Promise Vess A2000 Series Operation manual

Vess A2000 Series
IO Terminal Board
User Information
Version 1.0
© 2014 PROMISE Technology, Inc. All Rights Reserved.

Contents
IntroduCtIon 1
I/O TermInal BOard FeaTures 2
PIn assIgnmenTs 3
SenSor Input ConneCtor 3
AlArm output ConneCtor 4
HOw TO use THe I/O recePTacle 5
OPeraTIOn examPles 6
SenSor Input ConneCtIon 6
CheCk SenSor Input StAtuS In ClI7
AlArm output ConneCtIon 8
enAble SenSor output In ClI 9
DISAble AlArm DevICe 10
ConneCtIng An AnAlog CAmerAS wIth rS-232/422/485 portS 11
ConfIgure ConneCtIon In ClI 12
FaQ 14

IntroductIon
This document answers questions that PROMISE customers might have concerning the function
of the I/O terminal board available as an option on the Vess A2000 NVR Storage Appliance models.
Vess A2200 rear panel
Vess A2600 rear panel
1
IO Terminal Board User Information

I/O Terminal Board Features
• Supports 8 input sensors, 8 output alarms and a RS-422/485 interface.
• SensorInputConnector: Connect sensor input lines. An external device issues a warning to
the I/O terminal board controller.
• AlarmOutputConnector:Connectalarmoutputlines.Usedtosendpre-denedalarm
signals.
I/O terminal interface
2
Vess A2000 NVR Storage Appliance Promise Technologies

Pin Assignments
Sensor Input Connector
1 3.3V
2 IN_8 -
3 IN_8 +
4 IN_7 -
5 IN_7 +
6 IN_6 -
7 IN_6 +
8 IN_5 -
9 IN_5 +
10 IN_4 -
11 IN_4 +
12 IN_3 -
13 IN_3 +
14 IN_2 -
15 IN_2 +
16 IN_1 -
17 IN_1 +
18 GND
Pin Number SENSOR IN
3
IO Terminal Board User Information

Alarm Output Connector
1 GND
2 OUT_8 -
3 OUT _8 +
4 OUT _7 -
5 OUT _7 +
6 OUT _6 -
7 OUT _6 +
8 OUT _5 -
9 OUT _5 +
10 OUT _4 -
11 OUT _4 +
12 OUT _3 -
13 OUT _3 +
14 OUT _2 -
15 OUT _2 +
16 OUT _1 -
17 OUT _1 +
18 GND
19 RS-422/485 TX -
20 RS-422/485 TX +
21 RS-422 RX -
22 RS-422 RX +
Pin Number ALARM OUT
4
Vess A2000 NVR Storage Appliance Promise Technologies

How to use the I/O Receptacle
Insert a small at-head screwdriver into the slot above the hole you want to connect. Hold the
screwdriver in place and insert the wire, then release the screwdriver. See illustration below.
5
IO Terminal Board User Information

Operation Examples
Below are examples of how to connect and check the status for devices used with the I/O terminal
board.
Sensor Input Connection
The illustration below is used as an example. In this example a motion sensing camera is connected.
• Connect the SENSOR_IN + on the Vess I/O terminal interface with an external camera
Alarm Out + (Red wire in illustration)
• Connect the SENSOR_IN - on the Vess I/O terminal interface with an external camera
Alarm Out - (Black wire in illustration)
See “Sensor Input Connector” on page 3 for pin assignments.
6
Vess A2000 NVR Storage Appliance Promise Technologies

Check Sensor Input Status in CLI
To check the status for the device that issues a warning to the terminal board. Follow these steps:
1. OpentheCLIinterface,type<enclosure –v>thesensorstatusdisplays.
2. TheSensorStatusdisplayedisdependantontheinputpairthatisusedontheSensorInput
interface. For example, the Input 4 pair (IN_4+and IN_4-)displaysSensor Status 247.
Use the value to calculate which pair is connected to a camera or alarm. Use the tables on pages
14 and 15 in “FAQ”.
7
IO Terminal Board User Information

Alarm Output Connection
The illustration below is used as an example. The example used is an alarm.
• Connect the ALARM_OUT + on the I/O terminal interface to the 3.3V or 5V connection on the
external alarm device (Blue wire in illustration)
• Connect the ALARM_OUT - on the I/O terminal interface to the Input + connection on the
external alarm device (Red wire in illustration)
• Connect the ALARM_GND - on the I/O terminal interface to the Input - connection on the
external alarm device (Black wire in illustration)
See “Alarm Output Connector” on page 4 for pin assignments.
8
Vess A2000 NVR Storage Appliance Promise Technologies

Enable sensor output in CLI
Toenablethealarmconnectedtothe sensordevice,thatis,toenable theabilityoftheterminal
board send a signal to the alarm when the sensor device is triggered, follow these steps:
1. OpentheCLIinterface,type
<enclosure –a mod –s “alarmstatus=1”>
2. TochecktheAlarmStatus,type<enclosure -v>
Change the Alarm Status to enable or disable the connected external alarm device.
See “FAQ” on page 14 for more information.
9
IO Terminal Board User Information

Disable Alarm Device
To disable the alarm device:
1. OpenCLIandtype<enclosure –a mod –s “alarmstatus=0”>
2. Type<enclosure –v>anditwilldisplaysthealarmstatus.
10
Vess A2000 NVR Storage Appliance Promise Technologies

Connecting an Analog Cameras with RS-232/422/485 ports
These are important points to keep in mind when using or connecting and using analog cameras.
• Onlyoneconnectorcanbeusedatonetime:RS-232C, RS-422, or RS-485
• For pan, tiltand zoomoperations, connect a camera control cable to RS-232 connector or the
RS-422/485 connector (four rightmost pins on the alarm output connector).
• RS-232Port1:Thisisusedforcontrollineconnectiontoanuninterruptiblepowersupply
(UPS).
• RS-232Port2: Use this to connect to analog cameras via the analog camera input cable.
Note: This connector cannot be used at the same time as the RS-422/485 connector.
• RS-422/RS-485 : Use this to connect to analog cameras via the analog camera input cable.
Note: This connector cannot be used at the same time as the RS-232 connector.
11
IO Terminal Board User Information

Congure connection in CLI
Congure RS-232 (Port 2)
Choosing this option enables the RS-232 port and disables the RS-422/485 port on the terminal
board.
1. OpenCLIandtype<enclosure –a mod –s “uartstaus=0”>
2. Type<enclosure –v>anditwilldisplaystheUartStatus.
Congure RS-422/485 (I/O Terminal Board)
Choosing this option enables the RS-422/485 port on the terminal board and disables the RS-232
port.
1. OpenCLIandtype<enclosure –a mod –s “uartstatus=1”>
2. Type<enclosure –v> anditwilldisplaystheUartStatus.
12
Vess A2000 NVR Storage Appliance Promise Technologies

Illustrated Connecon -Vess A2200
Illustrated Connecon - Vess A2600
13
IO Terminal Board User Information

FAQ
Q1:HowcanIknowwhichdevicehasaninputsignal(SensorStatus=Enable)toI/Oterminal
boardcontrollerfromsensorstatusinCLI?
A: Use this table to determine which camera is sending the warning (Sensor Status=Enable).
Note that when the Sensor Status in the CLI is “0”, indicates signal input on all SENSOR IN; a
Sensor Status of “1” indicates SENSOR IN 2, 3, 4, 5, 6, 7 and 8 have signal input; SENSOR IN 1 (20)
has no signal input.
Example#1
Sensor Status is “72” in CLI.
• 26plus 23equals 72=> SENSOR IN_7 and SENSOR IN_4 have no input signal
(i.e. Sensor Status = Disable).
• All other SENSOR IN (1, 2, 3, 5, 6, 8) have input signals. (i.e. Sensor Status = Enable).
Example#2
Sensor status is “255” in CLI .
- All SENSOR IN (1, 2, 3, 4, 5, 6, 7, 8) have no input signals. (i.e. Sensor Status = Disable).
PinNo. SENSORIN
SensorStatus
Enable Disable
2 IN_8 - 0 27
3 IN_8 +
4 IN_7 - 0 26
5 IN_7 +
6 IN_6 - 0 25
7 IN_6 +
8 IN_5 - 0 24
9 IN_5 +
10 IN_4 - 0 23
11 IN_4 +
12 IN_3 - 0 22
13 IN_3 +
14 IN_2 - 0 21
15 IN_2 +
16 IN_1 - 0 20
17 IN_1 +
14
Vess A2000 NVR Storage Appliance Promise Technologies

Q2:How canI knowwhich externalalarm issuesa warning(Alarm Status= Enable)from
alarmstatusinCLI?
A:Usethistablethatyoucancalculatewhichexternalalarmiswarning(AlarmStatus=Enable).
Note that when the Alarm Status in the CLI is “0”, indicates warning on all ALARM_OUT; an Alarm
Status of “1” indicates ALARM_OUT 2, 3, 4, 5, 6, 7 and 8 have signal input; ALARM_OUT (20) has no
warning.
Example#1
Alarm Status is “129” in CLI.
• 27plus 20equals 129 => ALARM_OUT._8 and ALARM_OUT_1 have no warning
Example#2
Alarm status is “255” in CLI .
• No warning (signal output) on all alarms.
PinNo. ALARMOUT
AlarmStatus
Enable Disable
2 OUT_8 - 0 27
3 OUT_8 +
4 OUT_7 - 0 26
5 OUT_7 +
6 OUT_6 - 0 25
7 OUT_6 +
8 OUT_5 - 0 24
9 OUT_5 +
10 OUT_4 - 0 23
11 OUT_4 +
12 OUT_3 - 0 22
13 OUT_3 +
14 OUT_2 - 0 21
15 OUT_2 +
16 OUT_1 - 0 20
17 OUT_1 +
15
IO Terminal Board User Information

Table of contents
Popular I/O System manuals by other brands

Allen-Bradley
Allen-Bradley FLEX I/O 1794-IG16 installation instructions

Curtis Instruments
Curtis Instruments 1351 manual

MG
MG DLC E2 Series instruction manual

Automationdirect.com
Automationdirect.com Stride SIO-MB08THMS manual

ICP DAS USA
ICP DAS USA ET-2242 user manual

Johnson Controls
Johnson Controls FX-PCX2721 installation instructions