with you at all mes, containing
the following components in
case of emergencies.
Make sure to inform your
family, friends and colleagues
where to nd the kit.
Emergencykitshouldinclude:
Blood glucose meter and strips
Blood or urine ketone meter and strips
Spare insulin cartridge prescribed by doctor
Insulin injecon syringe
Alcohol swab
Emergency food for hypoglycemia
Diabec paent identy card with all necessary info
Micro USB cable for charging the baery of the pendiq 2.0
EmergencyKit(Recommended)

13
Digital insulin pen pendiq 2.0
User Manual English
User Manual German
USB cable
USB adapter
Cartridge holder Novo Nordisk
Warranty card
Contentsproductbox
Check if all the following components
are included in the pendiq 2.0 box:

14
A
B
C
C1
D
E
F
G
Components
Pen cap
Product body (D~G)
Cartridge holder
Cartridge holder (for Novo Nordisk cartridge)
Operaon buons
OLED screen
Micro USB port
Plunger

15
Operaon buons
buonisused
- to increase a number
- to select a seng
- to go forward in the menu
buonisused
- to decrease a number
- to select a seng
- to go back in the menu
buonisused
- to turn on the pen
- to conrm an operaon or seng
- to inject a dose
buonisused
- to enter the menu
- to return to previous screen
- to cancel an operaon or seng

16
Please visit our homepage www.pendiq.com/downloads
to see a menu tree of the pendiq 2.0.

17
Gengstartedwithyourpendiq2.0
When you use your pendiq 2.0 for the rst
me, follow the steps below to get started.
Before you use your pendiq 2.0 for the rst
me, you need to charge the baery. Read
the chapter „Baery“ for more informaon.
The pendiq 2.0 has no OFF buon.
The screen turns itself o aer 60 seconds
when no buon is pressed. When going
through the menu, you can always return to
the home screen by pressing .
The device will come with factory default
sengs. Before you can use your pendiq 2.0
for injecon, you need to complete the inial
setup. Follow the next steps to get started.

18
Step 1 – Language
Press to start.
You will see the word,
“Deutsch“ ashing on
the screen.
Press or to select
the language you wish
to use. You can choose
between German (1)
and English (2).
Press for 3 seconds
to turn on the display
for the rst me.
The inial language
seng screen appears.
The factory language is
German.
Select language
and press .
“Done” will appear
on the display.
The inial setup
will automacally
connue to “Date/
Time” seng.

19
Step 2 – Date/Time
Injecons in the
injecon history
are displayed
with date and
me.
Therefore, it is
important to set
a correct Date/
Time before
making the rst
injecon.
Press to start
with seng the
year. The year starts
ashing.
Press or to
adjust the year and
conrm with .
Press or to
select the month
and conrm with
.
Aer you have
completed the inial
language seng,
the setup will connue
with the inial
“Date/Time” seng.

20
Press or to
set the hour and
conrm with .
Press or to
set the minute.
Press and hold
or to increase
number by 10.
Press or to
set the day and
conrm with .
Other manuals for Pendiq 2.0
1
This manual suits for next models
5
Table of contents
Popular Health Care Product manuals by other brands

ResMed
ResMed stellar series Quick setup guide

ARJO HUNTLEIGH
ARJO HUNTLEIGH Sara Stedy Instructions for use

Dionex
Dionex UltiMate 3000 LCi Quick installation guide

Drive Medical
Drive Medical Therma Moist Heating Pad user manual

Mangar
Mangar Camel User instructions

ResMed
ResMed S8 Compact System user manual