Congratulations on the purchase of your Perrin & Rowe kitchen tap!
The Traditional Kitchen Collection
Installation & User Guide
ATHENIAN - E.4370, E.4371, E.4375, E.4376
1
3/8"
Hole
Diameter
Base Seal
Nut
Box Spanner
Clamp Plate
Securing Stud
35mm
Hole
Diameter
Base Seal
Nut
Box Spanner
Clamp Plate
Securing Stud
Correctly installed and with sensible care, it will give many years of trouble free service.
Before you proceed... We recommend you engage the services of a registered plumber to
install this product.
Read the instructions and diagrams in this leaflet carefully.
Preparation
1) Flush the plumbing system before installing the tap.
This is to avoid plumbing residues clogging or possibly damaging the ceramic valves.
This is especially important where extensive plumbing work has been carried out.
For ease of possible future servicing, we recommend the fitting of conveniently placed
isolating valves.
Check List
l
Temperature of the hot water supply does not exceed 85 C.
l
Recommended minimum water supply pressure - 1 bar.
l
Rinse product ideal performance obtained with equal hot and cold pressures.
l
Recommended maximum water supply pressure - 5 bar.
Athenian Sidevalve and Centrebody Assembly - Refer to Figure 1.
2) The Centrebody requires a 35mm diameter hole through the surface they are to be
installed on. Maximum counter-top thickness 45mm.
3) Insert the flexible connections through the hole ensuring that the seal is in place
between the centrebody and mounting surface. Connect these to the relevant supply
lines.
4) From the underside of the counter-top, place the clamp plate on securing stud and
using the box spanner supplied, put fixing nut in spanner and tighten until
centrebody is held firmly in position. See Figure 1.
5) For sheet metal sinks, use sink support provided.
6) The side valve assemblies require a 30mm diameter hole through the counter-top
surface. Hot supply should be on the left when viewed from the front of the fitting.
7) Undo and remove cover, handle, rosette, and base seal. Screw backnut and washer
fully onto side valve shank.
8) From underside pass shank through the hole in the counter-top then screw the
rosette with base seal onto shank until the thread can be seen above the rosette.
9) Ensure the connection for flexible hose is facing the nozzle and tighten backnut and
fibre washer up to the underside of the counter top by hand to stop sidevalve from
rotating.
10) Connect flexible hose from nozzle to sidevalve outlet. Screw the cover and handle
onto the sidevalve ensuring that the handle is correctly aligned. If not, remove and
turn the plastic vernier insert a few splines until the correct alignment has been
achieved.
11) Unscrew the rosette until it meets the cover and fully tighten backnut and fibre
washer up to underside of counter-top.
12) Connect the Hot & Cold water supplies to the side valve inlets.
13) Important - Checkthat flexible hoses are not twisted or kinked as this will restrict the
flow.
Rinse
14) The rinse units require a 30mm diameter hole through the surface they are to be
installed on. Assemble rinse unit socket ensuring the base seal is in place under
body. Attach the tapered end of the flex to the rinse unit. Check that the Non-Return
valve is fitted in the externally threaded end of the flex. If not, push the Non-return
valve into the bore, ensuring that it is correctly orientated. Pass the flex through the
socket, and screw the externally threaded end to the remaining hose at the base of
the mixer tap.
The Traditional Kitchen Collection
Installation & User Guides
Perrin & Rowe isa registered trademark of Avilion Limited. Gateway XIII, Ferry Lane, Rainham, Essex, RM13 9JY, United Kingdom.
T +44(0)1708 526361 F +44(0)1708 550220 E sales@avilion.co.uk W www.avilion.co.uk
904370E
9.17384*
9.25384
9.20384*
9.24193*
9.19193*
9.12451
9.26410
9.30700
9.03700
9.28400
9.26400
9.18380*
9.18700*
9.13146
9.06401
9.01453/HOT
9.01453/COLD
9.13145/COLD
9.13146/HOT
9.21450/RED
9.21450/BLUE
Before Use
15) Turn on the Hot and Cold supplies to the tap.
16) Carefully check the installation for leaks.
17) If further building work is to be carried out in the vicinity, cover
the tap with a plastic bag to avoid damaging the finish.
Operation
Ceramic disc valves are fitted as standard. Flow from FULLY OFF to
FULLY ON is achieved by rotating the handles a quarter turn.
Guarantee
For written details of the product guarantee, please contact us at the
address shown below.
Spare Parts
For maintenance and repairs, we recommend you employ a
registered plumber. Before ordering spare parts, determine the
correct reference number from the exploded diagram below. Quote
this number, and where appropriate, the colour of your tap. For
spares, please contact your local distributor or Perrin & Rowe.
Care & Maintenance
Occasional cleaning with warm soapy water, followed by a polish
with a soft cloth is all that is required to keep the plated finish in
good condition.
Do not use proprietary abrasive liquids, powders, or pads to clean
the tap. You will damage the plated finish and void your guarantee.
The aeration device fitted to the hot/cold water outlet may need
occasional cleaning, especially in hard water areas. This is
accomplished by unscrewing the outlet in an anti-clockwise
direction, dismantling and leaving the inner screen mesh immersed
overnight in vinegar or lemon juice.
DO NOT use chemical descaling liquids for this purpose.
Single flow spouts are fitted with an aerator as standard, a flow
straightener is available on request.
9.17384*
9.25384
9.20360*
9.24193*
9.19193*
9.12451
9.26410
9.30700
9.03700
9.28401
9.26400
9.28400
9.18380*
9.18700*
9.13362
9.06401
9.13146
9.01453/HOT
9.01453/COLD
9.13145/COLD
9.13146/HOT
9.21450/RED
9.21450/BLUE
Exploded Diagram of Athenian Four Hole Mixer with Crosshead Handles E.4375 and with Lever Handles E.4376
9.19426
9.28426*
9.18425*
9.27426*
*Specify Colour *Specify Colour
Exploded Diagram of Athenian Three Hole Mixer with Crosshead Handles E.4370 and with Lever Handles E.4371

This manual suits for next models

4

Other Perrin & Rowe Kitchen & Bath Fixture manuals

Perrin & Rowe MIMAS U.1347 Operation manual

Perrin & Rowe

Perrin & Rowe MIMAS U.1347 Operation manual

Perrin & Rowe Industrial Kitchen 4544HT Operation manual

Perrin & Rowe

Perrin & Rowe Industrial Kitchen 4544HT Operation manual

Perrin & Rowe Minoan E.4365 User manual

Perrin & Rowe

Perrin & Rowe Minoan E.4365 User manual

Perrin & Rowe Mimas 4841 Operation manual

Perrin & Rowe

Perrin & Rowe Mimas 4841 Operation manual

Perrin & Rowe PHOENICIAN E.4360 Operation manual

Perrin & Rowe

Perrin & Rowe PHOENICIAN E.4360 Operation manual

Perrin & Rowe Armstrong 4599HT Operation manual

Perrin & Rowe

Perrin & Rowe Armstrong 4599HT Operation manual

Perrin & Rowe AQUITAINE U.1323 User manual

Perrin & Rowe

Perrin & Rowe AQUITAINE U.1323 User manual

Perrin & Rowe EDWARDIAN U.KIT1323 User manual

Perrin & Rowe

Perrin & Rowe EDWARDIAN U.KIT1323 User manual

Popular Kitchen & Bath Fixture manuals by other brands

Hans Grohe Steel 35800800 quick start guide

Hans Grohe

Hans Grohe Steel 35800800 quick start guide

agape MACH2 AMC20938 Assembly instructions

agape

agape MACH2 AMC20938 Assembly instructions

Gessi RETTANGOLO 39900 manual

Gessi

Gessi RETTANGOLO 39900 manual

Miscea LIGHT Maintenance manual

Miscea

Miscea LIGHT Maintenance manual

Elkay ERS1-1E Installation, care & use manual

Elkay

Elkay ERS1-1E Installation, care & use manual

PEERLESS P1519LF manual

PEERLESS

PEERLESS P1519LF manual

Spectrum Brands Pfister Ashfield LG49-YP1 Quick installation guide

Spectrum Brands

Spectrum Brands Pfister Ashfield LG49-YP1 Quick installation guide

Lefroy Brooks CB-2153 Installation, operating,  & maintenance instructions

Lefroy Brooks

Lefroy Brooks CB-2153 Installation, operating, & maintenance instructions

Kohler IV Georges Brass K-6811-4 Homeowner's guide

Kohler

Kohler IV Georges Brass K-6811-4 Homeowner's guide

Kohler Rada T1 product manual

Kohler

Kohler Rada T1 product manual

Caple SL7/CH Care, Installation and Guarantee Information

Caple

Caple SL7/CH Care, Installation and Guarantee Information

Hans Grohe Logis M31 260 1jet 71835000 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Logis M31 260 1jet 71835000 Instructions for use/assembly instructions

Kohler Beitou 99856T-4 installation instructions

Kohler

Kohler Beitou 99856T-4 installation instructions

Hans Grohe Raindance Rainfal 28433 Series Installation/User Instructions/Warranty

Hans Grohe

Hans Grohe Raindance Rainfal 28433 Series Installation/User Instructions/Warranty

Grohe EUROSMART COSMOPOLITAN T 36 317 manual

Grohe

Grohe EUROSMART COSMOPOLITAN T 36 317 manual

Hans Grohe AXOR Citterio 39835 Series Instructions for use/assembly instructions

Hans Grohe

Hans Grohe AXOR Citterio 39835 Series Instructions for use/assembly instructions

American Standard 1662SG.223 installation instructions

American Standard

American Standard 1662SG.223 installation instructions

Moen 84400 Series quick start guide

Moen

Moen 84400 Series quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.