LAN Cable, use first connector in both units, as shown (4)
Flush connector for handset
See Note 1 on page 1.
Remove the four Torx screws and take off
the cover of the Transceiver Unit, to enter
the Supply terminals
Electrical connection SAILOR 7222A VHF/DSC
Flush Mount Kit, p/n POL 7222 FLUSH:
1. 1 pcs. Flush mount kit 407224A-950 for 7224 Control Unit
2. 1 pcs. Handset Flush cable p/n 407224A-990
3. 2 pcs. 2 meter Adapter antenna cable PL259(UHF) female to TNC male for VHF and DSC Antennas
4. 1 pcs. LAN Patch cable 2 meter for LAN connection between Transceiver and Control unit.
5. 1 pcs. Cable for NMEA Position input, p/n 406208-941 for AUX connector
6. 1 pcs. 1.5 meter 3x1.5 power cable for 7226 Transceiver unit
NMEA from Navigator to
AUX Connector:
White NMEA in+
Green NMEA in-
Cable p/n 406208-941
(5)
CU Power cable
Red + 24V DC
Black -24V DC
White connect to
Black -24V DC