PS Audio PowerPlay Owner's manual

15‐052‐99‐1‐DOM‐A Page1of6
PowerPlayProgrammingManual
HTTPcommandprotocols
ConnectaCat5/6cabletotheEthernetportonthebackpanelofthePowerPlaytoanetworkport.The
PowerPlaycancommunicatewithacomputerconnectedtotheinternet,ortothePSAudioGlobalnet
Server.
HTTPcommandsareenteredinthefollowingsyntax:
http://HOSTNAME/commands.cgi?command=XX=YYYwheretheXX=YYYportionisasdescribedinthe
tablesbelow.Thesecommandinputcharactersmustbeuppercase.HOSTNAMEcanbethehostname
ofthePowerPlay(readablefromthefrontpaneldisplay,ornetworkinterface),ortheIPaddress(also
readablefromthefrontpaneldisplay,ornetworkinterface).
Ifthereisacommandinputerror,dependingonthetypeoferror,thePowerPlaywillrespondwith
either&data=OK,or&data=ERROR.
Serialcommandprotocols
ConnectaterminalorcomputerdirectlytothefemaleDB9RS232connectoronthePowerPlay
backpanelfordirectserialcommunication.Portsetupparameters:
•Baudrate19200
•No.ofdatabits8
•No.ofstopbits1
•Parity none
•Flowcontrolnone
Serialcommandsareenteredinthefollowingsyntax:
XX=YYY\n\rwhereXX=YYYisasdescribedinthetablesbelow.The\n\rcommandterminatorsarenew
lineandcarriagereturn.
Ifthereisacommandinputerror,dependingonthetypeoferror,thePowerPlaywillrespondwith
either&data=OK,or&data=ERROR

15‐052‐99‐1‐DOM‐A Page2of6
Table1:UnitCommands
CommandActionSyntaxPowerPlayResponse
UnitPower
MasterPowerOFFUP=OFF&data=OK
MasterPowerONUP=ON&data=OK
RebootMasterPowerUP=REBOOT
MasterPowerStatusUP=?&data=xxx(ONorOFF)
UnitNameSetUnitNameUN=xxx(upto16char)&data=OK
RequestUnitNameUN=?&data=xxx(UnitName)
DisplayBrightness
SetdisplaytoBRIGHTUB=BRIGHT&data=OK
SetdisplaytoDIMUB=DIM&data=OK
SetdisplaytoOFFUB=OFF&data=OK
DisplaybrightnessstatusUB=?&data=xxx(BRIGHT,
DIM,OROFF)
OutputDelay
SetUnitoutputON/OFF
delay(seconds)
UD=x,y(upto
65536,65536)
&data=OK
ReturnoutputdelaysettingsUD=?&data=x,y(x=number
ofsecondsofdelay
beforeswitchingon.y=
numberofseconds
beforeswitchingoff
UnitLockout
TurnfrontpanellockoutOFFUL=OFF&data=OK
TurnfrontpanellockoutONUL=ON&data=OK
ReturnLockoutStatusUL=?&data=xxx(ONorOFF)
DHCP
TurnDHCPServerOffNS=OFF&data=OK
TurnDHCPServerOnNS=ON&data=OK
ReturnDHCPStatusNS=?&data=xxx(ONorOFF)
StatusRequests
ReturnPowerStatusofUnit
andZones
RSNote1
ReturnallInformationRANote2

15‐052‐99‐1‐DOM‐A Page3of6
Table2:ZoneCommands
CommandAction
Syntax
(x=zone
number1‐10)
PowerPlayResponse
ZonePower
TurnSpecifiedZoneOffZP=x,OFF&data=OK
TurnSpecifiedZoneOnZP=x,ON&data=OK
RebootSpecifiedZoneZP=x,REBOOT&data=OK
ReturnSpecifiedZonePowerStatusZP=x,?&data=yyy(ONorOFF)
ZoneName
SetspecifiedZoneNameZN=x,y(upto
16chars)
&data=OK
ReturnSpecifiedZoneNameZN=x,?&data=yyy(ZoneName
Characters)
ZoneDelay
SetSpecifiedZoneDelaytoAlwaysOnZD=x,ON&data=OK
SetSpecifiedZoneDelaytoSwitchedZD=x,SW&data=OK
SetSpecifiedZoneDelaytoDelayedZD=x,DLY&data=OK
SetSpecifiedZoneDelayto
Programmed
ZD=x,PGM&data=OK
SetSpecifiedZoneDelaytoRebootZD=x,RBT&data=OK
SetSpecifiedZoneDelaytoAuto‐
Reboot
ZD=x,ARB&data=OK
ReturnSpecifiedZoneDelayStatusZD=x,?&data=yyy
(ON,SW,DLY,PGM,RBT,
ORARB)
SetSpecifiedZoneDelayTime
(seconds)
ZT=x,y,z(upto
65536,65536)
&data=OK
ReturnSpecifiedZoneDelayTimeZT=x,?&data=y,z(y=number
ofsecondsofdelay
beforeswitchingon.z=
numberofseconds
beforeswitchingoff
ZonePriority
SetSpecifiedZonePriorityLeveltoLowZL=x,LOW&data=OK
SetSpecifiedZonePriorityLevelto
Normal
ZL=x,NORMAL&data=OK
SetSpecifiedZonePriorityLevelto
Critical
ZL=x,CRITICAL&data=OK
ReturnSpecifiedZonePriorityLevelZL=x,?&data=yyy(LOW,
NORMAL,orCRITICAL)

15‐052‐99‐1‐DOM‐A Page4of6
Table3.Externalinterfacecommands
CommandActionSyntaxPowerPlayResponse
InfraredControl
StoreIRCodeIS=x(IRCodeString)&data=OK
GetIRCodeIG=x(Codenumber(1‐16))&data=x(IRCode
String)
DeleteIRCodeID=x(Codenumber(1‐16))&data=OK
SendIRCodeIF=x(Codenumber(1‐16))&data=OK
ReturnIRCode
information
RI&irxname=YY.See
note3.
PhoneControl
SetPhoneControl
Password
PP=x(4digits)&data=OK
ReturnPhone
ControlPassword
PP=?&data=(4digits)
Note1.PowerPlayResponsetotheRScommand:
Example
&upwr=1&umov=1&zpwr=1111111111&volts=122&watts=10&thd=3.3&temp=nosensor&ups=notfound
Response RangeofResponse
UnitPowerStatus&upwr=0ifoff,1ifon
OverVoltageMetalOxide
Varistor(MOV)Protection
Status
&umov=0ifnoMOVprotection,1ifMOVsareok
ZonePowerStatus&zpwr=Foreachzone,0ifoff,1ifon
OutputVoltage&volts=Sameastheoutputvoltagedisplayedonthe
frontpanel
OutputPower&watts=Sameastheoutputpowerdisplayedonthe
frontpanel
OutputHarmonicDistortion&thd=Sameastheharmonicdistortionreading
displayedonthefrontpanel
Temperature&temp=Iftheoptionaltemperaturesensorisinstalled,
thisisthesamevaluethatisdisplayedonthe
frontpanelfortemperature.Otherwise
‘nosensor’
UPS&ups=notfound,online,battery,critical,orloop

15‐052‐99‐1‐DOM‐A Page5of6
Note2.PowerPlayresponsetotheRAcommand.
Example:
&upwr=1&uname=Unit_1&utdon=0&utdoff=0&ulock=0&umov=1&ub=2&ptype=ci&mtype=9000&mvolt
s=120&z1pwr=1&z1name=Preamp&z1dlymode=ON&z1tondly=3&z1toffdly=3&z1priority=1&z2pwr=1&z
2name=DLY&z2dlymode=ON&z2tondly=3&z2toffdly=3&z2priority=1&z3pwr=1&z3name=ZONE3&z3dly
mode=SW&z3tondly=3&z3toffdly=3&z3priority=1&z4pwr=1&z4name=ZONE4&z4dlymode=SW&z4tondl
y=3&z4toffdly=3&z4priority=1&z5pwr=1&z5name=ZONE5&z5dlymode=SW&z5tondly=3&z5toffdly=3&z
5priority=1&z6pwr=1&z6name=ZONE6&z6dlymode=SW&z6tondly=3&z6toffdly=3&z6priority=1&z7pwr=
1&z7name=ZONE7&z7dlymode=SW&z7tondly=3&z7toffdly=3&z7priority=1&z8pwr=1&z8name=ZONE8
&z8dlymode=SW&z8tondly=3&z8toffdly=3&z8priority=1&z9pwr=1&z9name=ZONE9&z9dlymode=SW&z
9tondly=3&z9toffdly=3&z9priority=1&z10pwr=1&z10name=ZONE10&z10dlymode=SW&z10tondly=3&z
10toffdly=3&z10priority=1&volts=123&watts=11&thd=3.3&temp=nosensor&ups=notfound&dhcps=1&d
hcp=1&mac=001FF6000081&ip=192.168.249.51&mask=255.255.255.0&gateway=192.168.249.1&pdns=
192.168.249.204&sdns=192.168.249.206&hostname=PowerPlay1&fwvproc=2.01&fwvboot=1.05&fwvw
eb=1.11&fwvtel=1.01&fwvtelwav=1.04
RAResponse RangeofResponse
UnitPowerStatus&upwr=0ifoff,1ifon
UnitName&uname=Upto16alphanumericcharacters
UnitTimeDelayOn&utdon=0to65536
UnitTimeDelayOff&utdoff=0to65536
FrontPanellocked&ulock=0ifnotlocked.1iflocked
OverVoltageMetalOxide
Varistor(MOV)Protection
Status
&umov=0ifnoMOVprotection,1ifMOVsareok
DisplayBrightness&ub=0ifoff,1ifdim,2ifbright
ProductType&ptype=ciorav
ModelNumber&mtype=8000or9000
ProductVoltage&mvolts=Nominaldesignvoltage=100,120,or230
ZonePowerStatus&z(1‐10)pwr=Foreachzone,0ifoff,1ifon
ZoneName&z(1‐10)name=Upto16alphanumericcharacters
ZoneDelayMode&z(1‐10)dlymode=ONorOFF
ZoneOnDelayTime&z(1‐10)ondly=0to65536
ZoneOffDelayTime&z(1‐10)offdly=0to65536
ZonePriority&z(1‐10)priority=0=Low,1=Normal,2=Critical
OutputVoltage&volts=Sameasthereadingonthefrontpaneldisplay

15‐052‐99‐1‐DOM‐A Page6of6
OutputPower&watts=Sameasthereadingonthefrontpaneldisplay
OutputHarmonicDistortion&thd=Sameasthereadingonthefrontpaneldisplay
Temperature&temp=Sameasthereadingonthefrontpaneldisplayif
optionaltempsensorisinstalled.Otherwise
’nosensor’
UPSStatus&ups=notfound,online,battery,critical,orloop
DHCPServerEnable&dhcps=0=disabled,1=enabled
DHCPEnable&dhcp=0=disabled,1=enabled
MACAddress&mac=MACaddressofunit
IPAddress&ip=IPaddressofunit
SubnetMask&mask=Maskaddressofunit
GatewayAddress&gateway=AddressofGateway
PrimaryDNSserver&pdns=IPAddressofPrimaryDNSserver
SecondaryDNSserver&sdns=IPAddressofSecondaryDNSserver
Hostname&hostname=Upto16alphanumericcharacters
ProcessorFirmwareVersion&fwvproc=Versionnumberofmaincontrolsoftware
BootloaderFirmware
Version
&fwvboot=Versionnumberofbootloadersoftware
WebFirmwareVersion&fwvweb=VersionnumberofWebinterfacesoftware
TelephonecontrolFirmware
Version
&fwvtel=Versionnumberofphonecontrolsoftware
Telephonecontrol.wavfile
Fimware
&fwvtelwav=Versionnumberoftelephoneaudiofilesoftware
Note3.PowerPlayresponsetotheRIcommand
Example
&ir1name=TVPower&ir1event=PWRON&ir1wait=1&ir2name=TVCh
&ir2event=PWRON&ir2wait=1&ir3name=Mute&ir3event=PWRON&ir3wait=1&ir4name=Volup
&ir4event=PWRON&ir4wait=1&ir5name=Voldn&ir5event=PWRON&ir5wait=1&ir6name=VCRPower
&ir6event=PWRON&ir6wait=1&ir7name=EMPTY&ir8name=EMPTY&ir9name=EMPTY&ir10name=EMPTY
&ir11name=EMPTY&ir12name=EMPTY&ir13name=EMPTY&ir14name=EMPTY&ir15name=EMPTY&ir16n
ame=EMPTY&freeslots=10
Popular Software manuals by other brands

Red Hat
Red Hat ENTERPRISE LINUX 4 - FOR X86-ITANIUM AND... installation guide

Avaya
Avaya OAISYS NetSuite 4.2 Application notes

Asante
Asante SmartBridge V1.0 user manual

Xerox
Xerox Wide Format 6204 installation guide

SAS
SAS Scalable Performance Data Server 4.5 Administrator's guide

Lucid
Lucid FM2A85X Extreme6 installation guide

Juniper
Juniper JUNOS PUS MOBILE SECURITY SUITE datasheet

GRASS VALLEY
GRASS VALLEY NETCONFIG V2.0.12 instruction manual

Epson
Epson Stylus Pro 9880 ColorBurst Edition - Stylus Pro 9880... Getting started

COMPRO
COMPRO COMPROFM manual

Muratec
Muratec OFFICEBRIDGE ONLINE user guide

Oracle
Oracle Contact Center Anywhere 8.1 installation guide