PureMate PM 718 User manual

PureMat TM
ULTRASONIC COOL MIST HUMIDIFIER
INSTRUCTION MANUAL
SUPER TECH HEALTH ©2015, PM718
PureMat TM

PureMateTM 2PM718
Thank you for purchasing the innovative PureMate PM 718 Cool Mist ultrasonic humidifier. We wish you many years of healthy indoor
air with this efficient and effective product.
Ensure that all safety precautions are followed when using this electrical appliance for the proper operation of the device. These
instructions describe the safety precautions to be observed during operation. They are designed to prevent injuries or damage to this
device.
SAFETY PRECAUTIONS
The inner ultrasonic transducer is highly sensitive. Do not touch it with bare fingers or scrape it with metal tools, or it will reduce mist
output. When cleaning this area please use a small cleaning brush, cotton swab or toothbrush. Do not use hot water as it may damage
the missing parts.
Use proper voltage AC 220~240V 50Hz in UK and Europe. Use of improper voltage may cause fire hazard or electric shock.
To prevent electric shock, do not dismantle, repair or modify this product. Maintenance and cleaning should be followed exactly as
instructed in this manual. In the event of a malfunction, please contact an authorized PureMate maintenance center.
Do not use in areas where flammable or explosive materials are stored.
Do not place this device in direct sunlight or near objects that generate high temperature heat. The heat may cause deformation or
warping of the outer casing. Do not operate the unit without water in the basin.
Do not insert foreign objects into the device. Do not touch the transducer or the lower water basin when the unit is operating. Do not
scratch the transducer. Do not touch the mist output when producing warm mist.
Do not submerge this device in water. Water or cleaning liquids may only be used on parts to be cleaned according to the cleaning and
maintenance instructions.
Only use lime scale remover or vinegar to clean mineral deposits from the basin or transducer. Do not use any harsh detergents that
may damage the unit.
If you smell an abnormal odour please turn off and unplug the unit and call PureMate technical support.
Do not use fabrics or other materials to cover this device. Obstructed air inlets and outlets will result in improper operation of this unit
and may result in fire or other damage.
Do not plug in or pull out the power cable with wet hands. Do not disassemble the base unit. Before cleaning and maintenance, the
appliance must be disconnected from the main supply. Do not touch water and components in the water basin when the unit is working.
Children should be supervised to ensure that they do not play with the appliance.
To prevent interference and damage to other electronic devices, this machine should be placed at least 1 meter away from a computer,
television, radio or other electronic equipment.
For safety reasons and to prevent fire or electric shock, unplug the power cord from the electric outlet socket whenever you:
oDo not use the device for a long period of time.
oRemove the tank, clean or service the machine or the permanent filter.
oMove or transport the device.
If the power cord is damaged, then it must be replaced by a qualified person to prevent electric shock or fire.

PureMateTM 3PM718
COMPONENTS
Description
1) On/Off illumination button
2) On/Off knob (OFF/ON)/ mist release intensity control
3) Illumination
4) Front panel
5) Lid with a mist release opening
6) Water tank
7) Water inlet
8) Filter-cartridge
9) Water tank lid
10) Sprayer
11) Humidifier body
12) On/no water indication

PureMateTM 4PM718
OPERATING INSTRUCTIONS
Before the First Use
oUnpack the unit and remove package materials. Examine the humidifier for damages. Do not switch on the humidifier in case of
damages.
Note:
oIf the unit was exposed to negative temperatures, keep it at room temperature for 30 minutes before switching it on for the first
time.
oUse the unit at the room temperature from +5° Сto +40° С, and relative humidity less than 80%.
oTake the water tank out of the unit, remove the water tank cover, and fill the tank with clear water not over 40oC then put back the
cover.
oCheck the water basin and make sure it is clean, then put the tank onto the base unit carefully.
oConnect the power plug and switch on the unit (NEVER RUN THE UNIT WHEN THERE IS NO WATER IN WATER BASIN), the
main connection lamp will be on. The unit starts working.
oBefore switching on the humidifier make sure that the voltage of electric network corresponds to the unit operating voltage.
Usage of the unit:
1) Remove the lid (5) from the water tank (6).
2) Remove the water tank (6) from the unit body.
3) Turn over the tank (6), open the lid (9) rotating it counter clockwise.
4) Fill the tank (6) with necessary amount of water, close the lid (9) rotating it clockwise.
5) Place the filled water tank (6) on the unit body.
6) Insert the plug into the socket.
7) Switch on the humidifier, turning the knob (2) clockwise, the operation indicator (12) will become blue.
8) Set the mist release intensity turning the knob(2).
9) You can switch on the illumination (3) by pressing the button (1), for example, at night- time.
10) If the water tank (6) is empty, the indicator(12) will become red.
11) In this case switch off the unit by setting the knob (2) to <<OFF>> position, the indicator (12) will go out, and then unplug the
unit. Fill the tank (6) with water, install it to its place and switch on the unit.
12) After the humidifier finishes operation, switch it off by setting the knob (2) to <<OFF>> position, the indicator (12) will go out.

PureMateTM 5PM718
CLEANING AND MAINTENANCE
Attention! Always switch off and unplug the unit before cleaning.
You can ensure many years of trouble free operation of your PM 718 humidifier by following a few simple maintenance procedures. If
your water is hard, containing high concentrations of calcium and other minerals, then over a period of time white dust will start to
deposit on the various surfaces in the room. A white, film-like substance will also start to develop in the water basin, on the transducer
and on the inner surface of the water tank. This white film will impede the proper function of the transducer and the operation of the
machine.
We recommend the following:
1. If your water is very hard, we recommend that you boil it first, allow it to cool completely before use in the humidifier. The boiling
will reduce the mineral concentration in the water. The other option is to use distilled water if your mineral level is still too high.
2. If you are using the machine on a daily basis, clean the transducer, water tank and basin once a week.
3. When the water tank needs a refill, empty the remaining water from the tank and fill it with fresh water.
4. Clean the whole machine and make sure to keep all the parts completely dry when the machine is not in use.
How to clean the transducer:
1. Place 5-10 drops of vinegar on the surface of the transducer and wait for 2-5 minutes.
2. Using a small brush, cotton swab or toothbrush, gently clean the mineral film from the surface of the transducer.
3. Rinse the transducer with clean water.
4. Never use sharp or solid objects for cleaning the transducer.
How to clean the water basin:
1. Clean the water with a soft damp cloth. If there is excess film on the surfaces, then soak the cloth with vinegar and repeat the
process.
2. If there is a film in any of the depressions along the basin, drop a bit of vinegar into depression and clean it out with a brush.
3. Rinse the basin with clean water.
How to clean the White Dust & Anti-Microbial Filter:
1. Remove the filter from the water tank.
2. Put some white vinegar into a glass. Soak the filter in the vinegar for about 10 minutes.
3. Remove the filter from the glass and shake it several times.
4. Clean and rinse the filter once again with fresh water.
If you don’t plan to use the humidifier for a long time, remove the filter from the water tank and let it dry thoroughly. Then wrap it in
protective packaging and keep it next to the humidifier in a cool, dry and dark storage space.
STORAGE
oIf you are not going to use the humidifier for a long time, make sure that all its parts are dry, including the operating chamber of the
sprayer.
oDo not store the unit with water in the water tank and in the operating chamber of the sprayer.
oClean and dry the filter-cartridge before taking it away for storage. Keep the filter-cartridge in a cool darkened place
oKeep the humidifier away from children in a dry cool place.

PureMateTM 6PM718
TROUBLESHOOTING
The following is a troubling shooting guide to help you solve any issues that may have with the operation of the Ultrasonic
Humidifier PM 718.
Trouble
Possible reasons
Solution
The operation indicator doesn’t light
up, does not work, no mist release
No voltage, no power supply
Connect power supply, switch on
Plug another, certainly operating appliance to the
socket to make sure that the socket works properly.
The operation indicator
flashes red, no mist release
Water tank is empty
Fill the water tank with water
Mist smells unpleasantly
First use of the unit
Remove the water tank lid, pour out water and leave
the tank open for 12 hours in a cool darkened place
Dirty or stagnant
water
Unplug the unit, remove the water tank, pour out the
water, wash the tank and fill it with clean boiled or
distilled water
Low mist release intensity
Sprayer is dirty
Unplug the unit and clean the sprayer.
Abnormal noise is heard
during the operation of the humidifier
The unit is placed on an uneven or
unstable surface.
Unplug the unit and level the unit body or set in
another place.
Mist coming out from around nozzle
There are apertures between the
nozzle and water tank
Dip the nozzle in water for a while and then fix it to
the socket on water tank
TROUBLESHOOTING
The following is not considered faulty operation:
oIf your water is very hard (containing abnormally high levels of minerals) the humidifier may produce white dust. This is not a
malfunction. The solution would be to clean the filter more often or use softer water.
oIf you stand very close to the humidifier, you will hear the gurgling sound of water. This is normal.
oThe machine operates very quietly but it is not completely silent. Noise levels less than 35 db is considered normal.
Warning!
If the above recommended solutions do not work, please contact PureMate technical support at the telephone number for your region.
Do not attempt to disassemble, repair and reassemble the machine as it may void the warranty.

PureMateTM 7PM718
PRODUCT SPECIFICATION
Model: PM 718
Power supply: 220~240V 50 Hz
Energy Consumption: 30W (Cool Mist)
Water tank capacity: 3.5L
Mist Evaporation Rate: ≥250ml/hr
Room Coverage Area: 30 m² (320 ft²)
Noise level: ≤25dB(A)
Dimensions (LxWxH): 14 x 26 x 31 cm
Weight: 1.7 kg (3.74 lbs) dry
Warranty: 1 Year Warranty
Safety Certifications: CE, GS, Rohs.Reach
DISPOSAL OF THIS DEVICE
At the end of the product life cycle, you should not throw this machine into the normal household garbage but bring
the product to a collection point for the recycling of electrical and electronic equipment.

PureMateTM 8PM718
WARRANTY INFORMATION
PureMate products are subject to strict quality control before leaving the manufacturer. This allows our customers to benefit from
repairs, replacement of parts and even replacements for free.
The product has 1 years warranty from the date of purchase.
The warranty shall not apply:
To any product subjected to misuse, alteration, act of God, improper handling, improper transport, improper testing or
unauthorized repair.
To cosmetic problems or defects which result from normal wear and tear under ordinary use yet not affecting the
performance or use of the product.
If the product is disassembled or altered.
To any packing, transportation, export / import tax or any related expenses.
Regular replacement parts such as air filter cartridges and UV-C Lamp.
Customer must present the sales invoice or receipt for 1 years warranty services.
What You Must Do
1. Contact PureMate customer Service at:
+44 121 270 9423 www.PureMate.co.uk
For Return Authorization Number.
2. Pack the product in its original carton, and in the same manner in which you received it, or as identical as possible.
3. Include proof of purchase inside box along with the Return Authorization Number.
4 Label and ship the unit, freight pre-paid, to the address provided.
Other Conditions
The provisions of this warranty are in lieu of any other written warranty whether express or implied, written or oral, including any
warranty of merchantability or fitness for a particular purpose. The manufacturer‘s maximum liability shall not exceed the actual
purchase price paid by you for the product. In no event shall the manufacturer be liable for special, incidental, consequential, or
indirect damages. This warranty does not cover a defect that has resulted from improper or unreasonable use or maintenance, faulty
assembly, accident, natural catastrophes, improper packing, or unauthorized tampering, alteration, or modification as determined
solely by us. This warranty is void if the label bearing the serial number has been removed or defaced.
Table of contents