Powr-Flite PDF6WRD User manual

POWR-FLITE LIMITED WARRANTY
Powr-Flite will repair or exchange parts for your dryer in the event of a manufac-
turing defect as follows:
P
ARTS: New or comparable rebuilt parts, for one year after original purchase.
LABOR: Carry-in service can be obtained during the warranty period by taking
your dryer to an Authorized Powr-Flite Warranty Service Center.
IMPORTANT WARRANTY CONDITIONS: A purchase receipt or other proof of
date of original consumer purchase also will be required before warranty service
is rendered.
This warranty covers normal use and does not cover damage which occurs in
shipment or failure resulting from alteration, accident, misuse, abuse, neglect, or
improper maintenance.
ST
A
TEMENT: This warranty is not transferable and extends only to the original
purchaser when a new Powr-Flite dryer is purchased from an Authorized Powr-
Fite Dealer.This warranty gives you specific legal rights, and you may have other
rights that vary from state to state.
A Tacony Company, Fort Worth, Texas 76140-1710, Call Toll-Free (800) 880-2913
Operator’s Manual
©Powr-Flite, All Rights ReservedX9261 12.05
Commercial
Downdraft™Fan
Standard F6 Models
PDF6WRD
PDF6WRD-2
https://harrissupplyind.com-ToOrderPartsCall608-268-8080

This appliance must be grounded. If it should malfunction or break down, ground-
ing provides a path of least resistance for electric current to reduce the risk of
electric shock. This appliance is equipped with a cord having an equipment-
grounding conductor and grounding plug. The plug must be plugged into an appro-
priate outlet that is properly installed and grounded in accordance with all local
codes and ordinances.
*This appliance is for use on a nominal 120 volt circuit and has a ground plug (see
illustration, right). Make sure that the appliance is connected to an outlet having
the same configuration as the plug. No adaptor should be used with this appliance.
WARNING - Improper connection of the equipment-grounding conductor can result
in a risk of electric shock. Check with a qualified electrician or service person if you
are in doubt as to whether the outlet is properly grounded. Do not modify the plug
provided with the appliance – if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
*This applies only to North America. Most other countries use 230V circuit.
GROUNDING INSTRUCTIONS
Prong or
Grounding pin
Grounded
Outlet
Grounded
Outlet Box
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE
USING THIS APPLIANCE
When using an electrical appliance, basic pre-
cautions should always be followed.
WARNING- To reduce the risk of fire, electric
shock or injury:
Use only as described in this manual. Use
only manufacturer’s recommended compo-
nents and attachments.
Use only indoors. Do not use outdoors or
expose to rain.
Do not use with damaged cord or plug. If
appliance is not working as it should, has
been dropped, damaged, left outdoors, or
dropped into water, return it to your Authorized
Powr-Flite dealer.
Do no pull or carry by cord, use cord as a
handle, close door on cord, or pull cord
around sharp edges or corners. Keep cord
away from heated surfaces.
Do not unplug by pulling on cord. To unplug,
grasp the plug, not the cord.
Do not handle plug or appliance with wet
hands.
Do not put any object into openings. Do not
use with any opening blocked; keep free of
dust, hair and anything that may reduce air
flow.
T
urn off all controls before unplugging.
Do not attempt to service the unit while appli-
ance is plugged in.
Appliance may cause a fire when operating
near flammable vapors or materials. Do not
operate this machine near flammable fluids,
dust or vapors.
Connect to a properly grounded outlet.
Do not use with any solid state speed control
device.
This unit is thermally protected.
FOR BEST PERFORMANCE
• Keep machine clean and in good operating condition.
• Have machine checked periodically by your Authorized
Powr-Flite Dealer.
• Use only authorized service centers for parts or service.
• Store machine carefully in dry area.
• For optimum drying performance and safety, study and
follow your operators manual.
SAVE THESE INSTRUCTIONS
WARNING
Do not stack dryers more than
4 (four) units high for transport,
5 (five) units high for storage.
https://harrissupplyind.com-ToOrderPartsCall608-268-8080

Air
Movement!
OPERATING INSTRUCTIONS
MAINTENANCE/TROUBLE SHOOTING
1. Plug in to a standard outlet with the correct voltage and amperage for the unit.
2. Place the dryer in the desired operating position.
3. Set the switch at the desired speed: low or high.
4. Check for proper operation before leaving the unit unattended.
Do not move or carry the dryer when it is running.
5 AMP Resettable Circuit Breaker
The F6 Whole Room Dryer™ features a 5 amp circuit breaker that will “trip” if more
than 5 amps of electrical current is drawn through the cord.
Operating Positions
The F6 is designed to operate in multiple positions for any type of drying.
1. Face Down – Set the F6 on the four caster wheels to direct air straight down.
Turn each caster to a 45° angle to the housing for best airflow.
2. Tilt Back – Tilt the F6 backward on the four curved molded legs at an angle
to direct air for elevated drying.
3. Upright – Set the F6 square with the handle on the top to direct air across
a room.
4. Tilt Forward– Tilt the F6 forward on the “standing legs at an angle to direct
airflow along the flow in front of the dryer.
5. Stack for Storage – the F6 Powr-Dryer interlock and stack for easy
storage and transport.
Periodic Maintenance
1. Check power cord for any breaks, seperations or cuts.
2. Make sure the ground pin or grounding prong is intact or
the machine will be unsafe to operate.
Trouble Shooting (if the dryer will not run)
1. Check electrical cord; is it firmly seated in wall outlet
2. Check if dryer circuit breaker is tripped, reset if necessary.
3. Check to see if building circuit breaker is tripped. If circuit
is overloaded, move cord to a different outlet.
4. If using an extension cord, make sure it is in good
condition, proper gauge and firmly connected.
https://harrissupplyind.com-ToOrderPartsCall608-268-8080

ASSEMBLY
ref# part # description
01 X9180+ Housing, Axial Fan
02 PD3C+ Foot, Black Rubber, Short
03 X9098+ Screw, #10 x 1”, A Point, Pan Head
04 X8260+ Nut, 8-32 Lock, w/ Nylon Insert
05 72719A Bracket, Axial Fan Motor
06 X9183+ Grill, Axial Fan
07 X9189+ Label, Round (at Grill)
08 X9195+ Caster Receiver
09 X9240+ Wheel and Socket
10 72020A Screw, Self-Tap, PHMS, Zinc, #12 x 1”
11 X9181+ Motor, 115VAC, .25HP, 4 – Pole
X9181-2+ Motor, 230V, 25HP 4 pole
12 X8209S+ Screw, 1/ 4 -20 x 1/ 2”, Serrated Hex
13 X9065+ Screw, Hex Socket Cap, 1/ 4 -20 x1”,
14 X8990N+ Handle / Wheel Assembly
ref# part # description
15 X8848+ Jacknut, 1/ 4 -20, Steel, #8LJN
16 X9190+ Label, Product at top, Axial Fan
17 72721B Switch Panel
18 X9048+ Switch rocker
19 X9262+ Circuit Breaker, 5A
20 X9188+ Screw, 6-32 x 3/8” Black MS
21 X8926+ 20’ HD, 3-wire Cord, 16/3 SJTW, 115 Volts
71912A Cord 14/3 35’ Black w/ Euro Plug.
22 PD8+ Strain Reliref, 1 /2” NPT
23 X8008N+ nut, Lock, 1/ 2” Steel Conduit
24 X9182-6+ Fan Blade Assembly
25 F631+ Round Belt
26 72470A Heat Shrink, Blk, 1/ 2” x 200’, Flexible Polyolefin
27 PD3B+ Foot, Black Rubber, Tall
Parts for PDF6WRD
©Powr-Flite, All Rights ReservedX9261 12.05
https://harrissupplyind.com-ToOrderPartsCall608-268-8080
This manual suits for next models
1
Other Powr-Flite Fan manuals
Popular Fan manuals by other brands

Scarlett
Scarlett SC-174 instruction manual

Create
Create WIND MINIMAL Assembly manual

Revel AIR
Revel AIR ALBANY Series instruction manual

Hinkley
Hinkley TIER 54 instruction manual

minkaAire
minkaAire SUNDOWNER F589-TCL Instruction manual warranty certificate

Monte Carlo Fan Company
Monte Carlo Fan Company 3SKYR56XXD Series Owner's guide and installation manual