Preen AFV-P-T620 Series User manual

AFV-P-T620 Series
620V Voltage Transform Unit for AFV-P Series
User Manual
AC Power Corp. (Preen)
V 1.4.EN
The information in this document is subject to change without notice.
Copyright by AC Power Corp. (Preen). All rights reserved.

Legal Notices
The information in this product manual is subject to change without notice.
AC Power Corp. makes no warranty of any kind with regard to this product manual,
including, but not limited to, the implied warranties of merchantability and fitness
for a particular purpose. AC Power Corp. shall not be held liable for errors contained
herein or direct, indirect, special, incidental or consequential damages in connection
with the furnishing, performance, or use of this material.
Copyright Notices. Copyright 2017 AC Power Corp. (Preen), all rights reserved.
Reproduction, adaptation, or translation of this document without prior written
permission is prohibited, except as allowed under the copyright laws.

Warranty
Preen’s AFV-P-T620 series 620V voltage transform unit is warranted against
defects in material and workmanship for a period of two year after date of shipment.
Preen agrees to repair or replace any assembly or component found to be defective,
under normal use during this period. Preen’s obligation under this warranty is
limited solely to repairing any such product which in sole Preen’s opinion proves to
be defective within the scope of the warranty when returned to the factory or to an
authorized service center. Transportation to the factory or service center is to be
prepaid by the purchaser. Shipment should not be made without prior authorization
by Preen.
This warranty does not apply to any products repaired or altered by persons not
authorized by Preen, or not in accordance with instructions furnished by Preen. If the
product is defective as a result of misuse, improper repair, or abnormal conditions or
operations, repairs will be billed at cost.
Preen assumes no responsibility for its product being used in a hazardous or
dangerous manner either alone or in conjunction with other equipment. High
voltage used in some products may be dangerous if misused. Special disclaimers
apply to these products. Preen assumes no liability for secondary charges or
consequential damages and in any event, Preen’s liability for breach of warranty
under any contract or other-wise, shall not exceed the purchase price of the specific
product shipped and against which a claim is made.
Any recommendations made by Preen for use of its products are based upon tests
believed to be reliable, but Preen makes no warranty of the results to be obtained.
This warranty is in lieu of all other warranties, expressed or implied, and no
representative or person is authorized to represent or assume for Preen any liability
in connection with the sale of our products other than set forth herein.
AC Power Corp. (Preen)
USA
192 Technology Dr., Suite S, Irvine, CA 92618
TEL +1 949-988-7799
Taipei
3F No. 200 Gangqian Road, Neihu Dist., Taipei 114, Taiwan
TEL +886 2-2627-1899 FAX +886 2-2627-1879

SAFETY SUMMARY
The following general safety precautions must be observed during all phases of
operation, service, and repair of this product. Failure to comply with these
precautions or specific WARNINGS given elsewhere in this manual will violate safety
standards of design, manufacture, and intended use of the product.
Preen assumes no liability for the customer‘s failure to comply with these
requirements, causing malfunction or damage on the product, personal injury, death
or any loss of, or damage to, property.
1) BEFORE APPLYING POWER
Verify that the product is set to match with the power line input.
Before relocating the product or reconnecting any cable, ensure the power line
input is cut off and the product has been shut down for 20 minutes.
2) PROTECTIVE GROUNDING
Make sure to connect the product to the protective ground to prevent an electric
shock before turning on the power.
3) NECESSITY OF PROTECTIVE GROUNDING
Never cut off the internal or external protective grounding wire, or disconnect the
wiring of protective grounding terminal. Doing so will cause a potential shock hazard
that may bring injury to a person.
.
4) OPERATING ENVIRONMENT
Do not operate the product in an area with poor ventilation.
Do not operate the product in the presence of flammable gases or fumes.
Do not block the cooling fan opening.
Do not push objects of any kind through the opening, or spill liquid of any kind
in the product.
5) DO NOT REMOVE THE COVER OF THE PRODUCT
Hazardous voltages may be present when covers are removed. Component
replacement and internal adjustment can be done only by qualified service personnel.

WARNING
LETHAL VOLTAGES. The product can supply 877V peak at its output. DEATH
on contact may result if either the output terminals or the circuits connected
to the output are touched when the power is applied.
In the event that there is fire occurring in the vicinity, please use dry powder
extinguishers. The use of liquid extinguishers may give rise to the danger of
electric shock.
NOTICE
Non-qualified personnel are not allowed to open cover, warranty void if warranty
sticker removed or damaged.

AFV-P-T620 Series 620V Voltage Transform Unit
Introduction
AFV-P-T620 Series is a 620V voltage transform unit, used with AFV-P series
programmable AC Power Source to increase the maximum output voltage range
from 0~310VAC to 0~620VAC, providing the users more extensive application range.
Specification
AFV-P-T620 Model
AFV-P-T620A
AFV-P-T620B
AFV-P-T620C
AFV-P Model
AFV-P-600
AFV-P-1250
AFV-P-2500
AFV-P-5000
Power(VA)
600VA
1250VA
2500VA
5000VA
AC Output
Phase
Single
Voltage Range
0~620.0V
Voltage Resolution
0.1V
Frequency Range
AFV-P B model: 45~500Hz;AFV-P A model: 45~1000Hz
Frequency Resolution
0.1Hz at <100Hz;1Hz at ≧100Hz
Frequency Stability
≦0.01%
Max. Current (RMS)
1.25A
2.5A
5A
10A
Max. Current (Peak)
5A
10A
20A
40A
Power(W)
500W
1000W
2000W
4000W
Line Regulation
≦±0.5V
Load Regulation
≦±0.5V (Resistive Load)
Total Harmonic
Distortion(THD)
≦0.3% at ≦100Hz;0.5% at 101~500Hz;1% at ≧501Hz (Resistive Load)
Response Time
≦300us
Form Factor
2.4 : 1 (at 50/60Hz)
Measurement
Frequency Range
45~1000Hz
Frequency Resolution
0.1Hz
Frequency Accuracy
±0.1Hz at ≦500Hz;±0.2Hz at >500Hz
Voltage Range
0~620.0V
Voltage Resolution
0.1V
Voltage Accuracy
±(0.5% of reading + 5 Counts)
Current Range
Hi:0.50~6.00A
Lo:0.005~0.600A
Hi:1.00~12.00A
Lo:0.005~1.200A
Hi:0.05~24.00A
Current Resolution
Hi:0.01A
Lo:0.001A
Hi:0.01A

AFV-P-T620 Series 620V Voltage Transform Unit
Current Accuracy
±(2% of reading + 5 Counts) at ≦500Hz
±(2% of reading + 10 Counts) at >500Hz
Peak Current Range
0.0~22.5A
0.0~45.0A
0.0~90.0A
Peak Current Resolution
0.1A
Peak Current Accuracy
±(2% of reading + 5 Counts) at ≦500Hz;
±(2% of reading + 10 Counts) at >500Hz
Power Range
Hi:100~1200W
Lo:0.0~120.0W
Hi:200~2400W
Lo:0.0~240.0W
Hi:0~4800W
Power Resolution
Hi:1W
Lo:0.1W
Hi:1W
Power Accuracy
±(2% of reading + 10 Counts) at ≦500Hz;
±(2% of reading + 15 Counts) at >500Hz
Environment
Operating Temperature
0℃~40℃
Humidity
0~90% (Non-condensing)
Dimension
88 * 442 * 495mm
88 * 442 * 650mm
Weight
14kg
25kg
35kg

AFV-P-T620 Series 620V Voltage Transform Unit
Installation
AFV-P-T620 can only be used with the AFV-P series. Turn the AFV-P series off before
installation. The power cord used must be rated at least 85℃and has sufficiently
gauge, so they will not overheat while carrying the output current. The input power
line must have a current rating which is greater than or equal to the maximum rated
current of the product.
Figure 1
Referring to Figure 1, perform the following steps:
1. Remove the safety covers of the input and output terminal from the rear
panel of AFV-P-T620.
2. Connect the input terminals of AFV-P-T620 to the output terminals of AFV-P.
The terminals SL, L, , N, SN must be connected correspondingly.
3. Fasten the power cords with strap.
4. Connect the load to the N and L of the output terminals of AFV-P-T620, and
ensure to connect to the ground.
5. Screw the safety covers back to the input and output terminals.

AFV-P-T620 Series 620V Voltage Transform Unit
Setup/Operation
After installation, ensure AFV-P’s input is well connected. Turn on AFV-P and perform
the following steps on its touch screen to setup.
1. After the power on procedure, press MENU at the main page (see Figure 2).
Figure 2
2. Press SETTING (see Figure 3).
Figure 3

AFV-P-T620 Series 620V Voltage Transform Unit
3. Press SYSTEM, and press the icon to move to the last page of the SYSTEM
subpage (see Figure 4).
Figure 4
4. Switch the icon status of AC-620V from OFF to ON (see Figure 5).
Figure 5

AFV-P-T620 Series 620V Voltage Transform Unit
5. Press the icon to return to the main page, the output voltage can now be
set from 0 to 620 (see Figure 6).
Figure 6
NOTICE
While AC-620Vitem is set ON, the VOLTAGE SENSE (go to MENUSETTING
TESTING) will automatically change from INT to EXT.
However, when AC-620V item is switched from ON to OFF, the item of VOLTAGE
SENSE will still remain EXT. So if the users would like to use AFV-P series alone
without AFV-P-T620 and remote sense function, VOLTAGE SENSE has to be
switched from EXT to INT; otherwise the protection warning will be triggered.