manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Radiant Solutions
  6. •
  7. Adapter
  8. •
  9. Radiant Solutions Therma-Cord TC-2000 User manual

Radiant Solutions Therma-Cord TC-2000 User manual

Popular Adapter manuals by other brands

Mini Gadgets BB2Outlet user manual

Mini Gadgets

Mini Gadgets BB2Outlet user manual

LSI LSISAS3442E-R Quick installation guide

LSI

LSI LSISAS3442E-R Quick installation guide

Moeller BBA -16 Series installation instructions

Moeller

Moeller BBA -16 Series installation instructions

Acer MWA3 quick start guide

Acer

Acer MWA3 quick start guide

Connect Tech ADG095 user guide

Connect Tech

Connect Tech ADG095 user guide

cable matters 604002 user manual

cable matters

cable matters 604002 user manual

Solwise PL-85PEW Easy start

Solwise

Solwise PL-85PEW Easy start

HP Photosmart 7100 user guide

HP

HP Photosmart 7100 user guide

HP E2494A installation guide

HP

HP E2494A installation guide

StarTech.com USB150WN1X1 quick start guide

StarTech.com

StarTech.com USB150WN1X1 quick start guide

Lindy 43198 user manual

Lindy

Lindy 43198 user manual

A&D AD-8527 instruction manual

A&D

A&D AD-8527 instruction manual

Motorola WU830G user guide

Motorola

Motorola WU830G user guide

Hawking HUF2 Specifications

Hawking

Hawking HUF2 Specifications

Allen-Bradley E3 Plus installation instructions

Allen-Bradley

Allen-Bradley E3 Plus installation instructions

Trust BT-2210Tp manual

Trust

Trust BT-2210Tp manual

HP NC7170 overview

HP

HP NC7170 overview

Uconnect BLE-485C user manual

Uconnect

Uconnect BLE-485C user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Therma-Cord
Power cord with Integrated Thermostat,
By Radiant Solutions Company
INTRODUCTION
SPECIFICATIONS
The Therma-Cord (TC-2000) is a thermostatically controlled power cord set that
automatically powers on at 37ºF and powers off at 50ºF.
120 Volts, 15 amps (USA), 12 amps (Canada), 50-60Hz, NEMA plug and receptacle
with LED indicator lights, 16” 14 gauge power cord with PVC jacket, thermostat closes
(‘turns on’) at 37ºF and opens (‘turns off’) at 50ºF, within a 4ºF range.
LIMITED WARRANTY
Seller warrants this product, if used in accordance with all applicable instructions,
to be free from original defects in material and workmanship for 3 years. You must
register your warranty with the company at www.radiantsolutionscompany.com
within 60 days of purchase to qualify for warranty coverage. If the product should
prove defective in material or workmanship within the warranty period, Seller will
repair or replace the product, at its sole discretion. Service under this Warranty can
only be obtained by your delivering or shipping the product (with all shipping or
delivery charges prepaid) to: Radiant Solutions Company, 1515 5th Street South,
Hopkins, MN 55343. Seller’s maximum liability shall not in any case exceed the list
price for the product claimed to be defective. The Seller will not be responsible for
consequential damages arising with respect to the product for any reason. Warranty
does not apply to any failure of LED indicator lights on the device, if present (i.e.,
at plug or receptacle) as these are convenience features that are not relevant to the
essential performance of the device.
ADDITIONAL SPECIFICATIONS
The TC-2000 is suitable for use in temperatures between -40ºF and 122ºF and should
be stored in temperatures between -40ºF and 140ºF. Type 2B Action and Automatic
Reset, Pollution degree: 4, Impulse voltage 1500v, UL Type 3R, Thermal Cutout.
www.radiantsolutionscompany.com
Phone: 1-877-387-4218
1515 5th Street South, Hopkins
Minnesota, 55343
Scan this QR code to get the
most current manuals
USER MANUAL: Model: TC-2000
Thermostat
GFCI Protected Outlet
Receptacle
Plug from device
15” Min
Warning:
DO NOT expose receptacle to excessive
moisture and/or standing water
Plug the Therma-Cord directly into a GFCI protected outlet and then plug in the device
you wish to have thermostatically controlled into the receptacle on the Therma-Cord.
SAFETY WARNINGS AND GUIDELINES
Please read this entire document before using the Therma-Cord, paying extra
attention to these safety warnings and guidelines. Please keep this manual in a safe
place for future reference.
•
•
•
•
•
•
•
•
DO NOT connect Therma-Cord to an ungrounded outlet or use a “cheater” plug to
bypass the ground connection.
Only plug the Therma-Cord into branch circuit with 30-mA ground fault protection,
especially for xed outdoor electric de-icing and snow-melting equipment.
DO NOT plug in equipment that draws more total amps than the amperage rating
for the Therma-Cord.
The individual user should take care to determine prior to use whether the
Therma-Cord is suitable, adequate or safe for the use intended. Since individual
applications are subject to great variation, the manufacturer makes no representa-
tion or warranty as to the suitability or tness of the Therma-Cord for any specic
application.
DO NOT install the Therma-Cord where excessive moisture is present or allow any
part of the device to be exposed to standing water.
The Therma-Cord has no serviceable parts. Do not attempt to open, service or
modify.
DO NOT plug the male end of Therma-Cord into an extension cord. Always plug it
into a GFCI protected outlet.
Prior to use, check the Therma-Cord for any signs of physical damage. Do not use
if it is damaged. If the cord is damaged the entire device should be discarded.
INSTRUCTIONS