Rankin-Delux 23 series User manual

1
3245 Corridor Drive Phone : 951-685-0081
Eastvale, CA 91752 Fax : 951-685-0084
Website : www.rankindelux.com email : rankinone@aol.com
OWNER'S MANUAL
LAVA ROCK TYPE CHAR-BROILER / 23 SERIES
INSTALLATION, OPERATING, MAINTENANCE INSTRUCTIONS, PARTS LIST
NOTE
UPON RECEIPT, CAREFULLY CHECK YOUR APPLIANCE FOR FREIGHT DAMAGE. MAKE A NOTATION
OF ANY VISIBLE DAMAGE TO THE CARTON OR CRATE ON THE CARRIER'S WAY BILL. IF YOU
DISCOVER ANY DAMAGE AFTER YOU UNPACK YOUR APPLIANCE, IMMEDIATELY CALL THE
CARRIER AND REQUEST AN INSPECTION. KEEP ALL CRATES AND CARTONS UNTIL THE DAMAGE
HAS BEEN INSPECTED.
CHECK APPLIANCE RATING PLATE ON STAINLESS STEEL FRONT PANEL FOR TYPE OF GAS. IF THE
PLATE DOES NOT CORRESPOND TO YOUR GAS TYPE, CONTACT YOUR DEALER UPON RECEIPT.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN
THE VICINITY OF THIS OR ANY OTHER APPLIANCE
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause
property damage, injury or death. Read the installation, operating and maintenance instructions
thoroughly before installing or servicing this equipment.
KEEP THIS MANUAL FOR FUTURE USE
After installation of your appliance, immediately contact your local gas supplier to obtain information as to
what action to take in the event that the user smells gas.
This information must be posted in a prominent location.
IMPORTANT
FAILURE TO FOLLOW THESE INSTRUCTIONS WILL VOID WARRANTY
Safe and satisfactory operation of your appliance depends to a great extent upon its installation. Installation must
conform with local codes or, in the absence of local codes, with National Fuel Gas Code ANSI Z 223.1 (Latest
Edition).

2
INSTALLATION MUST BE MADE BY A LICENSED/QUALIFIED COMMERCIAL GAS EQUIPMENT
SERVICE AGENCY/COMPANY
The input rating on your appliance is for elevations up to 2,000 feet. For elevations above 2,000 feet the rating must
be reduced to 4% for each 1,000 feet above sea level.
INSTALLATION, OPERATION & MAINTENANCE
(1) PRE-INSTALLATION - SPACE AND GAS CONNECTIONS
(a) The area around the appliance must be kept free and clear from combustibles. The area in front of
and above the appliance must be clear to avoid any obstruction to the flow of combustion and ventilation air. Means
must be provided for adequate air supply and adequate clearance from air openings into the combustion chamber.
(b) Adequate clearance must be provided in front and sides of appliance for servicing and proper
operation.
(c) A mechanical exhaust hood must be installed above the broiler. Refer to NFPA 00 and all local
codes.
(d) The lava rock supplied with your broiler must be spread evenly and loosely on the cast iron grates
located above the burners (one layer only). BROILER MUST BE COOL BEFORE SPREADING LAVA ROCKS.
(2) INSTALLATION
(a) The gas pressure regulator supplied with the appliance must be installed on the appliance prior to
connection to the gas supply lines. The outlet pressure setting is 5" water column on natural gas and 10" water column
on propane gas (LP Gas).
(b) Connect the appliance to a gas supply line having a 3/4" iron pipe size or larger. If a flexible
connector is used it must be a commercial type GA Approved 3/4" I.D or larger. (1/2" for Model 1223 and 2123)
(Domestic range connector will not permit proper operation). A gas shutoff valve must be installed in the gas supply
line ahead of the appliance for future service. Use pipe sealant on all joints. Sealant must be resistant to the action of
LP gas. A 1/8" pressure tap is provided on the gas manifold for checking the gas pressure. Always check pressure
with all burners on and adjacent equipment operating.
(c) Level the appliance by adjusting feet at the bottom of the legs. Leveling is important for proper
operation and combustion. If a level is not available, use pan of water.
(d) Your appliance is designed for installation in a non-combustible location only
(e) To check for leaks, use a soap and water solution. DO NOT USE OPEN FLAME.
(f) The appliance and its individual shutoff valve must be disconnected from the gas supply piping
system during any pressure testing of the system at test pressures in excess of 1/2 psig (3.45kPa).
(g) The appliance must be isolated from the gas supply piping system by closing its individual manual
shutoff valve during any pressure testing of the system at test pressures equal to or less than 1/2 psig (3.45kPa).
(3) OPERATION
(A) LIGHTING THE BROILER
(1) Turn off all burners and pilot valves. Wait 5 minutes.
(2) Remove front panel. Turn on lighter valves and light all pilots then replace front panel.
(3) Adjust pilot flame by turning the pilot valve screw clockwise or counterclockwise.
(4) Turn on burner valves to operate broiler.
(5) For complete shutdown, turn off burner valves and gas shut off valve located ahead of the
appliance inlet.

3
(4) MAINTENANCE
(a) CLEANING Appliance must be cool before cleaning.
Broiler grates should be cleaned periodically by wire brushing or washing in hot water and
detergent. After washing, always flush with hot water and heat to high for 10 minutes until dry.
(b) The stainless steel front and trim should be cleaned with mild soap or detergent or with a liquid
cleanser especially for use on stainless steel. Never attempt to clean stainless steel with steel wool, abrasive cloths
or powders. The drip tray should be emptied as needed and cleaned with hot water and soap or detergent.
(c) Empty grease pan as required to prevent overflowing. Clean with hot water, soap, or detergent.
(5) SERVICE
No immediate need for service is anticipated. Thereafter service needs vary with frequency of use. Twelve
hours per day, seven days per week is considered heavy use and broiler should be serviced every ninety days. For
lesser use, consider service every six months. If valves become hard to turn, they should be repacked or replaced.
ALL SERVICE SHOULD BE DONE BY QUALIFIED PERSONNEL FROM A COMMERCIAL GAS
EQUIPMENT SERVICE AGENCY OR THE GAS SERVICE DEPARTMENT OF YOUR LOCAL GAS
UTILITY COMPANY. DISCONNECT POWER SUPPLY BEFORE SERVICING.
ANY SERVICE UNDER WARRANTY MUST BE AUTHORIZED BY FACTORY
For appliances equipped with casters, the installation shall be made with a connector that complies with the standard
for connectors for movable gas appliances, ANSI Z21.69 (Latest Edition), and a quick disconnect device that
complies with the standard for Quick Disconnect devices for use with gas fuel, ANSI 21.41 (Latest Edition).
Adequate means must be provided to limit the movement of the appliance without depending on the connector and the
quick disconnect device or its associated piping to limit the appliance movement.
Note: If the appliance is removed from it's original installed position, the caster locks must be switched back on.
Table of contents
Popular Grill manuals by other brands

Royal Catering
Royal Catering RCPES-380 user manual

DS Produkte
DS Produkte SW-100MG instruction manual

Char-Broil
Char-Broil Quickset Assembly, use & care manual

Broil King
Broil King D3-1 owner's manual

Sharper Image
Sharper Image STAINLESS STEEL SUPER GRILL instruction manual

Cuisinart
Cuisinart CPO-640 Assembly and operation instructions