Qlightec SAMP-100 User manual

1
Product SpecicationsOrdering Specications
Precautions for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn o-• the power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product’s speci¿cation.
4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
5. Do not apply excessive force/impact to the product.
6. Failure to follow any of the instructions above may cause malfunction or damage to the product, ¿re, and electric shock.
Precautions for Correct Use
Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the
product that would void the warranty.
1. During wiring or maintenance, please completely turn o-• the power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
ratings indicated for each product. (Failure to follow these instructions may cause a ¿re to the product, electric shock, physical injury,
malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to
follow these instructions may lead to ¿re, electric shock, or product damage.)
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to ¿re, electric shock, or product damage.)
5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device. (Failure to
follow this may cause damage to property, ¿re, electric shock and loss of life.)
Thank you for purchasing Qlight’s products. Please read this user manual carefully
prior to installation and operation to ensure safe and correct use.
135
HORN
Controllable Amplier and Horn for QLV Light Bars
SAMP-100/ SM-100ND
SAMP-100 - 12
[Model number] [Voltage]
| |
• SAMP-100 • 12
-DC12V
• SM-100ND • 12
-DC12V
Model
number VoltageCurrent Sound
pattern Frequency/ Repeat
time Certi¿cateWeight
SAMP-100
DC12V
10A
FireAlarm
300~700Hz/140cycle
1.15kg
Emergency
350~750Hz/14cycle
Horn
600~91KHz
Buzzer
2.25Hz/90cycle
Model Voltage Volume Certi¿cateWeight
SM-100ND
DC12V
Max. 135dB 1.15kg
Please scan the QR code for more
detailed product information.
www.qlight.com

2
Dimensions
•
SAMP-100 control unit has a 7p connector and SAMP-100
power unit has a 5p connector.
•
Refer to the pin map on the right for wiring instructions.
•
For the power unit, please make sure to use a fuse to ensure
the product operates properly.
Wiring Instructions
(Units : mm)
2-Ø7 SLOT HOLES
2-Ø12 HOLES
165
185
123
175
178.2 110
25
118
63
2-M5 TAP
FITTING HOLES
50
R3.5
65
17
108
91
1
27.5
15
30
Ø122
Ø117
50
35
7
SAMP-100 SM-100ND
Power
Fuse
TACT
PATR
INTER
SPK(
-
)
TAKER
NIGHT
SPK
(+)
DC12V(IN)
NC
GND
DC12V(OUT)
GND SM-100ND
SAMP-100(POWER)
CONNECTOR-7P
SAMP-100(POWER)
CONNECTOR-5P
SAMP-100
Parts Denition/ Installation
• First, machine taps or holes on the mounting surface .
• The mounting hole of this product is 7mm(SAMP-100) and 12mm(SM-100ND) in diameter(long hole).
• Insert the bolt through the hole of the product, and tighten the nut from the opposite side of the mounting surface.
• Please fasten the nuts until the bolts are tightened securely.
• Use a at washer and spring washer in the bolt assembly if the product will experience severe vibration and shock.
100W UNIT
Housing
(STS,AL(AL)
Microphone
Bolt
SM-100NDSAMP-100
Bolt
Nut Nut
Bracket(Steel)

3
Product Functions
Number Functions Action
1TACTICAL
Strobe function for the entire warning light bar
Available in conjunction with
warning light bar
2PATROL
Strobe function starting from the middle and
radiating outwards continuously
3INTERVENTION
Strobe function radiating from left to right
continuously
4NIGHT
Light intensity reduced to 25-30% of normal
operation
5TAKE DOWN
All LED modules on
6HORN
Horn sound on
7WAIL
Wail emergency sound on (A-ANG)
8YELP
Yelp emergency sound on (WA-U)
9TOOL
Piercer emergency sound on (DI-DI-DI-DI)
10 H / L
High-low emergency sound on (PI-PO)
11 HOOK KEY
Button for voice announcement when pressed down.
12 TACT SWITCH
Strobe function 1(tactical) and yelp emergency sound on
①
⑤ ⑦ ⑨⑥ ⑧ ⑩
③② ④ ⑪ ⑫
Mounting Hole Specications
2-Ø8 SLOT HOLES2-Ø13 HOLES
18
123
110
•
Machine holes on the mounting surface referring to the diagram below.below.
SM-100NDSAMP-100

Head O-ce | Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea
Tel. +82-2-2679-6152(Toll free. +82-80-328-2222) Fax. +82-2-2679-6154
Factory | 185-25, Mukbang-ro, Sangdong-myeon, Gimhae-si, Gyeongsangnamdo, Korea Tel. +82-55-328-1111(Toll free. +82-80-328-1111)
Qlight OverSEAs Sales Dept |
704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel : +82-51-620-4100
Qlight Public Relations & Marketing Team O-ce | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel. +82-51-245-0017
3003 North First Street, Suite #341, San Jose, CA 95134 USA Tel. +1 - 408 - 519 - 5740 Fax. +1 - 408 - 519 - 5739
China Factory/ Shanghai Sales O-ce | #19, Nanda Road, Baoshan Area, Shanghai, China Tel. +86
-
21
-
6651
-
7100 Fax. +86
-
21
-
6315
-
3929
China Factory Site 2 (Qidong) | #33, Haiyan Road, Qidong High-tech Industrial Development Zone, Qidong, Jiangsu Province, China
Tel +86
-
513
-
8384
-
9999 Fax +86
-
513
-
8384
-
9910
Product Operation Inquiry / Customer Support +82-51-620-4100
You can expect prompt service if you have exact information such as model name, symptom, telephone number and address.
※ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Head office : Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea ( Postal Code : 08507)
Factory : 185-25, Mukbang-Ro, Sangdong-Myeon, Gimhae-Si, Gyeongsangnam-Do, Korea ( Postal Code : 50805)
For your safety
Speci¿cation and dimensions listed in this catalogue subject to change without notice for product quality improvement.
The newest product information is available on our website.(www.qlight.com)
Please read the instruction manual attached to the product carefully before installation and use.
www.qlight.com
EN - SAMP-100 - 2207A
This manual suits for next models
1
Table of contents