PISCO VJ Series User manual


VJ check type structure
compressor
Built-in spring type check valve.
Dry unit
Check functionCheck function
3 types for supply valv
Wide variety of combinations can cope with variousneeds.
External Vacuum Controller for Vacuum Pump Series is for
available
For the pipe lead-out direction of concentrated piping of
manifold-type, two types are available; front lead-out
typeand rear lead-out type.
It is designed to adjust the breaking flow and breaking pressure at the same time to prevent scattering or locking of work
piece which is difficult to control by only breaking flow adjustment.
By adding a relief function to the vacuum breaker circuit, the vacuum breakdown time has been shortened for the first
time in the industry.
The vacuum sensor is an LED-indicated digital sensor (V4).
The basic specification : 2 switch output and analog output
Standard nozzle bore: 05(ø0.5mm), 07(ø0.7mm), 10(ø10mm) and 12(ø1.2mm).
Doble solenoid type
(Vacuum retention type, selectable for saving energy)
Normally closed type
Normally open type
- Built-in Spring type check valve.
- Stable long time check.
- Vacuum ON / OFF can be performed in one operation when energy saving sensor is used.
Check function
Maintain vacuum
residual pressure
for at least 4 hours
keeping vacuum
compressor off
Vacuum genelrator VJ
keeping workpiece
adsorption
2
Vacuum PAD
work
Blow-off air rate adjustment needle Blow-off pressure adjustment needle
Blow-off air flow control
Blow-off air
Blow-off pressure control
Vacuum Generator
※ Vacuum failure air means the
air blowing to release the vacuum.
Vacuum Pad
Tiny and light work-piece
Prevent blowing away work-piece

External Pilot Type Launch
Energy saving vacuum generator
Port for nozzle supply
External Pilot Port
Energy saving vacuum generator.
Operation method of the sensor with energy saving function.
Cut of air, when built-in vacuum pressure sensor (with energy saving function) set vacuum valve.
Pressured air consumption
Check function
Vacuum
V/V N.C
Saving
sensor
decrease and more
3
Saving air consumption when keeping
long time check
Applied N.O type and vacuum protection
General vacuum sensor applied
Since the external pilot type is special order, please contact nearest sales office or distributor.
P1 : Switch output value(SW1)
P2 : Switch output value(SW2)
H1 : The value of course(SW1)
H2 : The value of course(SW2)
Suction command
(Sensor pressure)
COMMAND
Breaking valve
(Solenoid valve)
SW2
(Sensor output)
SW1
(Sensor output)
Atmospheric
pressure
Vacuum
Detecting
pressure

4
Construction
Stand-alone type without Vacuum switch
Stand-alone type with Vacuum switch
Manifold type without vacuum switch
Manifold type with vacuum switch
Blow-off unit Ass’
Connector
Ejector unit Ass’
y
Blow-off unit Ass’
Connector
Ejector unit Ass’
y
Pilot valve Ass’y
y
Filter unit Ass’y
Valve unit Ass’y
Filter unit Ass’y
Sensor unit Ass’y
Pilot valve Ass’y
Valve unit Ass’y
y
Blow-off unit Ass’
Connector
Ejector unit Ass’
y
Pilot valve Ass’y
Valve unit Ass’y
y
Manifold
Filter unit Ass’y
Filter unit Ass’y
Sensor unit Ass’y
Blow-off unit Ass’
Connector
Ejector unit Ass’
y
Pilot valve Ass’y
Valve unit Ass’y
y
Manifold

Code
Size
Code
Size
5
Model Designation (Example)
Complex Vacuum
Generator
Vacuum
Characteristic
Nozzle
Bore
Suction solenoid
Valve type
Vacuum
Port
Air supply
Port
Exhaust
Port
Solenoid valve
Voltage
Wire lead-out
Direction
Check valve
specification
No.of stations
(Only for manifold type)
Lead-out direction of air-supply&
Exhaust port(Only for manifold type)
Vacuum sensor
Vacuum characteristics
Nozzle bore
Suction solenoid valve type
Vacuum port (Applicable tube size)
Air supply port (Abblicable tube size)
Code Performance Performance PerformanceCode Code
High-vacuum type High-vacuum type
Combination of different vacuum characteristics on mouting units on a manifold (Details should be described on Specification Order Form separately)
High-vacuum at low air pressure type
Code Air consumption
Nozzle
bore
H type
Vacuum lever, Suction flow
L type
Vacuum lever, Suction flow
E type
Vacuum lever, Suction flow
※ Supply pressure is 0.5MPa for H and L type and 0.35Mpa for E type.
※ Air consumption values in ( ) represents that of E type.
00 : With manifold types, when port size differs with each station.(Details should be descrived in Specification order form.)
※1. Stand-alone type only.
※2. Manifold type only.
Valve unit Valve unit Valve unitCode Code Code
Double solenoid type (Vacuum retention type)
Normally closed type
Combination of different vacuum characteristics on mounting units on a manifold (Details should be described on Specification Order Form separately)
Normally open type

6
Model Designation (Example)
Exhaust port
Solenoid vavle type
Wire lead-out direction
Check vavle specification
Lead-out direction of air-supply & exhaust port (Only for manifold type)
Vacuum switch
No.of stations(Only for manifold type)
Stand-alone type
Manifold type
Code
Size
Code
Working voltage
Code
Lead-out
direction
Code
Size
Open to air (Silencer vent)
Open to air
Individual concentrated exhaust
ø8 one-touch fitting type
ø10 one-touch fitting on both sides
with concentrated exhaust
ø8 one-touch fitting on both sides
with concentrated exhaust
Tube exhaust (Push-in fitting) ø8
Top Side Different directions on mounting units
(Specification Order Form required)
Code No Code
Size
Without check valve Check valve included
Code
No.of manifolds
Code
Lead-out direction
Vacuum port side Solenoid valve side
Code
Switch
Type
NPN open collector
Button-type vacuum sensor
2 switch output and analog output
Energy saving sensor
1 switch output
Different vacuum switches on mounting units
(Specification Order Form required)
※ When using the DWE energy saving sensor, select N.C Type for the vacuum generator valve.

7
Ordwe example
Vacuum Generator Stand-alone type
Vacuum Generator Manifold type
Vacuum Generator Manifole type (Different mounting units on a manifold)
Vacuum characteristics : H → High-vacuum type
Nozzle bore : 05 → Ø0.5mm
Vacuum port : 04 → Ø4mm Push-In Fitting
Air supply port : 06 → Ø6mm Push-In Fitting
Exhaust port : S → Open to air(Silencer vent)
Solenoid valve type : D24 → DC24VDC
Wire lead-out direction : L → Top
Check function selection : CV-check specification
Vacuum switch : V4 → 2 switch + analog output
DWE → Energy saving 1 switch
Suction solenoid valve type : A → Double solenoid type (Vacuum retention type)
Vacuum characteristics : H → High-vacuum type
Nozzle bore : 05 → Ø0.5mm
Vacuum characteristics : K → St.1, St.2, : H type
Vacuum port : 00 → St.1, St.2, St.3 : Ø0.6mm Push-In Fitting
St.4 : E type
St.5 : H type
Nozzle bore : 00 → St.1, St.2, St.3 : Ø0.5mm
Suction solenoid vavle type : K → St.1, St.2, St.3 : Double solenoid type
St.4 : Ø1.0mm
St.4, St.5 : Ø8mm Push-In Fitting
St.4, St.5 : Normally closed type
St.5 : Ø1.2mm
Vacuum port : 04 → Ø4mm Push-In Fitting
Air supply port : 10 → Ø10mm Push-In Fitting
Air supply port : 10 → Ø10mm Push-In Fitting
Exhaust port : 10 → Ø10mm Push-In Fitting
Exhaust port : 10 → Ø10mm Push-In Fitting
Solenoid valve type : D24 → 24VDC
Solenoid valve type : D24 → 24VDC
Wire lead-out direction : L → Top
Wire lead-out direction : L → Top
Check function selection : CV-check specification
No.of stations : 04 → 4 stations
Check function selection : CV-check specification
No.of stations : 05 → 5 stations
Lead-out direction of air-supply & exhaust port : A → Vacuum port side
Vacuum switch : V4 → 2 switch + analog output
DWE → Energy saving 1 switch
Lead-out direction of air-supply & exhaust port : A → Vacuum port side
Vacuum switch : K → St.1, St.2, St.3 : V4 → 2 switch + analog output
St.4 : Without vacuum switch
Suction solenoid valve type : A → Double solenoid type (Vacuum retention type)

Example of Manifold Type
Vacuum Generator VJ series Specification Order Form
Specification Order Form (ex) : Vacuum Generator Manifold type in the previous page
8
L side
Vacuum port
Exhaust port
Air supply port
R side
※ Station no.is arranged St.1, St.2 … St.10 from L side.
Manifold model code
Mounting unit
model code
L
St.
no.
R
Vacuum
characterisics
Nozzle
bore
Vacuum
port
Exhaust
port
Vacuum
switch
Air supply
port
Check
valve
No.of
stations
Solenoid
valve type
Wire lead-out
direction
Lead-out direction
of air-supply&
exhaust port
Suction solenoid
valve type
Manifold model code
Mounting unit
model code
L
St.
no.
R
Vacuum
characterisics
Nozzle
bore
Vacuum
port
Exhaust
port
Vacuum
switch
Air supply
port
Check
valve
No.of
stations
Solenoid
valve type
Wire lead-out
direction
Lead-out direction
of air-supply&
exhaust port
Suction solenoid
valve type
TO : PISCO KOREA PNEUMATIC CO.,Ltd.
---- Order in the following format ----
Manager :
Company name :
Manager: Department:
Quantity of order: Delivery:
Position: Name:

Example)
(Valve unit type : Double solenoid type (Vacuum retention type))
Mechanism of VJ
9
At vacuum generation suspended
At vacuum retention
At vacuum generation suspended At vacuum generating
At blowing-off
At vacuum generating
Blow-off air rate adjustment needle
Blow-off pressure adjustment needle
Blow-off solenoid valve
Blow-off switch over valve
Suction switch over valve
Blow-off air rate adjustment needle
Retention of suction switchover valve
Vacuum switch
Relief air
Ejector
Ejector
Filter
Suction solenoid valve
Example)
(Valve unit type : Normally closed)
Blow-off pressure adjustment needle
Blow-off solenoid valve
Ejector
Filter
Suction solenoid valve
At vacuum retention At blowing-off
Blow-off switch over valve
Suction switch over valve Vacuum switch
Relief air

Specification
Ejector characteristics
Solenoid valve (Suction solenoid valve / Blow-off solenoid valve)
10
Fluid medium
Model code Model code Final vacuum Suction flow Air sonsumption
Operating pressure range
Rated supply pressure
Operating temp.range
Air
type type
※ Secure supply pressure as listed when the vacuum generator is in operation.
※ The values in the table are reference values only. Suction flow varies according to the vacuum system conditions;
vacuum port ia. or tube length.
※
The above characteristics are the values measured at the rated supply pressure which is 0.5MPa for H and L type and 0.35MPa for E type.
Pilot valve
Item
Suction solenoid valve Blow-off solenoid valve
Suction solenoid valve Blow-off solenoid valve
Operating system
Valve construction
Item
Operating system
Valve construction
Proof pressure
Valve type
Lubrication
Effective sectional area
Min. excitation time
Rated voltage
Allowable voltage range
Surge protection circuit
Power consumption
Manual operation
Operation indicator
Wiring type
Direct operation
Diode
Red : DC24V
Black : COM
Red : DC24V
Black : COM
Blue Blue
1.2W(with LED) 1.5VA(with LED)
Push & Lock type
1.2W(with LED) 1.5VA(with LED)
Diode bridge Diode Diode bridge
Elastic seal, Poppet valve
During coil excitation, Red LED is on
Pneumatic operation by pilot valve
Elastic seal, Poppet valve
Normally closed
50msec(Double solenoid type only)
Not required
Air supply port
diameter
Double solenoid(retention type)/Normally closed/Normally open
Connector wire (cable length : 500mm)

11
LED Display Digital Vacuum Sensor
Button type compound pressure sensor (-V4)
General
specifi-
cations
Pressure
range
Power
supply
Display
Switch
Analog
output
Fluid medium
Operating temp. range
Preservation temp. range
Operating humidity range
Display method
Non-corrosive gas
0~50°C (No freezing)
-20~70°C (No freezing)
35-85%RH (No dew condensation)
Pressure gauge
Operating pressure range
Pressure proof
Rated voltage
Current consumption
Panel lock function
Non-display function
Pressure display unit
Display Display resolution
Indication accuracy
Zero point adjustment
Output points
Output method
Switch capacity
Residual voltage
Output mode
Pressure setting range
Operational indication
Temperature characteristics
Repeat accuracy
Response time
Hysteresis adjustment
Overload protection
Output voltage
Voltage with max negative
pressure applied (-100kPa)
Voltage with negative
pressure applied (-90kPa)
Zero point voltage
Voltage with Max positive
pressure applied (300kPa)
Linearity
Repeat accuracy
Temperature characteristics
-100kPa - 300kPa
1.471MPa
DC12~24V ± 10%
30mA Max
On/Off by push button
On/Off by push button
kPa
1kPa
±3%F.S. (0~50°C, at Ta=25 °C)
Adjustable by zero adjusting mode
2 point switch outputs
NPN open collector
DC30V 80mA Max
1.2V Max (at load current 80mA)
Separate mode, Window comparator mode
-8~30 counts (kPa setting)
Output On : LED ON (SW1 : Red, SW2 : Greend)
±5%F.S. (0~50°C, at Ta=25°C)
±3%F.S.
Filter setting at 0 msec : 5msec
0~30counts
Equipped
1+0.06V
1~5V
1.1±0.06V
2±0.06V
5±0.06V
±0.5%F.S.
±0.5%F.S.
±5%F.S. (0-50°C, at Ta=25 °C)

12
0 ~ 50 /min[ANR] (Rated supply pressure: 0.5Mpa)
Filter specification
Element material PVF (Polyvinyl formal)
Filtering capacity
Filter area
Replacement filter
model code
Blow-off function
Blow-off air rate
Valve structure Elastic seal, Poppet valve
Relief pressure setting range 500.0 ~
0.05MPa

Specifi-
cations
Pressure
range
Power
Display
Switch
output
Fluid medium Air (non-corrosive)
Pressure Detection Semi-conductor pressure switch
Operating temp. range 0~50
Storage temp. range -20~70'C (Atmospheric pressure, humidity less than 65%)
Operating humidity range 35~85% (No freezing)
Vibration resistance 100m/s
Shock resistance 150m/s
Protection
Operating pressure range
Protection
Operating pressure range
Pressure indicator
Display count
Surveillance function
Panel Lock function
Non-display function
Special
function
Accuracy of display
Temperature characteristic
Zero point adjustment
Output points
Output method
Switch capacity
Residual voltage
Output operation
Pressuresetting
range
Operation display
Temperature characteristic
Repeatability
Responsiveness
Hysteresis setting
Overload protection circuit
Protection
IEC standard IP40 equivalent
DC12~24V ±10% (Inc. Ripple P-P)
MAX. 30mA or less than (All lights, 2-point output no load ON)
2 spaces 7segment Red LED (Character height 4.5mm)
4times/sec
Pressure over indication, flashing indication
Enable / disable selection by button operation
Enable / disable selection by button operation
Configure zero adjust mode
1 point output
NPN open collector
DC30V 80mA or less than
1.2V or less than (When NPN, load current 80mA)
Separate mode, window comperator mode
1ms or less than
Variable by hysteresis setting, 0 to 90 kPa equivalent
Available
Output ON : LED light on (SW1 : red / SW2 : green)
13
DWE Saving sensor (DWE)
±1%F.S. ± 1count
±3F.S. ± 1count (0 ~ 50° at Ta=25°C
±5%F.S. ± (0 ~ 50°at Ta=25°C
-99 ~ 0 (kPa)
.00 ~ 0.12(MPa)
-99 ~ 0 (kPa)
.00 ~ 0.36(MPa)
±0.3%F.S.

Type Model code Weight(g) Remarks
Model code Weight(g) Remarks
Weight(g) Remarks
Weight(g)
Manifold intermediate block
Total weight can be calculated by the follwing calculation formula.
Total weight of manifold type = (①Stand-alone type + ②Manifold intermediate block) X station qty +
③Manifold Side block + ④Cartridge X qty
Per station
Remarks
Vacuum port : Ø4, Ø6 Cartridge qty : 2pcs (PS port)
PV and EX ports have plugs.
Cartridge qty : 4pcs (PS and EX ports)
PV ports have plug.
For Ø6mm
For Ø8mm
For Ø10mm
silencer vent with
vacuum switch silencer vent
Tube exhaust
silencer vent without
vacuum switch
silencer vent with
vacuum switch
silencer vent without
vacuum switch
Vacuum port : Ø8
Vacuum port : Ø8
Vacuum port : Ø8
Vacuum port : Ø8
Vacuum port : Ø4, Ø6
Vacuum port : Ø4, Ø6
Vacuum port : Ø4, Ø6
14
Circult diagram (solenoid valve)
VJ Series weight list
Characteristics
Blue
DC24V Suction & Blow-off solenoid valve AC100V Suction & Blow-off solenoid valve
Blue
(Red)(Black)
① Stand-alone type
Supply pressure - Final vacuum, Suction flow, Air consumption
② Manifold intermediate
④ Cartridge (supply and exhaust ports)
③ Manifold side block
Vacuum characteristics Flow characteristics Vacuum characteristics Flow characteristics
Vacuum characteristics Flow characteristics Vacuum characteristics Flow characteristics
Supply pressure : 0.5MPa (H,L type)
L type
E type
L type
H type
H type
E type
H type
H type
H type
H type Final vacuum
L type Final vacuum
E type Final vacuum
Air cons umption
H type
suction flow
E type
suction flow
L type
suction flow
Supply pressure : 0.5MPa (H,L type)
, 0.35MPa (E type)
Final vacuum (-kPa)
Supply pressure (MPa) Suction flow
Final vacuum (-kPa)
Supply pressure (MPa) Suction flow
Flow rate
Vacuum pressure (-kPa)
Supply pressure : 0.5MPa (H,L type)
Final vacuum (-kPa)
Supply pressure (MPa) Suction flow
Flow rate
Vacuum pressure (-kPa)
Vacuum pressure (-kPa)
Flow rate
Supply pressure : 0.5MPa (H,L type)
, 0.35MPa (E type)
Final vacuum (-kPa)
Supply pressure (MPa) Suction flow
Vacuum pressure (-kPa)
Flow rate
H type Final vacuum
L type Final vacuum
E type Final vacuum
E type Final vacuum
H type Final vacuum
H type Final vacuum
L type Final vacuum
Air cons umption
Air cons umption
H type
suction flow
L type
suction flow
L type
suction flow
E type
suction flow
E type
suction flow
H type
suction flow H type
suction flow

15
① Tube insertion
In the characteristics shown above, supply pressures refer to those when vacuum is generated.
In the characteristics shown above, an odd noise may be heard when supply pressures are immediately
before the peak of vacuum levels (H (High vacuum) type: 0.4~0.45MPa, and E (High-vacuum at low air
supply pressure type) type: 0.29~0.32MPa). The sounding of this odd noise means the characteristics
are unstable. If nothing is done, the sound may become even noisier. This situation can also adversely
affect the sensor, resulting in a malfunction or trouble. So reset the supply pressure.
(Ex. 1: When the vacuum generator H type is in operation with the original pressure of 0.5MPa, the
odd noise began to be heard due to a drop in supply pressure to 0.43MPa. Reset the supply pressure
for the vacuum generator in operation at 0.5MPa.)
Piping design and equipment selection should be made with an effective sectional area being 3 times as
large as the nozzle diameter as a standard. Satisfactory vacuum characteristics are not obtained unless
sufficient supply air flow is secured.(For example, the odd noise is heard even when pressure is at the set
value, suction flow is insufficient, the final vacuum does not satisfy the required level, etc.) (Example2.
There is the odd noise from the vacuum generator H type, though the supply pressure is 0.5MPa. →
Insufficient supplied air rate is the cause. The supplied air rate is reduced before the vacuum generator
by a pipe resistance, and a proper air rate is not obtained. Select tubes and pneumatic apparatuses with
the target effective cross-section areas obtaining the necessary air flow rate.) (Example3. When
ø1.0mm of nozzle bore is selected, the effective cross-section size should be more than
2.35mm2.(cross-section 0.52xπ=0.785mm2x3=2.35mm2). Select tubes and pneumatic apparatuses with
the effective cross-section area more than 2.3 mm2.)
Insert a tube into Push-In Fitting of the vacuum generator VK up to the
tube end. Lock-claws bite the tube to fix it and the elastic sleeve seals
around the tube. Refer to “2. Instructions for Tube Insertion” under
“Common Safety Instructions for Fittings”.
Characteristics
1. How to insert and disconnect
② Tube disconnection
The tube is disconnected by pushing release-ring to release Lock-claws.
Make sure to stop air supply before the tube disconnection.
In order to fix the vacuum generator VK, tighten M3
threads through the fixing holes on the resin body with
tightening torque 0.3 to 0.35Nm. Refer to the outer
dimensional drawings for the hole pitch.
For general type and check valve internal waste, the position
of the cabinet is different. Please refer to this information.
2. How to fix the product

16
Warning
caution
Detailed safety instrution
Please read it before use, Appendix-P.38 for 'Safety Precautions', Appendix P.40 for 'Common Precautions
for products', and Appendix P.44 for 'Common Precautions for Vacuum Equipment'.
Make sure that the leakage current is less than 1mA, when operating a valve unit. Leakage current larger
than that may cause malfunction.
Vacuum generator with vacuum retention function permits some vacuum leakage. Provide an appropriate
safety measure when vacuum retention for long period of time is required.
The coil in a pilot solenoid valve generates heat under the following ①-③ conditions.The heat may cause
dropping life cycle, malfunctions and burn or may affect negatively on peripheral machines. Contact us when
the power is applied to the vacuum generator under the following conditions:
①The power is continuously ON for over 2 hours.
②High-cycle operation.
③ Even when intermittent running of the generator is carried out, the total operation time per day is longer than
non-operation time.
Regarding double-solenoid types (VJ□□A…), the switchover valve (main valve) is placed in neutral after
the supply of pilot air has been suspended (the same is true when the valve is being operated for the first
time after shipment). When resuming the supply of pilot air, be sure to send a signal to the pilot valve, or
conduct switchover operations manually as required.
Do not give an excessive tensile strength and bending on a lead wire. Otherwise, breaking wire or damage
on connector may be caused.
When manifold type is selected, dropping the performance or having an effect to other vacuum ports can
be caused depending on number of stations or a combination of mounting units. Contact us for any unclear
points.
Compressed air contains many kinds of drains such as water, oxidized oil, tar and other foreign substances.
Dehumidify the compressed air by using an after-cooler or a dryer and improve the air quality, since those
drains seriously impair the performance of the vacuum generator.
Do not use lubricators.
Since pipe rust cause malfunctions, a filter finer than 5μm should be placed right before the air supply port.
Do not use the vacuum generator under the condition of corrosive and / or inflammable gas. Also do not
use these gasses as fluid medium.
Do not operate a blow-off valve during vacuum generating.
When replacing vacuum port cartridge, first remove any foreign substances clinging to them and the
surrounding areas, then firmly insert pins into cartridges.
When replacing a supply port block, make sure not to lose the seal rubber and remove the foreign substances
stuck around the block. Tighten the screw to fix the block with 0.27-0.3Nm of the tightening torque.
For check type, if the vacuum port is closed when the vacuum is blown-off, the residual pressure in the check
valve may be applied and vacuum switching may not be possible.
In above case, disassemblling vacuum filter module will release residual pressure and it will operated again.

17
Standard product table
Concentrated exhaust Atmospheric open
Normally close Normally open Normally close Normally open
Normally close +V4 Normally open +V4 Normally close +V4 Normally open +V4
Vacuum protection type
(double valve)
Vacuum protection type
(double valve) + V4
Vacuum protection type
(double valve)
Vacuum protection type
(double valve) + V4
Vacuum protection type
+ CV(Check valve)
Vacuum protection type
+ CV(Check valve) + V4
Vacuum protection type
+ CV(Check valve)
Vacuum protection type
+ CV(Check valve) + V4
CV(Check valve)
+ DWE(Energy saving)
External pilot function is available for all orders
Please contact your local dealer or our head office.
External pilot function is available for all orders
Please contact your local dealer or our head office.
External pilot type CV(Check valve)
+ DWE(Energy saving)
External pilot type
LED
Display Digital
Vacuum Sensor
LED
Display Digital
Vacuum Sensor
LED
Display Digital
Vacuum Sensor
LED
Display Digital
Vacuum Sensor
LED
Display Digital
Vacuum Sensor
LED
Display Digital
Vacuum Sensor

18
Dimensional drawing
VJ Tube exhaust, wire-lead out direction : Top
VJ Tube exhaust, wire-lead out direction : Side
See the above circuit diagram
for the one for this type.
Blow-off pilot valve
Suction pilot valve
øD2:Vacuum port
øD2:Vacuum port
øD1:Air supply port
Blow-off pilot valve
Suction pilot valve
øD1:Air supply port
About 500
Blow-off pressure
adjustment needle
Blow-off air rate
adjustment needle
Blow-off pressure
adjustment needle
Blow-off air rate
adjustment needle
Vacuum port
applicable tube O.D : øD2
Air supply port
applicable tube O.D : øD1
Unit: mm Unit: mm
Vacuum port
applicable tube O.D : øD2
Air supply port
applicable tube O.D : øD1
Unit: mm Unit: mm
Circuit diagram
Circuit diagram
Operation indicator LED
Model code
Model code
Manual button
Exhuast port
Operation indicator LED
Manual button
Exhuast port
VJA…(Double solenoid stand-alone type)
VJB…(Normally closed stand-alone type)
VJC…(Normally open stand-alone type)

19
VJ silencer vent, wire-lead out direction : Top
Vj silencer vent, wire-lead out direction : Side
See the above circuit diagram
for the one for this type.
Blow-off pilot valve
Suction pilot valve
øD2:Vacuum port
øD2:Vacuum port
øD1:Air supply port
Blow-off pilot valve
Suction pilot valve
øD1:Air supply port
About 500
Blow-off pressure
adjustment needle
Blow-off air rate
adjustment needle
Blow-off pressure
adjustment needle
Blow-off air rate
adjustment needle
Vacuum port
applicable tube O.D : øD2
Air supply port
applicable tube O.D : øD1
Unit: mm Unit: mm
Vacuum port
applicable tube O.D : øD2
Air supply port
applicable tube O.D : øD1
Unit: mm Unit: mm
Circuit diagram
Circuit diagram
Operation indicator LED
Model code
Model code
Manual button
Operation indicator LED
Manual button
VJA…(Double solenoid stand-alone type)
VJPB…(Normally closed stand-alone type)
VJPC…(Normally open stand-alone type)
Dimensional drawing

20
Dimensional drawing
Tube exhaust type with built-in V4 sensor, wire-lead out direction : Top
Tube exhaust type with built-in V4 sensor, wire-lead out direction : Side
See the above circuit diagram
for the one for this type.
Blow-off pilot valve
Suction pilot valve
øD2:Vacuum port
øD2:Vacuum port
øD1:Air supply port
Blow-off pilot valve
Suction pilot valve
øD1:Air supply port
About 500
About 500
Blow-off pressure
adjustment needle
Blow-off air rate
adjustment needle
Blow-off pressure
adjustment needle
Blow-off air rate
adjustment needle
Vacuum port
applicable tube O.D : øD2
Air supply port
applicable tube O.D : øD1
Unit: mm Unit: mm
Vacuum port
applicable tube O.D : øD2
Air supply port
applicable tube O.D : øD1
Unit: mm Unit: mm
Circuit diagram
VJA…(Double solenoid stand-alone type)
VJB…(Normally closed stand-alone type)
VJC…(Normally open stand-alone type)
Circuit diagram
Operation indicator LED
Exhuast port
Model code
Model code
Manual button
Operation indicator LED
Manual button
Button
Button
Button
Button
Exhuast port
Table of contents
Other PISCO Portable Generator manuals
Popular Portable Generator manuals by other brands

Lifan
Lifan KP2300i-2 owner's manual

Champion
Champion 201271 quick start

Thulos
Thulos TH-OZG005 instruction manual

Briggs & Stratton
Briggs & Stratton 30242 Operator's manual

Generac Power Systems
Generac Power Systems Mobile Power MMG25FHI Specifications

Generac Power Systems
Generac Power Systems 00940-2 Owner's manual and installation instructions