Raytec VARIO 2 PoE User manual

1www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
POE
Quick InstallInstallation Guide
Safety Information:
White Light and IR Variants (850nm & 940nm)
Caution –Risk Group 2. Avoid Exposure / use protection.
See Safety Information in FULL Instruction Guide for more details.
Box Contents:
VARIO2 POE Illuminator , 60° beam angle ILS, User Guide
(ILS: Interchangeable Lens System)
Optional Accessories: Remote Controller for additional programming;
80˚ beam and 120˚ beam angle ILS; Bracketry
Factory Default Set-Up:
35˚ Beam Angle ; Max 100% Power
Photocell sensitivity –MID; Telemetry Input Closed (Premium variants only)
Status LEDs –ON ; No PIN Set
Programming function will auto-disable after 7 Days (if no manual buttons used)
VARIO2 Specifications Table:
See Page 26 and 27 in Full Instruction Guide
PoE Detection:
There is a switch on the VAR2-PoE-w8-1, i8-1 and i8-1-C illuminators which
can be used to change the PoE detection resistance of the illuminator
(24.9KΩ is the factory default setting).
The majority of PSE equipment requires a detection resistance of 24.9KΩ to
establish a PoE link. Some models of PSE equipment require12.5KΩ.
For 24.9 KΩ, slide switch to the LEFT (factory default – as shown). For 12.5 KΩ,
slide switch to the RIGHT.

2www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Wiring:
1. Mount Illuminator
2. Connect Illuminator to suitably rated PoE source (check specification)
Or 24 V dc for Premium model only.
3. Complete configuration, wiring and final set-up using manual push buttons on
the illuminator or VARIO Remote Controller (VRC) - VRC is an optional
accessory.
For Cat5 wiring –use T568-B wiring standard.
Premium Versions only:
Red = +ve, black = -ve
White & Yellow wires = Photocell following contact, Volt free output, Non polarity
sensitive
Orange and Purple Wires = Telemetry input Volt free / dry contact or TTL input
Lens Selection:
Select different beam angle –if required
VARIO is factory set and delivered with a 35˚ beam width angle.
To alter to 10˚, simply remove interchangeable lens (ILS).
To alter to 60˚, replace with other ILS lens supplied.
Other angle ILS lenses are available to order: 80˚ and 120˚.
Remove base plate from VARIO2 unit using 2.5mm allen/hex key. Insert required ILS lens
and re-attach base plate securely ensuring gasket is correctly located.
Step 1
Unscrew
baseplate
Step 2
Remove
baseplate
Step 3
Remove /
Replace diffuser
lens
Step 4
Replace
baseplate
& tighten

3www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Manual Button Operation
Buttons are accessed by removing the base plate at the bottom of the unit (2
screws)
Action
Required
Step1 :
LHS Button
LHS
LED
Step 2 :
RHS Button
RHS
LED
Comment
Power Adjust
1 x Push
Solid
Red
Each Push
cycles
through
power
levels
Green flashes
indicate level.
High power (5
flashes) to Low
power (1 flash)
Photocell
Adjust
2 x Push
Solid
Green
Each Push
cycles
through
photocell
levels
Green flashes
indicate 3
setting levels.
Low to Med to
High sensitivity.
Then Solid Red
for Photocell
disabled
Status
Indicator
LEDS On / Off
3 x Push
Solid
Amber
Each Push
cycles
between
On and
Off
On –Green
Off - Red
Factory Re-
set (Does not
Re-set PIN)
1 x Long
Push
(4
Seconds)
Flashing
Red –
Push and
Hold until
both LEDs
flash
Amber
Solid Red –After
4s both LEDs
Flashing Amber
Reverts to
Programming
Mode unless a
PIN is present. If a
PIN is present
reverts to original
mode before re-
set
Disable
Remote and
Enter
Operating
Mode or
Enable
Remote and
Enter
Programming
Mode
1 x Long
Push (4s),
then 1 x
short Push
Flashing
Green
Push to
cycle
Disable /
Enable
Disable –Red
Enable - Green
Reverts to the
Mode requested
unless a PIN is
present. If a PIN is
present and you
are in Operating
Mode you
cannot change
to Programming
Mode

4www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Action
Required
Step1 :
LHS Button
LHS
LED
Step 2 :
RHS Button
RHS
LED
Comment
Disable /
Enable
Manual
Buttons
1 x Long
Push (4s),
then 2 x
short Push
Flashing
Amber
Push to
cycle
Disable /
Enable
Disable –Red
Enable - Green
Buttons will be
Disabled 30
minutes after this
selection is made
–This is to allow
the user to re-
enable manual
buttons if
required
Full Re-set
(including
PIN re-set)
Keep both
buttons
depressed
during
power up –
LEDs will
both flash
Amber
After
power
up –
Flashing
Amber
straight
away
Keep both
buttons
depressed
during
power up
–LEDs will
both flash
Amber
After power up
–Flashing
Amber straight
away
Illuminator will
revert to
Programming
Mode, Full
factory default
including No PIN
The illuminator has two modes; (1) Programming Mode when the remote control
can be used and (2) Operating Mode when most of the remote control functions
are disabled (see Remote Control Instructions for more details)
Manual Buttons are always available in programming mode or if they have been
disabled, they can be enabled in programming mode.
Manual Buttons are available in operating mode, provided they have not already
been disabled.
The number of button pushes indicated above are based on the user starting with
the illuminator in either programming or operating mode.
If the user has already started to program the units, then the number of button
pushes on the left hand will take them to the next function as per the sequence in
the table.
If no buttons are pressed within 2 minutes then the illuminator will automatically
default back into the previous mode it was in –programming or operating mode.

5www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990

6www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Remote Control Operation for PIN set and Manual
Button Disable / Enable
Action
Required
Available
Mode
Step1
Step 2
LHS
LED
RHS
LED
Comment
Disable
Remote
Prog Mode
Press
<Disable
Remote
Control> for
4 seconds
N/A
Solid Green
Flashing
Amber to Solid
Amber to Off
Illuminator will go
to Operating
Mode. RHS LED -
Flashing Amber
to Solid Amber
when button
pressed. RHS LED
turns Off when in
Operating Mode.
Disable
Manual
Buttons
Operating
Mode
Press
<Disable
Remote
Control> for
4 seconds
N/A
Solid Green –
After 4 seconds
Flashing Red
(Returns to Solid
Green after
button release)
Off to Solid
Amber, then
after 4
seconds
Flashing Red
(Returns to
Solid Green
after button
release)
Must be done
within 5 minutes
of Disabling
remote / entering
Operating Mode.
Change will take
effect after 30
minutes
Create or
Change
PIN
Prog Mode
Press <Status
Button> for 4
seconds
Enter valid
PIN
character
x 4
Green to
Intermittent
Flashing Red /
Green
Solid Amber
to Flashing Red
Flash qty
counts down
the No. of
valid
characters
required
After PIN created
Illuminator goes
to Programming
Mode (Standard
LED indication)
Enter
existing PIN
Operating
Mode
Press <Status
Button> for 4
seconds
Enter valid
PIN
character
x 4
Green –
Intermittent
Flashing Red /
Green
Solid Amber to
Flashing Green
Flash qty
counts down
the No. of
characters
required
After PIN created
Illuminator goes
to Programming
Mode (Standard
LED indication)
If invalid PIN
entered both
LEDs flash red and
unit will stay in
Operating Mode
Delete PIN
Prog Mode
Press <Status
Button> for 4
seconds
Press <Re-
Set> button
4 times
Green –
Intermittent
Flashing Red /
Green
Solid Amber to
Flashing Red
Flash qty
counts down
the No. of
characters
required
After PIN deleted
Illuminator goes
to Programming
Mode (Standard
LED indication)
For full PIN function detail (inc valid PIN characters) –see FULL instruction
guide

7www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
LED Status Indicators:
Programming Mode and Operating Mode
On first power up (Factory Default) the illuminator automatically enters
Programming Mode. It will then time out automatically after 7 Days to Operating
Mode unless the user actively changes the lamp settings or uses the manual
buttons. The LED Indicators feedback the mode you are in. (They are also used for
PIN or Manual Button Control Modes –please see tables / FULL Instruction Manual)
During Programming Mode and Operating Mode the two LED’s indicate the
following status :
LHS SOLID GREEN: Power Applied
LHS FLASHING GREEN: Remote control IR received problem
RHS FLASHING AMBER: Indicates unit is in programming mode
(Programming Mode Only)
RHS SOLID AMBER: Indicates that a valid command is being received
(Programming Mode Only)
LHS FLASHING RED: Voltage supply problem detected
LHS SOLID RED: Illuminator LED fault detected
All functions of the remote control and buttons are available in Programming
Mode.
The only function of the Remote Control available during Operating Mode is LED
Status Indicators Enable/Disable, entering a PIN or disabling manual buttons (if
done at the same time as disabling the remote –see FULL Instruction Manual
RESET:
Settings Re-set : Pressing and holding the RESET BUTTON on the remote control
or using the manual buttons to complete a RESET will restore the factory settings
to the illuminator. Note : It will not remove a PIN if one is present.
Full Re-set : Re-cycling the power whilst pressing both manual buttons will
restore factory settings and remove a PIN if one is present.
Both indicator LEDs flash amber for both above re-sets when complete.

8www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
VARIO2 Quick Troubleshoot:
Ensure all tests are undertaken by a qualified, trained engineer. Ensure safe
working practices are followed at all times.
•Check rating of PoE power source is suitably rated or 24V dc (Premium only)
•Check PoE resistance detection switch is correctly rated
•Check LED status indicators for relevant information
•Check camera and illuminator alignment and angles
See FULL Instruction Guide for more details of toubleshooting
For in-depth Troubleshoot, see Full Instructions, or contact Raytec.
VA2 POE/16/1.0 Quick Guide
Table of contents