Posh Domaine User manual

Page 1 of 2
Posh Domaine Twin Rail Shower Chrome (3*)
Plumbers, please ensure a copy of the Installation
Instructions are left with the end user for future reference
Installation Instructions
Screw the bottom rail connector to a wall stud
making sure it is vertically in line with the top rail
connector. Maximum centre distance between the
top and bottom shower connections is 800mm.
Check the grub screws are wound out. Push the rail
brackets onto the top and bottom rail connectors
until they are against wall. Secure with grub screws.
1. 2. 3. 4.
5.
Clean filter washer
periodically.
Water contains lime which remains on the surface
after the water has evaporated. These lime deposits
can be prevented from forming by wiping
immediately after use.
To clean the chrome-plated surfaces use a soft
cloth, soap and warm water. Never use cleaning
agents that contain a corrosive acid or a scouring
additive.
CLEANING
Do not use any
sharp objects to
clean nozzles
Filter Washer
Ball Joint
800mm - 700mm
Bottom Rail
Connector
Top Rail
Bracket
Bottom Rail
Bracket
Connect the round nut at the bottom of the
overhead tube to the upside outlet of the diverter
valve body.
Make sure a washer is in both ends of the hose.
Screw hose onto lower outlet on wet rail, attach
handset and place firmly in holder. Tilt and rotate
head to the desired position.
6.
Min 13±2mm
Max
○ 25mm
Water Inlet
Connector
Water Inlet
Connector
WATER INLET: RECOMMENDED MINIMUM HEIGHT OF
1800mm FROM FLOOR LEVEL
Install a ½" male threaded connection at the
recommended height on wall, ensuring that a
minimum of 13±2mm of thread protrudes past the
finished wall.
Correct water proofing must be applied.
Loosen the 2 grub screws with the Allen Key supplied
and remove Water Inlet Connector from diverter.
Apply thread tape (or Similar) to the ½’” connection
and screw Water Inlet Connector onto the ½”
connector.
Screw the bottom rail connector to a wall stud
making sure it is vertically in line with the top rail
connector. Maximum centre distance between the
top and bottom shower connections is 800mm.
Check the grub screws are wound out. Push the rail
brackets onto the top and bottom rail connectors
until they are against wall. Secure with grub screws.
1. 2. 3. 4.
5.
Clean filter washer
periodically.
Water contains lime which remains on the surface
after the water has evaporated. These lime deposits
can be prevented from forming by wiping
immediately after use.
To clean the chrome-plated surfaces use a soft
cloth, soap and warm water. Never use cleaning
agents that contain a corrosive acid or a scouring
additive.
CLEANING
Do not use any
sharp objects to
clean nozzles
Filter Washer
Ball Joint
800mm - 700mm
Bottom Rail
Connector
Top Rail
Bracket
Bottom Rail
Bracket
Connect the round nut at the bottom of the
overhead tube to the upside outlet of the diverter
valve body.
Make sure a washer is in both ends of the hose.
Screw hose onto lower outlet on wet rail, attach
handset and place firmly in holder. Tilt and rotate
head to the desired position.
6.
Min 13±2mm
Max
○ 25mm
Water Inlet
Connector
Water Inlet
Connector
WATER INLET: RECOMMENDED MINIMUM HEIGHT OF
1800mm FROM FLOOR LEVEL
Install a ½" male threaded connection at the
recommended height on wall, ensuring that a
minimum of 13±2mm of thread protrudes past the
finished wall.
Correct water proofing must be applied.
Loosen the 2 grub screws with the Allen Key supplied
and remove Water Inlet Connector from diverter.
Apply thread tape (or Similar) to the ½’” connection
and screw Water Inlet Connector onto the ½”
connector.
Important Installation Considerations
1. NOTE: Some showers may not provide an effective shower when used
with gravity fed heated water systems or where pressures are less
than 150kPa at the outlet. Additionally showers with flow rates of less
than 9L/min may not allow the following to function correctly:
_ some instantaneous water heaters
_ some tempering valves
_ some thermostatic mixing valves
2. Some shower heads only operate correctly when hot and cold water
supplies are both mains pressure and may not be suitable for some
instantaneous hot water services.
3. When water pressure is in excess of 500kPa a pressure limiting device
is required in accordance with AS/NZS 3500 1.12 recommendation
www.methven.com
Methven warrants this product against manufacturing defects and that it is suitable for use
under the general operating conditions specified in this instruction sheet. However, regional
regulations apply and may affect your warranty. Please refer to
customer service for full details.
New Zealand
0800 804 222
Australia
1300 638 483
UK
0800 195 1602
98-0284 ISSUE A
DECEMBER 2015
Technical Specifications:
Operating Pressure:
Min: 150kPa/1.5bar
Max: 500kPa/5.0bar*
Optimum: 150kPa/1.5bar - 500kPa/5bar
Operating Temperature:
Hot: Max 80°C*
Cold: Min 5°C
Inlet Connections:
All ½" BSP
* Regional specific regulations apply.
Please refer to your warranty statement at
www.methven.com
TWIN SHOWER SYSTEM
Installation Guide
Recommended installation of pressure limiting
valve if supply exceeds 500kPa
NOTE:
- After installation all connections must be
checked for leaks
- All installations must be carried out in
compliance with relevant water regulations*.
97-3057
Mar-2018
Important Installation Considerations
1. NOTE: Some showers may not provide an effective shower when used
with gravity fed heated water systems or where pressures are less
than 150kPa at the outlet. Additionally showers with flow rates of less
than 9L/min may not allow the following to function correctly:
_ some instantaneous water heaters
_ some tempering valves
_ some thermostatic mixing valves
2. Some shower heads only operate correctly when hot and cold water
supplies are both mains pressure and may not be suitable for some
instantaneous hot water services.
3. When water pressure is in excess of 500kPa a pressure limiting device
is required in accordance with AS/NZS 3500 1.12 recommendation
www.methven.com
Methven warrants this product against manufacturing defects and that it is suitable for use
under the general operating conditions specified in this instruction sheet. However, regional
regulations apply and may affect your warranty. Please refer to
customer service for full details.
New Zealand
0800 804 222
Australia
1300 638 483
UK
0800 195 1602
98-0284 ISSUE A
DECEMBER 2015
Technical Specifications:
Operating Pressure:
Min: 150kPa/1.5bar
Max: 500kPa/5.0bar*
Optimum: 150kPa/1.5bar - 500kPa/5bar
Operating Temperature:
Hot: Max 80°C*
Cold: Min 5°C
Inlet Connections:
All ½" BSP
* Regional specific regulations apply.
Please refer to your warranty statement at
www.methven.com
TWIN SHOWER SYSTEM
Installation Guide
Recommended installation of pressure limiting
valve if supply exceeds 500kPa
NOTE:
- After installation all connections must be
checked for leaks
- All installations must be carried out in
compliance with relevant water regulations*.
Important Installation Considerations
1. NOTE: Some showers may not provide an effective shower when used
with gravity fed heated water systems or where pressures are less
than 150kPa at the outlet. Additionally showers with flow rates of less
than 9L/min may not allow the following to function correctly:
_ some instantaneous water heaters
_ some tempering valves
_ some thermostatic mixing valves
2. Some shower heads only operate correctly when hot and cold water
supplies are both mains pressure and may not be suitable for some
instantaneous hot water services.
3. When water pressure is in excess of 500kPa a pressure limiting device
is required in accordance with AS/NZS 3500 1.12 recommendation
www.methven.com
Methven warrants this product against manufacturing defects and that it is suitable for use
under the general operating conditions specified in this instruction sheet. However, regional
regulations apply and may affect your warranty. Please refer to
customer service for full details.
New Zealand
0800 804 222
Australia
1300 638 483
UK
0800 195 1602
98-0284 ISSUE A
DECEMBER 2015
Technical Specifications:
Operating Pressure:
Min: 150kPa/1.5bar
Max: 500kPa/5.0bar*
Optimum: 150kPa/1.5bar - 500kPa/5bar
Operating Temperature:
Hot: Max 80°C*
Cold: Min 5°C
Inlet Connections:
All ½" BSP
* Regional specific regulations apply.
Please refer to your warranty statement at
www.methven.com
TWIN SHOWER SYSTEM
Installation Guide
Recommended installation of pressure limiting
valve if supply exceeds 500kPa
NOTE:
- After installation all connections must be
checked for leaks
- All installations must be carried out in
compliance with relevant water regulations*.

Page 2 of 2
Screw the bottom rail connector to a wall stud
making sure it is vertically in line with the top rail
connector. Maximum centre distance between the
top and bottom shower connections is 800mm.
Check the grub screws are wound out. Push the rail
brackets onto the top and bottom rail connectors
until they are against wall. Secure with grub screws.
1. 2. 3. 4.
5.
Clean filter washer
periodically.
Water contains lime which remains on the surface
after the water has evaporated. These lime deposits
can be prevented from forming by wiping
immediately after use.
To clean the chrome-plated surfaces use a soft
cloth, soap and warm water. Never use cleaning
agents that contain a corrosive acid or a scouring
additive.
CLEANING
Do not use any
sharp objects to
clean nozzles
Filter Washer
Ball Joint
800mm - 700mm
Bottom Rail
Connector
Top Rail
Bracket
Bottom Rail
Bracket
Connect the round nut at the bottom of the
overhead tube to the upside outlet of the diverter
valve body.
Make sure a washer is in both ends of the hose.
Screw hose onto lower outlet on wet rail, attach
handset and place firmly in holder. Tilt and rotate
head to the desired position.
6.
Min 13±2mm
Max
○ 25mm
Water Inlet
Connector
Water Inlet
Connector
WATER INLET: RECOMMENDED MINIMUM HEIGHT OF
1800mm FROM FLOOR LEVEL
Install a ½" male threaded connection at the
recommended height on wall, ensuring that a
minimum of 13±2mm of thread protrudes past the
finished wall.
Correct water proofing must be applied.
Loosen the 2 grub screws with the Allen Key supplied
and remove Water Inlet Connector from diverter.
Apply thread tape (or Similar) to the ½’” connection
and screw Water Inlet Connector onto the ½”
connector.
Screw the bottom rail connector to a wall stud
making sure it is vertically in line with the top rail
connector. Maximum centre distance between the
top and bottom shower connections is 800mm.
Check the grub screws are wound out. Push the rail
brackets onto the top and bottom rail connectors
until they are against wall. Secure with grub screws.
1. 2. 3. 4.
5.
Clean filter washer
periodically.
Water contains lime which remains on the surface
after the water has evaporated. These lime deposits
can be prevented from forming by wiping
immediately after use.
To clean the chrome-plated surfaces use a soft
cloth, soap and warm water. Never use cleaning
agents that contain a corrosive acid or a scouring
additive.
CLEANING
Do not use any
sharp objects to
clean nozzles
Filter Washer
Ball Joint
800mm - 700mm
Bottom Rail
Connector
Top Rail
Bracket
Bottom Rail
Bracket
Connect the round nut at the bottom of the
overhead tube to the upside outlet of the diverter
valve body.
Make sure a washer is in both ends of the hose.
Screw hose onto lower outlet on wet rail, attach
handset and place firmly in holder. Tilt and rotate
head to the desired position.
6.
Min 13±2mm
Max
○ 25mm
Water Inlet
Connector
Water Inlet
Connector
WATER INLET: RECOMMENDED MINIMUM HEIGHT OF
1800mm FROM FLOOR LEVEL
Install a ½" male threaded connection at the
recommended height on wall, ensuring that a
minimum of 13±2mm of thread protrudes past the
finished wall.
Correct water proofing must be applied.
Loosen the 2 grub screws with the Allen Key supplied
and remove Water Inlet Connector from diverter.
Apply thread tape (or Similar) to the ½’” connection
and screw Water Inlet Connector onto the ½”
connector.
Other manuals for Domaine
2
Other Posh Kitchen & Bath Fixture manuals
Popular Kitchen & Bath Fixture manuals by other brands

SCHÜTTE
SCHÜTTE Ocean installation instructions

Hans Grohe
Hans Grohe Ecos L 1jet 14816003 Instructions for use and assembly instructions

Vallone
Vallone COMO 24 installation instructions

San-Ei
San-Ei K987D-L-BW installation instructions

Danze
Danze D303656T installation guide

Blanco
Blanco TAMPERA Hot manual