Installation:
The Messager USB Night Answer should be installed using the following steps:
Step 1: Set the DIP switches on the bottom of the unit to the amount of rings required to trigger the night message
greeting. Default setting is two rings when all switches are OFF.
Answer On X Rings Switch A Switch B Switch C Switch D
2 OFF OFF OFF OFF
3 ON OFF OFF OFF
4 OFF ON OFF OFF
5 ON ON OFF OFF
6 OFF OFF ON OFF
7 ON OFF ON OFF
8 OFF ON ON OFF
9 ON ON ON OFF
10 OFF OFF OFF ON
11 ON OFF OFF ON
12 OFF ON OFF ON
13 ON ON OFF ON
14 OFF OFF ON ON
15 ON OFF ON ON
16 OFF ON ON ON
17 ON ON ON ON
Step 2: Wall or shelf mount the unit. Screws and rubber feet are supplied in the accessory kit.
Step 3: If connecting to an amplier make sure it is turned OFF for this part of the installation.
Step 4: Connect a RCA cable (supplied in the accessory kit) to the OUTPUT jack on the rear of the unit. Depending
upon the required impedance use either the 8Ω or 600Ω output RCA jack. Connect the other side to the MOH port
on the phone system, PA system or speaker.
Step 5: Connect to an RJ-14 cord from the TELCO jack on the rear of the unit to the phone line to be monitored
by the Messager USB Night Answer.
Step 6: If utilizing a trigger timer or other device to activate the Night Answer Mode then connect the 1/8˝ plug
into the TRIG jack on the rear of the unit.
Step 7: Insert USB media. If insertion of drive is difcult, turn the drive over and try reinserting. Drive should
slide into jack smoothly. See Message Programming & Operation section if USB media is blank.
Step 8: Attach the included power pack to a wall or power strip receptacle, then attach the other end to the jack on
the rear of the unit labeled 12VDC.