Phonic PPC1100 User manual

PPC1100/1200
USER MANUAL
PPC1100
PPC1200
www.phonic.com

1
SAFETYPRECAUTIONS!
WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EX-
POSE THIS UNIT TO RAIN OR MOISTURE.
Do not allow water or liquids to be spilled into this unit, if the unit has been exposed to rain or liquids, please
unplugthepower cordimmediatelyfrom theoutlet (withDRYHANDS)andget aqualifiedservice technician to
check. Keep this unit away from heat sources such as radiators, heat registers, stoves etc. that produce heat.
Theunit containsno serviceableparts.Refer allservicing toa qualified
Serviceengineer, throughtheappropriatePhonicdealer.
CAUTION:
TO REDUCE THE RISK OF ELECTRIC SHOCK,DONOT REMOVE COVER (OR BACK).
NOUSER-SERVICEABLEPARTSINSIDE.REFERALLSERVICINGTOQUALIFIEDSER-
VICEPERSONNEL.
Keep this unit away from dust and dirty environment. Using a soft dry brush and occasionally wipe this unit with
a damp cloth, do not use any other solvents, which may cause damage to paint or plastic parts. Regular care
and inspection will be rewarded by a long life and maximum reliability.
Your Phonic PPC 1100/ PPC 1200 was carefully packed in the factory and the packing box was designed to
protect the unit from rough handling. We recommend that you carefully examine the packaging and its contents
foranysigns ofphysical damage,which mayhave occurredin transportation.
If the unit isdamaged: Notify your dealer and the shipping company immediately.Claimsfor
damage or replacementmaynot begrantedif fail to report itproperly.
This triangle, which appears on your com-
ponent, alerts you to the presence of
uninsulated“dangerous voltage”insidethe
enclosure that may be sufficient to consti-
tute a risk of shock.
Thistriangle, which appearsonyour com-
ponent, alerts you to important operating
andmaintenanceinstructionsinthisaccom-
panyingliterature.

2
CONTENTS
1. INTRODUCTION ........................................................................................3
2. INSTALLATION..........................................................................................3
2.1 RACK MOUNTING ............................................................................................... 3
2.2 CONNECTORS .................................................................................................... 3
3.CONTROLS ................................................................................................4
4. SPECIFICATIONS .....................................................................................6

3
1. INTRODUCTION
The PPC 1100/ PPC 1200 Power Conditioner/Light Module is the perfect accessory to any equipment rack,
providing the working light to the rack and basic power protection essential to your equipment on the rack. Install
aPPC 1100/ PPC1200 inthe topslot ofyour rack, andthe eightswitchedACoutlets on the rear panel will power
upall yourequipmentwhileits twoslide-out lightfixturesprovide discreet, illuminationoftheircontrols inanydark
place. A dimmer control allows you to have the suitable lamp brightness. PPC 1200 has a digital line voltage
displayformonitoring currentvoltage ata glance, whilePPC 1100 doesn
’
t.
PPC 1100 Features
zTwo slide out, swiveling rack lights with dimmer control
zEightaccessory outletsin therear,controlled bya frontpanelswitch,widely spaced toallow formaximumuse
of
“
wallwart
”
plugs
z15-amp rating with circuit breaker protection
zIlluminated on-off switch
zSeparate switch for lamps
zSeven feet heavy dutyAC cord
zAn additional unswitched outlet on front panel
zPPC1100 availablein 100V~120Vand 220V~240V,dependingon countries
PPC 1200 Features
zIncludes all PPC 1100 features, plus the following
zTriple-modevaristor spikeandsurge protection
zImprovedRFI filteringwith highattenuation multi-stagefilter
zDigitalline voltagedisplay formonitoring currentvoltage from90V~150Vfor120Vversion, 175V~285Vfor
230Vversion.
zPPC1200 availablein 100V~120Vand220V~240V, dependingoncountries
2. INSTALLATION
2.1 RACK MOUNTING
ThePower Conditioner/LightModulemay beinstalledin astandard 19inch equipment rack. Itrequires1.75
inchesof verticalrack space and securesto the rackcabinet withfourrack mountscrews and cupwashers.
Normally PPC1100/1200 is installed at the top of rack for lighting equipment on the rack.
2.2 CONNECTORS
It provides eight accessory outlets in rear panel, controlled by front switch and an additional unswitched
outleton thefront panel.

4
3.CONTROLS
PPC1100
PPC1200
11
11
1. MASTER SWITCH:
Use this switch to turn the power on and off for the rear eight outlets.The illuminated switch will come on when
the power is on.
22
22
2. LAMP SWITCH:
Use this to turn on the two slide out, swiveling rack lights which allow you to check the equipment settings
before applying power to it. This switch is independent from the master switch.
33
33
3. RACK LIGHT:
Two slide out, swiveling rack lights with dimmer control. Pull it out and turn to oppropriate down angle when you
need them to give light to the equipments on the rack.
44
44
4. DIMMER CONTROL:
Use this control to adjust the brightness of the rack light.
55
55
5. UNSWITCHED OUTLET:
Thereis an additional unswitchedoutleton thefront panel forconvenient temporaryuse.It isindependent from
the master switch. Its power will be turned on when the built-inAC cord on the rear panel is plugged into the
mainpower.

66
66
6. CIRCUIT BREAK:
The front circuit breaket can be easily and quickly reset should the PPC 1100/ PPC 1200 be overloaded.
77
77
7. DIGITAL LINE VOLTAGE DISPLAY: (PPC 1200 ONLY)
This is for monitoring the input voltage.The number will tell you how much voltages has been sent to this unit.
88
88
8. AC OUTLETS:
The eight switchedAC outlets on the rear panel , controlled by front master switch, power up all your equip-
ment. They are widely spaced for maximum use of
“
wall wart
”
plugs.
99
99
9. AC CORD
Connectthis built-inpower cordto yourpower source.
5

6
4. SPECIFICATIONS
zCurrentrating: 15amps
zPPC1200only: includingaDigitalline voltagedisplay
zInputvoltage: either100-120VAC60Hz or220-240VAC, 50Hz,dependingon whereyou are located.
zSpikeProtection Modes: Lineto neutral,neutral to ground, line toground. (PPC1200only)
zNoise attenuation: Transverse and common modes: 20dB at 200K Hz, rising to >40dB, 1 to
100MHz.(PPC1200only)
zLamps: 7 watt night-light bulbs.
zConstruction:Steel chassis, black paint coatingwith lacquer; champagne color aluminumfront panelwith
anode processing.
zDimensions(HxWxD): 1.75" H x 19" W x 6"D(44x482x152 mm)
zWeight: PPC 1100, 5.37 lbs (2.44Kg); PPC 1200, 5.64 lbs (2.56Kg)
Specifications are subject to change without notice.